Download Datasheet STE Steam Turbine SST-110 (PDF).

Data Record for Used Industrial Steam Turbines / Turbosets
Turbine
Machine No.:
Original Equipment Manufacturer (OEM): STE
Year of manufacture: 2010
Turbine model: SST-110 (CA36kGT6)
Design output (MW)
[at best turbine efficiency]: 3.6972/3.579
Maximum output (MW): 3.697/3.579
Steam consumption at design output (kg/kWh): 4.87
Steam consumption at max. output (kg/kWh): 4.87
1)
_
Max. main steam temperature (°C) : 420
Main steam temperature (°C)1): 400
Main steam pressure (bar g)1): 40
Main steam flow (t/h)1): 18
Exhaust steam temperature (°C)1): 54
Exhaust steam flow (t/h)1): 18
Exhaust steam pressure (bar): -0.85
Extraction pressure (bar g)2): 4.9
Extraction flow (t/h)2): 0 – 1.5
Speed (rpm): 1,500
Allowable frequency range (Hz): unknown
Direction of rotation: right
Exhaust steam nozzle (downward, upward, right, left or axial): axial
Non-drive end of turbine (HP/LP end):
Package (yes/no), if yes, please state configuration (turbine, gear unit, generator, compressor): series TWIN
steam turbine (HP+LP) – integral gear – generator – flexible coupling between turbine & generator – HP steam
separator – condenser – turbine bypass station – exh. steam pipework betw. turbine & condenser –
Control/Monitoring Panel
In case of package, is integral lube oil system provided? (yes/no): yes
or extract from Operating Manual
Load points
1
Main steam parameters
3
40 bar/400 Grad C
Main steam flow (t/h)
18.0
Extraction pressure (bar)
4.0
Extraction flow (t/h)
0 to 1.5
Exh. steam pressure (bar)
Exh. steam temp. (°C)
2
-0.85
1)
54
Terminal output (kW)
3579
Turbine condition
Last minor overhaul: N/A
Last major overhaul: N/A
Operating hours: None
Date of turbine shutdown and preservation details: equipment was never installed - mothballed after manufacture
Expected to be available as from: Now
1) in accordance with turbine design
2) where applicable
Siemens AG
Power Generation Services Division; Leitung: Randy Zwirn
Distributed Generation and Compressors; Leitung: Willibald Meixner
Frankenstr. 70-80
90461 Nürnberg
Deutschland
Tel.: +49 (911) 4130 0
Fax: +49 (911) 4130 440
Siemens Aktiengesellschaft: Vorsitzender des Aufsichtsrats: Gerhard Cromme; Vorstand: Joe Kaeser, Vorsitzender;
Roland Busch, Lisa Davis, Klaus Helmrich, Hermann Requardt, Siegfried Russwurm, Ralf P. Thomas
Sitz der Gesellschaft: Berlin und München, Deutschland; Registergericht: Berlin Charlottenburg, HRB 12300, München, HRB 6684
WEEE-Reg.-Nr. DE 23691322
SCF 10/2014 V13.06
Seite 1 von 3
Are spare parts available? If yes, which ones?
No spares sold with turbine.
Turbine control and protection system SC900/ST800
Original Equipment Manufacturer (OEM): Siemens
Hydraulic or electronic: electronic
Overspeed protection system (hydraulic [bolt]/electronic): electronic
Axial shaft position monitoring system (hydraulic [nozzle]/electronic): electronic
Vibration monitoring system (yes/no): no
Actuators for control and stop valve(s) (HP/LP hydraulic system):
HP – SS160 Stop Valve/R100 for the 3 control valves; LP – RS160
Magnet wheel installed on turbine shaft (yes/no, if yes, please state number of teeth): yes/unknown
Electrohydraulic converter installed (yes/no): yes
Condenser: Cooling medium: 70% water/30% glycol
Original Equipment Manufacturer (OEM):
Hamworthy Serck Como GmbH
Condensing capacity (t/h): 18.0
3
Condenser model: AA 43 CD 32/44 J5K 282-1
Condenser pressure (bar): -0.85
Cooling water flow (m /h): 720
Cooling water/glycol velocity (m/s): 1.25
Cooling water inlet temperature (°C): 25
Thermal capacity (MW): 11.116
Supply lines: NW 300 (cooling water) Steam – NW800
Complete operating documentation available (yes/no): yes
Complete machine file available (yes/no): Equipment never installed
Is the driven machine also available for purchase (yes/no): yes (Generator)
SCF 10/2014 V13.06
Seite 2 von 3
Driven generator
Machine No.:
Original Equipment Manufacturer (OEM): Siemens
Rating (MVA): 4.634
Generator type (cooling system): IC 81W
Generator model: 1DU1233-8AE02-Z
Voltage (kV): 11
Frequency (Hz): 50
Current (A): 243
Power factor (cos phi): 0.8
Speed (rpm): 1500
Design: B3
Insulation class: F
Type of enclosure: IP54
Cooling water inlet temperature (°C): 30
Cooling water flow (m 3/h): 15.5
Compound excitation (… V - … A):
Generator condition
Last minor overhaul:
Last major overhaul:
Operating hours:
Date of turbine shutdown and preservation details:
Expected to be available as from:
Gear unit: Integral Gear
Original Equipment Manufacturer (OEM): STE
Gear unit model: GT6
Rating (HP): 4956
Speed (rpm): LSS 1500 rpm
Complete scope of supply available for purchase:
·
Series Twin Turbine – HP+LP Configuration – SST-110 (CA36kGT6)
·
Integral Gearbox – GT6
·
Generator
·
Flexible Coupling between Turbine and Generator
·
Condenser
·
Inlet Steam Separator
·
Turbine Bypass – Pressure reducing desuperheating system
·
Crossover pipework between turbine exhaust and condenser
·
Control/Monitoring Panel
Size (footprint) / dimensions:
Approx. L 5500mm/W 3550mm/H 3650mm
Please provide photographs of the turboset / turbine separately in electronic form.
SCF 10/2014 V13.06
Seite 3 von 3