Datasheet

UNISONIC TECHNOLOGIES CO., LTD
BTA10
Preliminary
TRIAC
10A TRIACS

DESCRIPTION
The UTC BTA10 is a 10A triacs which can be operated in 4
quadrants, it uses UTC’s advanced technology to provide
customers with high commutation performances, etc.
The UTC BTA10 is suitable for AC switching application and
phase control application such as fan speed and temperature
modulation control, lighting control and static switching relay, either
in through-hole or surface-mount packages.

SYMBOL

ORDERING INFORMATION
Ordering Number
Lead Free
Halogen Free
BTA10L-x-x-TF3-T
BTA10G-x-x-TF3-T

TO-220F
Packing
Tube
SENSITIVITY AND TYPE
PART NUMBER
B
C
◎: Available

Pin Assignment
1
2
3
MT1 MT2
G
Package
VOLTAGE
600V
◎
◎
800V
◎
◎
SENSITIVITY
TYPE
50mA
25mA
STANDARD
STANDARD
MARKING INFORMATION
PACKAGE
MARKING
TO-220F
www.unisonic.com.tw
Copyright © 2014 Unisonic Technologies Co., Ltd
1 of 3
QW-R401-031.d
BTA10

Preliminary
TRIACS
ABSOLUTE MAXIMUM RATINGS
PARAMETER
RMS On-State Current (Full Sine Wave) TC=95°C
Non Repetitive Surge Peak On-State
Current (Full Cycle TJ initial=25°C)
SYMBOL
IT(RMS)
F=50Hz
t=20ms
RATINGS
10
UNIT
A
100
A
ITSM
F=60Hz t=16.7ms
105
A
I2t Value for Fusing
tP=10ms
I2 t
55
A2s
Critical Rate of Rise of On-State Current:
F=120Hz TJ=125°C
dI/dt
50
A/µs
IG=2xIGT, tr≤100ns
Non Repetitive Surge Peak Off-State
tP=10ms TJ=25°C VDSM/VRSM
VDSM/VRSM+100
V
Voltage
Peak Gate Current
tP=20µs TJ=125°C
IGM
4
A
Average Gate Power Dissipation
TJ=125°C
PG(AV)
1
W
Operating Junction Temperature
TJ
-40~+125
°C
Storage Junction Temperature
TSTG
-40~+150
°C
Note: Absolute maximum ratings are those values beyond which the device could be permanently damaged.
Absolute maximum ratings are stress ratings only and functional device operation is not implied.

THERMAL RESISTANCES
PARAMETER
Junction to Ambient
Junction to Case (AC)

SYMBOL
θJA
θJC
RATINGS
60
2.4
UNIT
°C/W
°C/W
ELECTRICAL CHARACTERISTICS (TJ= 25°C, unless otherwise specified)
FOR STANDARD (4 QUADRANTS)
PARAMETER
SYMBOL
Gate Trigger Current
(Note 1)
Gate Trigger Voltage
VGT
Gate Non-Trigger Voltage
VGD
Holding Current (Note 2)
IH
IGT
Latching Current
Critical Rate of Rise of
Off-State Voltage (Note 2)
Critical Rate of Rise of
Off-State Voltage at
Commutation (Note 2)

IL
dV/dt
(dV/dt)c
I-II-III
IV
ALL
C
B
UNIT
MIN TYP MAX MIN TYP MAX
25
50
mA
50
100 mA
1.3
1.3
V
ALL
0.2
TEST CONDITIONS
VD=12V,
RL=33Ω
VD=VDRM,
RL=3.3kΩ,
TJ=125°C
IT=500mA
I-III-IV
IG=1.2IGT
II
VD=67%VDRM, Gate Open,
TJ=125°C
(dI/dt)c=4.4A/ms, TJ= 125°C
0.2
V
25
40
80
50
50
100
mA
mA
mA
200
400
V/µs
5
10
V/µs
STATIC CHARACTERISTICS
PARAMETER
Peak On-State Voltage (Note 2)
Threshold Voltage (Note 2)
Dynamic Resistance (Note 2)
SYMBOL
VT
VTO
RD
IDRM
Repetitive Peak Off-State Current
IRRM
Note: 1. Minimum IGT is guaranteed at 5% of IGT max.
2. For both polarities of MT2 referenced to MT1.
UNISONIC TECHNOLOGIES CO., LTD
www.unisonic.com.tw
TEST CONDITIONS
ITM=14A, tP=380μs TJ=25°C
TJ=125°C
TJ=125°C
TJ=25°C
VDRM=VRRM
TJ=125°C
MIN
TYP
MAX UNIT
1.55
V
0.85
V
40
mΩ
5
μA
1
mA
2 of 3
QW-R401-031.d
BTA10
Preliminary
TRIACS
UTC assumes no responsibility for equipment failures that result from using products at values that
exceed, even momentarily, rated values (such as maximum ratings, operating condition ranges, or
other parameters) listed in products specifications of any and all UTC products described or contained
herein. UTC products are not designed for use in life support appliances, devices or systems where
malfunction of these products can be reasonably expected to result in personal injury. Reproduction in
whole or in part is prohibited without the prior written consent of the copyright owner. The information
presented in this document does not form part of any quotation or contract, is believed to be accurate
and reliable and may be changed without notice.
UNISONIC TECHNOLOGIES CO., LTD
www.unisonic.com.tw
3 of 3
QW-R401-031.d