THERMAL Circuit Protection CATALOG • Rocker • Toggle • Pushbutton • Rotary CIRCUIT PROTECTION • Hydraulic-Magnetic • Thermal • GFCI / ELCI CUSTOM SOLUTIONS • PDU’s • Keypads • Control Modules STRATEGIC MARKETS SERVED: On/Off Highway Marine Telecom/Datacom Military Renewable Energy GLOBAL LOCATIONS: ISO9001:2008 ISO/TS16949:2009 ISO9001:2008 ISO/TS16949:2009 ISO9001:2008 ISO/TS16949:2009 ISO14001:2004 ISO9001:2008 ISO/TS16949:2009 ISO14001:2004 ISO9001:2008 ISO/TS16949:2009 ISO14001:2004 ISO9001:2008 ISO/TS16949:2009 COMPETITIVE ADVANTAGES + Vertical Integration ii Reliable & On-Time Delivery Excellent Customer Service MULTIPLEXED POWER SYSTEMS • HMI Devices & I/O Modules • Programmable Displays • Data Communication Interfaces • Electrical Systems Monitoring ..................................................................................................................... SWITCHES & CONTROLS ................... Since its founding, Carling Technologies has continually forged a tradition of leadership in quality and product innovation. ................... 1920 There are few products that Carling Technologies hasn’t turned “ON” and fewer industries that haven’t turned to Carling for solutions. With ISO and TS registered manufacturing facilities and technical sales offices worldwide, Carling ranks among the world’s largest manufacturers of circuit breakers, switches, power distribution units, digital switching systems and electronic controls. ................... FOUNDED IN Innovative & Eco-Friendly Products OTHER SERVED INDUSTRIES: Medical Industrial Control Audio / Visual Commercial Food HVAC Floor Care Generators Small Appliances Security Systems Test & Measurment WORLDWIDE NUMBERS: 2000+ 150+ EMPLOYEES ENGINEERS 70 + 50+ DISTRIBUTORS REP FIRMS www.carlingtech.com Table of Contents 2 C1005B–Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Selector Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Lighted Rocker Thermal Circuit Protection, Ratings up to 16A AC/DC CTB–Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Panel Mount Rocker Thermal Circuit Protection, Ratings up to 15A AC/DC CMB–Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pushbutton Thermal Circuit Protection, Ratings up to 20A AC/DC CLB–Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pushbutton Thermal Circuit Protection, Ratings up to 60A AC/DC CMBA/CLBA–Series. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Auto-Reset Thermal Circuit Protection, Ratings up to 40A AC/DC 5 7 9 11 Thermal Circuit Protectors This catalog features Carling Technologies’ current line of thermal circuit protectors, from 3 to 60 amps, which offer reliable, cost effective circuit protection. Thermal circuit protectors utilize a bimetallic strip electrically in series with the circuit. The heat generated by the current during an overload deforms the bimetallic strip and trips the breaker. Thermal protectors have a significant advantage over fuses in that they can be reset after tripping. They can also be used as the main ON/ OFF switch for the equipment being protected. Typical Applications Include: • Household Appliances • Transportation • Marine • Power Strips • Medical Equipment • Audio Visual Equipment • Power Supplies • Exercise Equipment © 2016 Carling Technologies, Inc. Carling Technologies is a registered trademark of Carling Technologies, Inc. in the U.S. and other countries. www.carlingtech.com 1 Selector Guide C1005B-Series CTB-Series CMB-Series CLB-Series CMBA/CLBA-Series Number of Poles 1 1 1 1 1 Actuator Style rocker, lighted rocker rocker pushbutton pushbutton n/a Max Current & Voltage Ratings 7 to 16A, 125-250VAC, 32VDC 3 to 16A, 125-250VAC, 50VDC 3 to 20A, 125-250VAC, 32 VDC 3 to 60A, 125-250VAC, 32 VDC 3 to 40A, 125-250VAC, 32 VDC Max Interrupting Capacity 1000A 1000A 2500A@32VDC 2500A@32VDC 2500A@32VDC Available Circuits series trip manual reset series trip manual reset series trip manual reset series trip manual reset series trip auto reset Terminal Options .250” tab, solder lug .250” tab .250” tab, .250” tab with 90° bend, screw terminal, screw terminal with 90° bend .250” tab, .250” tab with 90° bend, screw terminal, screw terminal with 90° bend .250” tab, .250” tab with 90° bend Mounting Method front panel snap-in front panel snap-in threaded bushing, front panel snap-in threaded bushing, front panel snap-in plug-in Operating Temperature -10°C to 65°C -10°C to 60°C -10°C to 60°C -10°C to 60°C -10°C to 60°C Agency Approvals UL, CUL, TUV UL, CUL, VDE, CE UL, CUL, CSA, TUV, CE, UL 1500 / ISO 8846 for ignition protection / marine UL, CUL, CSA, TUV, CE, UL 1500 / ISO 8846 for ignition protection / marine UL, CUL, TUV, UL 1500 / ISO 8846 for ignition protection / marine *Manufacturer reserves the right to change product information without prior notice 2 www.carlingtech.com C1005B C1005B-Series - Introduction C1005B-Series THERMAL CIRCUIT PROTECTORS The C1005B-Series offers the functionality of a switch and circuit breaker in a single compact package, which fits an industry standard .550 x 1.125 mounting hole. This combo device eliminates the need for both a switch and thermal circuit protector on customer panels. By using only this multipurpose product, wiring and assembly costs are greatly reduced, while at the same time, valuable panel real estate is saved. The C1005B-Series is available lighted or unlighted, in a variety of colors, with solder lug or .250 tabs. Current ratings range from 7-16 amps@125 and 250 VAC and up to 32 VDC. Product Highlights: .550 x 1.125 mounting hole (14mm x 28.6mm) Ratings from 7-16A Standard Reset/Off Legend Curved Rocker & Angular Bezel .250 Tabs or Solder Lug Terminations 65°C Max Operating Temperature 1000 AIC Interrupting Capacity 1500 VAC Dielectric Strength 100M ohms @500VDC Insulation Resistance Compact Space-Saving Envelope UL1077, UL1363, IEC 60934 Typical Applications: Household Appliances Commercial Appliances Transportation Marine Telecommunications Power Strips Audio-visual Equipment Medical equipment Power supplies Generators www.carlingtech.com 3 C1005B-Series - Ordering Scheme, Time Delay, Dimensional Specifications C1005B 3 B 15 1 B R 3 1 Series 2 3 4 Illumination Termination Current Rating 5 Contact Material 6 Bezel Legend 7 Rocker Color 8 Lamp Voltage 1 SERIES C1005B 5 CONTACT MATERIAL 1 1 Silver Cad Oxide (switch), Silver plated copper (breaker) 2 ILLUMINATION 2 Non-Lighted 3 Lighted 6 BEZEL LEGEND IMPRINT B Black Bezel with white legend W White Bezel with black legend C Gray Bezel with black legend 3 TERMINATION A Solder Lug B .250 Tab 4 CURRENT RATING (AMPERES) 07 7 amps 08 8 amps 09 9 amps 10 10 amps 11 11 amps 12 13 14 15 16 7 ROCKER COLOR R Red G Green U Blue T Clear Note: RESET OFF Legend is standard. 12 amps 13 amps 14 amps 15 amps 16 amps 8 LAMP VOLTAGE 3 Neon Lamp 125/250 VAC 9 Non-lighted Notes: 1. Silver cad oxide switch and breaker contacts are available as a special order. Specify 3 for selection 5 Dimensional Specifications: in. [mm] 1.280 [32.5] 1.125 [28.6] .669 [17] .858 [21.8] PANEL CUT OUT .550 [14] .07 [1.79] .921 [23.4] .236 [6] .472 [12] .0315 [.8] .394 [10] .394 [10] .248 [6.17] 1.102 [28] .532 [13.5] Time Delay Percentage of Rated Current Overload Trip Time 100% No Trip 150% Trip in 1 hr 200% 4.0 ~ 40 sec. 300% 0.9 ~ 8.0 sec. 400% 0.42 ~ 5.0 sec. 500% 0.25 ~ 3.0 sec. 600% 0.01 ~ 1.8 sec. Trip Time in Seconds Time Trip Factor 1 -10 °C x 1.70 -5 °C x 1.60 0 °C x 1.50 5 °C x 1.40 10 °C x 1.30 15 °C x 1.20 20 °C x 1.10 25 °C x 1.00 Time Trip Factor 1 30 °C x 0.90 35 °C x 0.85 40 °C x 0.80 45 °C x 0.75 50 °C x 0.70 55 °C x 0.65 60 °C x 0.60 Notes: 1. Trip Time factor is a guideline that indicates ambient temperature effect on trip times at various overload values. *Manufacturer reserves the right to change product specification without prior notice. 4 www.carlingtech.com CTB-Series - Introduction CTB CTB-Series THERMAL CIRCUIT PROTECTORS The CTB-Series is a compact, single pole, rocker actuated family of thermal circuit breakers designed to protect equipment. Utilizing simple, precision design with few moving parts, these breakers offer cost effective, extremely reliable circuit protection with high resistance against shock and vibration. Electrical ratings range from 3 to 16 amps at 125, 250VAC or 50VDC. This breaker resets with the push of a finger and features a snap in mounting style, utilizing a 16mm dia. round Double D mounting hole. Product Highlights: Ratings from 3-16A, 125, 250VAC, 50VDC .250 Tabs 60°C Max Operating Temperature 1000 AIC Interrupting Capacity 100M ohms Insulation Resistance UL, cUL, VDE, CE Applications: Household Appliances Transportation Marine Power Strips Medical Equipment Audio Visual Equipment Power Supplies Exercise Equipment ROHS Complaint www.carlingtech.com 5 CTB-Series - Ordering Scheme, Dimensional Specifications, Time Delay CTB 1 Series B 2 Bezel Color B 05 3 Rocker Color 4 RATING 03 3 amps 04 4 amps 05 5 amps 06 6 amps 07 7 amps 1 SERIES CTB 2 BEZEL COLOR 1 B Black 3 ROCKER COLOR 1 B Black B 5 Panel Thickness 4 Rating 08 09 10 12 13 8 amps 9 amps 10 amps 12 amps 13 amps 14 15 16 14 amps 15 amps 16 amps 5 PANEL THICKNESS blank fits standard thickness of .032 – .062 B fits .070 – .110 panel thickness Notes: 1. Additional colors available. Consult factory. Dimensional Specifications: in. [mm] RECOMMENDED PANEL THICKNESS: .032 - .062 [.81-1.57 Notes: All dimensions are in inches [millimeters].Tolerance ±.005 [.127] unless otherwise specified. Breaker must hold 100% of rated current and must trip at 150% and above, within the time limits shown in curve. Trip times specified at 25° ambient with no preloading. Time Delay Percentage of Rated Current Overload Trip Time 100% No Trip 135% Trip in 1 hr 200% 2.2 ~ 15 sec. 300% 0.9 ~ 3.4 sec. 400% 0.57 ~ 1.6 sec. 500% 0.38 ~ 0.94 sec. 600% 0.27 ~ 0.76 sec. Trip Time in Seconds Correction Factor 1 0 °C x 0.85 10 °C x 0.90 15 °C x 0.925 18 °C x 0.952 25 °C x 1.00 32 °C x 1.05 40 °C x 1.15 50 °C x 1.39 60 °C x 1.49 Notes: 1. To adjust the breaker rating for ambient temperature, multiply the breaker rating by the factor. ex: 5A rating x .850 = 4.25A. Select 4A rating. *Manufacturer reserves the right to change product specification without prior notice. 6 www.carlingtech.com CMB-Series - Introduction CMB CMB-Series THERMAL CIRCUIT PROTECTORS The CMB-Series is a compact, single pole, push-to-reset family of thermal circuit breakers designed to protect equipment. Utilizing simple, precision design with few moving parts, these breakers offer cost effective, extremely reliable circuit protection with high resistance against shock and vibration. Product Highlights: Ratings from 3-20A, 125, 250VAC, 32VDC 2500 VAC/1 minute 60°C Max Operating Temperature 2500A @ 32VDC Interrupting Capacity 100M ohms Insulation Resistance Voltage drop <0.25 V UL, CUL, CSA, TUV, CE UL1500/ISO8846 for ignition protection/marine Applications: Household Appliances Transportation Marine Power Strips Medical Equipment Audio Visual Equipment Power Supplies ROHS Complaint Dimensional Specifications: in. [mm] www.carlingtech.com 7 CMB-Series Pushbutton Thermal Circuit Protector CMB 10 3 1 Series 2 Rating 1 SERIES CMB 2 RATING 03 3 amps 04 4 amps 05 5 amps 06 6 amps 07 7 amps 08 8 amps 11 C 3 N 3 Voltage 4 Mounting Hole 5 Bushing Type 6 Mounting Nut B 7 Indicator Plate 8 Button A /10 9 Terminal 10 Button Marking 3 VOLTAGE 3 125-250VAC/ 32 VDC 10 12 13 14 15 16 20 4 MOUNTING HOLE 11 1 M11 12 2 M12 00 3 Snap In Style 27 9 3/8” 27 UNS 28 12 3/8” 27 UNS (double flatted) 10 amps 12 amps 13 amps 14 amps 15 amps 16 amps 20 amps 5 BUSHING PLASTIC C 4 Type C D 4 Type D E 5 Type E G 8 Type G H 6 Type H K 13 Type K METAL Type J J 8 6 MOUNTING NUT 7 N None 1 Type 1 2 Type 2 3 11 Type 3 4 Type 4 5 Type 5 14 6 Type 6 9 7 Type 7 Type 8 8 9 NOTE: Type 5 is clear hex boot. Type 8 is black hex boot (available for bushings G, J & K only); Type 3 nut includes molded in “PRESS TO RESET” marking. Embossed (ALUMINUM) 7 INDICATOR PLATE 7 N None A Embossed Legend B Silver Printing on Black Silver Printing On Black .887 [22.5] .887 [22.5] .016 [.4] Notes: All dimensions are in.[mm]. Tolerance ±.005 [.127] unless otherwise specified. 1 Used with bushing C or D only. 9 Available with G, J or K bushing only. 2 Used with H bushing only. 10 Amp rating must match button marking 3 Used with bushing E only. (ex: 20 will be marked on the button of 4 Used with M11 mounting hole only. CMB-203-27G3N-W-A/20) 5 Used with mounting hole 00 only. 11 Includes molded in “PRESS TO RESET” 6 Used with M12 mounting hole only. marking. 7 All hardware available separately. 12 Available with K bushing only. Consult factory. 13 Available with mounting hole 28 only. 8 Available with mounting hole 27 only. 14 Thickness is 3.0 mm, .118 in. .016 [.4] All indicator plates are marked “Suppl. Prot. press to reset”. 8 BUTTON B Black 9 TERMINAL A Type A B Type B C Type C D Type D E Type E R F G H J Red W White Type F Type G Type H Type J F,G,H,J TERMINALS ARE 8-32 UNC 10 BUTTON MARKING (IF BLANK, NO MARKING.)10 03 04 3 amp 4 amp 05 06 5 amp 6 amp 07 08 Button Marking Orientation: 7 amp 8 amp 10 12 10 amp 12 amp line 20 13 14 load 13 amp 14 amp 15 16 15 amp 16 amp 20 20 amp Time Delay Percentage of Rated Current Overload Trip Time 100% No Trip 150% Trip in 1 hr 200% 4.0 ~ 40 sec. 300% 0.9 ~ 8.0 sec. 400% 0.42 ~ 5.0 sec. 500% 0.25 ~ 3.0 sec. 600% 0.01 ~ 1.8 sec. Trip Time in Seconds Time Trip Factor 1 -10 °C x 1.70 -5 °C x 1.60 0 °C x 1.50 5 °C x 1.40 10 °C x 1.30 15 °C x 1.20 20 °C x 1.10 25 °C x 1.00 Time Trip Factor 1 30 °C x 0.90 35 °C x 0.85 40 °C x 0.80 45 °C x 0.75 50 °C x 0.70 55 °C x 0.65 60 °C x 0.60 Notes: 1. Trip Time factor is a guideline that indicates ambient temperature effect on trip times at various overload values. *Manufacturer reserves the right to change product specification without prior notice. 8 www.carlingtech.com CLB-Series - Introduction CLB CLB-Series THERMAL CIRCUIT PROTECTORS The CLB-Series is a compact, single pole, push-to-reset family of thermal circuit breakers designed to protect equipment. Utilizing simple, precision design with few moving parts, these breakers offer cost effective, extremely reliable circuit protection with high resistance against shock and vibration. Product Highlights: Ratings from 3-60A, 125, 250VAC, 32VDC 2500 VAC/1 minute 60°C Max Operating Temperature 2500A @ 32VDC Interrupting Capacity 100M ohms Insulation Resistance Voltage drop <0.25 V UL, CUL, CSA, TUV, CE UL1500/ISO8846 for ignition protection/marine Applications: Household Appliances Transportation Marine Power Strips Medical Equipment Audio Visual Equipment Power Supplies ROHS Complaint Dimensional Specifications: in. [mm] 3-40A Construction www.carlingtech.com 50 & 60A Construction 9 CLB-Series - Ordering Scheme, Time Delay CLB 10 3 1 Series 2 Rating 1 SERIES CLB 12 C 3 N 3 Voltage 4 Mounting Hole 5 Bushing Type 6 Mounting Nut B 7 Indicator Plate A / 10 8 Button 9 Terminal 10 Button Marking 3 VOLTAGE 3 125-250VAC/ 32 VDC 2 RATING 03 3 amps 04 4 amps 05 5 amps 06 6 amps 07 7 amps 08 8 amps 10 10 amps 12 12 amps 13 13 amps 15 15 amps 18 18 amps 20 20 amps 25 25 amps 30 30 amps 35 35 amps 40 40 amps 50 12 50 amps 60 12 60 amps 4 MOUNTING HOLE 11 1 M11 12 2 M12 00 3 Snap In Style 27 4 3/8” 27 UNS 5 BUSHING METAL Type A A 6 Type B B 6 8 Type J J PLASTIC Type C C 5 Type D D 7 8 Type E E 6 MOUNTING NUT 9 N None 1 Type 1 2 Type 2 3 Type 3 4 Type 4 5 Type 5 6 4, 14 Type 6 4 7 Type 7 8 4 Type 8 NOTE: Type 5 is clear hex boot. Type 8 is black hex boot (available for bushings E & J only); Type 3 nut includes molded in “PRESS TO RESET” marking. Embossed (ALUMINUM) 7 INDICATOR PLATE 9 N None A Embossed B Silver Printing on Black .887 [22.5] Silver Printing On Black .016 [.4] .887 [22.5] .016 [.4] All indicator plates are marked “Suppl. Prot. press to reset”. 8 BUTTON B Black R 9 TERMINAL 10,11,15 A Type A F B Type B G C Type C H D Type D J E Type E Red W Notes: All dimensions are in.[mm]. Tolerance ±.005 [.127] unless otherwise specified. 1 Used with bushing A or B only. 10 > 35 amp ratings must use solder joint to con 2 Used with bushing C only. nect wire to non-screw type terminals. 3 Used with bushing D only. 11 Terminals are .040 [1.0] thickness for rating> 35, 4 Used with bushing E & J only. & .315 [.8] thickness is for ratings < 35 amps. 5 Used with M12 mounting hole only. 12 Available only with 10-24 unc. screw terms. 6 Used with M11 mounting hole only. (select type F, G, H, J only.) UL, CUL only. 7 Used with mounting hole 00 only. 13 Amp rating must match button marking (ex: “20” 8 Used with 27 mounting hole only. will be marked on the button of the breaker) 9 All hardware available separately. 14 Thickness is 3.0 mm, .118 in. Consult factory. 15 Screw terminals are 8-32 UNC White Type F Type G Type H Type J 10 BUTTON MARKING (IF BLANK, NO MARKING.)13 Button Marking Orientation: 03 04 05 3 amp 4 amp 5 amp 06 07 08 6 amp 7 amp 8 amp 10 12 13 10 amp 12 amp 13 amp 15 18 20 line 20 load 15 amp 18 amp 20 amp 25 30 35 25 amp 30 amp 35 amp 40 50 60 40 amp 50 amp 60 amp Time Delay Percentage of Rated Current Overload Trip Time 100% No Trip 150% Trip in 1 hr 200% 4.0 ~ 40 sec. 300% 0.9 ~ 8.0 sec. 400% 0.42 ~ 5.0 sec. 500% 0.25 ~ 3.0 sec. 600% 0.01 ~ 1.8 sec. Trip Time in Seconds Time Trip Factor 1 -10 °C x 1.70 -5 °C x 1.60 0 °C x 1.50 5 °C x 1.40 10 °C x 1.30 15 °C x 1.20 20 °C x 1.10 25 °C x 1.00 Time Trip Factor 1 30 °C x 0.90 35 °C x 0.85 40 °C x 0.80 45 °C x 0.75 50 °C x 0.70 55 °C x 0.65 60 °C x 0.60 Notes: 1. Trip Time factor is a guideline that indicates ambient temperature effect on trip times at various overload values. *Manufacturer reserves the right to change product specification without prior notice. 10 www.carlingtech.com CMBA/CLBA-Series - Auto-Reset - Introduction CMBA/CLBA CMBA/CLBA-Series THERMAL CIRCUIT PROTECTORS The CMBA/CLBA-Series features automatic cycling and resetting thermal protection capabilities with the same performance as its traditional push-to-reset counterparts. Product Highlights: CMBA: 3-20A, 125, 250VAC, 32VDC CLBA: 3-40A, 125, 250VAC, 32VDC 2500 VAC/1 minute 60°C Max Operating Temperature 2500A @ 32VDC Interrupting Capacity 100M ohms Insulation Resistance Voltage drop <0.25 V UL, cUL, TUV Applications: Household Appliances Transportation Power Strips Medical Equipment Audio Visual Equipment Power Supplies ROHS Complaint Dimensional Specifications: in. [mm] CMBA Construction www.carlingtech.com CLBA Construction 11 CMBA/CLBA-Series - Auto-Reset Thermal Circuit Protector CMBA 1 Series 10 3 2 Rating NN F N N 3 Voltage 4 Mounting 5 Bushing 1 SERIES CMBA 6 Mounting Nut B 7 Indicator Plate A 8 Button Color 9 Terminal 10 Plug Marking 7 INDICATOR PLATE N N/A 2 RATING 03 3 amps 04 4 amps 05 5 amps 06 6 amps 07 7 amps 08 8 amps 10 12 13 15 18 20 8 BUTTON COLOR B Flush Black 10 amps 12 amps 13 amps 15 amps 18 amps 20 amps 9 TERMINAL A Type A 3 VOLTAGE 3 125-250VAC/ 32 VDC 4 MOUNTING NN Plug In 10 BUTTON MARKING 1 (IF BLANK, NO MARKING) Plug Marking Orientation: 5 BUSHING F None 03 04 05 06 6 MOUNTING NUT N N/A CLBA 1 Series 10 3 2 Rating 3 amp 4 amp 5 amp 6 amp 07 08 10 12 7 amp 8 amp 10 amp 12 amp NN F N N 3 Voltage 4 Mounting 5 Bushing 1 SERIES CLBA 6 Mounting Nut line 20 load 13 15 18 20 13 amp 15 amp 18 amp 20 amp B 7 Indicator Plate A 8 Button Color 9 Terminal 10 Plug Marking 7 INDICATOR PLATE N N/A 2 RATING 03 3 amps 04 4 amps 05 5 amps 06 6 amps 07 7 amps 08 8 amps 10 10 amps 12 12 amps 13 15 18 20 25 30 35 40 13 amps 15 amps 18 amps 20 amps 25 amps 30 amps 35 amps 40 amps 8 BUTTON COLOR B Flush Black 9 TERMINAL A Type A 3 VOLTAGE 3 125-250VAC/ 32 VDC 10 BUTTON MARKING 1 (IF BLANK, NO MARKING) 4 MOUNTING NN Plug In Plug Marking Orientation: 03 04 05 06 5 BUSHING F None 3 amp 4 amp 5 amp 6 amp 07 08 10 12 line 7 amp 8 amp 10 amp 12 amp 20 load 13 15 18 20 13 amp 15 amp 18 amp 20 amp 25 30 35 40 25 amp 30 amp 35 amp 40 amp 6 MOUNTING NUT N N/A Notes: 1 Amp rating must match plug marking. (ex: “20” will be marked on the plug of the breaker) No marking is standard. Time Delay Percentage of Rated Current Overload Trip Time 100% No Trip 150% Trip in 1 hr 200% 4.0 ~ 40 sec. 300% 0.9 ~ 8.0 sec. 400% 0.42 ~ 5.0 sec. 500% 0.25 ~ 3.0 sec. 600% 0.01 ~ 1.8 sec. Trip Time in Seconds Time Trip Factor 1 -10 °C x 1.70 -5 °C x 1.60 0 °C x 1.50 5 °C x 1.40 10 °C x 1.30 15 °C x 1.20 20 °C x 1.10 25 °C x 1.00 Time Trip Factor 1 30 °C x 0.90 35 °C x 0.85 40 °C x 0.80 45 °C x 0.75 50 °C x 0.70 55 °C x 0.65 60 °C x 0.60 Notes: 1. Trip Time factor is a guideline that indicates ambient temperature effect on trip times at various overload values. *Manufacturer reserves the right to change product specification without prior notice. 12 www.carlingtech.com Carling Technologies Catalogs There are several catalogs available featuring complete details on all Carling Technologies products. Below is a list of useful information such as catalogs, brochures and videos. Please visit our website at carlingtech.com or scan the QR codes below for complete details. www.carlingtech.com Watch Company Profile Video Switches & Controls Hydraulic-Magnetic SWITCHES & CONTROLS Rocker, Toggle, Pushbutton & Rotary CATALOG Circuit Protection CATALOG catalog catalog Complete line and ordering details for Switches & Control products including Rocker, Toggle, Pushbutton, and Rotary style switches. Complete line and ordering details for all hydraulic-magnetic circuit breakers. Thermal GFCI / ELCI GFCI / ELCI THERMAL Circuit Protection Circuit Protection CATALOG catalog Complete line and ordering details for all thermal circuit breakers. www.carlingtech.com CATALOG catalog Complete line and ordering details for all GFCIs/ELCIs. 13 Carling Technologies Catalogs Marine On-Off Highway MARINE ON/OFF HIGHWAY Switches, Circuit Protection & ELCI/GFCIs Switches & Controls catalog brochure catalog brochure Complete line of ELCIs, thermal and hydraulic-magnetic circuit breakers specific for marine applications. Complete line of switches, controls and custom solutions specific for on-off highway applications. Renewable Energy Military MILITARY RENEWABLE ENERGY Circuit Breakers & Disconnects COTS Switches & Circuit Breakers catalog brochure catalog brochure Complete line of circuit breakers and disconnect products specific for renewable energy applications. Complete line of COTS (Commercial-Off-The-Shelf) switches and circuit breakers specific for military applications. Telecom/Datacom Industrial Automation TELECOM/DATACOM INDUSTRIAL AUTOMATION AND CONTROLS Circuit Protection Circuit Protection & Switches catalog brochure Complete line of hydraulic-magnetic circuit breakers specific for telecom/datacom applications. 14 brochure Complete line of switches and circuit breakers specific for industrial automation & controls applications. www.carlingtech.com Reps & Contact Authorized Sales Representatives Click on the group name on the map below to find your local representative or visit www.carlingtech.com/findarep. « « Matera W. Canada Matera E. Canada MIDWEST DM Michigan TEMCO Northwest Alaska, Hawaii « NORTHERN Hanna Lind Ltd. Melody Emery Sierra Bridge Marketing Omega Limited Dy-tronix Inc. LD. Allen Norris DM Assoc East Pacent DM Assoc TSI North TSI WEST Signal Enterprises Luscombe Engineering Pinnacle Marketing Matrix DM Mexico South America Mexico « « Sunbelt Components SOUTHEAST ProRep Solutions LATIN AMERICA Americas Europe Middle East Africa Asia-Pacific Oceania About Carling Founded in 1920, Carling Technologies is a leading manufacturer of electrical and electronic switches and assemblies, circuit breakers, electronic controls, power distribution units, and multiplexed power distribution systems. With four ISO registered manufacturing facilities and technical sales offices worldwide, Carling Technologies Sales, Service and Engineering teams do much more than manufacture electrical components, they engineer powerful solutions! To learn more about Carling please visit www.carlingtech.com/company-profile. To view all of Carling’s environmental, quality, health & safety certifications please visit www.carlingtech.com/environmental-certifications www.carlingtech.com 15 Worldwide Headquarters Carling Technologies, Inc. 60 Johnson Avenue, Plainville, CT 06062-1177 Phone: 860.793.9281 Fax: 860.793.9231 Email: sales@ carlingtech.com www.carlingtech.com Northern Region Sales Office: nrsm@ carlingtech.com Southeast Region Sales Office: sersm@ carlingtech.com Midwest Region Sales Office: mrsm@ carlingtech.com West Region Sales Office: wrsm@ carlingtech.com Latin America Sales Office: larsm@ carlingtech.com Asia-Pacific Headquarters Carling Technologies, Asia-Pacific Ltd., Kowloon, Hong Kong Phone: Int + 852-2737-2277 Fax: Int + 852-2736-9332 Email: sales@ carlingtech.com.hk Shenzhen, China: shenzhen@ carlingtech.com Shanghai, China: shanghai@ carlingtech.com Pune, India: india@ carlingtech.com Kaohsiung, Taiwan: taiwan@ carlingtech.com Yokohama, Japan: japan@ carlingtech.com Europe | Middle East | Africa Headquarters Carling Technologies LTD 4 Airport Business Park, Exeter Airport, Clyst Honiton, Exeter, Devon, EX5 2UL, UK Phone: Int + 44 1392.364422 Fax: Int + 44 1392.364477 Email: ltd.sales@ carlingtech.com Germany: gmbh@ carlingtech.com France: sas@ carlingtech.com THERMAL-C_06_2016