Please contact the sales people for detailed datasheet! LL SERIES 20~60W Isolated LED Driver for Commercial LED Lighting 60W SPECIFICATIONS FEATURES > Active Power Factor Correction > Can be Used for Lighting Equipment in Protection Class I and II > No Flickering > 3 Year Warranty > Constant Current Output > Cooling by Free Air Convection > Short Circuit, Over Voltage Protections Constant Current Output TOL. Power EFF(typ.) Model Output TOL. Power EFF(typ.) 1200mA (27-40V) ±5% 48W 86% LLMU60-C1200A 1200mA (27-40V) ±5% 48W 86% LLMU60-C1300 1300mA (27-40V) ±5% 52W 86% LLMU60-C1300A 1300mA (27-40V) ±5% 52W 86% LLMU60-C1400 1400mA (27-40V) ±5% 56W 86% LLMU60-C1400A 1400mA (27-40V) ±5% 56W 86% LLMU60-C1500 1500mA (27-40V) ±5% 60W 86% LLMU60-C1500A 1500mA (27-40V) ±5% 60W 86% LLMU60-C1550 1550mA (27-40V) ±5% 62W 86% LLMU60-C1550A 1550mA (27-40V) ±5% 62W 86% CHARACTERISTICS PROTECTION ENVIRONMENT SAFETY LL SERIES MODELS LLMU60-C1200 OUTPUT SPECIFICATIONS > 3 in 1 Dimming(0~10V, PWM, Resistor) > Active Power Factor Correction > Can be Used for Lighting Equipment in Protection Class I and II Model INPUT 60W Constant Current MODELS LL SERIES 20~60W Isolated LED Driver for Commercial LED Lighting FEATURES > 3 Year Warranty > Constant Current Output > Cooling by Free Air Convection > Short Circuit, Over Voltage Protections CHARACTERISTICS VOLTAGE RANGE, FREQUENCY 90~305VAC, 47~63Hz VOLTAGE RANGE, FREQUENCY 90~305VAC, 47~63Hz POWER FACTOR (Typ.) 0.92/230VAC (70%~100% full load) INPUT CURRENT (Typ.) 0.9A/230VAC POWER FACTOR (Typ.) 0.92/230VAC (70%~100% full load) INPUT CURRENT (Typ.) INRUSH CURRENT (Typ.) 0.9A/230VAC COLD START, 60A/230VAC INRUSH CURRENT (Typ.) COLD START, 60A/230VAC LINE REGULATION ±5% LINE REGULATION ±5% LOAD REGULATION ±5% LOAD REGULATION ±5% SETUP, RISE TIME ≤1S at full load (cold start, power on) SETUP, RISE TIME ≤1S at full load (cold start, power on) RIPPLE <1V RIPPLE <4V SHORT CIRCUIT Hiccup mode, recovers automatically after fault condition is removed SHORT CIRCUIT Hiccup mode, recovers automatically after fault condition is removed OVER VOLTAGE 110-130% Vout, recovers automatically after fault condition is removed OVER VOLTAGE 110-130% Vout, recovers automatically after fault condition is removed OPERATING Temperature -30°C ~ +50°C, Humidity 20 ~ 90% RH non-condensing OPERATING Temperature -30°C ~ +50°C, Humidity 20 ~ 90% RH non-condensing STORAGE Temperature -40°C ~ +80°C, Humidity 10 ~ 90% RH STORAGE Temperature -40°C ~ +80°C, Humidity 10 ~ 90% RH SAFETY STANDARDS Design refer to EN61347-1, EN61347-2-13 SAFETY STANDARDS Design refer to EN61347-1, EN61347-2-13 EMC Compliance to EN55015, EN61000-3-2, 3, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547 EMC Compliance to EN55015, EN61000-3-2, 3, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547 MTBF 400K hours min. refer to MIL-HDBK-217F (25°C) MTBF 400K hours min. refer to MIL-HDBK-217F (25°C) INPUT OUTPUT PROTECTION ENVIRONMENT * Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=230VAC SAFETY * Unless otherwise specified, all the above parameters are measured at ambient temperature of 25°C and Vin=230VAC MECHANICAL SPECIFICATION 22 LL SERIES MECHANICAL SPECIFICATION Dimensions in mm Dimensions in mm Weight: 300g Weight: 305g 23