File E136791 Project 07NK01111 November 9, 2007 REPORT ON POWER SUPPLIES, INFORMATION TECHNOLOGY EQUIPMENT INCLUDING ELECTRICAL BUSINESS EQUIPMENT SL Power Electronics Corp. Ventura, CA Copyright © 2007 Underwriters Laboratories, Inc. Underwriters Laboratories Inc. authorizes the above named company to reproduce this Report provided it is reproduced in its entirety. File E136791 Vol. 1 Sec. 73 and Report Page 1 Issued: 2007-11-09 DESCRIPTION PRODUCT COVERED: USL, CNL - PoE Injector, Model PW182, followed by additional suffixes as noted under the Part Number Designation. GENERAL CHARACTER AND USE: This product is a Power over Ethernet (PoE) Injector incorporating semiconductor components in the primary circuit and an isolating transformer. The input is supplied from an appliance inlet, and the unit is provided with RJ-45 connectors for connection to an ethernet network that does not connect to outside plant and to transfer data and power to another device. The outputs are considered LPS, SELV, and non-energy hazardous. ELECTRICAL RATINGS: Model PW182-XA-48-XX-X-XX, PW182-XC-48-XX-X-XX PW182-XB-48-XX-X-XX, PW182-XD-48-XX-X-XX Input, 50-60 Hz. V A 100-240 0.6 Output, d.c. V A 48 0.4 100-240 48 0.6 0.35 NOTE: The marked output voltage may be less than the rated output voltage per the table, provided that the output current remains the same or less as shown in the table. File E136791 Vol. 1 Sec. 73 and Report Page 2 Issued: 2007-11-09 PART NUMBER DESIGNATION: PW182 1 X 2 X 3 XX 4 XX 5 X 6 1. Model Number for family related designs. 2. Manufacturing Location: A-Z. 3. Design Revision Changes: A, C = 0.35 A. B, D = 0.4 A. 4. Tabulated output voltage as noted in Electrical Ratings, above. 5. Number Options: 00-99. 6. Input Options: F = Class I, C14 Appliance inlet. N = Class II, C8 Appliance inlet. Q = Class II, C18 Appliance inlet. 7. Number Options: 00-99. XX 7 File E136791 Vol. 1 Sec. 73 and Report Page 3 Issued: 2007-11-09 ENGINEERING CONSIDERATIONS (NOT FOR FIELD REPRESENTATIVE'S USE): Special Considerations - The following items are considerations that were used when evaluating this product. USL/CNL indicates investigation to the U.S. and Canadian (Bi-National) Standard for Safety of Information Technology Equipment – Part 1: General Requirements, CAN/CSA-C22.2 No. 60950-1-03,UL 60950-1, First Edition, dated April 1, 2003, with Revisions through and including July 7, 2006. The equipment has been evaluated for use in a Manufacturer's Recommended ambient (Tma) of 25°C. The equipment is considered movable, Class I (earthed) or Class II (double insulated), pluggable Type A, uses a detachable power cord, intended for use on a TN power system. This product has been investigated for pollution degree 2 applications. It is considered for IPX0 ordinary protection against the ingress of water. Disconnect Device - The following component is considered the equipment disconnect device: Appliance Inlet. Limited Power Source: All outputs are LPS. The RJ-45 connectors were not evaluated for connection to outside plant and should only be connected to ethernet networks and devices that do not directly exit the building. MODEL DIFFERENCES Models are identical to each other except for differences in secondary circuitry, pin out on ethernet connectors, output ratings (as noted above) and aesthetics.