CLB-Series - Carling Technologies

CLB-Series
THERMAL CIRCUIT PROTECTORS
Rating:
3 to 60A, 125-250VAC, 32VDC
Approvals:
UL, CUL, CSA, TUV, CE
UL1500/ISO8846 for ignition
protection/marine
Dielectric Strength:
2500 VAC/1 minute
Interrupting capacity:
2500 amps @ 32 VDC
Insulation Resistance:
100M ohms
Operating Temperature:
-10°C to 60°C
Voltage drop:
< 0.25 V
Applications:
Dimensional Specifications:
3-40A Construction 50 & 60A Construction
Household Appliances
Transportation
Marine
Power Strips
Medical Equipment
Audio Visual Equipment
Power Supplies
ROHS Compliant
.375
[9.53]
Carling Technologies, Inc.
60 Johnson Avenue, Plainville, CT 06062
Email: [email protected]
Application Support: [email protected]
Phone: 860.793.9281 Fax: 860.793.9231
www.carlingtech.com
2 | CLB-Series Pushbutton Thermal Circuit Protector
CLB
10 3
1
Series
2
Rating
12 C 3 N
3
Voltage
1 SERIES
CLB
4
Mounting
Hole
5
Bushing
Type
6
Mounting
Nut
7
Indicator
Plate
B
8
Button
A / 10
10
Button
Marking
9
Terminal
3 VOLTAGE
3
125-250VAC/ 32 VDC
2 RATING
03
3 amp
04
4 amp
05
5 amp
06
6 amp
07
7 amp
08
8 amp
10
10 amp
12
12 amp
13
13 amp
15
15 amp
18
18 amp
20
20 amp
25
25 amp
30
30 amp
35
35 amp
40
40 amp
12
50
50 amp
6012 60 amp
4 MOUNTING HOLE
111 M11
122 M12
003 Snap In Style
274 3/8” 27 UNS
5 BUSHING
METAL
A6
Type A
B6
Type B
J8
Type J
PLASTIC
C5
Type C
D7
Type D
8
E
Type E
6 MOUNTING NUT 9
N
1
2
3
4
5
64,14
74
84
None
Type 1
Type 2
Type 3
Type 4
Type 5
Type 6
Type 7
Type 8
NOTE: Type 5 is clear hex boot. Type 8 is black hex boot (available for bushings E & J only); Type 3 nut includes molded in “PRESS TO RESET” marking.
7 INDICATOR PLATE 9
N
A
B
Embossed
(ALUMINUM)
None
Embossed
Silver Printing on Black
.887
[22.5]
Silver Printing
On Black
.016
[.4]
.887
[22.5]
.016
[.4]
All indicator plates are marked
“Suppl. Prot. press to reset”.
8 BUTTON
B
R
Black
9 TERMINAL10,11,15
A
B
C
D
E
Type A
Type B Type C
Type D Type E
F
G
H
J
Red
W
White
Notes: All dimensions are in.[mm]. Tolerance ±.005 [.127] unless otherwise specified.
1 Used with bushing A or B only.
10 > 35 amp ratings must use solder joint to con
2 Used with bushing C only.
nect wire to non-screw type terminals.
3 Used with bushing D only.
11 Terminals are .040 [1.0] thickness for rating> 35, 4 Used with bushing E & J only.
& .315 [.8] thickness is for ratings < 35 amps.
5 Used with M12 mounting hole only. 12 Available only with 10-24 unc. screw terms. 6 Used with M11 mounting hole only. (select type F, G, H, J only.) UL, CUL only.
7 Used with mounting hole 00 only.
13 Amp rating must match button marking (ex: “20” 8 Used with 27 mounting hole only.
will be marked on the button of the breaker)
9 All hardware available separately. 14 Thickness is 3.0 mm, .118 in.
Consult factory.
15 Screw terminals are 8-32 UNC
Type F
Type G
Type H
Type J
10 BUTTON MARKING (IF BLANK, NO MARKING.)13 Button Marking Orientation:
03
04
05
3 amp
4 amp
5 amp
06
07
08
6 amp
7 amp
8 amp
Time Delay
10
12
13
10 amp
12 amp
13 amp
15
18
20
line
20
15 amp
18 amp
20 amp
load
25
30
35
40
50
60
25 amp
30 amp
35 amp
40 amp
50 amp
60 amp
Notes:
Breaker must hold 100% of rated current
and must trip at 150% and above, within
the time limits shown in curve. Trip
times specified at 25° ambient with no
preloading.
1 To adjust the breaker rating for ambient
temperature multiply the breaker rating
by the factor. (ex: 5 amp rating at 0°C: 5
x .67 = 3.3 amp. Select 3 amp rating.)
*Manufacturer reserves the right to change product specification without prior notice.
Email: [email protected] Application Support: [email protected]
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com
CB_CLB_03_2015