Carling Technologies, Inc.

CLB-Series
THERMAL CIRCUIT PROTECTORS
Rating:
3 to 60A, 125-250VAC, 32VDC
Approvals:
UL, CUL, CSA, TUV, CE
UL1500/ISO8846 for ignition
protection/marine
Dielectric Strength:
2500 VAC/1 minute
Interrupting capacity:
2500 amps @ 32 VDC
Insulation Resistance:
100M ohms
Operating Temperature:
-10°C to 60°C
Voltage drop:
< 0.25 V
Applications:
Household Appliances
Transportation
Marine
Power Strips
Medical Equipment
Audio Visual Equipment
Power Supplies
Dimensional Specifications:
3-40A Construction 50 & 60A Construction
ROHS Compliant
.375
[9.53]
Carling Technologies, Inc.
60 Johnson Avenue • Plainville, CT 06062-1177
Phone: (860) 793-9281 • Fax: (860) 793-9231
Email: [email protected] • www.carlingtech.com
2 | CLB-Series Pushbutton Thermal Circuit Protector
CLB — 10 3 — 12 C 3 N — B — A /10
1
Series
2
Rating
1 SERIES
CLB
3
Voltage
4
Mounting
Hole
5
Bushing
Type
6
Mounting
Nut
7
Indicator
Plate
8
Button
9
Terminal
10
Button Marking
3 VOLTAGE
3
125-250VAC/ 32 VDC
2 RATING
03
3 amp
04
4 amp
05
5 amp
06
6 amp
07
7 amp
08
8 amp
10
10 amp
12
12 amp
13
13 amp
15
15 amp
18
18 amp
20
20 amp
25
25 amp
30
30 amp
35
35 amp
40
40 amp
5013 50 amp
13
60
60 amp
4 MOUNTING HOLE
111 M11
122 M12
003 Snap In Style
279 3/8” 27 UNS
5 BUSHING
METAL
A6
Type A
B6
Type B
8
J
Type J
PLASTIC
C5
Type C
D7
Type D
E8
Type E
6 MOUNTING NUT 9
N
None
1
Type 1
2
Type 2
3
Type 3
4
Type 4
5
Type 5
12,15
6
Type 6
712 Type 7
12
8
Type 8
NOTE: Type 5 is clear hex boot. Type 8 is black hex boot (available for bushings E & J only); Type 3 nut includes molded in “PRESS TO RESET” marking.
7 INDICATOR PLATE 9
N
A
B
Notes: All dimensions are in.[mm]. Tolerance ±.005 [.127] unless otherwise specified.
1 Used with bushing A or B only.
10 > 35 amp ratings must use solder joint to con
2 Used with bushing C only.
nect wire to non-screw type terminals.
3 Used with bushing D only.
11 Terminals are .040 [1.0] thickness for rating> 35, 4 Used with bushing E & J only.
& .315 [.8] thickness is for ratings < 35 amps.
5 Used with M12 mounting hole only. 12 Available with type E or J bushing only.
6 Used with M11 mounting hole only. 13 Available only with 10-24 unc. screw terms. 7 Used with mounting hole 00 only.
(select type F, G, H, J only.) UL, CUL only.
8 Used with 27 mounting hole only.
14 Amp rating must match button marking (ex: “20” 9 All hardware available separately. will be marked on the button of the breaker)
Consult factory.
15 Thickness is 3.0 mm, .118 in.
16 Screw terminals are 8-32 UNC
None
Embossed
Silver Printing on Black
All indicator plates are marked
“circuit breaker press to reset”.
8 BUTTON
B
R
Black
9 TERMINAL10,11,16
A
B
C
D
E
Type A
Type B
Type C
Type D
Type E
F
G
H
J
Red
W
White
Type F
Type G
Type H
Type J
10 BUTTON MARKING (IF BLANK, NO MARKING.)14 Button Marking Orientation:
03
04
05
3 amp
4 amp
5 amp
06
07
08
6 amp
7 amp
8 amp
Time Delay
10
12
13
15
18
20
10 amp
12 amp
13 amp
o
o
o
o
o
o
o
o
o
20
15 amp
18 amp
20 amp
CORRECTION FACTOR1
0C
10 C
15 C
18 C
25 C
32 C
40 C
50 C
60 C
*Manufacturer reserves the right to change product specification without prior notice.
line
x .67
x .72
x .83
x .87
x 1.00
x 1.05
x 1.18
x 1.33
x 1.67
load
25
30
35
25 amp
30 amp
35 amp
OVERLOAD TRIP TIME
100%
NO TRIP
150%
TRIP IN 1 HR.
200%
5 - 35 SEC.
300%
1 - 10 SEC.
400%
.45 - 5.5 SEC.
600%
.1 - 20 SEC.
40
50
60
40 amp
50 amp
60 amp
Notes:
Breaker must hold 100% of rated current
and must trip at 150% and above, within
the time limits shown in curve. Trip
times specified at 25° ambient with no
preloading.
1 To adjust the breaker rating for ambient
temperature multiply the breaker rating
by the factor. (ex: 5 amp rating at 0°C: 5
x .67 = 3.3 amp. Select 3 amp rating.)
REV_CB_CLB_0212
60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: [email protected] • www.carlingtech.com