ROHM BP5039A_10

Data Sheet
100VAC Input/24VDC (200mA) Output
Non-Isolated AC/DC Converter
BP5039A
Absolute Maximum Ratings
Unit
170
200
2
105
−20 to +80
−25 to +105
V
mApk
kV
°C
°C
°C
9.1MAX.
35.0MAX.
Mark Side
Limits
Vcc
IoMAX
Vsurge
TcMAX
Topr
Tstg
19.5MAX.
Symbol
1
4±1.0
Parameter
Input voltage
Maximum output current
ESD endurance
Maximum surface temperature
Operating Temperature range
Storage temperature range
Dimensions (Unit : mm)
3
5
0 . 5 ±0 . 1
10
12
0 . 2 5 ±0 . 0 5
7.62
4.85MAX.
1 . 3 ±0 . 2
5.08
3.6MAX.
7
2.54�11=27.94
4.25MAX.
Electrical Characteristics
Max.
170
26
200
0.50
0.50
−
−
−
Conditions
DC (80 to 120VAC)
Vi=141V, Io=100mA
Vi=141V
∗1
Vi=113 to 170V, Io=100mA
Vi=141V, Io=0 to 100mA ∗2
Vi=141V, Io=100mA
Vi=141V, Io=200mA
∗2
Vi=170V, Output short, Ta=25°C
Vi=170V, Output short, Ta=80°C
Unit
V
V
mA
V
V
Vp-p
%
mA
mA
∗1 Maximum output current varies depending on ambient temperature ; please refer to derating curve.
∗2 Please refer to Load regulation, Conversion efficiency.
Application Circuit
BP5039A
Be sure to use fuse for safety.
12 10
DC motor
Ii
R1
D1
+
Vi
ZNR
−
C1
7 5 3 1
FUSE
Io
C3
L1 +
−
C2
Vo
Pin No.
1
2
3
4
5
6
7
8
9
10
11
12
Function
Output terminal Vo(24V)
Not used
Choke coil connect
Not used
Choke coil connect
Not used
COMMON
Not used
Not used
N.C.
Not used
Input terminal Vi(141VDC)
Please verify operation and characteristics in the customer's circuit before actual usage.
Ensure that the load current does not exceed the maximum rating.
Derating Curve
Derating Curve
250
Output Current Io(mA)
141
24
−
0.30
0.25
0.07
82
245
220
200
150
Operation Range
100
50
0
-30 -20 -10 0 10 20 30 40 50 60 70 80 90
Ambient Temperature Ta(°C)
Conversion Efficiency
100
90
80
70
60
50
40
30
20
10
0
0
Conversion Efficiency η(%)
Typ.
above 250V, 22 to 820µF
Ripple current 0.13Arms or above
20
15
10
5
0
C2: Output capacitor
above 25V, 100 to 470µF low impedance
ESR : 0.4Ω Max.
Ripple current 0.25Arms or above
Capacitor impedance affects the output ripple voltage.
C3: Noise reduction
capacitor
above 250V, 0.1 to 0.22µF
Use a film or ceramic capacitor
Evaluate under actual operating conditions.
L1: Power Inductor
Inductance : 1.5mH Rating current : above 0.4A
D1: Rectifier diode
In the absolute maximum ratings, the reverse surge voltage should be
400V or above the average rectifier current should be 1A or greater,
and the forward surge current should be 20A or more.
R1: Noise reduction resistor
10 to 22Ω 1/4W
Determine the ideal value through actual testing.
ZNR: Varistor
A varistor must be used to protect against lightning surges and
static electricity.
www.rohm.com
©2010 ROHM Co., Ltd. All rights reserved.
50
100 150 200 250
Output Current Io(mA)
300
Surface Temperature Increase
1/1
Temperature Rising ∆T(°C)
Use a quick-acting fuse of (1A)
200
25
0
C1: Input capacitor
50
100
150
Output Current Io(mA)
Load Regulation
(Ta=25°C, Vi=141V)
30
External Component Specifications
FUSE: FUSE
Conversion Efficiency
(Ta=31°C, Vi=141V)
Load Regulation
Output Voltage Vo(V)
Symbol Min.
Parameter
Input voltage range
113
Vi
Output voltage
22
Vo
Output current
0
Io
Line regulation
−0.50
Vr
Load regulation
−0.50
Vl
Output ripple voltage
−
Vp
Power conversion efficiency
70
η
Output current at
200
Io1
overcurrent
150
Io2
40
35
30
25
20
15
10
5
0
Surface Temperature Increase
(Ta=315°C, Vi=141V)
0
50
100
150
200
Output Current Io(mA)
250
2010.01 - Rev.A
Notice
Notes
No copying or reproduction of this document, in part or in whole, is permitted without the
consent of ROHM Co.,Ltd.
The content specified herein is subject to change for improvement without notice.
The content specified herein is for the purpose of introducing ROHM's products (hereinafter
"Products"). If you wish to use any such Product, please be sure to refer to the specifications,
which can be obtained from ROHM upon request.
Examples of application circuits, circuit constants and any other information contained herein
illustrate the standard usage and operations of the Products. The peripheral conditions must
be taken into account when designing circuits for mass production.
Great care was taken in ensuring the accuracy of the information specified in this document.
However, should you incur any damage arising from any inaccuracy or misprint of such
information, ROHM shall bear no responsibility for such damage.
The technical information specified herein is intended only to show the typical functions of and
examples of application circuits for the Products. ROHM does not grant you, explicitly or
implicitly, any license to use or exercise intellectual property or other rights held by ROHM and
other parties. ROHM shall bear no responsibility whatsoever for any dispute arising from the
use of such technical information.
The Products specified in this document are intended to be used with general-use electronic
equipment or devices (such as audio visual equipment, office-automation equipment, communication devices, electronic appliances and amusement devices).
The Products specified in this document are not designed to be radiation tolerant.
While ROHM always makes efforts to enhance the quality and reliability of its Products, a
Product may fail or malfunction for a variety of reasons.
Please be sure to implement in your equipment using the Products safety measures to guard
against the possibility of physical injury, fire or any other damage caused in the event of the
failure of any Product, such as derating, redundancy, fire control and fail-safe designs. ROHM
shall bear no responsibility whatsoever for your use of any Product outside of the prescribed
scope or not in accordance with the instruction manual.
The Products are not designed or manufactured to be used with any equipment, device or
system which requires an extremely high level of reliability the failure or malfunction of which
may result in a direct threat to human life or create a risk of human injury (such as a medical
instrument, transportation equipment, aerospace machinery, nuclear-reactor controller, fuelcontroller or other safety device). ROHM shall bear no responsibility in any way for use of any
of the Products for the above special purposes. If a Product is intended to be used for any
such special purpose, please contact a ROHM sales representative before purchasing.
If you intend to export or ship overseas any Product or technology specified herein that may
be controlled under the Foreign Exchange and the Foreign Trade Law, you will be required to
obtain a license or permit under the Law.
Thank you for your accessing to ROHM product informations.
More detail product informations and catalogs are available, please contact us.
ROHM Customer Support System
http://www.rohm.com/contact/
www.rohm.com
© 2010 ROHM Co., Ltd. All rights reserved.
R1010A