TE10 Series UL Certificate

Issue Date:
2015-06-08
Page 1 of 8
Report Reference #
E300305-A101-UL
UL TEST REPORT AND PROCEDURE
Standard:
Certification Type:
CCN:
UL 60950-1, 2nd Edition, 2014-10-14 (Information Technology
Equipment - Safety - Part 1: General Requirements)
CAN/CSA C22.2 No. 60950-1-07, 2nd Edition, 2014-10 (Information
Technology Equipment - Safety - Part 1: General Requirements)
Listing
QQGQ, QQGQ7 (Power Supplies for Information Technology
Equipment Including Electrical Business Equipment)
Switching Power Supply
BX020XYYX, XE20XYYXXXXX, BX010XYYX, XE10XYYXXXXX
(Where X may be alphanumeric, "for marketing purpose and no
impact safety related critical components and constructions", where
YY may any number 05 through 48)
BX020XYYX, XE20XYYXXXXX, BX010XYYX, XE10XYYXXXXX
series;
Product:
Model:
Rating:
Input Rating: 100-240 Vac, 50-60 Hz, 0.5 A
Output Rating: 5 Vdc, 2.0A/3.0A or
5.9Vdc, 1.67A/2.5A or
7.5Vdc, 1.33A/2.0A
9 Vdc, 1.33A/2.0A or
12 Vdc, 1.0A/1.5A or
15 Vdc, 0.8A/1.2A or
18 Vdc, 0.67A / 1.0A or
24 Vdc, 0.5A / 0.83A or
48 Vdc, 0.25 A./ 0.42A or
5Vdc/3.0A~48Vdc /0.25A
Applicant Name and Address:
BRIDGEPOWER CORP
(GOSAEK-DONG) 16 OMOKCHEN-RO 132BEON-GIL
GWONSEON-GU
SUWON-SI GYEONGGI 441-813 KOREA
This is to certify that representative samples of the products covered by this Test Report have been investigated in accordance with the
above referenced Standards. The products have been found to comply with the requirements covering the category and the products are
judged to be eligible for Follow-Up Service under the indicated Test Procedure. The manufacturer is authorized to use the UL Mark on
such products which comply with this Test Report and any other applicable requirements of UL LLC ('UL') in accordance with the FollowUp Service Agreement. Only those products which properly bear the UL Mark are considered as being covered by UL's Follow-Up
Service under the indicated Test Procedure.
The applicant is authorized to reproduce the referenced Test Report provided it is reproduced in its entirety.
Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL.
Prepared by:
InYoung Hwang
Reviewed by: SeungTae Kim
Copyright © 2015
Issue Date:
2015-06-08
Page 2 of 8
Report Reference #
E300305-A101-UL
Supporting Documentation
The following documents located at the beginning of this Procedure supplement the requirements of this Test
Report:
A. Authorization - The Authorization page may include additional Factory Identification Code markings.
B. Generic Inspection Instructions i. Part AC details important information which may be applicable to products covered by this Procedure.
Products described in this Test Report must comply with any applicable items listed unless otherwise
stated in the body of this Test Report.
ii. Part AE details any requirements which may be applicable to all products covered by this Procedure.
Products described in this Test Report must comply with any applicable items listed unless otherwise
stated in the body of each Test Report.
iii. Part AF details the requirements for the UL Certification Mark which is not controlled by the technical
standard used to investigate these products. Products are permitted to bear only the Certification
Mark(s) corresponding to the countries for which it is certified, as indicated in each Test Report.
Product Description
Switching Mode Power Supply(AC/DC adaptor), consists of electronic components mounted on PWB, a
switching transformer and electronic components mounted on PWB, housed with a plastic enclosure.
Model Differences
Models XE20 series is identical to models BX020 series except for model designation.
Models XE10 series is identical to models BX010 series except for model designation.
Models BX010 series is identical to models BX020 series except for model designation and rated output
current (See power supply reference page for detail).
Nomenclature
B X 020 X YY X,
(a)
(b) (c) (d)
B X 010 X YY X
(a) (b) (c) (d)
(a) Family Related Designs
X is A-Z
(b) Output
X is S (S=Single)
(c) Output Voltage
05, 06, 07, 09, 12, 15, 18, 24, 48 , 05 through 48
(d) Standard Input Cord Options
F : (Class I = IEC320-C14)
Q: (Class II = IEC320-C18)
N: ((Class II = IEC320-C8)
XE
(a)
10 X YY XX X XX, XE
(b) (c) (d) (e) (f) (a)
20 X YY XX X XX
(b) (c) (d) (e) (f)
(a) Family Related Designs
X is A-Z
(b) AC Ground Configuration
A to Z (Standard)
(c) Output Voltage
05, 06, 07, 09, 12, 15, 18, 24, 48 , 05 through 48
Issue Date:
2015-06-08
Page 3 of 8
Report Reference #
E300305-A101-UL
(d) Standards Output Cord Options
Number : 00 thru 99
(e) Standard Input Connector Options
F : (Class I = IEC320-C14)
Q: (Class II = IEC320-C18)
N: ((Class II = IEC320-C8)
(f) Model Configuration
Number : 00 thru 99
Technical Considerations

Equipment mobility : movable

Connection to the mains : pluggable A

Operating condition : continuous

Access location : N/A

Over voltage category (OVC) : OVC II

Mains supply tolerance (%) or absolute mains supply values : +10%, -10%

Tested for IT power systems : Yes (for Norway only)

IT testing, phase-phase voltage (V) : 230 Vac

Class of equipment : Class I (earthed) or Class II (double insulated)

Considered current rating of protective device as part of the building installation (A) : 20

Pollution degree (PD) : PD 2

IP protection class : IP 22

Altitude of operation (m) : Up to 5000m

Altitude of test laboratory (m) : N/A

Mass of equipment (kg) : 160g

The product was submitted and evaluated for use at the maximum ambient temperature (Tma)
permitted by the manufacturer’s specification of: 40

The means of connection to the mains supply is: Detachable power cord

The product is intended for use on the following power systems: TN

The equipment disconnect device is considered to be: Plug, Appliance inlet

The product was investigated to the following additional standards: EN 60950-1:2006 + A11:2009 +
A1:2010 + A12:2011 + A2:2013 (which includes all European national differences, including those
specified in this test report).

The following circuit locations (with circuit/schematic designation) were investigated as a limited
power source (LPS): All outputs
Additional Information
4786848497
Max. Normal Load Condition: Rated output current
E300305-A98-CB-1, Correction1
-Add DK deviation due to missing in the original report
Additional Standards
The product fulfills the requirements of: N/A
Issue Date:
2015-06-08
Page 4 of 8
Report Reference #
E300305-A101-UL
Markings and instructions
Clause Title
Marking or Instruction Details
1.7.1 Power rating Ratings
1.7.1 Power
rating - Company
identification
Ratings (voltage, frequency/dc, current)
Listee's or Recognized company's name, Trade Name, Trademark or File
Number
1.7.1 Power
rating - Model
Model Number
1.7.1 Power
rating - Class II symbol
Symbol for Class II construction
Special Instructions to UL Representative
N/A
Production-Line Testing Requirements
Electric Strength Test Special Constructions - Refer to Generic Inspection Instructions, Part AC for
further information.
Model
Component
Removable
Parts
Test probe location
V
rms
V dc
Test Time,
s
N/A
Earthing Continuity Test Exemptions - This test is not required for the following models:
all models
Electric Strength Test Exemptions - This test is not required for the following models:
Electric Strength Test Component Exemptions - The following solid-state components may
disconnected from the remainder of the circuitry during the performance of this test:
Sample and Test Specifics for Follow-Up Tests at UL
Model
N/A
Component
Material
Test
Sample(s)
Test
Specifics