ROHM BP5034D15

Data Sheet
100VAC Input/15VDC (80mA) Output
Non-Isolated AC/DC Converter
BP5034D15
Absolute Maximum Ratings
Unit
Vi
Io
Vsurge
Topr
Tstg
195
80
2
−20 to +80
−30 to +85
V
mApk
kV
°C
°C
28.2MAX.
10.0MAX.
Mark Side
Limits
15.7MAX.
Symbol
1
4±1.0
Parameter
Input voltage
Output current
ESD endurance
Operating temperature range
Storage temperature range
Dimensions (Unit : mm)
2
3
4 5
6 7
8
10
0.25± 0.05
0 . 5 ±0 . 1
1 . 3 ±0 . 2
P = 2 . 5 4 ±0 . 2
3.25MAX
3.5MAX.
6.5MAX.
2.54�9=22.86
Typ.
141
15.0
−
0.02
0.05
0.05
70
Max.
195
16.0
80
0.15
0.15
0.15
−
Conditions
DC(80 to 138VAC)
Vi=141V, Io=80mA
Vi=141V
∗1
Vi=113 to 195V, Io=80mA
Vi=141V, Io=0 to 80mA ∗2
Vi=141V, Io=80mA
Vi=141V, Io=80mA
∗2
Unit
V
V
mA
V
V
Vp-p
%
∗1 Maximum output current varies depending on ambient temperature ; please refer to derating curve.
∗2 Please refer to Load regulation, Conversion efficiency.
Derating Curve
Derating Curve
90
80
70
60
50
40
Operation Range
30
20
10
0
-30 -20 -10 0 10 20 30 40 50 60 70 80 90
Ambient Temperature Ta(°C)
Output Current Io(mA)
Symbol Min.
Parameter
Input voltage range
113
Vi
Output voltage
14.0
Vo
Output current
0
Io
Line regulation
Vr
−
Load regulation
Vl
−
Output ripple voltage
Vp
−
Power conversion efficiency
η
60
Switching Frequency
Switching Frequency fsw(kHz)
Electrical Characteristics
Switching Frequency
(Ta=25°C, Vi=141V)
120
100
Please note that pin No.10
side is input.
10
D1
1SR139−400
Input
AC100V
50Hz/60Hz
ZNR +
220V −
R1
10Ω1/4W
C1
10µF/250V
8 7 6 5 4 3 2 1
FUSE
0.5A
Output
+15V
C2
+
0.1µF
−
C3
100µF/50V
Be sure to use fuse for safety.
Please verify operation and characteristics in the customer's circuit before actual usage.
Ensure that the load current does not exceed the maximum rating.
FUSE: Fuse
Use a quick-acting fuse of 0.5A
C1: Input smoothing
capacitor
Capacitance : 3.3 to 22µF Rated voltage : 200V or higher
Ripple current is 0.13Arms or above.
C2: Noise reduction
capacitor
Capacitance : 0.1 to 0.22µF Rated voltage : 200V or higher
Use a film or ceramic capacitor. Evaluate under actual operating
conditions.
C3: Output smoothing
capacitor
Capacitance : 100 to 470µF Rated voltage : 25V or higher,
ESR is 0.39Ω max. Ripple current is 0.1Arms or above.
Evaluate under actual conditions.
In the absolute maximum ratings, the reverse peak voltage should be
400V or higher, the average rectifying current should be 0.5A or higher,
and the peak surge current should be 20A or higher.
(Full-wave rectification can be used.)
10 to 22Ω 1/4W
Determine the ideal value through actual testing.
A varistor must be used to protect against lightning surges and static
electricity.
R1: Noise reduction
resistor
ZNR: Varistor
www.rohm.com
©2010 ROHM Co., Ltd. All rights reserved.
60
40
20
0
0
20
40
60
Output Current Io(mA)
80
80
70
60
50
40
30
20
10
0
Conversion Efficiency
(Ta=25°C, Vi=141V)
60% Min−Line
0
20
40
60
Output Current Io(mA)
80
Load Regulation
External Component Specifications
D1: Rectifier diode
80
Conversion Efficiency
1/1
Output Voltage Vo(V)
BP5034D15
Function
Output terminal Vo(15V)
N.C.
N.C.
N.C.
COMMON
COMMON
N.C.
N.C.
Not used
Input terminal Vi(141VDC)
16.0
15.8
15.6
15.4
15.2
15.0
14.8
14.6
14.4
14.2
14.0
Load Regulation
(Ta=25°C, Vi=141V)
0
20
40
60
Output Current Io(mA)
80
Surface Temperature Increase
Temperature Rising ∆T(°C)
Pin No.
1
2
3
4
5
6
7
8
9
10
Conversion Efficiency η(%)
Application Circuit
Surface Temperature Increase,
(Ta=25°C, Vi=141V)
40
30
20
10
0
0
20
40
60
Output Current Io(mA)
80
2010.01 - Rev.A
Notice
Notes
No copying or reproduction of this document, in part or in whole, is permitted without the
consent of ROHM Co.,Ltd.
The content specified herein is subject to change for improvement without notice.
The content specified herein is for the purpose of introducing ROHM's products (hereinafter
"Products"). If you wish to use any such Product, please be sure to refer to the specifications,
which can be obtained from ROHM upon request.
Examples of application circuits, circuit constants and any other information contained herein
illustrate the standard usage and operations of the Products. The peripheral conditions must
be taken into account when designing circuits for mass production.
Great care was taken in ensuring the accuracy of the information specified in this document.
However, should you incur any damage arising from any inaccuracy or misprint of such
information, ROHM shall bear no responsibility for such damage.
The technical information specified herein is intended only to show the typical functions of and
examples of application circuits for the Products. ROHM does not grant you, explicitly or
implicitly, any license to use or exercise intellectual property or other rights held by ROHM and
other parties. ROHM shall bear no responsibility whatsoever for any dispute arising from the
use of such technical information.
The Products specified in this document are intended to be used with general-use electronic
equipment or devices (such as audio visual equipment, office-automation equipment, communication devices, electronic appliances and amusement devices).
The Products specified in this document are not designed to be radiation tolerant.
While ROHM always makes efforts to enhance the quality and reliability of its Products, a
Product may fail or malfunction for a variety of reasons.
Please be sure to implement in your equipment using the Products safety measures to guard
against the possibility of physical injury, fire or any other damage caused in the event of the
failure of any Product, such as derating, redundancy, fire control and fail-safe designs. ROHM
shall bear no responsibility whatsoever for your use of any Product outside of the prescribed
scope or not in accordance with the instruction manual.
The Products are not designed or manufactured to be used with any equipment, device or
system which requires an extremely high level of reliability the failure or malfunction of which
may result in a direct threat to human life or create a risk of human injury (such as a medical
instrument, transportation equipment, aerospace machinery, nuclear-reactor controller, fuelcontroller or other safety device). ROHM shall bear no responsibility in any way for use of any
of the Products for the above special purposes. If a Product is intended to be used for any
such special purpose, please contact a ROHM sales representative before purchasing.
If you intend to export or ship overseas any Product or technology specified herein that may
be controlled under the Foreign Exchange and the Foreign Trade Law, you will be required to
obtain a license or permit under the Law.
Thank you for your accessing to ROHM product informations.
More detail product informations and catalogs are available, please contact us.
ROHM Customer Support System
http://www.rohm.com/contact/
www.rohm.com
© 2010 ROHM Co., Ltd. All rights reserved.
R1010A