Rotary V-Series CONTURA ROTARY SWITCHES The V-Series Contura Rotary Switch was designed for maximum performance and reliability leveraging the features of the widely popular V-series Contura Rocker Switches. Available in maintained and momentary circuit options, the V-Series Rotary features a sturdy knob construction, up to three separate LEDs, and fits in an industry standard panel opening. Internally, the V-Series Contura Rotary uses a patented mechanism that translates rotary to linear motion. This allows for common switch functionality and terminal connections with the V-Series rocker version and requires no harness change. A secondary CAM, which helps drive the mechanism, provides definitive detent positions and prevents the switch from stopping between positions, while improving tactile feel. The V-Series Rotary also features an innovative PC board that supports the LED and surface mount resistors; and IP67 sealing protection above panel by utilizing LED and actuator stem seals. Together, these features make the V-Series Contura Rotary switch the best choice available in the market today. Resources: Download 3D CAD Files IGS STP Watch Product Video Product Highlights: Accommodates up to three separate LEDs Patented mechanism translates rotary into linear motion Secondary CAM for definitive detent positions PC Board supports LED and surface mount resistors IP67 sealing protection above panel Common terminal & circuit functionality with V-Series Rocker switches, with no harness change required Typical Applications: On/Off Highway Equipment Marine Test & Measurement Instrumentation Speed Control Carling Technologies, Inc. 60 Johnson Avenue, Plainville, CT 06062 Email: [email protected] Application Support: [email protected] Phone: 860.793.9281 Fax: 860.793.9231 www.carlingtech.com 2 | V-Series Contura Rotary Switch - Design Features V-Series Rotary Switch DESIGN FEATURES OPTIONAL PANEL SEAL Prevents water/dust ingress behind panel LEDS Up to three separate LEDs SEALS LED and stem seals provide IP67 protection above panel ROTARY & LINEAR ACTUATOR Patented mechanism that translates rotary to linear motion PC BOARD Supports LEDs and surface mount resistors TERMINALS Same pinout as V-Series Rocker Switches, requiring no harness change SECONDARY CAM Provides definitive detent positions with ball & spring located in rotary actuator Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com V-Series Contura Rotary Switch - General Specifications | 3 Electrical Mechanical Rating Circuit Voltage Max Current Resistive 2 Position Maintain 2 Position Momentary 3 Position All 2 Position Maintain 2 Position Momentary 12 12 12 24 24 20 20 20 15 15 3 Position All 24 15 Dielectric Strength 1500 Volts RMS Insulation Resistance 50 Megohms Initial Contact Resistance 10 Milli Ohm max @ 4VDC Life 50,000 Cycles Two Position 25,000 Cycles Two Position Momentary and All Three position Terminals 0.250” (6.3mm) Quick Connect Physical Function Circuits Double Pole Single Throw, DPST Double Pole Double Throw, DPDT Operation Two and Three Position Maintained and Momentary Knob Rotation Two Position 60 Degrees Three Position 30 Degrees from Center Illumination LED; Red, Green, Amber, Yellow, White, Blue Seals LED O-ring(s) – Silicone, Bezel gasket – Neoprene, Knob seal - NBR Flammability Exceeds FVMSS 302 Requirements, Exterior Components, UL 94 V-2 or Better Interior Components, UL 94 HB or Better Base Polyester, PBT Bracket Nylon 66, PA Knob Polybutylene Terephthalate, PBT 6.5%GF Lens Polycarbonate, PC Connector Nylon 66, PA Mounting Front Panel Snap In, 1.450” (36.83mm) X 0.830” (21.08mm) Panel Thickness, 0.030” – 0.187” (0.76 – 4.75mm) Mechanical Life Knob Impact Environmental Sealing Dust Corrosion Chemical Splash Salt Spray Vibration Random Vibration Sinusoidal Shock Handling Shock Thermal Shock Moisture Resistance Thermal Cycling Ignition Protection UV Protection ESD 100,000 Cycles Maintained Circuits 50,000 Cycles Momentary Circuits 50 Gram weight dropped from a height of 18 inches on Top & Sides IP67, in accordance with IEC 60529, BS 5490, DIN 40050 & NFC 20 010. This rating applies to front panel components of the actual switch only, and signifies protection against dust and the prolonged effects of immersion under pressure. Mil STD 810, Method 510.2 Air Velocity 300 Ft/Min Duration 16Hr IEC 68-2-60 Mixed Flowing Gas (MFG) 14 Days Gasoline, Diesel, Motor Oil, Brake Fluid, Ammonia, Armour All Mil STD 202G, Method 101, Test Condition A 96 Hr Mil STD 202G, Method 214 test Condition C 10G’s RMS Mil STD 202G, Method 204D, Test Condition A 0.06DA or 10G’s 10-500Hz MIL-STD 202G, Method 213B Test Condition K, 30G’s 1 Meter Drop onto Hard Surface MIL-STD 202G, Method 107G Test Condition A -55 C to 85 C MIL-STD 202G, Method 106F 10, 25 C to 65 C Cycles 95% RH 25 Cycles -40 C to 85 C ISO 8846 with EC Directive 94/25/EC for Marine Products 300 hr Xenon Arc, 1.4W/m2 wavelength 420 nm Human Static Discharge, +/- 15KV applied during normal operation Shipping/Handling, frequency range 200-2000 MHz applied voltage is +8KV to +15KV and -8KV to -15KV 3 discharge cycles *Manufacturer reserves the right to change product specification without prior notice. Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com 4 | V-Series Contura Rotary Switch - Ordering Scheme RV 21 D 2 B 6 0 0 B 1 Series 2 Circuit 3 Rating 4 5 6 Termination Illumination Lamp 1 1 SERIES RV Rotary Contura 2 CIRCUIT 1 Terminal Connections as viewed ( ) - momentary from bottom of switch: 8 - - 7 DP - double pole uses 1, 2, 3 and 4, 5, 6. 1 - - 4 2 - - 5 3 - - 6 10 - - 9 Position:1 2 3 DP 2 & 3, 5 & 6 Connected Terminals 1 & 2, 4 & 5 21 ON NONE OFF 22 (ON) NONE OFF 23 ON NONE(OFF) 24 ON NONE ON 26 ON OFF ON 28 (ON) OFF (ON) SPECIAL CIRCUITS 55 (ON) OFF ON 61 2 & 3, 5 & 6 2 & 3, 4 & 5 1 & 2, 4 & 5 62 2 & 3, 5 & 6 2 & 3 OFF 64 (2 & 3, 5 & 6) 2 & 3 OFF 3 RATING 1 .4VA 28VDC Resistive B 15A 24V D 20A 12V 4 TERMINATION / BASE STYLE 8 Term 10 Term TerminationJumper 1 2 .250 TAB (QC) - no barriers No AB .250 TAB (QC) - with barriers No 4, 5 4, 5 J K .250 TAB (QC) - no barriers Yes (T2 to T5) Notes: 1 Switch circuit uses terminals 1,2,3,4,5 & 6. Terminals 7,8,9 & 10 are for lamp circuit only. 2 Jumper between terminals 2 & 5 for Circuits 61, 62, & 64 to be specified in the Termination & Jumper selection. 3 Circuit 61 may be used for SP, OFF-ON-ON circuit. 4 Base will not have terminal insulating barriers when connector and/or jumpers are used. 5 Code J,K are optional for circuits 62 and 64. Customer may provide externally wired jumper to connect terminals 2 and 5. 6 Lamp #1 located at top end of switch, above terminal 4. Lamp #2 located at top end of switch between terminals 1 & 4. Lamp #3 located at top end of switch, above terminal Positive (+) and negative (-) symbols apply to L.E.D. lamps only. 7 Mounting hole size is 1.450” (36.83mm) by 0.830” (21.08mm). To mount multiple switches in single panel cut-out order optional interlocking mounting panels. 8 Lens color for L.E.D.s must be clear, white, or match color of L.E.D. 7 Lamp 2 8 Lamp 3 9 Bracket 5 ILLUMINATION 6, 8 Sealed Lamps S NONE A # 1 B # 1 C # 1 & # 3 D # 1 & # 3 E # 1 # 2 # 3 F # 1 # 2 # 3 G # 1 # 3 H # 2 J # 1 # 2 K # 1 # 2 L # 1 # 2 M # 2 # 3 N # 2 # 3 P # 2 # 3 R # 3 T # 3 K R C 10 Actuator 11 Lens 12 Knob Color when illuminated Terminals Independent Dependent Independent Independent Dependent Dependent Independent Independent Independent Dependent Independent Dependent Dependent Independent Independent Independent Independent Dependent Dependent Dependent Independent Independent Independent Dependent Dependent Independent Dependent Independent Dependent 8+ 3+ 8+ 10+ 3+ 1+ 8+ 9+ 10+ 3+ 9+ 1+ 3+ 8+ 8+ 8+ 10+ 3+ 1+ 3+ 8+ 8+ 10+ 3+ 1+ 10+ 1+ 8+ 1+ 77777777777777777777777777777- 6, 7, 8 LAMP #1, 2 AND OR LAMP #3 6, 8 Selection 6: above terminal 7; Selection 8: above terminal 8 No lamp 0 LED RedAmber Green Blue White 12VDC CN H E 6 24VDC DP J K 8 9 BRACKET COLOR & PANEL SEAL 7 Color No Gasket 1 Gasket 2 Gasket Black BC D Gray GH J White WY Z 10 ACTUATOR STYLE K Rotary Knob (Standard) ACTUATOR ORIENTATION ABOVE TERMINALS 4 1 11 LENS COLOR 8 No Lens Z Clear WhiteAmber Green Red Blue 4 9E KRW 12 KNOB COLOR Black GrayRed White C HS Y Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com V-Series Contura Rotary Switch - Dimensional Specifications | 5 Dimensional Specifications: in. [mm] 1.400 [35.56] 1.700 [43.18] .845 [21.47] 1.079 [27.40] 1.550 [39.37] 10 TERMINAL BASE W/ BARRIERS .960 [24.38] 1.126 [29.24] .250 [6.35] X .031[.78] .353 [8.64] .820 [20.83] .960 [24.38] 10 TERMINAL BASE W/O BARRIERS 8 7 1 4 2 5 3 6 10 9 BOTTOM VIEW TERMINAL ARRANGEMENT 10 TERMINAL BASE SWITCH SHOWN WITH VC1 CONNECTOR 10 TERMINAL 1.266 [32.16] 1.318 [33.48] Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com 6 | V-Series Contura Rotary Switch - Circuit Diagrams Circuits Diagrams: LEGEND SYMBOL DEFINITION TERMINAL LOCATION MAINTAINED CIRCUIT MOMENTARY CIRCUIT INTERNAL CONNECTION (JUMPER TERMINAL) 2 POSITION CONNECTION 2 POSITION CONNECTION P1 P3 2 POSITION P1 P2 P3 3 POSITION Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com V-Series Contura Rotary Switch - Lamp Circuit Diagrams | 7 Lamp Circuit Diagrams: Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com 8 | Notes Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Reps & Contact | 9 Authorized Sales Representatives Click on the group name on the map below to find your local representative or visit www.carlingtech.com/findarep. « « Matera W. Canada Matera E. Canada MIDWEST DM Michigan TEMCO Northwest Alaska, Hawaii « NORTHERN Hanna Lind Ltd. Melody Emery Sierra Bridge Marketing Omega Limited Dy-tronix Inc. LD. Allen Norris DM Assoc East Pacent DM Assoc TSI North TSI WEST Signal Enterprises Luscombe Engineering Pinnacle Marketing Matrix DM Mexico South America Mexico « « Sunbelt Components SOUTHEAST ProRep Solutions LATIN AMERICA Americas Europe Middle East Africa Asia-Pacific Oceania About Carling Founded in 1920, Carling Technologies is a leading manufacturer of electrical and electronic switches and assemblies, circuit breakers, electronic controls, power distribution units, and multiplexed power distribution systems. With four ISO registered manufacturing facilities and technical sales offices worldwide, Carling Technologies Sales, Service and Engineering teams do much more than manufacture electrical components, they engineer powerful solutions! To learn more about Carling please visit www.carlingtech.com/company-profile. To view all of Carling’s environmental, quality, health & safety certifications please visit www.carlingtech.com/environmental-certifications Email: [email protected] Application Support: [email protected] Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com Worldwide Headquarters Carling Technologies, Inc. 60 Johnson Avenue, Plainville, CT 06062 Phone: 860.793.9281 Fax: 860.793.9231 Email: [email protected] Northern Region Sales Office: [email protected] Southeast Region Sales Office: [email protected] Midwest Region Sales Office: [email protected] West Region Sales Office: [email protected] Latin America Sales Office: [email protected] Asia-Pacific Headquarters Carling Technologies, Asia-Pacific Ltd., Kowloon, Hong Kong Phone: Int + 852-2737-2277 Fax: Int + 852-2736-9332 Email: [email protected] Shenzhen, China: [email protected] Shanghai, China: [email protected] Pune, India: [email protected] Kaohsiung, Taiwan: [email protected] Yokohama, Japan: [email protected] Europe | Middle East | Africa Headquarters Carling Technologies LTD 4 Airport Business Park, Exeter Airport, Clyst Honiton, Exeter, Devon, EX5 2UL, UK Phone: Int + 44 1392.364422 Fax: Int + 44 1392.364477 Email: [email protected] Germany: [email protected] France: [email protected] www.carlingtech.com REV_04_2016