CLB-Series THERMAL CIRCUIT PROTECTORS Rating: 3 to 60A, 125-250VAC, 32VDC Approvals: UL, CUL, CSA, TUV, CE UL1500/ISO8846 for ignition protection/marine Dielectric Strength: 2500 VAC/1 minute Interrupting capacity: 2500 amps @ 32 VDC Insulation Resistance: 100M ohms Operating Temperature: -10°C to 60°C Voltage drop: < 0.25 V Applications: Household Appliances Transportation Marine Power Strips Medical Equipment Audio Visual Equipment Power Supplies Dimensional Specifications: 3-40A Construction 50 & 60A Construction ROHS Compliant .375 [9.53] Carling Technologies, Inc. 60 Johnson Avenue • Plainville, CT 06062-1177 Phone: (860) 793-9281 • Fax: (860) 793-9231 Email: [email protected] • www.carlingtech.com 2 | CLB-Series Pushbutton Thermal Circuit Protector CLB — 10 3 — 12 C 3 N — B — A /10 1 Series 2 Rating 1 SERIES CLB 3 Voltage 4 Mounting Hole 5 Bushing Type 6 Mounting Nut 7 Indicator Plate 8 Button 9 Terminal 10 Button Marking 3 VOLTAGE 3 125-250VAC/ 32 VDC 2 RATING 03 3 amp 04 4 amp 05 5 amp 06 6 amp 07 7 amp 08 8 amp 10 10 amp 12 12 amp 13 13 amp 15 15 amp 18 18 amp 20 20 amp 25 25 amp 30 30 amp 35 35 amp 40 40 amp 5013 50 amp 13 60 60 amp 4 MOUNTING HOLE 111 M11 122 M12 003 Snap In Style 279 3/8” 27 UNS 5 BUSHING METAL A6 Type A B6 Type B 8 J Type J PLASTIC C5 Type C D7 Type D E8 Type E 6 MOUNTING NUT 9 N None 1 Type 1 2 Type 2 3 Type 3 4 Type 4 5 Type 5 12,15 6 Type 6 712 Type 7 12 8 Type 8 NOTE: Type 5 is clear hex boot. Type 8 is black hex boot (available for bushings E & J only); Type 3 nut includes molded in “PRESS TO RESET” marking. 7 INDICATOR PLATE 9 N A B Notes: All dimensions are in.[mm]. Tolerance ±.005 [.127] unless otherwise specified. 1 Used with bushing A or B only. 10 > 35 amp ratings must use solder joint to con 2 Used with bushing C only. nect wire to non-screw type terminals. 3 Used with bushing D only. 11 Terminals are .040 [1.0] thickness for rating> 35, 4 Used with bushing E & J only. & .315 [.8] thickness is for ratings < 35 amps. 5 Used with M12 mounting hole only. 12 Available with type E or J bushing only. 6 Used with M11 mounting hole only. 13 Available only with 10-24 unc. screw terms. 7 Used with mounting hole 00 only. (select type F, G, H, J only.) UL, CUL only. 8 Used with 27 mounting hole only. 14 Amp rating must match button marking (ex: “20” 9 All hardware available separately. will be marked on the button of the breaker) Consult factory. 15 Thickness is 3.0 mm, .118 in. 16 Screw terminals are 8-32 UNC None Embossed Silver Printing on Black All indicator plates are marked “circuit breaker press to reset”. 8 BUTTON B R Black 9 TERMINAL10,11,16 A B C D E Type A Type B Type C Type D Type E F G H J Red W White Type F Type G Type H Type J 10 BUTTON MARKING (IF BLANK, NO MARKING.)14 Button Marking Orientation: 03 04 05 3 amp 4 amp 5 amp 06 07 08 6 amp 7 amp 8 amp Time Delay 10 12 13 15 18 20 10 amp 12 amp 13 amp o o o o o o o o o 20 15 amp 18 amp 20 amp CORRECTION FACTOR1 0C 10 C 15 C 18 C 25 C 32 C 40 C 50 C 60 C *Manufacturer reserves the right to change product specification without prior notice. line x .67 x .72 x .83 x .87 x 1.00 x 1.05 x 1.18 x 1.33 x 1.67 load 25 30 35 25 amp 30 amp 35 amp OVERLOAD TRIP TIME 100% NO TRIP 150% TRIP IN 1 HR. 200% 5 - 35 SEC. 300% 1 - 10 SEC. 400% .45 - 5.5 SEC. 600% .1 - 20 SEC. 40 50 60 40 amp 50 amp 60 amp Notes: Breaker must hold 100% of rated current and must trip at 150% and above, within the time limits shown in curve. Trip times specified at 25° ambient with no preloading. 1 To adjust the breaker rating for ambient temperature multiply the breaker rating by the factor. (ex: 5 amp rating at 0°C: 5 x .67 = 3.3 amp. Select 3 amp rating.) REV_CB_CLB_0212 60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231 Email: [email protected] • www.carlingtech.com