Data Record for Used Industrial Steam Turbines / Turbosets Turbine Machine No.: Original Equipment Manufacturer (OEM): STE Year of manufacture: 2010 Turbine model: SST-110 (CA36kGT6) Design output (MW) [at best turbine efficiency]: 3.6972/3.579 Maximum output (MW): 3.697/3.579 Steam consumption at design output (kg/kWh): 4.87 Steam consumption at max. output (kg/kWh): 4.87 1) _ Max. main steam temperature (°C) : 420 Main steam temperature (°C)1): 400 Main steam pressure (bar g)1): 40 Main steam flow (t/h)1): 18 Exhaust steam temperature (°C)1): 54 Exhaust steam flow (t/h)1): 18 Exhaust steam pressure (bar): -0.85 Extraction pressure (bar g)2): 4.9 Extraction flow (t/h)2): 0 – 1.5 Speed (rpm): 1,500 Allowable frequency range (Hz): unknown Direction of rotation: right Exhaust steam nozzle (downward, upward, right, left or axial): axial Non-drive end of turbine (HP/LP end): Package (yes/no), if yes, please state configuration (turbine, gear unit, generator, compressor): series TWIN steam turbine (HP+LP) – integral gear – generator – flexible coupling between turbine & generator – HP steam separator – condenser – turbine bypass station – exh. steam pipework betw. turbine & condenser – Control/Monitoring Panel In case of package, is integral lube oil system provided? (yes/no): yes or extract from Operating Manual Load points 1 Main steam parameters 3 40 bar/400 Grad C Main steam flow (t/h) 18.0 Extraction pressure (bar) 4.0 Extraction flow (t/h) 0 to 1.5 Exh. steam pressure (bar) Exh. steam temp. (°C) 2 -0.85 1) 54 Terminal output (kW) 3579 Turbine condition Last minor overhaul: N/A Last major overhaul: N/A Operating hours: None Date of turbine shutdown and preservation details: equipment was never installed - mothballed after manufacture Expected to be available as from: Now 1) in accordance with turbine design 2) where applicable Siemens AG Power Generation Services Division; Leitung: Randy Zwirn Distributed Generation and Compressors; Leitung: Willibald Meixner Frankenstr. 70-80 90461 Nürnberg Deutschland Tel.: +49 (911) 4130 0 Fax: +49 (911) 4130 440 Siemens Aktiengesellschaft: Vorsitzender des Aufsichtsrats: Gerhard Cromme; Vorstand: Joe Kaeser, Vorsitzender; Roland Busch, Lisa Davis, Klaus Helmrich, Hermann Requardt, Siegfried Russwurm, Ralf P. Thomas Sitz der Gesellschaft: Berlin und München, Deutschland; Registergericht: Berlin Charlottenburg, HRB 12300, München, HRB 6684 WEEE-Reg.-Nr. DE 23691322 SCF 10/2014 V13.06 Seite 1 von 3 Are spare parts available? If yes, which ones? No spares sold with turbine. Turbine control and protection system SC900/ST800 Original Equipment Manufacturer (OEM): Siemens Hydraulic or electronic: electronic Overspeed protection system (hydraulic [bolt]/electronic): electronic Axial shaft position monitoring system (hydraulic [nozzle]/electronic): electronic Vibration monitoring system (yes/no): no Actuators for control and stop valve(s) (HP/LP hydraulic system): HP – SS160 Stop Valve/R100 for the 3 control valves; LP – RS160 Magnet wheel installed on turbine shaft (yes/no, if yes, please state number of teeth): yes/unknown Electrohydraulic converter installed (yes/no): yes Condenser: Cooling medium: 70% water/30% glycol Original Equipment Manufacturer (OEM): Hamworthy Serck Como GmbH Condensing capacity (t/h): 18.0 3 Condenser model: AA 43 CD 32/44 J5K 282-1 Condenser pressure (bar): -0.85 Cooling water flow (m /h): 720 Cooling water/glycol velocity (m/s): 1.25 Cooling water inlet temperature (°C): 25 Thermal capacity (MW): 11.116 Supply lines: NW 300 (cooling water) Steam – NW800 Complete operating documentation available (yes/no): yes Complete machine file available (yes/no): Equipment never installed Is the driven machine also available for purchase (yes/no): yes (Generator) SCF 10/2014 V13.06 Seite 2 von 3 Driven generator Machine No.: Original Equipment Manufacturer (OEM): Siemens Rating (MVA): 4.634 Generator type (cooling system): IC 81W Generator model: 1DU1233-8AE02-Z Voltage (kV): 11 Frequency (Hz): 50 Current (A): 243 Power factor (cos phi): 0.8 Speed (rpm): 1500 Design: B3 Insulation class: F Type of enclosure: IP54 Cooling water inlet temperature (°C): 30 Cooling water flow (m 3/h): 15.5 Compound excitation (… V - … A): Generator condition Last minor overhaul: Last major overhaul: Operating hours: Date of turbine shutdown and preservation details: Expected to be available as from: Gear unit: Integral Gear Original Equipment Manufacturer (OEM): STE Gear unit model: GT6 Rating (HP): 4956 Speed (rpm): LSS 1500 rpm Complete scope of supply available for purchase: · Series Twin Turbine – HP+LP Configuration – SST-110 (CA36kGT6) · Integral Gearbox – GT6 · Generator · Flexible Coupling between Turbine and Generator · Condenser · Inlet Steam Separator · Turbine Bypass – Pressure reducing desuperheating system · Crossover pipework between turbine exhaust and condenser · Control/Monitoring Panel Size (footprint) / dimensions: Approx. L 5500mm/W 3550mm/H 3650mm Please provide photographs of the turboset / turbine separately in electronic form. SCF 10/2014 V13.06 Seite 3 von 3