N 242

Memory controllers
Manual and automated format alignment
Display LCD two lines, interface RS485
N 242
Features
–– Memory controller for manual and automatic format
alignment
–– Display: LCD backlit, two lines alphanumeric,
multilingual
–– Programming and memory unit
–– Memory for 100 formats with max. 32 position
displays
–– Interface RS485
Technical data - mechanical design
Voltage supply
85...265 VAC (50/60 Hz)
Operating temperature
-10...+50 °C
Power consumption
42 VA
Storage temperature
-20...+70 °C
Reverse polarity protection No
Relative humidity
80 % non-condensing
Sensor supply
24 VDC ±10 % / <0.9 A
Protection DIN EN 60529
IP 65 (face with seal)
Display
LCD-TFT, 2-lines, backlit,
alphanumeric
Connection
Screw terminal connector
Function
User menu, multilingual
Motive positioning
Memory unit for 100 format
profiles
Programming of max. 32 SPA
SPA zero point alignment
Start position for target display
N 155
Core cross-section
1.5 mm²
Operation / keypad
10 figure keypad with 8 function
keys
Housing type
Built-in housing
Dimensions
144 x 144 x 116.5 mm
Cutout dimensions
125 x 125 mm
Mounting depth
120 mm
Front panel installation by clip
frame
Keylock
Secured by code
Mounting
Control inputs
Shaft release
Start positioning
Weight approx.
600 g
Material
Polycarbonate black, UL 94V-0
control outputs relay
Shafts in position
Start positioning
Switching capacity relay
100 VA / 30 W
Switching current relay
1 A
Switching voltage relay
265 VAC
Interface
RS485 (ASCII protocol)
Data memory
>10 years in EEPROM
Programmable
parameters
Language selection
Standard
DIN EN 61010‑1
Protection class II
Overvoltage category II
Pollution degree 2
Emitted interference
DIN EN 61000-6-4
Interference immunity
DIN EN 61000-6-2
Approval
UL approval / E63076
1
www.baumer.com/motion
14/5/2014
Technical data - electrical ratings
Subject to modification in technic and design. Errors and omissions excepted.
N 242 - Automated/manual format alignment
Memory controllers
Manual and automated format alignment
Display LCD two lines, interface RS485
N 242
Part number
N 242.
1
Description
1
2
N 242 memory controller intended for front panel installation serves as memory and operating unit. By RS485
network up to 100 format profiles with several position
values for maximum 32 spindles can be saved and recalled
for retransmission to the SPAs (spindle position displays)
respectively actuators (multiconDrive) upon pressing a button. The two-line SPA display indicates both actual value
and target. Similar to the SPA display, the controller is giving
information whether the spindles are "in position" or "not in
position".
The keypad provides 10 figures and 8 function keys allowing easy parameter input and recall. multiconDrive provides
an external start key for centralized release of positioning
cycles. Programmable parameters enable perfect adaptation to the application.
Programmable parameters and functions:
– tolerance window, end position switch-off
– collective groups of 5 spindles each
– teach-in of target values
– spindle pitch and compensation
– measuring unit mm/inch
– multilingual
AX01
Voltage supply
2 85...265 VAC
Outputs
1 With output
Interface
1 RS485
Kx1
Stop
Kx2
Start
Lx
Kx
Connection diagram
4
3
2
1
Supply voltage
85-265 VAC
50/60 Hz
5
release
positioning
0V
Release
shaft
Start
position
6
Shaft in
position
20 19 18 17
+24V
Tx,Rx-
Tx,Rx+
22 21
Dimensions
124
124
16.5
120
2
www.baumer.com/motion
14/5/2014
2-4
144
144
Subject to modification in technic and design. Errors and omissions excepted.
116.5
20