Pulsar R96 Ex ia d nA

IECEx Certificate
of Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSION
IEC Certification Scheme for Explosive Atmospheres
for rules and details of the IECEx Scheme visit www.iecex.com
Certificate No.:
IECEx FMG 15.0034X
Issue No: 0
Status:
Current
Page 1 of 5
Date of Issue:
2016-01-22
Applicant:
Magnetrol International Inc.
705 Enterprise Street
Aurora, Il 60504
United States of America
Electrical Apparatus:
Pulsar R96 Radar Level Transmitter / Level Probe
Optional accessory:
Type of Protection:
Type "i", Type "n", Type "d" and Type "t"
Marking:
Ex db ia IIB+H2 T4...T1 Ta=-40°C to 70°C Ga/Gb
Ex ia IIC T4...T1 Ta=-40°C to 70°C Ga
Ex ic IIC T4...T1 Ta=-15 °C to 70°C Gc
Ex nA IIC T4...T1 Ta=-15°C to 70°C Gc
Ex ia tb IIIC T100°C Ta=-15°C to 70°C Db
Approved for issue on behalf of the IECEx
Certification Body:
James E Marquedant
Position:
Manager, Electrical Systems
Signature:
(for printed version)
Date:
1. This certificate and schedule may only be reproduced in full.
2. This certificate is not transferable and remains the property of the issuing body.
3. The Status and authenticity of this certificate may be verified by visiting the Official IECEx Website.
Certificate issued by:
Certificate history:
Issue No. 0 (2016-01-22)
IECEx Certificate
of Conformity
Certificate No:
IECEx FMG 15.0034X
Issue No: 0
Date of Issue:
2016-01-22
Page 2 of 5
FM Approvals LLC
1151 Boston-Providence Turnpike
Norwood, MA 02062
United States of America
IECEx Certificate
of Conformity
Certificate No:
IECEx FMG 15.0034X
Issue No: 0
Date of Issue:
2016-01-22
Page 3 of 5
Manufacturer:
Magnetrol International Inc.
705 Enterprise Street
Aurora, IL 60504
United States of America
Additional Manufacturing
location(s):
Orion Instruments
2105 Oak Villa Boulevard
Baton Rouge, LA 70815
United States of America
This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the
IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and
found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx
Scheme Rules, IECEx 02 and Operational Documents as amended.
STANDARDS:
The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was
found to comply with the following standards:
IEC 60079-0 : 2011
Edition:6.0
Explosive atmospheres - Part 0: General requirements
IEC 60079-1 : 2014-06
Edition:7.0
Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d"
IEC 60079-11 : 2011
Edition:6.0
Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"
IEC 60079-15 : 2010
Edition:4
Explosive atmospheres - Part 15: Equipment protection by type of protection "n"
IEC 60079-26 : 2014-10
Edition:3.0
Explosive atmospheres – Part 26: Equipment with Equipment Protection Level (EPL) Ga
IEC 60079-31 : 2013
Edition:2
Explosive atmospheres - Part 31: Equipment dust ignition protection by enclosure "t"
This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the
Standards listed above.
TEST & ASSESSMENT REPORTS:
A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in
Test Report:
US/FMG/ExTR15.0039/00
Quality Assessment Report:
CA/CSA/QAR06.0004/09
IECEx Certificate
of Conformity
Certificate No:
IECEx FMG 15.0034X
Issue No: 0
Date of Issue:
2016-01-22
Page 4 of 5
Schedule
EQUIPMENT:
Equipment and systems covered by this certificate are as follows:
R96-5abc-def-RAg-hij-k00. Pulsar R96 Radar Level Transmitter.
a = Signal Out: 1 or 2.
b = Options: 0 or 1.
c = Accessories: 0 or A.
d = Classification: 1, 3 ( when a = 1 or 2), 0, A, B or C.
e = Housing/Conduit Connection: 1 or 2.
f = Options: 0, 2 or 3.
g = Configuration Style: A, B, C, 3, 4, or 6.
h = Material of Construction. Antenna/ Mounting Nut: A, B, C, G, L or K.
i = Process Connection Size Type: 31, 32, 43, 44, 45, 53, 54, 55, 63, 64, 65, 73, 74, 75, 83, 84, 85, DA, DB, DD, EA, EB, ED, FA, FB,
FD, GA, GB, GD, HA, HB, HD, 3P, 4P, 5P, 6P or 7P.
j = O rings: 0, 1, 2 or 8.
k = Maximum Nozzle Length: 0, 1, 2 or 3.
CONDITIONS OF CERTIFICATION: YES as shown below:
1. The enclosure contains aluminum and is considered to present a potential risk of ignition by impact or friction. Care must be taken
during installation and use to prevent impact or friction.
2. To maintain the T4 ...T1 temperature code care shall be taken to ensure the enclosure temperature does not exceed 70ºC.
3. The risk of electrostatic discharge shall be minimized at installation, following the direction given in the instruction.
4. Contact the original manufacturer for information in the dimensions of flameproof joints.
5. For Installation with ambient temperature of 70ºC, refer to the manufacturer’s instructions for guidance on proper selection of
conductors.
6. Provisions shall be made to provide transient overvoltage protection to a level not to exceed 119Vdc.
7. The sensor probes are rated with an Equipment Protection Level of Ga and Da.
8. Temperature codes for the ratings Ex db ia IIB+H2 , Ex ia IIC, Ex nA IIC and Ex ic IIC are defined by the following table:
Process temperature(PT) Temperature Code-TCG (GAS)
IECEx Certificate
of Conformity
Certificate No:
IECEx FMG 15.0034X
Issue No: 0
Date of Issue:
2016-01-22
Page 5 of 5
From 0°C to 110°C
T4
From 110°C to 175°C
T3
From 175°C to 275°C
T2
From 275°C to 425°C
T1