Issue Date: 2012-11-30 Page 1 of 15 Report Reference # E302267-A57-UL UL TEST REPORT AND PROCEDURE Standard: Certification Type: CCN: Product: Model: Rating: Applicant Name and Address: ANSI/AAMI ES60601-1 (2005 + C1:09 + A2:10)(Medical Electrical Equipment - Part 1: General Requirements for Basic Safety and Essential Performance) CAN/CSA-C22.2 No. 60601-1 (2008) (Medical Electrical Equipment Part 1: General Requirements for Basic Safety and Essential Performance) Component Recognition QQHM2, QQHM8 (Power Supplies, Medical and Dental) Medical Power Supply BP(a)020(b)(c)(e)(f) and (a)ENB1020(b)(c)(d)(e)(f) (a) can be A to Z for family related designs. (b) can be S for single output in model BP(a)020 series and A to Z for design revision changes in model (a)ENB1020 series. (c) can be 03 for 3.3Vdc, 05 for 5.0Vdc, 06 for 6.0Vdc, 07 for 7.5Vdc, 09 for 9.0Vdc, 12 for 12Vdc, 14 for 14Vdc, 15 for 15Vdc, 18 for 18Vdc, 24 for 24Vdc or 48 for 48Vdc output voltage. (d) can be 00 thru 99 for standards output cord options ("(d)" is not provided in model BP(a)020series). (e) can be F or N or Q or B or H or G or M or C for input plug type. See Enclosure-Photographs for each plug-type configuration F-Class I appliance inlet type: IEC60320-C14 Q-Class II appliance inlet type: IEC60320-C18 N-Class II appliance inlet type: IEC60320-C8 B or C-Class I & Class II direct-plug-in for North America, China, Japan and Argentina (Changeable Direct-plug-in type is only used for Class II) H-Class I & Class II direct-plug-in for Australia (AS/NZS 3112) G-Class I & Class II direct-plug-in for British (BS 1364) M-Class I & Class II direct-plug-in for European (CEE /16)] & Korea. (f) can be 00 thru 99 for customer options, not related safety concerns. Rated Input; 100-240 Vac, 50-60 Hz, 0.5 A(0.5 A-0.3 A) Rated Output; 3.3Vdc, 3.0A or 5Vdc, 3.0A or 5Vdc, 2.4A or 6Vdc, 2.5A or 7.5Vdc, 2.0A or 9Vdc, 2.0A or 9Vdc, 1.5A or 12Vdc, 1.5A or 14Vdc, 1.2A or 15Vdc, 1.2A or 18Vdc, 1.0A or 24Vdc, 0.75 or 48Vdc, 0.4A or 48Vdc, 0.35A. (Rated output voltage is designated in the model name designation system). BRIDGEPOWER CORP 964 GOSAEK-DONG GWONSEON-GU SUWON-SI GYEONGGI-DO 441-813 KOREA Copyright © 2012 Issue Date: 2012-11-30 Page 2 of 15 Report Reference # E302267-A57-UL This is to certify that representative samples of the products covered by this Test Report have been investigated in accordance with the above referenced Standards. The products have been found to comply with the requirements covering the category and the products are judged to be eligible for Follow-Up Service under the indicated Test Procedure. The manufacturer is authorized to use the UL Mark on such products which comply with this Test Report and any other applicable requirements of UL LLC ('UL') in accordance with the FollowUp Service Agreement. Only those products which properly bear the UL Mark are considered as being covered by UL's Follow-Up Service under the indicated Test Procedure. The applicant is authorized to reproduce the referenced Test Report provided it is reproduced in its entirety. UL authorizes the applicant to reproduce the latest pages of the referenced Test Report consisting of the first page of the Specific Technical Criteria through to the end of the Conditions of Acceptability. Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. Prepared by: DongGug Cho Reviewed by: DongYoul Kim Copyright © 2012 Issue Date: 2012-11-30 Page 3 of 15 Report Reference # E302267-A57-UL Supporting Documentation The following documents located at the beginning of this Procedure supplement the requirements of this Test Report: A. Authorization - The Authorization page may include additional Factory Identification Code markings. B. Generic Inspection Instructions i. Part AC details important information which may be applicable to products covered by this Procedure. Products described in this Test Report must comply with any applicable items listed unless otherwise stated in the body of this Test Report. ii. Part AE details any requirements which may be applicable to all products covered by this Procedure. Products described in this Test Report must comply with any applicable items listed unless otherwise stated in the body of each Test Report. iii. Part AF details the requirements for the UL Certification Mark which is not controlled by the technical standard used to investigate these products. Products are permitted to bear only the Certification Mark(s) corresponding to the countries for which it is certified, as indicated in each Test Report. Issue Date: 2012-11-30 Page 4 of 15 Report Reference # E302267-A57-UL Product Description Products are component power supplies intended to be used as part of Medical Electrical Equipment. This AC Input Power Supply provides 2MOPP isolation from Primary to Secondary/Enclosure(for Class II construction) and/or 1MOPP isolation from Primary to Earth (for Class I construction). It contains the mains transformer with UL Recognized Insulation System. This product is the AC-DC Adaptor of the switching type power supply, which electronic components are mounted on PWB and housed in plastic enclosure and provided with appliance inlet. Model Differences The BP-series is the base model. Model ENB1020-series is identical to the base model BP-series except for the model type designations. The below information is nomenclature detail for BP(a)020(b)(c)(e)(f) and (a)ENB1020(b)(c)(d)(e)(f): (a) can be A to Z for family related designs. (b) can be S for single output in model BP(a)020 series and A to Z for design revision changes in model (a)ENB1020 series. (c) can be 03, 05, 06, 07, 09, 12, 14, 15, 18, 24 or 48 for output voltage. (d) can be 00 thru 99 for standards output cord options ("(d)" is not provided in model BP(a)020series). (e) can be F or N or Q or B or H or G or M or C for input plug type. See Enclosure-Photographs for each plug-type configuration F-Class I appliance inlet type: IEC60320-C14 Q-Class II appliance inlet type: IEC60320-C18 N-Class II appliance inlet type: IEC60320-C8 B or C-Class I & Class II direct-plug-in for North America, China, Japan and Argentina (Changeable Directplug-in type is only used for Class II) H-Class I & Class II direct-plug-in for Australia (AS/NZS 3112) G-Class I & Class II direct-plug-in for British (BS 1364) M-Class I & Class II direct-plug-in for European (CEE /16)] & Korea. (f) can be 00 thru 99 for customer options, not related safety concerns. Technical Considerations Classification of installation and use : Hand-held or Portable Device type (component/sub-assembly/ equipment/ system) : Component power supply Intended use (Including type of patient, application location) : To supply regulated power. Mode of operation : Continuous Supply connection : Appliance inlet or direct Plug-in type Accessories and detachable parts included : None Other options include : None The product was investigated to the following additional standards:: ANSI/AAMI ES606011:2005/C1:2009 (includes National Differences for USA); CAN/CSA-C22.2 No. 60601-1:08 (includes National Differences for Canada), EN 60601-1:2006 Issue Date: 2012-11-30 Page 5 of 15 Report Reference # E302267-A57-UL The product was not investigated to the following standards or clauses:: Electromagnetic Compatibility (IEC 60601-1-2) Clause 14, Programmable Electronic Systems Biocompatibility (ISO 10993-1) Patient applied parts clauses: 4.6, 7.2.10, 8.3, 8.5.2, 8.5.5, 8.7.4.7-8.7.4.9, 8.9.1.15 Battery related clauses: 7.3.3, 15.4.3 Hand Control related clauses: 8.10.4 Oxygen related clauses: 11.2.2 Fluids related clauses: 11.6.2 - 11.6.4 Sterilization clause: 11.6.7 Motor related clauses: 13.2.13.3, 13.4 Heating Elements related clause: 13.2 Flammable Anesthetic Mixtures Protection: Annex G The degree of protection against harmful ingress of water is:: Ordinary The following accessories were investigated for use with the product:: No The mode of operation is:: Continuous The product is suitable for use in the presence of a flammable anesthetics mixture with air or oxygen or with nitrous oxide:: No Scope of Power Supply evaluation defers the following clauses to the be determined as part of the end product: Clause 7.5 (Safety Signs), Clause 7.9 (Accompanying Documents), Clause 9 (Mechanical Hazard), Clause 10 (Radiation), Clause 14 (PEMS), Clause 16 (ME Systems) These power supplies have been previously evaluated by UL to UL 60601-1: 1st ed., 2006-04-26 (includes National Differences for USA), CAN/CSA-C22.2 No. 601.1-M90 (R2005) (includes National Differences for Canada) under UL Test Report No. E302267-A29, and also by UL to UL 60950-1: 2nd ed., 2007 under UL Test Report No. E300305-A54. All tests conducted per 2nd ed. of UL 606011 and UL 60950-1 were considered representative of the corresponding tests required by 3rd ed. of AAMI ES 60601-1 and CAN/CSA C22.2 NO.60601-1 as stated under Summary of Testing above. Software is relied upon for meeting safety requirements related to mechanical, fire and shock: No The product is suitable for use in the presence of a flammable anaesthetics mixture with air or oxygen or with nitrous oxide: No The product has been considered for Pollution Degree 2 and Overvoltage Category II. Engineering Conditions of Acceptability For use only in or with complete equipment where the acceptability of the combination is determined by UL LLC. When installed in an end-product, consideration must be given to the following: Considerations to the applied parts requirement, to be conducted as end-product Consideration should be given to measuring the temperature on power electronic components and transformer windings when the power supply is installed in the end-use equipment. The end-use product shall ensure that the power supply is used within its ratings. Issue Date: 2012-11-30 Page 6 of 15 Report Reference # E302267-A57-UL The output circuits have not been evaluated for direct patient connection (Type B, BF or CF). The component shall be installed in compliance with the enclosure, mounting, marking, spacing, and separation requirements of the end use application. Power supply provides the following MOPP (means of patient protection): 2 MOPP based upon a rated voltage 198 Vrms and a working voltage 600 Vpk between Primary and Secondary/Enclosure and 1 MOPP based on a rated voltage 240 Vrms between Primary and Earth. Temperature, Leakage Current, Protective Earthing, Dielectric Voltage Withstand, and Marking Legibility tests should be considered as part of the end product evaluation. The product was submitted and tested for use at the manufacturer's recommended ambient temperature (Tmra) of 40 °C at Full Load. Magnetic devices (T1) employ a Class B (130°C) insulation system The PWB is rated 105°C minimum. The products were tested on a 15 A branch circuit. If used on a branch circuit greater than this, additional testing may be necessary. The end-product evaluation shall ensure that the requirements related to Accompanying Documents, Clause 7.9 are met. End product Risk Management Process to include consideration of requirements specific to the Power Supply. End product Risk Management Process to consider the need for different orientations of installation during testing. Power Supply tested for 48 hours Humidity Preconditioning. End product Risk Management Process to determine risk acceptability criteria. End product to determine the acceptability of risk in conjunction to insulation to resistance to heat, moisture, and dielectric strength. Temperature Test was conducted without Test Corner due to no heating elements incorporated in this power supply. End product to determine the acceptability of risk in conjunction to temperature testing without test corner as part of the power supply. End product to determine the acceptability of risk in conjunction to the results of Mechanical Testing conducted. Issue Date: 2012-11-30 Page 7 of 15 Report Reference # E302267-A57-UL Additional Information N/A Markings and instructions Clause Title Marking or Instruction Details Company identification Classified or Recognized company's name, Trade name, Trademark or File Model Model number Supply Connection Voltage range, ac/dc, phases if more than single phase Alternating current Direct current Supply Frequency Rated frequency range in hertz Class II equipment Power Input Amps, VA, or Watts Output Rated output voltage, power, frequency. Special Instructions to UL Representative N/A Production-Line Testing Requirements Test Exemptions - The following models are exempt from the indicated test Model Grounding Continuity Dielectric Voltage Withstand Patient Circuit Dielectric Voltage Withstand All models Not Except Not Except Except Solid-State Component Test Exemptions - The following solid-state components may be disconnected from the remainder of the circuitry during either Dielectric Voltage Withstand Test: Component N/A Sample and Test Specifics for Follow-Up Tests at UL The following tests shall be conducted in accordance with the Generic Inspection Instructions Plastic Enclosure or Part N/A Test Sample(s) Test Specifics Issue Date: 2012-11-30 Page 8 of 15 Report Reference # E302267-A57-UL TABLE: List of Critical Components Object/part or Description Manufacturer/ trademark type/model technical data CCN Marks of Conformity Enclosure Cheil Industries HN-1064(+) Overall Sized approx 84.5 by 46.5 by 32mm & 113 by 48 by 33.5mm.Min 2.0 mm thickness, V-0. A Recognized Fabricated Part by 'QMMY2' Manufacturer. Min.10A, 250V Min.2.5A, 250V Rated 250V, 3.15A. Marked as "250V, T3.15AL" on PWB. Rated 250V, 3.15A. Marked as "250V, T3.15AL" on PWB. Rated 250V, 3.15A. Marked as "250V, T3.15AL" on PWB. Rated Min. 470 V, (line-to-line), Overall dimension 14 mm. Rated Min. 470 V, (line-to-line), Overall dimension 14 mm. NTC, 5ohm at 25°C. QMFZ2 UL AXUT2 AXUT2 JDYX2 UL UL UL JDYX2 UL JDYX2 UL VZCA2/8 UL/cUL VZCA2 UL Tested in the equipment FOWX2 - FOWX2, FOWX8 UL/cUL FOWX2, FOWX8 UL/cUL FOWX2, FOWX8 UL/cUL Tested in the equipment Tested in the equipment Tested in the - Appliance Inlet-Class I Appliance Inlet-Class II Fuse (F1, F2) Rong Feng Industrial Rong Feng Industrial Wickmann-Werke GMBH Fuse (F1, F2) - Alternate Save Fusetech Inc. SS-5 Fuse (F1, F2) - Alternate Hollyland 5ET Varistor (ZNR4) (Optional) Varistor (ZNR4) (Optional) - Alternate Thermister (TH1) Success Electronics SVR14D471K AMOTECH CO LTD INR14D471 Various Various Carli MPX Pilkor Sunil PCX2 335M or PCX2 337 436D Tenta MEX Various Various 250V, max.0.1 uF. Marked with X1 or X2. Meets IEC384-14. 250V, max.0.1 uF. Marked with X1 or X2. Meets IEC384-14. 250V, max.0.1 uF. Marked with X1 or X2. Meets IEC384-14. 250V, max.0.1 uF. Marked with X1 or X2. Meets IEC384-14. Min.1/8W, 510Kohm. Various Various Min.1/8W, 1.5Mohm. Bridgepower Corp or 3025517 Core: Ferrite, Coils: Polyurethane wire min130°C. X-capacitor (CX1) (Line to Line) X-capacitor (CX1) (Line to Line) - Alternate X-capacitor (CX1) (Line to Line) - Alternate X-capacitor (CX1) (Line to Line) - Alternate Discharge resistor (PR1, PR2) Discharge resistor (PR1, PR2)-24V & 48V only Line Filter (LF1) SS-120 RF-180 392 UL - Issue Date: 2012-11-30 Object/part or Description Page 9 of 15 Manufacturer/ trademark Report Reference # type/model Wendeng Jeil Electronics Co Ltd Y-Capacitors (CY1) Success Electronics SE Y-Capacitors (CY1) Alternate Y-Capacitors (CY1) Alternate Y-Capacitors (CY1) Alternate Y-Capacitors (CY1) Alternate Y-Capacitors (CY1) Alternate TDK Corp. CD Dongil DA Netron tech AA Samwha Capacitor SD KUNSHAN TONGFENG ELECTRONICS CO LTD Success Electronics CT7 SE or SB TDK Corp. CD or CS Dongil DA or DS Netron tech AA or AD Samwha Capacitor SD, SC KUNSHAN TONGFENG ELECTRONICS CO LTD Various CT7 Y-Capacitors (CY1, CY2) - Alternate Y-Capacitors (CY1, CY2) - Alternate Y-Capacitors (CY1, CY2) - Alternate Y-Capacitors (CY1, CY2) - Alternate Y-Capacitors (CY1, CY2) - Alternate Y-Capacitors (CY1, CY2) - Alternate Bridge Resistor (R3) Bridge Resistor (R3, R4) Various - Alternate E302267-A57-UL technical data CCN Bobbin: (QMFZ2), Hexian Specialty Chemicals, type PM9820@, V-0, 150°C. See Enclosure for details. 250V, max.1000 pF. Marked with Y1. Meets IEC384-14. 250V, max.1000 pF. Marked with Y1. Meets IEC384-14. 250V, max.1000 pF. Marked with Y1. Meets IEC384-14. 250V, max.1000 pF. Marked with Y1. Meets IEC384-14. 250V, max.1000 pF. Marked with Y1. Meets IEC384-14. 250V, max.1000 pF. Marked with Y1. Meets IEC384-14. equipment Marks of Conformity FOWX2 UL FOWX2 UL FOWX2/8 UL FOWX2 UL FOWX2 UL FOWX2 UL 250V, max.1000 pF. Marked with Y1 or Y2. Meets IEC384-14. 250V, max.1000 pF. Marked with Y1 or Y2. Meets IEC384-14. 250V, max.1000 pF. Marked with Y1 or Y2. Meets IEC384-14. 250V, max.1000 pF. Marked with Y1 or Y2. Meets IEC384-14. 250V, max.1000 pF. Marked with Y1 or Y2. Meets IEC384-14. 250V, max.1000 pF. Marked with Y1 or Y2. Meets IEC384-14. FOWX2 UL FOWX2 UL FOWX2 UL FOWX2 UL FOWX2 UL FOWX2 UL Various 1/4W, 10MOhm - Various 1/4W, 4.7MOhm Tested in the equipment Tested in the equipment - Issue Date: 2012-11-30 Page 10 of 15 Report Reference # E302267-A57-UL Object/part or Description Manufacturer/ trademark type/model technical data CCN Marks of Conformity Bridge diode (BD1) Various Various Min 600V, max. 0.8A. - Electrolytic Capacitor (C1, C2) Switching IC (U1) Various Various Rated 400 V or 450V, max. 22 uF, min. 105°C. Various Various Max30V, Max4mA. FET (Q1) Various Various Max 650 V, 4.2A. Secured to HS1 by a screw. Main Transformer (T1) for 3.3V output Bridgepower Corp or Wendeng Jeil Electronics Co Ltd JEC(B) (Part No.: 3025685001) Class B: R/C (OBJY2), Class 130(B) Insulation System, BridgePower Corp, Designated JEC(B) Tested in the equipment Tested in the equipment Tested in the equipment Tested in the equipment - - UL - UL UL Winding: R/C (OBJT2), Triple Insulated Wire, 130 deg C, Furukawa Electric, Cat. No: TEX-E Core: Ferrite, size 25 by 19mm. Coils: Polyurethane wire Min. 130 deg C. Main Transformer (T1) for 5 V & 6 Voutput Bridgepower Corp or Wendeng Jeil Electronics Co Ltd JEC(B) (Part No.: 3025685002 or 3025685002S) Bobbin: (QMFZ2), V-0, 130 deg C. Class B: R/C (OBJY2), Class 130(B) Insulation System, BridgePower Corp, Designated JEC(B) Winding: R/C (OBJT2), Triple Insulated Wire, 130 deg C, Furukawa Electric, Cat. No: TEX-E Core: Ferrite, size 25 by 19mm. Coils: Polyurethane wire Min. 130 deg C. Main Transformer (T1) for 7.5 V & 9 Voutput Bridgepower Corp or Wendeng Jeil Electronics Co Ltd JEC(B) (Part No.: 3025685003) Bobbin: (QMFZ2), V-0, 130 deg C. Class B: R/C (OBJY2), Class 130(B) Insulation System, BridgePower Corp, Designated JEC(B) Winding: R/C (OBJT2), Triple Insulated Wire, 130 deg C, Furukawa Electric, Cat. No: TEX-E Core: Ferrite, size 25 by 19mm. Coils: Issue Date: 2012-11-30 Object/part or Description Page 11 of 15 Manufacturer/ trademark Report Reference # type/model E302267-A57-UL technical data CCN Marks of Conformity - UL - UL - UL Polyurethane wire Min. 130 deg C. Main Transformer (T1) for 12 Voutput Bridgepower Corp or Wendeng Jeil Electronics Co Ltd JEC(B) (Part No.: 3025685004) Bobbin: (QMFZ2), V-0, 130 deg C. Class B: R/C (OBJY2), Class 130(B) Insulation System, BridgePower Corp, Designated JEC(B) Winding: R/C (OBJT2), Polyurethanewire Min. 130deg C.Triple Insulated Wire, 130 deg C, Furukawa Electric, Cat. No: TEX-E Core: Ferrite, size 25 by 19mm. Coils: Polyurethane wire Min. 130 deg C. Main Transformer (T1) for 14 V & 15 V output Bridgepower Corp or Wendeng Jeil Electronics Co Ltd JEC(B) (Part No.: 3025685005) Bobbin: (QMFZ2), V-0, 130 deg C. Class B: R/C (OBJY2), Class 130(B) Insulation System, BridgePower Corp, Designated JEC(B) Winding: R/C (OBJT2), Polyurethanewire Min. 130deg C.Triple Insulated Wire, 130 deg C, Furukawa Electric, Cat. No: TEX-E Core: Ferrite, size 25 by 19mm. Coils: Polyurethane wire Min. 130 deg C. Main Transformer (T1) for 18 V output Bridgepower Corp or Wendeng Jeil Electronics Co Ltd JEC(B) (Part No.: 3025685006) Bobbin: (QMFZ2), V-0, 130 deg C. Class B: R/C (OBJY2), Class 130(B) Insulation System, BridgePower Corp, Designated JEC(B) Winding: R/C (OBJT2), Polyurethanewire Min. 130deg C.Triple Insulated Wire, 130 deg C, Furukawa Electric, Cat. No: TEX-E Core: Ferrite, size 25 by 19mm. Coils: Polyurethane wire Min. 130 deg C. Issue Date: 2012-11-30 Page 12 of 15 Report Reference # E302267-A57-UL Object/part or Description Manufacturer/ trademark type/model technical data CCN Marks of Conformity Main Transformer (T1) for 24 V output Bridgepower Corp or Wendeng Jeil Electronics Co Ltd JEC(B) (Part No.: 3025685007) Bobbin: (QMFZ2), V-0, 130 deg C. Class B: R/C (OBJY2), Class 130(B) Insulation System, BridgePower Corp, Designated JEC(B) - UL - UL FPQU2/8 UL/cUL FPQU2/8 UL/cUL FPQU2 UL FPQU2/8 UL/cUL Tested in the - Winding: R/C (OBJT2), Polyurethanewire Min. 130deg C.Triple Insulated Wire, 130 deg C, Furukawa Electric, Cat. No: TEX-E Core: Ferrite, size 25 by 19mm. Coils: Polyurethane wire Min. 130 deg C. Main Transformer (T1) for 48 V output Bridgepower Corp or Wendeng Jeil Electronics Co Ltd JEC(B) (Part No.: 3025685008) Bobbin: (QMFZ2), V-0, 130 deg C. Class B: R/C (OBJY2), Class 130(B) Insulation System, BridgePower Corp, Designated JEC(B) Winding: R/C (OBJT2), Polyurethanewire Min. 130deg C.Triple Insulated Wire, 130 deg C, Furukawa Electric, Cat. No: TEX-E Core: Ferrite, size 25 by 19mm. Coils: Polyurethane wire Min. 130 deg C. Optical Isolator (U2) Vishay Semiconductor TCET1103(G) Optical Isolator (U2)Alternate COSMO ELECTRONICS CORP Sharp Corp KP1010 Optical Isolator (U2)Alternate Optical Isolator (U2)Alternate Heatsink(HS1)(For Q1) PC123 KODENSHI KOREA PC-17K PC-17K1C Various Various Bobbin: (QMFZ2), V-0, 130 deg C. Double protection optical isolator. Providing isolation voltage 5000 Vac. External dcr min. 8.0 mm. Double protection optical isolator. Providing isolation voltage 5000 Vac. External dcr min. 8.0 mm. Double protection optical isolator. Providing isolation voltage 5000 Vac. Double protection optical isolator. Providing isolation voltage 5000 Vac. External dcr min. 8.0 mm. Overall Sized Min. ø 18 Issue Date: 2012-11-30 Object/part or Description Heatsink(HS2)(For D3) Page 13 of 15 Manufacturer/ trademark type/model Various Various Insulation Various Sheet(Between T1 & U2) Various PWB Output Cable Various Various Various Various Bonding Glue Various Various Nameplate Label BETHEL BG-1000 Report Reference # E302267-A57-UL technical data CCN by 20 mm , Min. 1.5 mm thick Overall Sized Min. ø 20 by 21 mm , Min. 1.5 mm thick Overall Sized Min. ø 31 by 20 mm , Min. 0.4 mm thick Min. V-1, 130°C. SPT1. 300 V, 80°C, min 20 AWG, VW-1, FT-1. Max. 3.05 m long Min. V-2, min. 100 °C for additional secureness of internal conductor. Suitable for use on surface of Polycarbonate (PC) with max.80°C surface temperature. equipment Marks of Conformity Tested in the equipment - QMFZ2 UL ZPMV2 AVLV2 UL UL QMFZ2 UL PGDQ2, PGAA UL Issue Date: 2012-11-30 Page 14 of 15 Report Reference # E302267-A57-UL Enclosures Type Supplement Id Description Collateral Particular Photographs 3-04 External View (Changeable direct plug-in type for Australia) Photographs 3-05 External View of B Type For China (See the nomenclature of model designation) Photographs 3-06 External View of B Type for North America - Class II (See the nomenclature of model designation) Photographs 3-07 External View of H Type - Class II (See the nomenclature of model designation) Photographs 3-08 External View of G Type - Class I (See the nomenclature of model designation) Photographs 3-09 External View of M Type For Europe - Class II(See the nomenclature of model designation) Photographs 3-10 External View of N Type 1 - Class II(See the nomenclature of model designation) Photographs 3-11 External View of Q Type - Class II (See the nomenclature of model designation) Photographs 3-12 External View (Changeable direct plug-in type for UK) Photographs 3-13 External View of F Type - Class I (See the nomenclature of model designation) Photographs 3-14 Internal View of F Type - Class I (See the nomenclature of model designation) Photographs 3-15 Internal View of F Type - Class I (See the nomenclature of model designation) Photographs 3-16 External View of POF B type Photographs 3-17 Internal top view of POE A type Photographs 3-18 Internal bottom view of POE A type Photographs 3-19 Internal top view of POE B type Photographs 3-20 Internal top bottom of POE B type Schematics + PWB 5-03 Circuit Diagram Schematics + PWB 5-04 Pattern Diagram Miscellaneous 7-01 Marking Plate_1 Miscellaneous 7-02 Marking Plate_2 Diagrams Manuals