3FL Silicone Long Rod Insulators for Transmission Lines 69–500 kV Strong performance – reliable service www.siemens.com/energy/insulators Answers for energy. 3FL long rod insulators can be used either as suspension or tension insulators 3FL – a superior design to meet the highest requirements HTV silicone rubber for best pollution performances Brittle-fracture-resistant ECR-glass FRP rod One-piece HTV silicone rubber housing Junction zone Junction point: FRP rod/metal fitting/silicone (triple point) completely embedded in the silicone housing Integrated grading ring reduces the electric field inside and outside the junction zone 3FL silicone long rod insulators – performance meets durability Good reasons to use 3FL Core The new Siemens silicone long rod in sulators (type 3FL) combine the highest levels of electrical insulation and mechanical tensile strength with a compact, lightweight design. Thanks to their superior design and minimized weight, 3FL long rod insulators are especially suited for overhead compact-line applications where low tower design and short line spans are required. They are also more economical to transport and install. The core rod is a boron-free, corrosion-resistant ECR2 glass-fiber-reinforced plastic rod (FRP rod). Due to the extremely high hydrolysis and acid resistance of the FRP rod the risk of so-called brittle fracture is eliminated for 3FL insulators. Design The 3FL insulator has a one-piece HTV1 silicone rubber housing made by a highpressure injection molding process. The HTV silicone is directly molded onto the core rod by overlapping the triple junction point and part of the metal end fittings. The design ensures a total enclosure of the most sensitive part of a silicone insulator – the junction zone (metal end fitting/FRP rod/silicone housing), where the highest electrical field strength is usually concentrated. This overlapping system eliminates any possibility of moisture ingress. 2 End fittings The end fittings, made of hot-dip galvanized forged steel or ductile cast iron, are directly attached to the FRP core rod by a circumferential crimping process. Each crimping process is stringently monitored with a special control system. A complete range of end fittings according to the latest IEC and ANSI standards is available with 25, 30, 36 and 50 klbs of SML3. The 3FL is 100% exchangeable and compatible with existing insulators and line hardware of all types. The special design of the end fitting in the junction minimizes the electrical field strength and partial discharge inside the junction zone as well as on the silicone housing surface, by utilizing an integrated grading ring. This prevents corrosion of the insulating material and eliminates the risk of subsequent failure of the insulator. 3FL – HTV silicone rubber housing for best pollution performances The excellent pollution layer characteristics of the HTV silicone rubber ensure maximum reliability of the 3FL insulator, even under extreme service conditions. The high hydrophobicity of silicone rubber prevents the formation of conductive film on its surface. Even the most severe ambient conditions, such as salt fog in coastal regions or dust-laden air in industrial areas, cannot impair the intrinsic hydrophobicity of the HTV silicone rubber. Surface currents and discharges are ruled out. Neither water nor dirt on the housing surface can cause insulator flashovers – a significant factor for insulator performance. Siemens quality According to long-established Siemens tradition and experience in producing highvoltage equipment for more than a century, each production step for the 3FL – beginning with numerous incoming raw material inspections, through the assembly of the individual components, to routine tests of the finished product – is rigorously monitored and controlled. E-field distribution (%/mm) in silicone housing and in FRP core rod at 3FL insulator high-voltage end E-field distribution (%/mm) at 3FL insulator high-voltage end 3FL Housing (HTV SiR) FRP rod Silicone surface Sphericalshaped rim Connection zone End fitting Inner triple point Maximized service life No moisture ingress Minimized electrical field strength Standards and tests The one-piece housing of the 3FL insulators, i.e. weathersheds and core rod sheath (coating) is one-piece, and has only one internal interface throughout the whole insulator, namely the boundary interface between the housing and the FRP core rod. This design eliminates all internal inter faces between weathersheds and the core rod coating. These kinds of longitudinal interfaces are normally very sensitive to tangential electrical field stress, which in worst case scenarios can easily lead to erosion damage of the polymer interfaces. In particular leading to erosion of the bonding between sheds and rod sheath, and thus damage to the insulator housing. After numerous electrical calculations regarding E-field distribution along the insulator, and the connection zone on the high-voltage side in particular, the design of the 3FL insulator was optimized for maximum reduction of electrical field stress, reduced corona effect, and minimized RIV4 value. Two design keys ensure improved life expectancy by reducing electrical field stress in the triple point and on the silicone surface: All 3FL long rod insulators are designed and completely tested in compliance with the latest ANSI C29.11 and ANSI C29.12 standards for composite suspension insulators. Furthermore, the junction point in the connection zone, where all three elements (FRP rod, metal end fitting, and silicone housing) meet each other, is absolutely water- and air-tight sealed during manufacturing by using an overmolding housing system. It totally encloses this junction point with the HTV silicone rubber of the housing itself. The highest bonding strength of the one-piece HTV silicone housing to the FRP core rod combined with the overmolding design system prevent moisture ingress at the connection zone of the insulator. The spherical-shaped rim of the end fitting inside the housing homogenizes the E-field distribution on the high-voltage side of the 3FL insulator with an integrated grading ring up to 170 kV. The overmolded design system and the silicone housing shape at the connection zone reduce the electrical field strength inside the housing, at the inner triple point in particular, as well as on the silicone surface directly. This by displacing the higher electrical field strength outside the housing (i.e. to the surrounding air area), and by taking advantage of the higher silicone relative permittivity. In this way, 3FL insulators can be applied on 170 kV systems without the need for additional grading/corona rings. Each Siemens 3FL insulator that leaves the factory is routinely tested with a corresponding mechanical tensile test load of at least 50 percent of the defined SML load for at least ten seconds. 1HTV: High-temperature vulcanizing glass: Electrical- and corrosion-resistant glass 3SML: Specified mechanical load 4RIV: Radio interference voltage 2ECR Product standards ANSI C29.11 Tests for Composite – Suspension Insulation for Overhead Transmission Lines ANSI C29.12 Insulators – Composites – Suspension Type ANSI C29.1 Test Methods for Electrical Power Insulators ANSI C29.2 Insulators – Wet-process Porcelain and Toughened Glass – Suspension Type 3 End fittings Parameter Units 3FL3 3FL4 3FL5 3FL6 Electrical data Typical line voltage Dry Low frequency flashover voltage Wet Positive Critical impulse flashover voltage All types of end fittings in accordance with ANSI C29.12 and ANSI C29.2 are available with 25, 30, 36 and 50 klbs. In addition, all end fitting types according to IEC 61466-1 Negative from kV 69 69 69 69 to kV 500 500 500 500 from kV 285 285 285 285 to kV 1,006 1,006 1,006 1,006 from kV 219 219 219 219 814 to kV 814 814 814 from kV 465 465 465 465 to kV 2,820 2,820 2,820 2,820 from kV 465 465 465 465 to kV 2,795 2,795 2,795 2,795 klbs (kN) 25 (111) 30 (133) 36 (160) 50 (222) from in (mm) 33.4 (849) 33.4 (849) 35.5 (902) 35.5 (902) to in (mm) 219.7 (5,581) 219.7 (5,581) 221.8 (5,634) 221.8 (5,634) in (mm) 5/8" (16) 5/8" (16) 7/8" (22) 7/8" (22) Mechanical data Specified mechanical load, SML Section length (length increments approx. 2.05 inches [52 mm]) Core rod diameter Ø Corona ring E-field distribution (%/mm) at 3FL insulator high-voltage end equipped with corona ring Accessories Arc protection devices such as arcing horns and corona rings for reduction of electrical field stress and corona effect are carefully designed based on numerous electrical simulations regarding electrical field distribution. For system voltages above 170 kV corona rings are included in 3FL insulator application as a standard feature. Customer-specific solutions as well as other connection and cable clamps are also available on request. 4 Recommended corona rings (diameter in inch [mm]) by line voltage Line voltage kV Ground end (top end fitting) Line end (conductor end fitting) ≤ 170 kV None None 245 kV None Ø 8.3 (Ø 210) 300 kV None Ø 13 (Ø 330) 362 kV None Ø 13 (Ø 330) 420 kV Ø 8.3 (Ø 210) Ø 13 (Ø 330) 550 kV Ø 8.3 (Ø 210) Ø 16 (Ø 420) Y-Clevis acc. to ANSI C29.12 Dimensions in inch (mm) SML B 0.75 (19) 1.34 (34) 0.87 (22) 1.61 (41) B Ø A A 25 and 30 klbs 36 and 50 klbs Socket and Ball Ø A acc. to ANSI C29.2 Ø C Ø B Designation SML 52-5 52-8 52-11 Dimensions in inch (mm) A B C 25 and 30 klbs 1.3 (33) 0.67 (17) 0.75 (19) 36 klbs 1.65 (42) 0.87 (22) 0.98 (25) 50 klbs 1.65 (42) 0.87 (22) 0.98 (25) Eye acc. to ANSI C29.12 A Dimensions in inch (mm) SML 25 and 30 klbs 36 and 50 klbs B C 0.94 (24) 1.89 (48) 0.75 (19) 0.98 (25) 1.97 (50) 0.87 (22) Clevis D B Ø A acc. to ANSI C29.2 Designation SML 52-6 Dimensions in inch (mm) A B C D 25 and 30 klbs 0.63 (16) 0.71 (18) 1.26 (32) 1.81 (46) 52-10 36 klbs 0.75 (19) 0.89 (22.5) 1.02 (26) 2.20 (56) 52-12 50 klbs 0.87 (22) 1.02 (26) 1.18 (30) 2.36 (60) C A A B Ø C C Tongue Ø B acc. to ANSI C29.2 Designation SML Dimensions in inch (mm) A B C 52-6 25 and 30 klbs 0.50 (12.7) 0.69 (17.5) 1.81 (46) 52-10 36 klbs 0.75 (19) 0.81 (20.6) 1.81 (46) 52-12 50 klbs 0.87 (22) 0.94 (23.8) 2.05 (52) 5 Suspension insulators 3FL3 Specified mechanical load SML: 25 klbs (111 kN) Routine test load RTL: 13 klbs (56 kN) Rod diameter Ø: 5/8" (16 mm) 3FL silicone long rod insulators for suspension and tension applications are available in lengths appropriate for 60 kV through 550 kV. Length increments are 2.05 inches or 52 mm. Just a few selected insulator lengths are listed in the following catalog table. Custom lengths available on request. Catalog number Typical line voltage kV 3FLx- <72.5 72.5 72.5 72.5 72.5 123 123 123 145 145 170 170 170 170 170 170 170 170 170 245 245 245 245 245 245 300 300 300 300 300 300 362 362 362 362 362 362 362 362 362 420 420 420 420 420 550 550 550 Nominal polymer length -3X1X210-2X3X41 3FL3-044-3YA10-2XX1 3FL3-047-3YA10-2XX1 3FL3-055-3YA10-2XX1 3FL3-058-3YA10-2XX1 3FL3-063-3YA10-2XX1 3FL3-066-3YA10-2XX1 3FL3-072-3YA10-2XX1 3FL3-074-3YA10-2XX1 3FL3-080-3YA10-2XX1 3FL3-085-3YA10-2XX1 3FL3-088-3YA10-2XX1 3FL3-091-3YA10-2XX1 3FL3-097-3YA10-2XX1 3FL3-104-3YA10-2XX1 3FL3-107-3YA10-2XX1 3FL3-110-3YA10-2XX1 3FL3-113-3YA10-2XX1 3FL3-116-3YA10-2XX1 3FL3-119-3YA10-2XX1 3FL3-122-3YA10-2XR1 3FL3-125-3YA10-2XR1 3FL3-128-3YA10-2XR1 3FL3-131-3YA10-2XR1 3FL3-137-3YA10-2XR1 3FL3-143-3YA10-2XR1 3FL3-149-3YA10-2XR1 3FL3-155-3YA10-2XR1 3FL3-161-3YA10-2XR1 3FL3-168-3YA10-2XR1 3FL3-170-3YA10-2XR1 3FL3-174-3YA10-2XR1 3FL3-177-3YA10-2XR1 3FL3-180-3YA10-2XR1 3FL3-183-3YA10-2XR1 3FL3-184-3YA10-2XR1 3FL3-186-3YA10-2XR1 3FL3-188-3YA10-2XR1 3FL3-191-3YA10-2XR1 3FL3-193-3YA10-2XR1 3FL3-194-3YA10-2XR1 3FL3-196-3YA10-2RR1 3FL3-200-3YA10-2RR1 3FL3-203-3YA10-2RR1 3FL3-205-3YA10-2RR1 3FL3-215-3YA10-2RR1 3FL3-228-3YA10-2RR1 3FL3-242-3YA10-2RR1 3FL3-257-3YA10-2RR1 Section length* Arcing distance Leakage distance Low frequency flashover dry wet Critical impulse flashover Corona ring installation positive negative top / bottom Approx. net weight inches mm inches mm inches mm inches mm kV kV kV kV inches / inches lbs kg 24.2 26.2 32.3 34.4 38.5 40.5 44.6 46.7 50.8 54.9 56.9 59.0 63.1 67.1 69.2 71.2 73.3 75.3 77.4 79.4 81.5 83.5 85.6 89.7 93.8 97.9 101.9 106.0 110.1 112.2 114.2 116.3 118.3 120.4 122.4 124.5 126.5 130.6 132.7 134.7 136.8 140.8 144.9 147.0 159.3 175.6 192.0 210.5 614 666 822 874 978 1,030 1,134 1,186 1,290 1,394 1,446 1,498 1,602 1,706 1,758 1,810 1,862 1,914 1,966 2,018 2,070 2,122 2,174 2,278 2,382 2,486 2,590 2,694 2,798 2,850 2,902 2,954 3,006 3,058 3,110 3,162 3,214 3,318 3,370 3,422 3,474 3,578 3,682 3,734 4,046 4,462 4,878 5,346 33.4 35.5 41.6 43.6 47.7 49.8 53.9 55.9 60.0 64.1 66.2 68.2 72.3 76.4 78.4 80.5 82.5 84.6 86.6 88.7 90.7 92.8 94.8 98.9 103.0 107.1 111.2 115.3 119.4 121.4 123.5 125.5 127.6 129.6 131.7 133.7 135.8 139.9 141.9 144.0 146.0 150.1 154.2 156.2 168.5 184.9 201.3 219.7 849 901 1,057 1,109 1,213 1,265 1,369 1,421 1,525 1,629 1,681 1,733 1,837 1,941 1,993 2,045 2,097 2,149 2,201 2,253 2,305 2,357 2,409 2,513 2,617 2,721 2,825 2,929 3,033 3,085 3,137 3,189 3,241 3,293 3,345 3,397 3,449 3,553 3,605 3,657 3,709 3,813 3,917 3,969 4,281 4,697 5,113 5,581 25.3 27.4 33.5 35.6 39.7 41.7 45.8 47.9 52.0 56.1 58.1 60.1 64.2 68.3 70.4 72.4 74.5 76.5 78.6 78.9 80.9 82.9 85.0 89.1 93.2 96.7 100.8 104.9 109.0 111.0 113.1 115.1 117.2 119.2 121.3 123.3 125.3 129.4 131.5 133.5 133.8 137.9 142.0 144.0 156.3 171.9 188.3 206.7 644 696 852 904 1,008 1,060 1,164 1,216 1,320 1,424 1,476 1,528 1,632 1,736 1,788 1,840 1,892 1,944 1,996 2,003 2,055 2,107 2,159 2,263 2,367 2,456 2,560 2,664 2,768 2,820 2,872 2,924 2,976 3,028 3,080 3,132 3,184 3,288 3,340 3,392 3,399 3,503 3,607 3,659 3,971 4,367 4,783 5,251 67.2 73.6 92.8 99.2 112.0 118.4 131.2 137.6 150.4 163.2 169.6 176.0 188.8 201.6 208.0 214.4 220.8 227.2 233.6 240.0 246.4 252.8 259.2 272.0 284.8 297.6 310.4 323.2 336.0 342.4 348.8 355.2 361.6 368.0 374.4 380.8 387.2 400.1 406.5 412.9 419.3 432.1 444.9 451.3 489.7 540.9 592.1 649.7 1,706 1,868 2,356 2,519 2,844 3,007 3,332 3,494 3,820 4,145 4,307 4,470 4,795 5,121 5,283 5,446 5,608 5,771 5,934 6,096 6,259 6,421 6,584 6,909 7,234 7,560 7,885 8,210 8,535 8,698 8,861 9,023 9,186 9,348 9,511 9,674 9,836 10,161 10,324 10,487 10,649 10,974 11,300 11,462 12,438 13,739 15,040 16,503 285 302 351 368 400 417 450 466 499 532 547 563 594 624 640 655 670 686 701 717 732 743 755 777 800 822 845 867 890 901 912 923 935 946 948 950 952 957 959 961 963 967 972 974 987 1,004 1,006 1,006 219 238 294 313 351 370 407 426 463 501 514 527 552 578 590 603 616 629 641 654 667 671 675 683 691 699 706 714 722 726 730 734 738 742 745 747 750 755 757 760 763 768 773 775 791 811 814 814 465 493 578 606 662 691 747 775 831 888 920 952 1,016 1,081 1,113 1,145 1,177 1,209 1,241 1,273 1,306 1,336 1,367 1,428 1,490 1,551 1,612 1,673 1,735 1,765 1,796 1,827 1,857 1,888 1,921 1,955 1,988 2,055 2,088 2,121 2,155 2,221 2,288 2,321 2,521 2,787 2,820 2,820 465 493 580 608 666 695 752 781 838 896 926 956 1,017 1,077 1,108 1,138 1,168 1,198 1,229 1,259 1,289 1,322 1,355 1,420 1,485 1,551 1,616 1,681 1,747 1,779 1,812 1,845 1,877 1,910 1,942 1,973 2,005 2,068 2,100 2,131 2,163 2,226 2,289 2,321 2,511 2,764 2,795 2,795 x/x x/x x/x x/x x/x x/x x/x x/x x/x x/x x/x x/x x/x x/x x/x x/x x/x x/x x/x x / Ø 8.3 x / Ø 8.3 x / Ø 8.3 x / Ø 8.3 x / Ø 8.3 x / Ø 8.3 x / Ø 13 x / Ø 13 x / Ø 13 x / Ø 13 x / Ø 13 x / Ø 13 x / Ø 13 x / Ø 13 x / Ø 13 x / Ø 13 x / Ø 13 x / Ø 13 x / Ø 13 x / Ø 13 x / Ø 13 Ø 8.3 / Ø 13 Ø 8.3 / Ø 13 Ø 8.3 / Ø 13 Ø 8.3 / Ø 13 Ø 8.3 / Ø 13 Ø 8.3 / Ø 16 Ø 8.3 / Ø 16 Ø 8.3 / Ø 16 6.4 6.6 7.2 7.3 7.7 7.9 8.3 8.4 8.8 9.2 9.4 9.5 9.9 10.3 10.5 10.6 10.8 11.0 11.2 13.5 13.7 13.9 14.1 14.4 14.8 20.0 20.4 20.8 21.1 21.3 21.5 21.7 21.9 22.1 22.2 22.4 22.6 23.0 23.2 23.3 25.7 26.0 26.4 26.6 27.7 33.2 34.6 36.3 2.9 3.0 3.3 3.3 3.5 3.6 3.8 3.8 4.0 4.2 4.3 4.3 4.5 4.7 4.8 4.8 4.9 5.0 5.1 6.1 6.2 6.3 6.4 6.6 6.7 9.1 9.3 9.4 9.6 9.7 9.8 9.8 9.9 10.0 10.1 10.2 10.3 10.4 10.5 10.6 11.6 11.8 12.0 12.1 12.6 15.1 15.7 16.5 *R eference section length for insulator configuration with Y-clevis (Y) and Ball (A) end fittings. To obtain the section length of other end fitting configurations please use the section length adjustment table. X1: Upper end fitting (earth side) X2: Bottom end fitting (high-voltage side) X3: Upper corona ring (earth side) X4: Bottom corona ring (high-voltage side) Section length adjustment table** Base end fittings: Y-clevis / Ball (catalog code: YA) Top end fitting (tower connection) Bottom end fitting (conductor connection) Catalog number End fittings Length change inches mm SML Type Standard Catalog number Length inches mm Y-clevis Eye YE -0.8 -20 25 klbs Ball 52-5 ANSI C29-2 A 4.3 Eye Ball EA 0.0 -1 25 klbs Socket 52-5 ANSI C29-2 Q 3.9 99 Eye Eye EE -0.8 -21 25 klbs Clevis 52-6 ANSI C29-2 D 4.7 119 Socket Ball QA 1.1 28 25 klbs Tongue 52-6 ANSI C29-2 V 4.3 110 Clevis Ball DA 0.3 8 25 klbs Y-clevis ANSI C29-12 Y 5 127 Clevis Eye DE -0.5 -12 25 klbs Eye ANSI C29-12 E 5 128 Clevis Clevis DD -0.1 -3 Clevis Tongue DV 0.2 6 Tongue Tongue VV 0.6 15 ** T o determine the section length for an insulator with a different end fitting combination, please add or subtract the displayed length change in the table above. For configurations not shown, use the catalog number key or contact your Siemens representative. 6 108 Suspension insulators 3FL4 Specified mechanical load SML: 30 klbs (133 kN) Routine test load RTL: 15 klbs (66.5 kN) Rod diameter Ø: 5/8" (16 mm) 3FL silicone long rod insulators for suspension and tension applications are available in lengths appropriate for 60 kV through 550 kV. Length increments are 2.05 inches or 52 mm. Just a few selected insulator lengths are listed in the following catalog table. Custom lengths available on request. Typical line voltage Catalog number kV 3FLx- <72.5 72.5 72.5 72.5 72.5 123 123 123 145 145 170 170 170 170 170 170 170 170 170 245 245 245 245 245 245 300 300 300 300 300 300 362 362 362 362 362 362 362 362 362 420 420 420 420 420 550 550 550 Nominal polymer length -3X1X210-2X3X41 3FL4-044-3YA10-2XX1 3FL4-047-3YA10-2XX1 3FL4-055-3YA10-2XX1 3FL4-058-3YA10-2XX1 3FL4-063-3YA10-2XX1 3FL4-066-3YA10-2XX1 3FL4-072-3YA10-2XX1 3FL4-074-3YA10-2XX1 3FL4-080-3YA10-2XX1 3FL4-085-3YA10-2XX1 3FL4-088-3YA10-2XX1 3FL4-091-3YA10-2XX1 3FL4-097-3YA10-2XX1 3FL4-104-3YA10-2XX1 3FL4-107-3YA10-2XX1 3FL4-110-3YA10-2XX1 3FL4-113-3YA10-2XX1 3FL4-116-3YA10-2XX1 3FL4-119-3YA10-2XX1 3FL4-122-3YA10-2XR1 3FL4-125-3YA10-2XR1 3FL4-128-3YA10-2XR1 3FL4-131-3YA10-2XR1 3FL4-137-3YA10-2XR1 3FL4-143-3YA10-2XR1 3FL4-149-3YA10-2XR1 3FL4-155-3YA10-2XR1 3FL4-161-3YA10-2XR1 3FL4-168-3YA10-2XR1 3FL4-170-3YA10-2XR1 3FL4-174-3YA10-2XR1 3FL4-177-3YA10-2XR1 3FL4-180-3YA10-2XR1 3FL4-183-3YA10-2XR1 3FL4-184-3YA10-2XR1 3FL4-186-3YA10-2XR1 3FL4-188-3YA10-2XR1 3FL4-191-3YA10-2XR1 3FL4-193-3YA10-2XR1 3FL4-194-3YA10-2XR1 3FL4-196-3YA10-2RR1 3FL4-200-3YA10-2RR1 3FL4-203-3YA10-2RR1 3FL4-205-3YA10-2RR1 3FL4-215-3YA10-2RR1 3FL4-228-3YA10-2RR1 3FL4-242-3YA10-2RR1 3FL4-257-3YA10-2RR1 Section length* Arcing distance Leakage distance Low frequency flashover dry wet Critical impulse flashover Corona ring installation positive negative top / bottom Approx. net weight inches mm inches mm inches mm inches mm kV kV kV kV inches / inches lbs kg 24.2 26.2 32.3 34.4 38.5 40.5 44.6 46.7 50.8 54.9 56.9 59.0 63.1 67.1 69.2 71.2 73.3 75.3 77.4 79.4 81.5 83.5 85.6 89.7 93.8 97.9 101.9 106.0 110.1 112.2 114.2 116.3 118.3 120.4 122.4 124.5 126.5 130.6 132.7 134.7 136.8 140.8 144.9 147.0 159.3 175.6 192.0 210.5 614 666 822 874 978 1,030 1,134 1,186 1,290 1,394 1,446 1,498 1,602 1,706 1,758 1,810 1,862 1,914 1,966 2,018 2,070 2,122 2,174 2,278 2,382 2,486 2,590 2,694 2,798 2,850 2,902 2,954 3,006 3,058 3,110 3,162 3,214 3,318 3,370 3,422 3,474 3,578 3,682 3,734 4,046 4,462 4,878 5,346 33.4 35.5 41.6 43.6 47.7 49.8 53.9 55.9 60.0 64.1 66.2 68.2 72.3 76.4 78.4 80.5 82.5 84.6 86.6 88.7 90.7 92.8 94.8 98.9 103.0 107.1 111.2 115.3 119.4 121.4 123.5 125.5 127.6 129.6 131.7 133.7 135.8 139.9 141.9 144.0 146.0 150.1 154.2 156.2 168.5 184.9 201.3 219.7 849 901 1,057 1,109 1,213 1,265 1,369 1,421 1,525 1,629 1,681 1,733 1,837 1,941 1,993 2,045 2,097 2,149 2,201 2,253 2,305 2,357 2,409 2,513 2,617 2,721 2,825 2,929 3,033 3,085 3,137 3,189 3,241 3,293 3,345 3,397 3,449 3,553 3,605 3,657 3,709 3,813 3,917 3,969 4,281 4,697 5,113 5,581 25.3 27.4 33.5 35.6 39.7 41.7 45.8 47.9 52.0 56.1 58.1 60.1 64.2 68.3 70.4 72.4 74.5 76.5 78.6 78.9 80.9 82.9 85.0 89.1 93.2 96.7 100.8 104.9 109.0 111.0 113.1 115.1 117.2 119.2 121.3 123.3 125.3 129.4 131.5 133.5 133.8 137.9 142.0 144.0 156.3 171.9 188.3 206.7 644 696 852 904 1,008 1,060 1,164 1,216 1,320 1,424 1,476 1,528 1,632 1,736 1,788 1,840 1,892 1,944 1,996 2,003 2,055 2,107 2,159 2,263 2,367 2,456 2,560 2,664 2,768 2,820 2,872 2,924 2,976 3,028 3,080 3,132 3,184 3,288 3,340 3,392 3,399 3,503 3,607 3,659 3,971 4,367 4,783 5,251 67.2 73.6 92.8 99.2 112.0 118.4 131.2 137.6 150.4 163.2 169.6 176.0 188.8 201.6 208.0 214.4 220.8 227.2 233.6 240.0 246.4 252.8 259.2 272.0 284.8 297.6 310.4 323.2 336.0 342.4 348.8 355.2 361.6 368.0 374.4 380.8 387.2 400.1 406.5 412.9 419.3 432.1 444.9 451.3 489.7 540.9 592.1 649.7 1,706 1,868 2,356 2,519 2,844 3,007 3,332 3,494 3,820 4,145 4,307 4,470 4,795 5,121 5,283 5,446 5,608 5,771 5,934 6,096 6,259 6,421 6,584 6,909 7,234 7,560 7,885 8,210 8,535 8,698 8,861 9,023 9,186 9,348 9,511 9,674 9,836 10,161 10,324 10,487 10,649 10,974 11,300 11,462 12,438 13,739 15,040 16,503 285 302 351 368 400 417 450 466 499 532 547 563 594 624 640 655 670 686 701 717 732 743 755 777 800 822 845 867 890 901 912 923 935 946 948 950 952 957 959 961 963 967 972 974 987 1,004 1,006 1,006 219 238 294 313 351 370 407 426 463 501 514 527 552 578 590 603 616 629 641 654 667 671 675 683 691 699 706 714 722 726 730 734 738 742 745 747 750 755 757 760 763 768 773 775 791 811 814 814 465 493 578 606 662 691 747 775 831 888 920 952 1,016 1,081 1,113 1,145 1,177 1,209 1,241 1,273 1,306 1,336 1,367 1,428 1,490 1,551 1,612 1,673 1,735 1,765 1,796 1,827 1,857 1,888 1,921 1,955 1,988 2,055 2,088 2,121 2,155 2,221 2,288 2,321 2,521 2,787 2,820 2,820 465 493 580 608 666 695 752 781 838 896 926 956 1,017 1,077 1,108 1,138 1,168 1,198 1,229 1,259 1,289 1,322 1,355 1,420 1,485 1,551 1,616 1,681 1,747 1,779 1,812 1,845 1,877 1,910 1,942 1,973 2,005 2,068 2,100 2,131 2,163 2,226 2,289 2,321 2,511 2,764 2,795 2,795 x/x x/x x/x x/x x/x x/x x/x x/x x/x x/x x/x x/x x/x x/x x/x x/x x/x x/x x/x x / Ø 8.3 x / Ø 8.3 x / Ø 8.3 x / Ø 8.3 x / Ø 8.3 x / Ø 8.3 x / Ø 13 x / Ø 13 x / Ø 13 x / Ø 13 x / Ø 13 x / Ø 13 x / Ø 13 x / Ø 13 x / Ø 13 x / Ø 13 x / Ø 13 x / Ø 13 x / Ø 13 x / Ø 13 x / Ø 13 Ø 8.3 / Ø 13 Ø 8.3 / Ø 13 Ø 8.3 / Ø 13 Ø 8.3 / Ø 13 Ø 8.3 / Ø 13 Ø 8.3 / Ø 16 Ø 8.3 / Ø 16 Ø 8.3 / Ø 16 6.4 6.6 7.2 7.3 7.7 7.9 8.3 8.4 8.8 9.2 9.4 9.5 9.9 10.3 10.5 10.6 10.8 11.0 11.2 13.5 13.7 13.9 14.1 14.4 14.8 20.0 20.4 20.8 21.1 21.3 21.5 21.7 21.9 22.1 22.2 22.4 22.6 23.0 23.2 23.3 25.7 26.0 26.4 26.6 27.7 33.2 34.6 36.3 2.9 3.0 3.3 3.3 3.5 3.6 3.8 3.8 4.0 4.2 4.3 4.3 4.5 4.7 4.8 4.8 4.9 5.0 5.1 6.1 6.2 6.3 6.4 6.6 6.7 9.1 9.3 9.4 9.6 9.7 9.8 9.8 9.9 10.0 10.1 10.2 10.3 10.4 10.5 10.6 11.6 11.8 12.0 12.1 12.6 15.1 15.7 16.5 *R eference section length for insulator configuration with Y-clevis (Y) and Ball (A) end fittings. To obtain the section length of other end fitting configurations please use the section length adjustment table. X1: Upper end fitting (earth side) X2: Bottom end fitting (high-voltage side) X3: Upper corona ring (earth side) X4: Bottom corona ring (high-voltage side) Section length adjustment table** Base end fittings: Y-clevis / Ball (catalog code: YA) Top end fitting (tower connection) Bottom end fitting (conductor connection) Catalog number End fittings Length change inches mm SML Type Standard Catalog number Length inches mm Y-clevis Eye YE -0.8 -20 25 klbs Ball 52-5 ANSI C29-2 A 4.3 Eye Ball EA 0.0 -1 25 klbs Socket 52-5 ANSI C29-2 Q 3.9 99 Eye Eye EE -0.8 -21 25 klbs Clevis 52-6 ANSI C29-2 D 4.7 119 Socket Ball QA 1.1 28 25 klbs Tongue 52-6 ANSI C29-2 V 4.3 110 Clevis Ball DA 0.3 8 25 klbs Y-clevis ANSI C29-12 Y 5 127 Clevis Eye DE -0.5 -12 25 klbs Eye ANSI C29-12 E 5 128 Clevis Clevis DD -0.1 -3 Clevis Tongue DV 0.2 6 Tongue Tongue VV 0.6 15 108 ** T o determine the section length for an insulator with a different end fitting combination, please add or subtract the displayed length change in the table above. For configurations not shown, use the catalog number key or contact your Siemens representative. 7 Suspension insulators 3FL5 Specified mechanical load SML: 36 klbs (160 kN) Routine test load RTL: 18 klbs (80 kN) Rod diameter Ø: 7/8" (22 mm) 3FL silicone long rod insulators for suspension and tension applications are available in lengths appropriate for 60 kV through 550 kV. Length increments are 2.05 inches or 52 mm. Just a few selected insulator lengths are listed in the following catalog table. Custom lengths available on request. Catalog number Typical line voltage kV 3FLx- <72.5 72.5 72.5 72.5 72.5 72.5 123 123 123 145 145 145 170 170 170 170 170 170 170 170 245 245 245 245 245 300 300 300 300 300 300 300 300 362 362 362 362 362 362 420 420 420 420 420 420 550 550 550 Nominal polymer length -3X1X220-2X3X41 3FL5-044-3YA20-2XX1 3FL5-047-3YA20-2XX1 3FL5-050-3YA20-2XX1 3FL5-055-3YA20-2XX1 3FL5-058-3YA20-2XX1 3FL5-063-3YA20-2XX1 3FL5-066-3YA20-2XX1 3FL5-072-3YA20-2XX1 3FL5-074-3YA20-2XX1 3FL5-077-3YA20-2XX1 3FL5-080-3YA20-2XX1 3FL5-085-3YA20-2XX1 3FL5-091-3YA20-2XX1 3FL5-097-3YA20-2XX1 3FL5-100-3YA20-2XX1 3FL5-104-3YA20-2XX1 3FL5-107-3YA20-2XX1 3FL5-110-3YA20-2XX1 3FL5-113-3YA20-2XX1 3FL5-119-3YA20-2XX1 3FL5-122-3YA20-2XR1 3FL5-125-3YA20-2XR1 3FL5-131-3YA20-2XR1 3FL5-137-3YA20-2XR1 3FL5-143-3YA20-2XR1 3FL5-149-3YA20-2XR1 3FL5-155-3YA20-2XR1 3FL5-158-3YA20-2XR1 3FL5-161-3YA20-2XR1 3FL5-164-3YA20-2XR1 3FL5-168-3YA20-2XR1 3FL5-170-3YA20-2XR1 3FL5-174-3YA20-2XR1 3FL5-177-3YA20-2XR1 3FL5-180-3YA20-2XR1 3FL5-183-3YA20-2XR1 3FL5-186-3YA20-2XR1 3FL5-189-3YA20-2XR1 3FL5-193-3YA20-2XR1 3FL5-196-3YA20-2XR1 3FL5-200-3YA20-2RR1 3FL5-201-3YA20-2RR1 3FL5-203-3YA20-2RR1 3FL5-205-3YA20-2RR1 3FL5-213-3YA20-2RR1 3FL5-233-3YA20-2RR1 3FL5-244-3YA20-2RR1 3FL5-257-3YA20-2RR1 Section length Arcing distance Leakage distance Low frequency flashover dry wet Critical impulse flashover Corona ring installation positive negative top / bottom Approx. net weight inches mm inches mm inches mm inches mm kV kV kV kV inches / inches lbs kg 24.2 26.2 28.2 32.3 34.4 38.5 40.5 44.6 46.7 48.7 50.8 54.9 59.0 63.1 65.1 67.1 69.2 71.2 73.3 77.4 79.4 81.5 85.6 89.7 93.8 97.9 101.9 104.0 106.0 108.1 110.1 112.2 114.2 116.3 118.3 120.4 124.5 128.6 132.7 136.8 140.8 142.9 144.9 147.0 157.2 181.8 194.1 210.5 614 666 718 822 874 978 1,030 1,134 1,186 1,238 1,290 1,394 1,498 1,602 1,654 1,706 1,758 1,810 1,862 1,966 2,018 2,070 2,174 2,278 2,382 2,486 2,590 2,642 2,694 2,746 2,798 2,850 2,902 2,954 3,006 3,058 3,162 3,266 3,370 3,474 3,578 3,630 3,682 3,734 3,994 4,618 4,930 5,346 35.5 37.5 39.6 43.7 45.7 49.8 51.9 56.0 58.0 60.1 62.1 66.2 70.3 74.4 76.4 78.5 80.5 82.6 84.6 88.7 90.8 92.8 96.9 101.0 105.1 109.2 113.3 115.3 117.4 119.4 121.5 123.5 125.6 127.6 129.7 131.7 135.8 139.9 144.0 148.1 152.2 154.2 156.3 158.3 168.6 193.1 205.4 221.8 902 954 1,006 1,110 1,162 1,266 1,318 1,422 1,474 1,526 1,578 1,682 1,786 1,890 1,942 1,994 2,046 2,098 2,150 2,254 2,306 2,358 2,462 2,566 2,670 2,774 2,878 2,930 2,982 3,034 3,086 3,138 3,190 3,242 3,294 3,346 3,450 3,554 3,658 3,762 3,866 3,918 3,970 4,022 4,282 4,906 5,218 5,634 25.3 27.3 29.4 33.5 35.5 39.6 41.7 45.8 47.8 49.9 51.9 56.0 60.1 64.2 66.2 68.3 70.3 72.4 74.4 78.5 78.8 80.8 84.9 89.0 93.1 96.6 100.7 102.8 104.8 106.9 108.9 111.0 113.0 115.1 117.1 119.2 123.2 127.3 131.4 133.8 137.9 139.9 141.9 144.0 154.2 178.0 190.3 206.7 643 695 747 851 903 1,007 1,059 1,163 1,215 1,267 1,319 1,423 1,527 1,631 1,683 1,735 1,787 1,839 1,891 1,995 2,002 2,054 2,158 2,262 2,366 2,455 2,559 2,611 2,663 2,715 2,767 2,819 2,871 2,923 2,975 3,027 3,131 3,235 3,339 3,398 3,502 3,554 3,606 3,658 3,918 4,522 4,834 5,250 67.0 73.4 79.8 92.6 99.0 111.8 118.2 131.0 137.4 143.8 150.2 163.0 175.8 188.6 195.0 201.4 207.9 214.3 220.7 233.5 239.9 246.3 259.1 271.9 284.7 297.5 310.3 316.7 323.1 329.5 335.9 342.3 348.7 355.1 361.5 367.9 380.7 393.5 406.3 419.1 431.9 438.3 444.7 451.1 483.1 560.0 598.4 649.6 1,702 1,865 2,027 2,353 2,515 2,840 3,003 3,328 3,491 3,653 3,816 4,141 4,466 4,792 4,954 5,117 5,279 5,442 5,605 5,930 6,093 6,255 6,580 6,906 7,231 7,556 7,881 8,044 8,206 8,369 8,532 8,694 8,857 9,019 9,182 9,345 9,670 9,995 10,320 10,646 10,971 11,133 11,296 11,459 12,272 14,223 15,199 16,499 285 302 318 351 368 400 417 450 466 483 499 532 563 594 609 624 640 655 670 701 717 732 755 777 800 822 845 856 867 878 890 901 912 923 935 946 950 955 959 963 967 970 972 974 985 1,006 1,006 1,006 219 238 257 294 313 351 370 407 426 445 463 501 527 552 565 578 590 603 616 641 654 667 675 683 691 699 706 710 714 718 722 726 730 734 738 742 747 752 757 763 768 770 773 775 788 814 814 814 465 493 521 578 606 662 691 747 775 803 831 888 952 1,016 1,048 1,081 1,113 1,145 1,177 1,241 1,273 1,306 1,367 1,428 1,490 1,551 1,612 1,643 1,673 1,704 1,735 1,765 1,796 1,827 1,857 1,888 1,955 2,021 2,088 2,155 2,221 2,254 2,288 2,321 2,487 2,820 2,820 2,820 465 493 522 580 608 666 695 752 781 810 838 896 956 1,017 1,047 1,077 1,108 1,138 1,168 1,229 1,259 1,289 1,355 1,420 1,485 1,551 1,616 1,649 1,681 1,714 1,747 1,779 1,812 1,845 1,877 1,910 1,973 2,036 2,100 2,163 2,226 2,258 2,289 2,321 2,479 2,795 2,795 2,795 x/x x/x x/x x/x x/x x/x x/x x/x x/x x/x x/x x/x x/x x/x x/x x/x x/x x/x x/x x/x x / Ø 8.3 x / Ø 8.3 x / Ø 8.3 x / Ø 8.3 x / Ø 8.3 x / Ø 13 x / Ø 13 x / Ø 13 x / Ø 13 x / Ø 13 x / Ø 13 x / Ø 13 x / Ø 13 x / Ø 13 x / Ø 13 x / Ø 13 x / Ø 13 x / Ø 13 x / Ø 13 Ø 8.3 / Ø 13 Ø 8.3 / Ø 13 Ø 8.3 / Ø 13 Ø 8.3 / Ø 13 Ø 8.3 / Ø 13 Ø 8.3 / Ø 13 Ø 8.3 / Ø 16 Ø 8.3 / Ø 16 Ø 8.3 / Ø 16 10.9 11.1 11.4 11.9 12.1 12.6 12.9 13.4 13.6 13.9 14.1 14.6 15.1 15.6 15.9 16.1 16.3 16.6 16.8 17.3 19.8 20.0 20.5 21.0 21.5 26.9 27.3 27.6 27.8 28.1 28.4 28.6 28.8 29.1 29.3 29.6 30.1 30.6 31.1 33.8 34.3 34.5 34.8 35.0 36.3 43.2 44.7 46.7 4.9 5.1 5.2 5.4 5.5 5.7 5.8 6.1 6.2 6.3 6.4 6.6 6.9 7.1 7.2 7.3 7.4 7.5 7.6 7.9 9.0 9.1 9.3 9.5 9.8 12.2 12.4 12.5 12.6 12.7 12.9 13.0 13.1 13.2 13.3 13.4 13.6 13.9 14.1 15.3 15.5 15.7 15.8 15.9 16.5 19.6 20.3 21.2 *R eference section length for insulator configuration with Y-clevis (Y) and Ball (A) end fittings. To obtain the section length of other end fitting configurations please use the section length adjustment table. X1: Upper end fitting (earth side) X2: Bottom end fitting (high-voltage side) X3: Upper corona ring (earth side) X4: Bottom corona ring (high-voltage side) Section length adjustment table** Base end fittings: Y-clevis / Ball (catalog code: YA) Top end fitting (tower connection) Bottom end fitting (conductor connection) Catalog number End fittings Length change inches mm SML Type Standard Catalog number Length inches mm Y-clevis Eye YE -0.8 -21 36 klbs Ball 52-8 ANSI C29-2 A 5.2 132 Eye Ball EA 0.1 3 36 klbs Socket 52-8 ANSI C29-2 Q 5 127 Eye Eye EE -0.7 -18 36 klbs Clevis 52-10 ANSI C29-2 D 5.2 133 Socket Ball QA 1.1 29 36 klbs Tongue 52-10 ANSI C29-2 V 5.5 139 Clevis Ball DA 0.9 23 36 klbs Y-clevis ANSI C29-12 Y 6.1 156 Clevis Eye DE 0.1 2 36 klbs Eye 25 ANSI C29-12 E 6 153 Clevis Tongue DV 0.6 16 Tongue Tongue VV 0.4 10 ** T o determine the section length for an insulator with a different end fitting combination, please add or subtract the displayed length change in the table above. For configurations not shown, use the catalog number key or contact your Siemens representative. 8 Suspension insulators 3FL6 Specified mechanical load SML: 50 klbs (222 kN) Routine test load RTL: 25 klbs (111 kN) Rod diameter Ø: 7/8" (22 mm) 3FL silicone long rod insulators for suspension and tension applications are available in lengths appropriate for 60 kV through 550 kV. Length increments are 2.05 inches or 52 mm. Just a few selected insulator lengths are listed in the following catalog table. Custom lengths available on request. Catalog number Typical line voltage kV 3FLx- <72.5 72.5 72.5 72.5 72.5 72.5 123 123 123 145 145 145 170 170 170 170 170 170 170 170 245 245 245 245 245 300 300 300 300 300 300 300 300 362 362 362 362 362 362 420 420 420 420 420 420 550 550 550 Nominal polymer length -3X1X220-2X3X41 3FL6-044-3YA20-2XX1 3FL6-047-3YA20-2XX1 3FL6-050-3YA20-2XX1 3FL6-055-3YA20-2XX1 3FL6-058-3YA20-2XX1 3FL6-063-3YA20-2XX1 3FL6-066-3YA20-2XX1 3FL6-072-3YA20-2XX1 3FL6-074-3YA20-2XX1 3FL6-077-3YA20-2XX1 3FL6-080-3YA20-2XX1 3FL6-085-3YA20-2XX1 3FL6-091-3YA20-2XX1 3FL6-097-3YA20-2XX1 3FL6-100-3YA20-2XX1 3FL6-104-3YA20-2XX1 3FL6-107-3YA20-2XX1 3FL6-110-3YA20-2XX1 3FL6-113-3YA20-2XX1 3FL6-119-3YA20-2XX1 3FL6-122-3YA20-2XR1 3FL6-125-3YA20-2XR1 3FL6-131-3YA20-2XR1 3FL6-137-3YA20-2XR1 3FL6-143-3YA20-2XR1 3FL6-149-3YA20-2XR1 3FL6-155-3YA20-2XR1 3FL6-158-3YA20-2XR1 3FL6-161-3YA20-2XR1 3FL6-164-3YA20-2XR1 3FL6-168-3YA20-2XR1 3FL6-170-3YA20-2XR1 3FL6-174-3YA20-2XR1 3FL6-177-3YA20-2XR1 3FL6-180-3YA20-2XR1 3FL6-183-3YA20-2XR1 3FL6-186-3YA20-2XR1 3FL6-189-3YA20-2XR1 3FL6-193-3YA20-2XR1 3FL6-196-3YA20-2XR1 3FL6-200-3YA20-2RR1 3FL6-201-3YA20-2RR1 3FL6-203-3YA20-2RR1 3FL6-205-3YA20-2RR1 3FL6-213-3YA20-2RR1 3FL6-233-3YA20-2RR1 3FL6-244-3YA20-2RR1 3FL6-257-3YA20-2RR1 Section length* Arcing distance Leakage distance Low frequency flashover dry wet Critical impulse flashover Corona ring installation positive negative top / bottom Approx. net weight inches mm inches mm inches mm inches mm kV kV kV kV inches / inches lbs kg 24.2 26.2 28.2 32.3 34.4 38.5 40.5 44.6 46.7 48.7 50.8 54.9 59.0 63.1 65.1 67.1 69.2 71.2 73.3 77.4 79.4 81.5 85.6 89.7 93.8 97.9 101.9 104.0 106.0 108.1 110.1 112.2 114.2 116.3 118.3 120.4 124.5 128.6 132.7 136.8 140.8 142.9 144.9 147.0 157.2 181.8 194.1 210.5 614 666 718 822 874 978 1,030 1,134 1,186 1,238 1,290 1,394 1,498 1,602 1,654 1,706 1,758 1,810 1,862 1,966 2,018 2,070 2,174 2,278 2,382 2,486 2,590 2,642 2,694 2,746 2,798 2,850 2,902 2,954 3,006 3,058 3,162 3,266 3,370 3,474 3,578 3,630 3,682 3,734 3,994 4,618 4,930 5,346 35.5 37.5 39.6 43.7 45.7 49.8 51.9 56.0 58.0 60.1 62.1 66.2 70.3 74.4 76.4 78.5 80.5 82.6 84.6 88.7 90.8 92.8 96.9 101.0 105.1 109.2 113.3 115.3 117.4 119.4 121.5 123.5 125.6 127.6 129.7 131.7 135.8 139.9 144.0 148.1 152.2 154.2 156.3 158.3 168.6 193.1 205.4 221.8 902 954 1,006 1,110 1,162 1,266 1,318 1,422 1,474 1,526 1,578 1,682 1,786 1,890 1,942 1,994 2,046 2,098 2,150 2,254 2,306 2,358 2,462 2,566 2,670 2,774 2,878 2,930 2,982 3,034 3,086 3,138 3,190 3,242 3,294 3,346 3,450 3,554 3,658 3,762 3,866 3,918 3,970 4,022 4,282 4,906 5,218 5,634 25.3 27.3 29.4 33.5 35.5 39.6 41.7 45.8 47.8 49.9 51.9 56.0 60.1 64.2 66.2 68.3 70.3 72.4 74.4 78.5 78.8 80.8 84.9 89.0 93.1 96.6 100.7 102.8 104.8 106.9 108.9 111.0 113.0 115.1 117.1 119.2 123.2 127.3 131.4 133.8 137.9 139.9 141.9 144.0 154.2 178.0 190.3 206.7 643 695 747 851 903 1,007 1,059 1,163 1,215 1,267 1,319 1,423 1,527 1,631 1,683 1,735 1,787 1,839 1,891 1,995 2,002 2,054 2,158 2,262 2,366 2,455 2,559 2,611 2,663 2,715 2,767 2,819 2,871 2,923 2,975 3,027 3,131 3,235 3,339 3,398 3,502 3,554 3,606 3,658 3,918 4,522 4,834 5,250 67.0 73.4 79.8 92.6 99.0 111.8 118.2 131.0 137.4 143.8 150.2 163.0 175.8 188.6 195.0 201.4 207.9 214.3 220.7 233.5 239.9 246.3 259.1 271.9 284.7 297.5 310.3 316.7 323.1 329.5 335.9 342.3 348.7 355.1 361.5 367.9 380.7 393.5 406.3 419.1 431.9 438.3 444.7 451.1 483.1 560.0 598.4 649.6 1,702 1,865 2,027 2,353 2,515 2,840 3,003 3,328 3,491 3,653 3,816 4,141 4,466 4,792 4,954 5,117 5,279 5,442 5,605 5,930 6,093 6,255 6,580 6,906 7,231 7,556 7,881 8,044 8,206 8,369 8,532 8,694 8,857 9,019 9,182 9,345 9,670 9,995 10,320 10,646 10,971 11,133 11,296 11,459 12,272 14,223 15,199 16,499 285 302 318 351 368 400 417 450 466 483 499 532 563 594 609 624 640 655 670 701 717 732 755 777 800 822 845 856 867 878 890 901 912 923 935 946 950 955 959 963 967 970 972 974 985 1,006 1,006 1,006 219 238 257 294 313 351 370 407 426 445 463 501 527 552 565 578 590 603 616 641 654 667 675 683 691 699 706 710 714 718 722 726 730 734 738 742 747 752 757 763 768 770 773 775 788 814 814 814 465 493 521 578 606 662 691 747 775 803 831 888 952 1,016 1,048 1,081 1,113 1,145 1,177 1,241 1,273 1,306 1,367 1,428 1,490 1,551 1,612 1,643 1,673 1,704 1,735 1,765 1,796 1,827 1,857 1,888 1,955 2,021 2,088 2,155 2,221 2,254 2,288 2,321 2,487 2,820 2,820 2,820 465 493 522 580 608 666 695 752 781 810 838 896 956 1,017 1,047 1,077 1,108 1,138 1,168 1,229 1,259 1,289 1,355 1,420 1,485 1,551 1,616 1,649 1,681 1,714 1,747 1,779 1,812 1,845 1,877 1,910 1,973 2,036 2,100 2,163 2,226 2,258 2,289 2,321 2,479 2,795 2,795 2,795 x/x x/x x/x x/x x/x x/x x/x x/x x/x x/x x/x x/x x/x x/x x/x x/x x/x x/x x/x x/x x / Ø 8.3 x / Ø 8.3 x / Ø 8.3 x / Ø 8.3 x / Ø 8.3 x / Ø 13 x / Ø 13 x / Ø 13 x / Ø 13 x / Ø 13 x / Ø 13 x / Ø 13 x / Ø 13 x / Ø 13 x / Ø 13 x / Ø 13 x / Ø 13 x / Ø 13 x / Ø 13 Ø 8.3 / Ø 13 Ø 8.3 / Ø 13 Ø 8.3 / Ø 13 Ø 8.3 / Ø 13 Ø 8.3 / Ø 13 Ø 8.3 / Ø 13 Ø 8.3 / Ø 16 Ø 8.3 / Ø 16 Ø 8.3 / Ø 16 10.9 11.1 11.4 11.9 12.1 12.6 12.9 13.4 13.6 13.9 14.1 14.6 15.1 15.6 15.9 16.1 16.3 16.6 16.8 17.3 19.8 20.0 20.5 21.0 21.5 26.9 27.3 27.6 27.8 28.1 28.4 28.6 28.8 29.1 29.3 29.6 30.1 30.6 31.1 33.8 34.3 34.5 34.8 35.0 36.3 43.2 44.7 46.7 4.9 5.1 5.2 5.4 5.5 5.7 5.8 6.1 6.2 6.3 6.4 6.6 6.9 7.1 7.2 7.3 7.4 7.5 7.6 7.9 9.0 9.1 9.3 9.5 9.8 12.2 12.4 12.5 12.6 12.7 12.9 13.0 13.1 13.2 13.3 13.4 13.6 13.9 14.1 15.3 15.5 15.7 15.8 15.9 16.5 19.6 20.3 21.2 *R eference section length for insulator configuration with Y-clevis (Y) and Ball (A) end fittings. To obtain the section length of other end fitting configurations please use the section length adjustment table. X1: Upper end fitting (earth side) X2: Bottom end fitting (high-voltage side) X3: Upper corona ring (earth side) X4: Bottom corona ring (high-voltage side) Section length adjustment table** Base end fittings: Y-clevis / Ball (catalog code: YA) Top end fitting (tower connection) Bottom end fitting (conductor connection) Catalog number End fittings Length change inches mm SML Type Standard Catalog number Length inches mm Y-clevis Eye YE -0.8 -21 50 klbs Ball 52-11 ANSI C29-2 A 5.2 132 Eye Ball EA 0.1 3 50 klbs Socket 52-11 ANSI C29-2 Q 5 127 Eye Eye EE -0.7 -18 50 klbs Clevis 52-12 ANSI C29-2 D 5.5 139 Socket Ball QA 1.1 29 50 klbs Tongue 52-12 ANSI C29-2 V 6.1 154 Clevis Ball DA 0.7 17 50 klbs Y-clevis ANSI C29-12 Y 6.1 156 Clevis Eye DE -0.2 -4 50 klbs Eye 25 ANSI C29-12 E 6 153 Clevis Tongue DV -0.2 -5 Tongue Tongue VV -0.8 -20 ** T o determine the section length for an insulator with a different end fitting combination, please add or subtract the displayed length change in the table above. For configurations not shown, use the catalog number key or contact your Siemens representative. 9 Order number 3 F L 4 066 – 3 Y A 1 0 – 2 X X 1 Polymer suspension/tension insulator: 3 F L Specified mechanical load SML [klbs]: 25 klbs (111 kN) 3 30 klbs (133 kN) 4 36 klbs (160 kN) 5 50 klbs (222 kN) 6 Lightning impulse withstand voltage (1.2/50µs, dry) LIWV/10 [kV], for example: if LIWV is 661 kV, then enter 066: – Internal usage: 066 3 Upper end fitting (ground side): SML class / klbs: according to ANSI C29.12 and ANSI C29.2 25303650 /kN 111133160222 Ball, size acc. to ANSI C29.2: 52-5 52-5 52-8 52-11 A Socket, size acc. to ANSI C29.2: 52-5 52-5 52-8 52-11 Q Clevis, size acc. to ANSI C29.2: 52-6 52-6 52-10 52-12 D Tongue, size acc. to ANSI C29.2: 52-6 52-6 52-10 52-12 V Eye, size acc. to ANSI C29.12: 25 klbs 25 klbs 40 klbs 40 klbs E Y-clevis, size acc. to ANSI C29.12: 25 klbs 25 klbs 40 klbs 40 klbs Y Special (other end fitting types available on request): Z Bottom end fitting (high-voltage side): SML class / klbs: 25303650 Torsion according to ANSI C29.12 and ANSI C29.2 Angle /kN 111 133 160 222 Ball, size acc. to ANSI C29.2: 52-5 52-5 52-8 52-11 n/a ° A Socket, size acc. to ANSI C29.2: 52-5 52-5 52-8 52-11 n/a Q Clevis, size acc. to ANSI C29.2: 52-6 52-6 52-10 52-12 0° 90° D G Tongue, size acc. to ANSI C29.2: 52-6 52-6 52-10 52-12 0° 90° V W Eye, size acc. to ANSI C29.12: 25 klbs 25 klbs 40 klbs 40 klbs 0° 90° E H Y-clevis, size acc. to ANSI C29.12: 25 klbs 25 klbs 40 klbs 40 klbs 0° 90° Special (other end fitting types available on request): Y X Z FRP core rod diameter Ø: 5/8" (for 3FL3, 3FL4) 1 7/8" (for 3FL5, 3FL6) 2 Internal usage: 0 – Standard: ANSI C29.11, ANSI C29.12 2 Accessories on ground end: Arcing horn H Corona ring R No accessories required X Special Z Accessories on line end: Arcing horn H Corona ring R No accessories required X Special Z Application: Single string 1 Double string 2 V-string 5 Special 9 10 Europe North America Burlington, Ontario Richland, Mississippi Oslo Moscow Gebze, Kocaeli Espoo Vienna Athens Dublin Grenoble Bucharest Manchester Ljubljana Barcelona Asia Upplands Väsby, Huizingen Sofia Almaty Seoul Stockholm Bratislava Madrid Gurgaon Shanghai Den Haag Zagreb Amadora Hanoi Hong Kong Bangkok Dhaka Manila Abu Dhabi Petaling Jaya Riyadh Istanbul El Marques, Querétaro Santo Domingo Jakarta San Jose Ciudad de Guatemala Africa South America Bogota Algiers Casablanca Tunis Quito Cairo Lima Isolo, Lagos Santa Cruz de la Sierra Douala Australia Jundiaí, São Paulo Addis Ababa Macquarie Park, NSW, Santiago Nairobi Buenos Aires Ngaliema, Kinshasa Sydney Ingombota Luanda Maputo Halfway House Marking and nameplate of 3FL insulators A nameplate is installed on each 3FL insulator when it successfully passes the mechanical routine test. It is a weather- and UV-proof stainless steel band with locking system, placed on the ground end fitting of the insulator. The etched marking includes: catalog number, SML, RTL, CIF, creepage distance, end fittings designation, and production date code. Packaging 3FL insulators are packaged in wooden crates with the following dimensions: width is 44 inches (1,120 mm), height is equal to or lower than 37.16 inches (944 mm), the length is determined by the insulator length. The maximum weight of one crate is 2,000 pounds (900 kg). 11 Published by and copyright © 2012: Siemens AG Energy Sector Freyeslebenstrasse 1 91058 Erlangen, Germany Siemens AG Energy Sector Power Transmission Division High Voltage Products Nonnendammallee 104 13629 Berlin, Germany www.siemens.com/energy/insulators Please contact us at: Phone: +49 30 386 33 222 Fax: +49 30 386 26 721 E-mail: [email protected] US Location Siemens Energy, Inc. Power Transmission Division 444 Highway 49 South Richland, MS 39218 www.siemens.com/energy/insulators Please contact us at: Toll-free:+1 (877) 742-3309 Phone: +1 (601) 932-9800 Power Transmission Division Order No. E50001-G630-A216-X-4AUS Printed in Germany Dispo 30002, c4bs No. 7457 fb 5022 WÜ 471777 WS 08121.0 Printed on elementary chlorine-free bleached paper. All rights reserved. Trademarks mentioned in this document are the property of Siemens AG, its affiliates, or their respective owners. Subject to change without prior notice. The information in this document contains general descriptions of the technical options available, which may not apply in all cases. The required technical options should therefore be specified in the contract.