MS-Series Circuit Breaker Datasheet [pdf]

MS-Series
MS-Series
CIRCUIT BREAKER
Designed and tested to operate flawlessly in the harshest of environments, the MS-Series sealed toggle circuit
breaker is ideally suited for COTS (commercial off the shelf) military applications. Our space saving envelope
meets IP68 requirements and features a durable metal and sealed mounting bushing with MIL-PRF-39019F
ingress protection when mounted in a panel.
This class-leading, affordable circuit breaker was designed in accordance with the requirements of MILPRF-55629 and MIL STD 202, making it the best choice for those applications where shock, vibration, moisture
resistance, salt spray and thermal shock are of the utmost consideration. The MS-Series’ compact size and
reliability make it ideal for crucial communication equipment and other mission critical components.
1-3 poles; 0.20-30 amps; 65VDC, 240VAC, 120/240VAC; UL, CUL recognized & TUV pending.
Resources:
Download 3D CAD Files
IGS
STP
Watch Product Video
Product Highlights:
Sealed Toggle Actuator
MIL-PRF-39019F Ingress Protection
ŠŠ MIL-PRF-55629 and MIL STD 202
Compliant
ŠŠ Compact Design
ŠŠ
ŠŠ
Typical Applications:
COTS Military
• Communication Equipment
ŠŠ Off Highway Equipment
• Construction, Mining & Agriculture ŠŠ Generators & Power Supplies
ŠŠ Harsh Environment Applications
ŠŠ
Carling Technologies, Inc.
60 Johnson Avenue, Plainville, CT 06062
Email: [email protected]
Application Support: [email protected]
Phone: 860.793.9281 Fax: 860.793.9231
www.carlingtech.com
2 | MS-Series Circuit Breaker - Design Features
MS-Series
DESIGN FEATURES
SEALS
IP68 Designed and tested to comply
with MIL-PRF-39019F Ingress Protection
COMPACT SIZE
Max performance in compact size: 0.20-30
Amps; 65 VDC, 240 VAC 120/240 VAC
1.375 in
[34.93 mm]
0.65 in
[16.51 mm]
TERMINAL BARRIERS
Meet UL 1077 Spacing Requirements
2.158 in
[54.81 mm]
OPTIONAL AUXILIARY SWITCH
Provides Breaker Status Indication
Email: [email protected] Application Support: [email protected]
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
MS-Series Circuit Breaker - General Specifications | 3
Electrical Tables
Table A: Lists UL & cUL Configuration & Performance Capabilities
MS-SERIES TABLE A: COMPONENT SUPPLEMENTARY PROTECTORS
Short Circuit
Capacity (Amps)1
UL / cUL
Circuit Configuration Max Rating Frequency Phase General Purpose Amps Poles Breaking
U1
U3
65
DC
--0.02 - 30
1
3000
300
Series
240
50 / 60
1
0.02 - 30
1, 2
2000
300
120 / 240
50 / 60
1
0.02 - 30
2 or 3
2000
300
Voltage
Current Rating
Notes:
1 Short Circuit Current Rating (SC) Codes — The short-circuit current rating, followed by a letter and number designating the test conditions and any calibration following the short-circuit test as defined below:
U - Indicates that the short circuit test was performed without a series fuse
1 - Indicates that a re-calibration was not performed as part of the short circuit testing
3 - Indicates that the protector has proven to be suitable for further use after the short circuit test
Re-calibration, dielectric strength and voltage withstand tests were performed after the short circuit testing
Electrical
Current Ratings
.02 - 30 Amps
Voltage Rating
65VDC, 240VAC, 120/240VAC
Short Circuit Rating
See Table A
Auxiliary Switch Rating
5A @ 125VAC,
3A @ 32VDC,
.1A @ 125VAC, 32VDC
Dielectric Strength
UL,CSA 1500V, 50/60 Hz for one
minute between all electrically
isolated terminals.
Insulation Resistance
Minimum of 100 Megohms @
500VDC
Time Delay
See delay curve
Impedance
CURRENT
TOLERANCE
(AMPS)
(%)
0.20 - 30.0
25
Physical
Number of Poles
1-3 poles
Weight
Approximately 1.8 oz (50 G) per pole
Dimensions
See form & fit drawing
Agency Certifications
UL Standard 1077
Mechanical
Current Ratings
10,000 On-Off operations @ 6 per
minute with rated current and
voltage.
Trip Free
Trips on short circuit and overload, even when the actuator is forcibly held in the “On” position.
Trip Indication The operating handle moves
positively to the “Off” position
when a short circuit or overload causes the circuit breaker to trip.
Environmental
Designed in accordance with requirements of specification
MIL PRF-55629 & MIL-STD-202G as follows:
Shock
Withstands 100G’s, 6ms, saw
tooth while carrying rated current per Method 213, Condition I. Instantaneous curves tested at 80% of rated current.
Vibration
Withstands 0.060” excursion from 10-55 Hz, and 10G’s 55-500 Hz, at rated current per Method
204C, Test Condition A. Instantaneous curves tested at 80% of rated current.
Salt Spray
Method 101, Condition A (90-
95% RH @ 5% NaCl Solution, 96 hrs)
Moisture Resistance
Method 106G
Thermal Shock
Method 107D, Condition A (Five cycles @ -55°C to +25°C to +85°C to +25°C
Operating Temperature -40°C to +85°C
Ingress Protection Level MIL-PRF-55629C when mounted in panel.
Other
Materials used in this product are non-nutrient to fungus growth.
CUL Standard C22.2
*Manufacturer reserves the right to change product specification without prior notice.
Email: [email protected] Application Support: [email protected]
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
4 | MS-Series Circuit Breaker - Ordering Scheme
M S 1
1
Series
2
Actuator
3
Poles
B
14
615
4
Circuit
5
Frequency
& Delay
6
Current
Rating
C
7
Terminal
1 C B
8
Actuator
Color
9
10
Front
Legend
Panel
Plate
Hardware
A 0A A
11
Bushing
Color
7 TERMINAL
1 Push-On 0.250 Tab (QC)
2 Screw 8-32 (Upturned Lugs)
3 Screw 8-32 (Bus Type)
C Screw Terminal M4 (Upturned Lugs)
E Screw Terminal M4 (Bus Type)
L Solder Lug
1 SERIES
M
2 ACTUATOR
S Sealed Toggle
3 POLES
1 One
2Two
8 ACTUATOR & MARKING COLOR
1 Dull Metallic
3Three
4 CIRCUIT
A Switch Only (no coil) 1, 2
B Series Trip (current)
M Series Trip (current) Aux switch .110 QC x 0.20 QC (silver contacts)
9 Series Trip (current) Aux switch .110 QC x 0.20 QC (gold contacts)
5 FREQUENCY & DELAY
03 DC, 50/60 Hz, Switch Only 1
10 DC, Instantaneous
12 DC, Short
14 DC, Medium
20 50/60 Hz Instantaneous
22 50/60 Hz Short
24 50/60 Hz Medium
30 DC, 50/60 Hz Instantaneous
32
34
62
64
72
74
92
94
DC, 50/60 Hz Short
DC, 50/60 Hz Medium
50/60 Hz Short, Hi-Inrush 4
50/60 Hz Medium, Hi-Inrush 4
DC, Short, High-Inrush 4
DC, Medium, High-Inrush 4
DC, 50/60 Hz Short, Hi-Inrush 4
DC, 50/60 Hz Medium, In-rush 4
9 FRONT PANEL HARDWARE
A No Outer Panel Hardware
B Hex Nut, Nickel Plated
C Hex Nut, Nickel Plated with Locking Ring
F Panel Dress Nut, Nickel Plated
G Panel Dress Nut, Nickel Plated with Locking Ring
10 LEGEND PLATE
A No Legend Plate
B On-Off Vertical
C On-Off Horizontal
D I-O Vertical
E I-O Horizontal
F Dual Vertical
G Dual Horizontal
6 CURRENT RATING (AMPERES)
CODEAMPERES
220 0.200 225 0.250 230 0.300
235 0.350
240 0.400
2450.450
250 0.500
255 0.550 260 0.600
265 0.650
270 0.700
275 0.750
280 0.800
285 0.850 290 0.900
295
410
512
415
517
420
522
425
527
430
435
440
445
450
455
0.950
1.00
1.25
1.50
1.75
2.00
2.25
2.50
2.75
3.00
3.50
4.00
4.50
5.00
5.50
460
465
470
475
480
485
490
495
610
710
611
711
612
712
613
6.00
6.50
7.00
7.50
8.00
8.50
9.00
9.50
10.00
10.50
11.00
11.50
12.00
12.50
13.00
614
615
616
617
717
618
619
620
622
624
625
630
14.00
15.00
16.00
17.00
17.50
18.00
19.00
20.00
22.00
24.00
25.00
30.00
11 BUSHING COLOR
A Nickel Plated / Multipole Version
12 VOLTAGE CODE
0A 65 VDC
0D 240 VAC
0C 120/240 VAC 3
0N 65 VDC / 120/240 VAC 3
17 65 VDC / 240 VAC
13 AGENCY APPROVAL
A Without approvals
B UL Recognized
C UL & cUL Recognized
Notes:
1 Series code “A” only available with delay code “03”
2 Only available when tied to a protected pole
3 Requires a 2 or 3 pole device
4 Only available without agency approvals (Approval Code A)
Email: [email protected] Application Support: [email protected]
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
12
Voltage
Code
13
Agency
Approval
MS-Series Circuit Breaker - Dimensional Specifications | 5
Dimensional Specifications: in. [mm]
Notes:
1 All dimensions are in inches [millimeters].
2 Tolerance ±.020 [.51] unless otherwise specified.
Email: [email protected] Application Support: [email protected]
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
6 | MS-Series Circuit Breakers - Time Delay Values
,
Notes:
1
2
3
4
Delay Curves 12,14, 22, 24, 32, 34, 62, 64, 72, 74, 92, 94: Breakers to hold 100% and must trip at 135% of rated current and greater within the time limit shown in this curve.
Delay Curves 10, 20, 30: Breakers to hold 100% and must trip at 150% of rated current and greater within the time limit shown in this curve.
All Curves: Curve data shown represents breaker response at ambient temperature of 77°F (25°C) with no preloading. Breakers are mounted in standard wall-mount position.
The minimum inrush pulse tolerance handling capability is 12 times the rated current on standard delays and 18 times the rated current on high inrush delays. These values are based on a 60 Hz 1/2 cycle,
8.33 ms pulse. High inrush delays should be specified for applications with high initial surge currents of short duration, such as switching power supplies, highly capacitive loads and transformer loads.
Instantaneous
Dual Rated AC/DC
Short
Short D2
Medium
Medium D4
Email: [email protected] Application Support: [email protected]
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
Reps & Contact | 7
Authorized Sales Representatives
Click on the group name on the map below to find your local representative or visit
www.carlingtech.com/findarep.
«
«
Matera
W. Canada
Matera
E. Canada
MIDWEST
DM
Michigan
TEMCO Northwest
Alaska, Hawaii
«
NORTHERN
Hanna Lind Ltd.
Melody
Emery
Sierra
Bridge Marketing
Omega Limited
Dy-tronix Inc.
LD. Allen
Norris
DM Assoc
East
Pacent
DM
Assoc
TSI North
TSI
WEST
Signal
Enterprises
Luscombe
Engineering
Pinnacle Marketing
Matrix
DM Mexico
South America
Mexico
«
«
Sunbelt Components
SOUTHEAST
ProRep
Solutions
LATIN AMERICA
Americas
Europe
Middle East
Africa
Asia-Pacific
Oceania
About Carling
Founded in 1920, Carling Technologies is a leading manufacturer of electrical and electronic switches
and assemblies, circuit breakers, electronic controls, power distribution units, and multiplexed power
distribution systems. With four ISO registered manufacturing facilities and technical sales offices worldwide,
Carling Technologies Sales, Service and Engineering teams do much more than manufacture electrical
components, they engineer powerful solutions! To learn more about Carling please visit
www.carlingtech.com/company-profile.
To view all of Carling’s environmental, quality, health & safety certifications please visit
www.carlingtech.com/environmental-certifications
Email: [email protected] Application Support: [email protected]
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
Worldwide Headquarters
Carling Technologies, Inc.
60 Johnson Avenue, Plainville, CT 06062
Phone: 860.793.9281 Fax: 860.793.9231
Email: [email protected]
Northern Region Sales Office: [email protected]
Southeast Region Sales Office: [email protected]
Midwest Region Sales Office: [email protected]
West Region Sales Office: [email protected]
Latin America Sales Office: [email protected]
Asia-Pacific Headquarters
Carling Technologies, Asia-Pacific Ltd.,
Kowloon, Hong Kong
Phone: Int + 852-2737-2277 Fax: Int + 852-2736-9332
Email: [email protected]
Shenzhen, China: [email protected]
Shanghai, China: [email protected]
Pune, India: [email protected]
Kaohsiung, Taiwan: [email protected]
Yokohama, Japan: [email protected]
Europe | Middle East | Africa Headquarters
Carling Technologies LTD
4 Airport Business Park, Exeter Airport,
Clyst Honiton, Exeter, Devon, EX5 2UL, UK
Phone: Int + 44 1392.364422 Fax: Int + 44 1392.364477
Email: [email protected]
Germany: [email protected]
France: [email protected]
www.carlingtech.com
REV_01_2016