EN

Process displays
Analog measured value input, 2 limits
Large 14 mm display LED, 6-digits, programmable
PCD41
Features
–– Process display
–– Display 6-digits
–– Connection: One-channel analog sensor
–– Two limits as relay output
–– With peak value memory
–– Interface RS232 or RS422/RS485
Description
Voltage supply
24/48 VAC ±10 % (50/60 Hz)
115/230 VAC ±10 % (50/60 Hz)
12...30 VDC
Power consumption
6 VA, 4 W
Sensor supply
12...26 VDC / max. 80 mA
PCD41 is a display for measured values which signals are
available as voltage or DC current. The operator is aligning the display by means of the front keypad. Two optional
limits "P1" and "P2" that can be assigned at will allow production process control. Furthermore there is an electronic
peak value memory (slave pointer).
Display
LED, 7-segment display
Number of digits
6-digits
Technical data - mechanical design
Digit height
14 mm
Ambient temperature
0...+50 °C
Function
Digital display of 1 analog
measured value
Storage temperature
-20...+70 °C
Relative humidity
80 % non-condensing
Core cross-section
1.5 mm²
Protection DIN EN 60529
IP 65 (face with seal)
Analog input
Limits
Control inputs
Calculating functions
Offset (maximum and minimum
analogue limit)
Operation / keypad
Membrane with softkeys
Housing type
Built-in housing
Dimensions W x H x L
96 x 48 x 124 mm
Cutout dimensions
92 x 44 mm (-0.6)
Mounting depth
124 mm
Limits
Without, 2
Mounting
Clip frame for built-in housing
Input logic
PNP
Weight approx.
350 g (AC), 250 g (DC)
Control inputs
2 Inputs
Material
Housing: Makrolon 6485 (PC)
Control functions
Hold, Reset, Keylock, etc.
Data memory
>10 years in EEPROM
Outputs relay
Normally open or closed,
programmable
Interfaces
RS232, RS422, RS485
Standard
DIN EN 61010‑1
Protection class II
Overvoltage category II
Pollution degree 2
Emitted interference
DIN EN 61000-6-3
Interference immunity
DIN EN 61000-6-2
Analog input
Programmable
parameters
0(2)...10 V, 0(4)...20 mA
Resolution 12 bit
Temp. coeffic. typ. ±20 ppm/°C
1
www.baumer.com/motion
12/1/2015
Technical data - electrical ratings
Subject to modification in technic and design. Errors and omissions excepted.
PCD41 - Process display
Process displays
Analog measured value input, 2 limits
Large 14 mm display LED, 6-digits, programmable
PCD41
Part number
Block circuit diagram
PCD41.
PX01
9ROWDJH
VXSSO\
$QDORJLQSXW
Voltage supply
1 24 / 48 VAC
2 115 / 230 VAC
3 12...30 VDC
0
1
2
3
3HDNYDOXHPHPRU\
&RQWUROLQSXW
Inputs / outputs
0...10 V / no limits
0...20 mA / no limits
0...10 V / with limits
0...20 mA / with limits
75
Interface
0 Without interface
1 RS422 / RS485
2 RS232
0HDVXULQJYDOXH
0HDVXULQJ
YDOXH
56
75
6HQVRU
VXSSO\
/LPLW
/LPLW
56
7
7
5
5
2XWSXW
3
3
,QWHUIDFH
5656
7[' ,QWHUIDFH
56
5[' *1' Connection diagram
9 9
6HQVRU
VXSSO\
$QDORJ
LQSXW
3
3
/LPLWYDOXH
PD[9
WHUPLQDOWHUPLQDO
WHUPLQDO
75
75
56
&RQWURO
LQSXW
7['
5['
*1'
56
56
Comparator inputs
Input circuit
Control inputs
PNP-logic
Input level
Programmable
Input level Low
0...2 VDC
Input level High
3...40 VDC
Input resistance
3 kΩ
Relay outputs
Output circuit
Switching voltage max.
250 VAC / 110 VDC
Switching current max.
1A
Switching capacity max.
150 VA / 30 W
Relay responding time
5 ms
Dimensions
2
www.baumer.com/motion
12/1/2015
9ROWDJHVXSSO\
7
7
5
5
Subject to modification in technic and design. Errors and omissions excepted.
Trigger level