EN

Spindle position displays
Through hollow shaft max. ø14 mm, manual format alignment
Display LCD two lines, interface RS485
N 150
Features
–– Manual format alignment
–– Through hollow shaft up to ø14 mm
–– Resolution: 1440 steps/revolution ±4096 revolutions
–– Display: LCD backlit, two lines
–– Absolute multiturn measuring system
–– Actual value and target display
–– Interface RS485
Technical data - mechanical design
Voltage supply
24 VDC ±10 %
Shaft type
ø14 mm (through hollow shaft)
Current consumption
≤30 mA
Operating speed
≤600 rpm (short-term)
Display
LCD, 7-segment display,
2-lines, backlit
Protection DIN EN 60529
IP 50
Measuring principle
Absolute multiturn measuring
system
Operating temperature
-10...+50 °C
Storage temperature
-20...+70 °C
Measuring range
-99.99...+999.99 mm
-9.999...+99.999 inch
Relative humidity
80 % non-condensing
Torque support
Torque pin provided at housing
Steps per turn
1440
Connection
Number of turns
4096 / 12 bit
Spindle pitch
≤14 mm
Interface
RS485 (ASCII protocol)
- Male/female connector M8,
4-pin
- Cable output (30/15 cm) with
male/female connector M8,
4-pin
Data memory
Parameter buffer: EEPROM
Current value buffer: >10 years
by integrated 3 V lithium battery
Housing type
Surface-mount with hollow shaft
Dimensions
37 x 75 x 45 mm
Programmable
parameters
Display position horizontal/
vertical
Measuring unit mm/inch
Spindle pitch
Counting direction
Spindle tolerance
Positioning direction
Direction arrows
Tolerance window
Round up/down
Mounting
Surface-mount with hollow shaft
Weight approx.
120 g
Material
Polyamide black, UL 94V-0
Standard
DIN EN 61010‑1
Protection class II
Overvoltage category II
Pollution degree 2
Emitted interference
DIN EN 61000-6-3
Interference immunity
DIN EN 61000-6-2
Approval
UL approval / E63076
1
www.baumer.com/motion
21/3/2016
Technical data - electrical ratings
Subject to modification in technic and design. Errors and omissions excepted.
N 150 with connector output
Spindle position displays
Through hollow shaft max. ø14 mm, manual format alignment
Display LCD two lines, interface RS485
N 150
Part number
N 150.
1
Description
3
A
N 150 spindle position display supports the editing engineer
in manual spindle positioning. The principal benefits of the
new electronic spindle position display are saving time in
machine setup and editing as well as eliminating errors
when aligning formats to new position values. The absolute
measuring system captures any change in position even
in powerless state. The backlit LCD display provides the
editing engineer with all necessary information for efficient
editing of new spindle positions. The two-line display shows
both current value and target. A little arrow signalizes the
editing engineer the direction the spindle must be turned to
get to the new position.
RS485 serial interface enables network of maximum 32
spindle position displays to PC or PLC.
For complete solutions also memory controllers serving as
decentralized operating and memory terminals are available. Up to 100 format profiles can be stored by teach-in.
Upon request the desired profile is recalled upon pressing a button and and retransmitted to every spindle position
display and shown as target.
01
Through hollow shaft
A ø14 mm
Display
A Inclined
B Horizontal at front
Voltage supply
3 24 VDC
Connection
0 Connector output M8
1 Cable output M8
Interface
1 RS485
Accessories
Adaptor cable between cable connector M8
and female M16, 1 m
Z 178.AW1
Cable connector M8, 4-pin, without cable with
integrated terminating resistor 120 Ω
Z 178.B01
Female connector M8, 4-pin, without cable
Z 178.D05
Data and supply cable M8, Master to N 150
and N 155, 5 m
Z 178.S01
Cable connector M8, 4-pin, without cable
Z 178.V01
Coupling cable with M8 - M8, 1 m cable
Z 178.V03
Coupling cable with M8 - M8, 3 m cable
Z 178.V05
Coupling cable with M8 - M8, 5 m cable
Z 178.V10
Coupling cable with M8 - M8, 10 m cable
Z 178.050
Data and supply cable, ø5 mm,
4 cores, shielded, on 50 m drum
2
www.baumer.com/motion
21/3/2016
Z 178.A01
Subject to modification in technic and design. Errors and omissions excepted.
Connectors and cables
Spindle position displays
Through hollow shaft max. ø14 mm, manual format alignment
Display LCD two lines, interface RS485
N 150
Terminal assignment
Connector
Assignment
Pin 1
Tx/Rx-, RS485
Pin 2
Tx/Rx+, RS485
Pin 3
Sensor supply +24 V
Pin 4
Sensor supply 0 V
M8 connector
1
3
M8 female
connector
2
2
4
4
1
3
Dimensions
75
Connect or output
4.8 Torque pin
6
°
10
150
300
28
Seal
14
45
A
1
M8
female
connector
13
52
12.5
M8
connector
Connector
Female connector
3
ø12
ø12
www.baumer.com/motion
Subject to modification in technic and design. Errors and omissions excepted.
6.5
31.8
30.15
A
60
16
Pin M4
13
26
37
2:1
ø6h9
ø14H7
ø20
22
20.5
75
0.5x 45°
Cable output
21/3/2016
Optional display
position