PENT1080 CSA/UL 60950-1, 2nd Ed. Cert

Issue Date:
2010-11-19
Page 1 of 10
Report Reference #
E136791-A20-UL
UL TEST REPORT AND PROCEDURE
Standard:
Certification Type:
CCN:
UL 60950-1, 2nd Edition, 2007-03-27 (Information Technology
Equipment - Safety - Part 1: General Requirements)
CSA C22.2 No. 60950-1-07, 2nd Edition, 2007-03 (Information
Technology Equipment - Safety - Part 1: General Requirements)
Power Supplies for Information Technology Equipment Including
Electrical Business Equipment
QQGQ, QQGQ7
PoE Injectors
PENT1080X1X2X3X4X5; where X1 = A, B, C, or D; X2 = 56; X3 = 0099, X4 = F, N, or Q; and X5 = 0-9.
Input: 100-240 V ac, 1.8 A, 50-60 Hz
Product:
Model:
Rating:
Output: 56 Vdc, 1.42 A
Applicant Name and Address:
SL POWER ELECTRONICS CORP
BLDG A
6050 KING ST
VENTURA CA 93003
UNITED STATES
This is to certify that representative samples of the products covered by this Test Report have been investigated in accordance with the
above referenced Standards. The products have been found to comply with the requirements covering the category and the products are
judged to be eligible for Follow-Up Service under the indicated Test Procedure. The manufacturer is authorized to use the UL Mark on
such products which comply with this Test Report and any other applicable requirements of Underwriters Laboratories Inc. ('UL') in
accordance with the Follow-Up Service Agreement. Only those products which properly bear the UL Mark are considered as being
covered by UL's Follow-Up Service under the indicated Test Procedure.
The applicant is authorized to reproduce the referenced Test Report provided it is reproduced in its entirety.
Any information and documentation involving UL Mark services are provided on behalf of Underwriters Laboratories Inc. (UL) or any
authorized licensee of UL.
Prepared by:
Reviewed by:
David Feusier
Underwriters Laboratories Inc.
Anh Nguyen
Underwriters Laboratories Inc.
Copyright © 2010
Issue Date:
2010-11-19
Page 2 of 10
Report Reference #
E136791-A20-UL
Supporting Documentation
The following documents located at the beginning of this Procedure supplement the requirements of this Test
Report:
A. Authorization - The Authorization page may include additional Factory Identification Code markings.
B. Generic Inspection Instructions i. Part AC details important information which may be applicable to products covered by this Procedure.
Products described in this Test Report must comply with any applicable items listed unless otherwise
stated in the body of this Test Report.
ii. Part AE details any requirements which may be applicable to all products covered by this Procedure.
Products described in this Test Report must comply with any applicable items listed unless otherwise
stated in the body of each Test Report.
iii. Part AF details the requirements for the UL Certification Mark which is not controlled by the technical
standard used to investigate these products. Products are permitted to bear only the Certification
Mark(s) corresponding to the countries for which it is certified, as indicated in each Test Report.
Product Description
AC to DC Switching Power Supplies, that are also known as PoE Injectors. The products described in this
report are Special Application - Functional Earthing, and Class II power supplies, that provide Power over
Ethernet (PoE) to other devices. The are intended to transfer data and power to another device, and do not
connect to outside plant (intra-building). Each unit has two outputs ports (RJ-45 type connectors).
Model Differences
Model Designation PENT1080X1X2X3X4X5; where X1 = A, B, C, or D; X2 = 56; X3 =00-99, X4 = F, N, or Q; X5 = 0-9.
X1 = PoE options A, B, C, D
X2 = Output voltage - 56V
X3 = 00-99 non safety related
X4 = appliance inlet: F - Special Application - Functional Earthing (C14), N - Class II (C8), Q - Class II (C18)
X5 = 0-9 non safety related
Differences between Special Application -Functional Earthing, and Class II models:
Functional Earthing units are provided with a three pin appliance inlet, suffix "F". Functional Earthing units
are provided with a conductor that terminates at the earthing terminal of the appliance inlet, and terminates at
primary location "H3" on the PWB.
-Class II units are provided with a two pin appliance inlet, suffix "N" or "Q". Class II units do not utilize the
Functional Earthing conductor.
PoE options A, B, C, D have alternate components in SELV, which do not affect safety considerations.
Technical Considerations
§
Equipment mobility : transportable
§
Connection to the mains : pluggable A
§
Operating condition : continuous
§
Access location : operator accessible
Issue Date:
2010-11-19
Page 3 of 10
Report Reference #
E136791-A20-UL
§
Over voltage category (OVC) : OVC II
§
Mains supply tolerance (%) or absolute mains supply values : +10%, -10%
§
Tested for IT power systems : Yes
§
IT testing, phase-phase voltage (V) : 230
§
Class of equipment : Special Application - Functional Earthing, and Class II
§
Considered current rating (A) : 20 A (Branch Circuit)
§
Pollution degree (PD) : PD 2
§
IP protection class : IP X0
§
Altitude of operation (m) : up to 2000
§
Altitude of test laboratory (m) : less than 2000
§
Mass of equipment (kg) : 0.4
§
The product was submitted and evaluated for use at the maximum ambient temperature (Tma)
permitted by the manufacturer’s specification of: 40°C
§
The means of connection to the mains supply is: Detachable power cord, Pluggable A
§
The product is intended for use on the following power systems: TN, IT
§
The equipment disconnect device is considered to be: Appliance inlet
§
The product was investigated to the following additional standards: EN 60950-1:2006 + Amendment
11 (2009) (which includes all European national differences, including those specified in this test
report).
§
The following circuit locations (with circuit/schematic designation) were investigated as a limited
power source (LPS): All outputs (56 Vdc outputs)
§
The following are available from the Applicant upon request: Specific data sheets for LED indicators
that are class I and operate at wavelength in the 400-710 nm range., Installation (Safety) Instructions
/ Manual
§
The output ports (RJ-45 connectors) were not evaluated for connection to outside plant, and should
Issue Date:
2010-11-19
Page 4 of 10
Report Reference #
E136791-A20-UL
only be connected to Power Over Ethernet (PoE) networks and devices that do not directly exit the
building.
§
Some models employ Functional Earthing per 2.6.2. As anticipated by the NOTE for 1.2.4, it does
not conform to one of the common Classes (I, II, or III). The following insulation is provided between
the primary and accessible dead metal parts and circuits: Reinforced.
Additional Information
Samples of Models PENT1080A5600N01, PENT1080B5600Q01, and PENT1080D5600N01 were tested and
considered representative of all other models in the series.
The Applicant has requested that the Electrical Schematics not be included in this report for proprietary
purposes. Electrical Schematics can be obtained from the Applicant upon request.
Nameplate labels provided in this report are for reference, and are considered representative of the entire
series.
PoE not for outside plant (or intra-bulding) - The installation instructions indicates that the unit is to be
connected only to PoE networks without routing to the outside plant.
Markings and instructions
Clause Title
Marking or Instruction Details
Power rating - Ratings
Ratings (voltage, frequency/dc, current)
Power rating Company identification
Power rating -
Listee's or Recognized company's name, Trade Name, Trademark or File
Number
Model Number
Model
Power rating Class II symbol
Symbol for Class II construction
(60417-2-IEC-5172)
Limited Power Source
(LPS) Marking
Installation
Instructions for Power
Optional. "LPS" or "Limited Power Source" maybe marked on the unit.
The installation instructions shall indicate that the unit is to be connected
only to Power Over Ethernet or PoE networks, without routing to the outside plant.