LL-20

Please contact the sales people for detailed datasheet!
LL SERIES
20W
SPECIFICATIONS
20~60W Isolated LED Driver for Commercial LED Lighting
FEATURES
> Active Power Factor Correction
> Can be Used for Lighting Equipment in
Protection Class I and II
> No Flickering
> 3 Year Warranty
> Constant Current Output
> Cooling by Free Air Convection
> Short Circuit, Over Voltage
Protections
Constant Current
SPECIFICATIONS
> 3 in 1 Dimming(0~10V, PWM, Resistor)
> Active Power Factor Correction
> Can be Used for Lighting Equipment in
Protection Class I and II
Constant Current
MODELS
Model
Output
TOL.
Power
EFF(typ.)
Model
Output
TOL.
Power
EFF(typ.)
Model
Output
TOL.
Power
EFF(typ.)
Model
Output
TOL.
Power
EFF(typ.)
LLMU20-C350
350mA (27-40V)
±5%
14W
83%
LLNU20-C300
300mA(35-55V)
±5%
16.5W
84%
LLMU20-C350A
350mA(27-40V)
±5%
14W
84%
LLNU20-C300A
300mA(35-55V)
±5%
16.5W
85%
LLMU20-C400
400mA (27-40V)
±5%
16W
85%
LLNU20-C350
350mA(35-55V)
±5%
19.25W
86%
LLMU20-C400A
400mA(27-40V)
±5%
16W
84%
LLNU20-C350A
350mA(35-55V)
±5%
19.25W
85%
LLMU20-C450
450mA (27-40V)
±5%
18W
86%
LLNU20-C400
400mA(35-55V)
±5%
22W
86%
LLMU20-C450A
450mA(27-40V)
±5%
18W
86%
LLNU20-C400A
400mA(35-55V)
±5%
22W
86%
LLMU20-C500
500mA (27-40V)
±5%
20W
86%
LLMU20-C500A
500mA(27-40V)
±5%
20W
86%
LLMU20-C550
550mA (27-40V)
±5%
22W
86%
LLMU20-C550A
550mA(27-40V)
±5%
22W
86%
CHARACTERISTICS
INPUT
OUTPUT
PROTECTION
ENVIRONMENT
SAFETY
LL SERIES
MODELS
LL SERIES
20W
20~60W Isolated LED Driver for Commercial LED Lighting
FEATURES
> 3 Year Warranty
> Constant Current Output
> Cooling by Free Air Convection
> Short Circuit, Over Voltage
Protections
CHARACTERISTICS
VOLTAGE RANGE, FREQUENCY
90~305VAC, 47~63Hz
VOLTAGE RANGE, FREQUENCY
90~305VAC, 47~63Hz
POWER FACTOR (Typ.)
0.95/230VAC (70%~100% full load)
INPUT CURRENT (Typ.)
0.4A/230VAC
POWER FACTOR (Typ.)
0.95/230VAC (70%~100% full load)
INPUT CURRENT (Typ.)
INRUSH CURRENT (Typ.)
0.4A/230VAC
COLD START, 60A/230VAC
INRUSH CURRENT (Typ.)
COLD START, 60A/230VAC
LINE REGULATION
±5%
LINE REGULATION
±5%
LOAD REGULATION
±5%
LOAD REGULATION
±5%
SETUP, RISE TIME
≤1S at full load (cold start, power on)
SETUP, RISE TIME
≤1S at full load (cold start, power on)
RIPPLE
<1V
RIPPLE
<4V
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE
110-130% Vout, recovers automatically after fault condition is removed
OVER VOLTAGE
110-130% Vout, recovers automatically after fault condition is removed
OPERATING
Temperature -30°C ~ +50°C, Humidity 20 ~ 90% RH non-condensing
OPERATING
Temperature -30°C ~ +50°C, Humidity 20 ~ 90% RH non-condensing
STORAGE
Temperature -40°C ~ +80°C, Humidity 10 ~ 90% RH
STORAGE
Temperature -40°C ~ +80°C, Humidity 10 ~ 90% RH
SAFETY STANDARDS
Design refer to EN61347-1, EN61347-2-13
SAFETY STANDARDS
Design refer to EN61347-1, EN61347-2-13
EMC
Compliance to EN55015, EN61000-3-2, 3, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547
EMC
Compliance to EN55015, EN61000-3-2, 3, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547
MTBF
400K hours min. refer to MIL-HDBK-217F (25°C)
MTBF
400K hours min. refer to MIL-HDBK-217F (25°C)
INPUT
OUTPUT
PROTECTION
ENVIRONMENT
* Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=230VAC
SAFETY
* Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=230VAC
MECHANICAL SPECIFICATION
18
LL SERIES
MECHANICAL SPECIFICATION
Dimensions in mm
Dimensions in mm
Weight: 140g
Weight: 145g
19