FieldLab IECEx Certificate of Conformity

IECEx Certificate
of Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSION
IEC Certification Scheme for Explosive Atmospheres
for rules and details of the IECEx Scheme visit www.iecex.com
Certificate No.:
IECEx ETL 14.0039
Issue No: 0
Status:
Current
Page 1 of 3
Date of Issue:
2015-09-01
Applicant:
Ralston Instruments LLC
15035 Cross Creek Parkway
Newbury, OH 44065
United States of America
Electrical Apparatus:
FLP1 Pressure FieldLab
Optional accessory:
Type of Protection:
Intrinsic Safety 'ia'
Marking:
Ex ia IIC T4 Ga
-10°C ≤ Ta ≤ +50°C
IECEx ETL 14.0039
Approved for issue on behalf of the IECEx
Certification Body:
Don Card
Position:
Certification Officer
Signature:
(for printed version)
Date:
2015-09-01
1. This certificate and schedule may only be reproduced in full.
2. This certificate is not transferable and remains the property of the issuing body.
3. The Status and authenticity of this certificate may be verified by visiting the Official IECEx Website.
Certificate issued by:
Intertek
3933 US Route 11 South
Cortland NY 13045-2995
United States of America
Certificate history:
Issue No. 0 (2015-09-01)
IECEx Certificate
of Conformity
Certificate No:
IECEx ETL 14.0039
Issue No: 0
Date of Issue:
2015-09-01
Page 2 of 3
Manufacturer:
Ralston Instruments LLC
15035 Cross Creek Parkway
Newbury, OH 44065
United States of America
Additional Manufacturing
location(s):
This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the
IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and
found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx
Scheme Rules, IECEx 02 and Operational Documents as amended.
STANDARDS:
The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was
found to comply with the following standards:
IEC 60079-0 : 2011
Edition:6.0
Explosive atmospheres - Part 0: General requirements
IEC 60079-11 : 2011
Edition:6.0
Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"
IEC 60079-26 : 2006
Edition:2
Explosive atmospheres - Part 26: Equipment with equipment protection level (EPL) Ga
This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the
Standards listed above.
TEST & ASSESSMENT REPORTS:
A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in
Test Report:
US/ETL/ExTR15.0006/00
Quality Assessment Report:
US/ETL/QAR15.0013/00
IECEx Certificate
of Conformity
Certificate No:
IECEx ETL 14.0039
Issue No: 0
Date of Issue:
2015-09-01
Page 3 of 3
Schedule
EQUIPMENT:
Equipment and systems covered by this certificate are as follows:
The FLP1 Pressure FieldLab is a digital pressure gauge and is powered by an internal battery pack and contains a total of seven
printed circuit boards including a Main Controller Board, Battery Protector Board, External Power Board, optional RF Board, Keypad
Interface Board, USB Board, LCD Controller Board and Pressure Sensor.Power to the Main Controller Board is supplied from the
battery pack which contains the Battery Protector Board. There is also an External Power Board that connects to the Main Controller
Board to charge the battery pack. The battery pack may be re-charged by either an AC/DC supply that outputs 15 V or a DC supply
from a car charger that outputs up to 14.4 V. The chargers are not covered by this certificate. The instructions state that the product is
not to be charged in a hazardous location.
When the unit is powered from an external source, a Um of 21 V applies to the Power input terminals. There is also a USB input which
is not to be used in a hazardous location. When the USB connection is employed a Um of 5.25 V applies to the USB input terminals.
3.7 V Lithium Ion Battery; Um = 21 V (Power); Um = 5.25 V (USB)
See Annex for manufacturer's documents.
CONDITIONS OF CERTIFICATION: NO
Annex:
Annex IECEx ETL 14_0039.pdf
IECEx Certificate of Conformity
Certificate No:
Annex No. 1
IEC Ex ETL 14.0039
Issue No. 0
Manufacturer’s documents
Drawings associated with Issue 0 of this certificate:
Title
Drawing No.:
Rev.
Level:
FLP1 REAR NAMEPLATE
DGAU-0315
5
8/20/2015
FLP1 HAZARDOUS LOCATION INSTRUCTIONS
DGAU-0323
0
8/3/2015
TRANSDUCER ASSEMBLY
DGAU-0342
0
6/26/2015
TRANSDUCER ASSEMBLY
DGAU-0343
0
6/26/2015
BATTERY ASSEMBLY
DGAU-0345
0
7/17/2015
LCD ASSEMBLY
DGAU-0346
0
7/17/2015
WIFI PCB
DGAU-0347
0
7/17/2015
BOARD, MAIN
DGAU-0348
0
7/17/2015
BOARD, POWER
DGAU-0349
0
7/17/2015
BOARD, USB
DGAU-0350
0
7/17/2015
BOARD, LCD CONTROLLER
DGAU-0351
0
7/17/2015
KEYPAD TAIL
DGAU-0352
0
6/29/2015
CIRCUIT BOARD, BATTERY
DGAU-0353
0
7/17/2015
FLP1 DIGITAL PRESSURE DEVICE FULL
ASSEMBLY
DGAU-0354
0
7/17/2015
FRONT HOUSING/EMI ASSEMBLY
DGAU-0355
0
7/16/2015
KEYPAD
DGAU-0356
0
7/16/2015
REAR HOUSING/EMI ASSEMBLY
DGAU-0357
0
7/16/2015
CAP, STANDARD ASSEMBLY
DGAU-0358
0
7/16/2015
WIFI CAP, ASSEMBLY
DGAU-0359
0
7/16/2015
FIELDLAB MAIN SEALING O-RING
DGAU-0360
0
7/23/2015
BOARDS, ASSEMBLY
DGAU-0361
0
7/16/2015
FIELDLAB RF MODULE AND BLANK CAP SEAL
DGAU-0362
0
7/17/2015
Date:
Certificate issued by:
Intertek
3933 US Route 11 South
Cortland NY 13045-2995
United States of America
Page 1 of 1