UL TEST REPORT AND PROCEDURE
Standard:
Certification Type:
CCN:
UL 60950-1, 2nd Edition, 2014-10-14 (Information Technology
Equipment - Safety - Part 1: General Requirements)
CAN/CSA C22.2 No. 60950-1-07, 2nd Edition, 2014-10 (Information
Technology Equipment - Safety - Part 1: General Requirements)
Unlisted Component
QQGQ3, QQGQ9 (Power Supplies for Information Technology
Equipment Including Electrical Business Equipment)
Switching Power Supply
S-BX030XYYX, S-XE30XYYXXXXX, S-BX040XYYX, SXE40XYYXXXXX (Where X may be alphanumeric, "for marketing
purpose and no impact safety related critical components and
constructions", where YY may any number 05 through 48)
S-BX030XYYX, S-XE30XYYXXXXX, S-BX040XYYX, SXE40XYYXXXXX series;
Product:
Model:
Rating:
Input Rating: 100-240 Vac, 50-60 Hz, 1.2 A
Output Rating: 5 Vdc, 4.0A/5.0A or
9 Vdc, 3.0A/4.0A or
12 Vdc, 2.5A/3.4A or
15 Vdc, 2.0A/2.7A or
18 Vdc, 1.67A / 2.22A or
24 Vdc, 1.33A / 1.7A or
48 Vdc, 0.63 A./ 0.83A or
5Vdc/4.0A~48Vdc /0.83A
Applicant Name and Address:
BRIDGEPOWER CORP
(GOSAEK-DONG) 16 OMOKCHEN-RO 132BEON-GIL
GWONSEON-GU
SUWON-SI GYEONGGI 441-813 KOREA
Sample(s) of the components covered by this Test Report have been found to comply with the requirements covering the category for
factory installed components for this Applicant's Listed, Classified, or Recognized basic equipment where the acceptability of the
combination is determined by UL LLC ('UL') and where the products are judged to be eligible for Follow-Up Service under the indicated
Test Procedure. The manufacturer is authorized to use the specific identification marking described in the Follow-Up Service Procedure
on such products which comply with said Procedure and any other applicable requirements. Only those products which properly bear the
above specific identification marking are considered as being covered by UL's Follow-Up Service under the indicated Test Procedure.
Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL.
Prepared by:
InYoung Hwang
Reviewed by: HyeongKyun Park
Copyright © 2015
Issue Date:
2015-10-29
Page 2 of 11
Report Reference #
E300305-A111-UL
Supporting Documentation
The following documents located at the beginning of this Procedure supplement the requirements of this Test
Report:
A. Authorization - The Authorization page may include additional Factory Identification Code markings.
B. Generic Inspection Instructions i. Part AC details important information which may be applicable to products covered by this Procedure.
Products described in this Test Report must comply with any applicable items listed unless otherwise
stated in the body of this Test Report.
ii. Part AE details any requirements which may be applicable to all products covered by this Procedure.
Products described in this Test Report must comply with any applicable items listed unless otherwise
stated in the body of each Test Report.
iii. Part AF details the requirements for the UL Certification Mark which is not controlled by the technical
standard used to investigate these products. Products are permitted to bear only the Certification
Mark(s) corresponding to the countries for which it is certified, as indicated in each Test Report.
Product Description
Switching Mode Power Supply(AC/DC adaptor), consists of electronic components mounted on PWB, a
switching transformer and electronic components mounted on PWB
Model Differences
Models S-XE40 series is identical to models S-BX040 series except for model designation.
Models S-XE30 series is identical to models S-BX030 series except for model designation.
Models S-BX030 series is identical to models S-BX040 series except for model designation and rated output
current
Nomenclature
S-B X 040 X YY X, S-B X 030 X YY X
(a)
(b) (c) (d)
(a) (b) (c) (d)
(a) Family Related Designs
X is A-Z
(b) Output
X is S (S=Single)
(c) Output Voltage
05, 09, 12, 15, 18, 24, 48 , 05 through 48
(d) Standard Input Cord Options
Can be F or Q or N or B or H or G or M or C for input plug type. Photographs for each plug-type configuration
F : (Class I = IEC320-C14)
Q: (Class II = IEC320-C18)
N: ((Class II = IEC320-C8)
B: Class II North America, UK, Korea, Australia, European, China, Japan Changeable Direct-plug-in type
C: Class II - direct-plug-in for North America, China, Japan
H- Class II direct-plug-in for Australia(AS/NZS 3112) & Argentina
G- Class II direct-plug-in for British(BS 1363) & Singapore
M- Class II direct-plug-in for European(CEE /16)] & Korea
S-XE
(a)
30 X YY XX X XX, S-XE
(b) (c) (d) (e) (f)
(a)
(a) Family Related Designs
40 X YY XX X XX
(b) (c) (d) (e) (f)
Issue Date:
2015-10-29
Page 3 of 11
Report Reference #
E300305-A111-UL
X is A-Z
(b) AC Ground Configuration
A to Z (Standard)
(c) Output Voltage
05, 09, 12, 15, 18, 24, 48 , 05 through 48
(d) Standards Output Cord Options
Number : 00 thru 99
(e) Standard Input Connector Options
Can be F or Q or N or B or H or G or M or C for input plug type. Photographs for each plug-type configuration
F : (Class I = IEC320-C14)
Q: (Class II = IEC320-C18)
N: ((Class II = IEC320-C8)
B: Class II North America, UK, Korea, Australia, European, China, Japan Changeable Direct-plug-in type
C: Class II - direct-plug-in for North America, China, Japan
H- Class II direct-plug-in for Australia(AS/NZS 3112) & Argentina
G- Class II direct-plug-in for British(BS 1363) & Singapore
M- Class II direct-plug-in for European(CEE /16)] & Korea
(f) Model Configuration
Number : 00 thru 99
Technical Considerations

Equipment mobility : movable

Connection to the mains : pluggable A

Operating condition : continuous

Access location : N/A

Over voltage category (OVC) : OVC II

Mains supply tolerance (%) or absolute mains supply values : +10%, -10%

Tested for IT power systems : No

IT testing, phase-phase voltage (V) : -

Class of equipment : Class I (earthed) or Class II (double insulated)

Considered current rating of protective device as part of the building installation (A) : 20

Pollution degree (PD) : PD 2

IP protection class : IP X0

Altitude of operation (m) : Up to 5000m

Altitude of test laboratory (m) : N/A

Mass of equipment (kg) : max 200g

The product was submitted and evaluated for use at the maximum ambient temperature (Tma)
permitted by the manufacturer’s specification of: 40

The product is intended for use on the following power systems: TN

The following circuit locations (with circuit/schematic designation) were investigated as a limited
power source (LPS): All outputs
Engineering Conditions of Acceptability
For use only in or with Applicant's complete equipment where the acceptability is determined by UL LLC.
When installed in an end-product, consideration must be given to the following:

The end-product Electric Strength Test is to be based upon a maximum working voltage of: PrimarySELV: _292 Vrms, 620 Vpk,
Issue Date:
2015-10-29
Page 4 of 11
Report Reference #
E300305-A111-UL

The following secondary output circuits are SELV: output

The following secondary output circuits are at non-hazardous energy levels: output

The following secondary output circuits are supplied by a Limited Power Source: output

The maximum investigated branch circuit rating is: 20 A

The investigated Pollution Degree is: 2

Proper bonding to the end-product main protective earthing termination is: Required(for ClassI)

An investigation of the protective bonding terminals has: Been conducted

The following magnetic devices (e.g. transformers or inductor) are provided with an OBJY2 insulation
system with the indicated rating greater than Class A (105°C): T1(Class B)

The following end-product enclosures are required: Electrical, Fire, Mechanical
Additional Information
4787080329
The assembly is manufactured by WENDENG JEIL ELECTRONICS Co LTD(All requirements associate with
this report is evaluated as UL report E300305-A110)
Additional Standards
The product fulfills the requirements of: N/A
Markings and instructions
Clause Title
Marking or Instruction Details
Power rating - Model
Model Number
Fuses - Rating
Rated current and voltage and type located on or adjacent to fuse or
fuseholder.
Special Instructions to UL Representative
Products complying with the description in this procedure are authorized to be marked with the following split
inspection marking and shipped to the factory locations covered by File E300305, Volume X1.
This marking is to be applied to the products.
Products not in compliance with the description of this procedure are not authorized to bear this marking and
are not authorized for use in products that bear the UL Listing Mark.
Split Inspection Marking:
S-BX040XYYX, S-XE40XYYXXXXX, S-BX030XYYX, S-XE30XYYXXXXX
Issue Date:
2015-10-29
Page 5 of 11
Report Reference #
E300305-A111-UL
Production-Line Testing Requirements
Electric Strength Test Special Constructions - Refer to Generic Inspection Instructions, Part AC for
further information.
Model
Component
Removable
Parts
Test probe location
All model
T1
N/A
Primary to Secondary
V
rms
300
0
V dc
Test Time,
s
4242
1
Earthing Continuity Test Exemptions - This test is not required for the following models:
all models
Electric Strength Test Exemptions - This test is not required for the following models:
Electric Strength Test Component Exemptions - The following solid-state components may
disconnected from the remainder of the circuitry during the performance of this test:
Sample and Test Specifics for Follow-Up Tests at UL
Model
N/A
Component
Material
Test
Sample(s)
Test
Specifics
Issue Date:
2015-10-29
Page 6 of 11
Report Reference #
1.5.1
Object/part or
Description
TABLE: list of critical components
Manufacturer/
type/model
trademark
Enclosure - Optional
SAMSUNG SDI CO
LTD
Appliance Inlet
(Class I)
Appliance Inlet (Class II)
Appliance Inlet
(Class II) - Alternate
Fuse (F1)
Fuse (F1) - Alternate
Fuse (F1) - Alternate
Fuse (F2) (Optional)
Fuse (F2) (Optional) Alternate
Fuse (F2) (Optional) Alternate
Thermister (TH1)
technical data
Product Category
CCN(s)
QMFZ2
Rong Feng Industrial SS-120
Overall Sized
approx. 95.0 by
54.0 by 32mm. Min 2.0
mm
thickness, V-0.
RTI = 130
degreeC
Min.10A, 250V
Pass
Required
Supplement ID
Marks of
Conformity
UL(E115797)
AXUT2
UL(E102641)
Rong Feng Industrial RF-180
Rong Feng Industrial SS-120A
Min.2.5A, 250V
Min.10A, 250V
AXUT2
AXUT2
UL(E102641)
UL(E102641)
LITTELFUSE
WICKMANN WERKE
COOPER
BUSSMANN LLC
Hollyland co., ltd.
LITTELFUSE
WICKMANN WERKE
COOPER
BUSSMANN LLC
Hollyland co., ltd.
392
Rated 250 V, 2.0A
JDYX2
UL(E67006)
SS-5
Rated 250 V, 2.0A
JDYX2
UL(E19180)
5ET
392
Rated 250 V, 2.0A
Rated 250 V, 2.0A
JDYX2
JDYX2
UL(E156471)
UL(E67006)
SS-5
Rated 250 V, 2.0A
JDYX2
UL(E19180)
5ET
Rated 250 V, 2.0A
JDYX2
UL(E156471)
NTC, 5ohm at 25°C.
Tested in the
equipment
Tested in the
equipment
-
VZCA2
UL(E332687)
VZCA2
UL(330256)
HN-1064(+)
Varistor (VAR1)
(Optional)
DSC ELECTRONICS DSC-5D-9
CO LTD
SCK-083
THINKING
ELECTRONIC
INDUSTRIAL CO
LTD
Amotech
10D471 &
14D471
Varistor (VAR1)
Success Electronics
Thermister (TH1)
E300305-A111-UL
SVR10D471K &
NTC, 5ohm at 25°C.
Rated 470 V, (line-to-line),
Overall dimension 10 mm &
14mm.
Rated 470 V, (line-to-line),
-
Issue Date:
2015-10-29
Page 7 of 11
(Optional) _Alternate
Report Reference #
E300305-A111-UL
SVR14D471K
X-capacitor (CX1) (Line
to Line)
Carli
X-capacitor (CX1) (Line
to Line) - Alternate
Iskra
X-capacitor (CX1) (Line
to Line) - Alternate
Pilkor
X-capacitor (CX1) (Line
to Line) - Alternate
Okaya
X-capacitor (CX1) (Line
to Line) - Alternate
Sunil
Line Filter (LF1)
BridgePower &
Wendeng Jeil &TNC
Line Filter (LF1) Alternate
TNC
Y-Capacitors (CY1,
CY2)
APEX INTEC
Y-Capacitors (CY1,
CY2) – Alternate
DONGIL
Overall dimension 10 mm &
14mm.
MPX
Rated 275V, Max. 0.47 uF.
Marked with X1 or X2. Meets
IEC/EN60384-14.
KNB1562 or 1563 Rated 250V, Max. 0.47 uF.
Marked with X1 or X2. Meets
IEC/EN60384-14.
PCX2 335M or
Rated 250V, Max. 0.47 uF.
PCX2 337
Marked with X1 or X2. Meets
IEC/EN60384-14.
LE
Rated 250V, Max. 0.47 uF.
Marked with X1 or X2. Meets
IEC/EN60384-14.
436D
Rated 250V, Max. 0.47 uF.
Marked with X1 or X2. Meets
IEC/EN60384-14.
3025701
Core: Ferrite, 16.5 by 10.5 by
20 mm, Coils: Polyurethane
wire min130°C. Bobbin:
(QMFZ2), Hexian Specialty
Chemicals, type PM9820 , V-0,
150°C. See Enclosure for
details.
CV408360SH
Core: Ferrite, 16.5 by 10.5 by
20 mm, Coils: Polyurethane
wire min130°C. Bobbin:
(QMFZ2), Hexian Specialty
Chemicals, type PM9820 , V-0,
150°C. See Enclosure for
details.
NK
Rated 250V, Max. 2200 pF
Marked with Y1. Meets
IEC/EN60384-14.
DA
Rated 250V, Max. 2200 pF
Marked with Y1. Meets
IEC/EN60384-14.
FOWX2
UL(E120045)
FOWX2
UL(E145156)
FOWX2
UL(E165646)
FOWX2
UL(E236227)
FOWX2
UL(E199061)
Tested in the
equipment
-
Tested in the
equipment
-
FOWX2
UL(E107942)
FOWX2
UL(E128646)
Issue Date:
2015-10-29
Page 8 of 11
Report Reference #
Y-Capacitors (CY1,
CY2) – Alternate
SAMWHA
CAPACITOR
SD
Y-Capacitors (CY1,
CY2) – Alternate
Success Electronics
SE
Bridge diode (BD1)
Interchangeable
Interchangeable
Electrolytic Capacitor
(PC1)
FET (PQ1)
Interchangeable
Interchangeable
Interchangeable
Interchangeable
Switching IC (PU1)
Interchangeable
Interchangeable
Main Transformer (T1)
for 5V output
BridgePower &
Wendeng Jeil
JEC(B) (Part No.:
3025758001)
Main Transformer (T1)
for 9V output
BridgePower &
Wendeng Jeil
JEC(B) (Part No.:
3025758002)
Main Transformer (T1)
for 12V & 15V output
BridgePower &
Wendeng Jeil
JEC(B) (Part No.:
3025758003)
Main Transformer (T1)
for 18V output
BridgePower &
Wendeng Jeil
JEC(B) (Part No.:
3025758005)
Main Transformer (T1)
for 24V output
BridgePower &
Wendeng Jeil
JEC(B) (Part No.:
3025758006)
E300305-A111-UL
Rated 250V, Max. 2200 pF
Marked with Y1. Meets
IEC/EN60384-14.
Rated 250V, Max. 2200 pF
Marked with Y1. Meets
IEC/EN60384-14.
Min. 600V, Max. 0.4A.
FOWX2
UL(E97754)
FOWX2
UL(E114280)
Tested in the
equipment
Rated Min. 400 V, Max. 120uF, Tested in the
Min. 105°C.
equipment
650 V Min, 7.2A Max.
Tested in the
equipment
Max. 30V, 250mA.
Tested in the
equipment
Class B. Core: Ferrite, size 28 OBJY2
by 20 mm. Coils: TIW:
Furukawa, TEX-E, 130 deg C.
Bobbin: (QMFZ2), V-0, 130 deg
C.
Class B. Core: Ferrite, size 28 OBJY2
by 20 mm. Coils: TIW:
Furukawa, TEX-E, 130 deg C.
Bobbin: (QMFZ2), V-0, 130 deg
C.
Class B. Core: Ferrite, size 28 OBJY2
by 20 mm. Coils: TIW:
Furukawa, TEX-E, 130 deg C.
Bobbin: (QMFZ2), V-0, 130 deg
C.
Class B. Core: Ferrite, size 28 OBJY2
by 20 mm. Coils: TIW:
Furukawa, TEX-E, 130 deg C.
Bobbin: (QMFZ2), V-0, 130 deg
C.
Class B. Core: Ferrite, size 28 OBJY2
by 20 mm. Coils: TIW:
Furukawa, TEX-E, 130 deg C.
UL
UL
UL
UL
UL
Issue Date:
2015-10-29
Page 9 of 11
Report Reference #
Main Transformer (T1)
for 48V output
BridgePower &
Wendeng Jeil
JEC(B) (Part No.:
3025758007)
Insulator Sheet
(Between Inlet & PC1)
FORMEX, DIV OF
ILLINOIS TOOL
WORKS INC,
FORMERLY
COSMO
ELECTRONICS
CORP
FORMEX GK(a)(b)(f2)
Optical Isolator (U1) Alternate
Sharp Corp
PC123
Optical Isolator (U1) Alternate
AUK CORP
PC-17K or PC17K1C
Heatsink (HS1)
(Primary)
Interchangeable
Interchangeable
Heatsink (HS2)
(Secondary)
Interchangeable
Interchangeable
PWB
Bonding Glue
Interchangeable
Interchangeable
Interchangeable
Interchangeable
Optical Isolator (U1) Alternate
KP1010
E300305-A111-UL
Bobbin: (QMFZ2), V-0, 130 deg
C.
Class B. Core: Ferrite, size 28 OBJY2
by 20 mm. Coils: TIW:
Furukawa, TEX-E, 130 deg C.
Bobbin: (QMFZ2), V-0, 130 deg
C.
Overall Sized approx. 23 by 20 QMFZ2
mm. Rated V-0, 115°C,
min. 0.4 mm thick.
Double protection optical
isolator. Providing isolation
voltage 5000 Vac. External dcr
min. 8.0 mm.Interal Cl; 6.5mm,
CR; 6.5mm
Double protection optical
isolator. Providing isolation
voltage 5000 Vac. Internal
CL,CR; 6.4mm, External
CL,CR;8.0mm
Double protection optical
isolator. Providing isolation
voltage 5000 Vac. External dcr
min. 8.0 mm.Internal
CL,CR;7.0mm
Metal, overall sized approx. 27
by 20 mm, 2.0 mm thickness.
Wound by polyester film tape
OANZ2), Min. 130 deg C,
Metal, overall sized approx. 27
by 20 mm, 2.0 mm thickness.
Wound by polyester film tape
OANZ2), Min. 130 deg C,
Min. V-1, 130°C.
Min. V-2, min. 100 °C for
additional secureness of
UL
UL(E121855)
FPQU2
UL(E169586)
FPQU2
UL(E64380)
FPQU2
UL(E107486)
Tested in the
equipment
-
Tested in the
equipment
-
ZPMV2
QMFZ2
UL
UL
Issue Date:
2015-10-29
Page 10 of 11
Report Reference #
Output Cable
Interchangeable
Interchangeable
Output Cable
Alternate
Interchangeable
Interchangeable
Nameplate Label- For
I.T.E-optional
Interchangeable
Interchangeable
Tube
(Inside Inlet F.G)
Bonding conductor
(Class I)
Interchangeable
Interchangeable
Interchangeable
Interchangeable
E300305-A111-UL
internal conductor.
(For use of external
interconnection)
Style No. 2464 or 1777, min.
300 V, 80°C, 18 AWG, VW-1 or
FT-1. Max. 3.05 m long.
For use of external
interconnection, max 3.05 m
long, max. 300 V, 80 °C,
min.20 AWG, Marked with VW1 or FT-1.
Suitable for use on surface of
Polycarbonate (PC) with
max.80°C surface temperature.
Rated 600 V, 125°C, VW-1.
Mechanically clamped or
secured on PWB from
Appliance Inlet. Min 18 AWG,
VW-1 or FT-1, Green-andYellow Insulation.
AVLV2
UL
AVLV2 or ZJCZ
UL
PGDQ2, PGAA
UL
YDPU2
UL
AVLV2
UL
Issue Date:
2015-10-29
Page 11 of 11
Report Reference #
Enclosures
Type
Supplement Id
Description
Photographs
3-01
Direct type PCB top
Photographs
3-05
Classs I PCB Top
Diagrams
4-01
Pattern Diagram
Miscellaneous
7-02
Line Filter (LF1)
Miscellaneous
7-04
Transformer (T1)_3025758001
Miscellaneous
7-05
Transformer (T1)_3025758002
Miscellaneous
7-06
Transformer (T1)_3025758003
Miscellaneous
7-07
Transformer (T1)_3025758005
Miscellaneous
7-08
Transformer (T1)_3025758006
Miscellaneous
7-10
Transformer (T1)_3025758007
E300305-A111-UL