US/14949/UL Page 1 of 2 Power Supply SL POWER ELECTRONICS CORP 6050 KING DR BLDG A VENTURA CA 93003, USA SL POWER ELECTRONICS CORP 6050 KING DR BLDG A VENTURA CA 93003, USA SL POWER ELECTRONICS XIANGHE ANPING ECONOMIC & TECH DEVELOPING ZONE XIANGHE HEBEI 065402, CHINA For ratings information see second page of this certificate. Not applicable MENT1220VWXYZ, where V represents the generational differences which may be any letter from A thru Z; W represents the output voltage which may be any number from 12, 15, 18 or any number from 24 thru 48; X represents the output cable and connector which may be any two alphanumeric digits; Y represents the AC inlet connector which may be the letter F, N, or Q; F for C14 type AC inlet (Class I), N for C8 type AC inlet (Class II), Q for C18 type AC inlet (Class II); and Z represents non-safety related customer options which may be any two alphanumeric digits. The CB Test Report comprises 6 enclosures. IEC 60950-1 (2001) First Edition, Additionally evaluated to EN60950-1 (2001) with Am. 11 (2004) to include Group and National Differences for European countries; other National Differences also specified in the CB Test Report. E136791-A19-CB-1 Issued: 2010 April 19 Jolanta M. Wroblewska Page 2 of 2 US/14949/UL Input: 100-240 V~, 50-60 Hz, 2.5-1.2 A Output: 48 V maximum, 15 A maximum, 220 W optional, or see below for standard output models. MENT1220V12XYZ: 12 V dc/15 A MENT1220V15XYZ: 15 V dc/13 A MENT1220V18XYZ: 18 V dc/11.7 A MENT1220V24XYZ: 24 V dc/9.2 A MENT1220V28XYZ: 28 V dc/7.9 A MENT1220V32XYZ: 32 V dc/6.9 A MENT1220V48XYZ: 48 V dc/4.6 A Issued: 2010 April 19 Jolanta M. Wroblewska Issue Date: 2010-04-19 Page 1 of 2 Report Reference # E136791-A19-UL-1 COVER PAGE FOR TEST REPORT Product Category: Product Category CCN: Test Procedure: Product: Model/Type Reference: Rating(s): Power Supplies for Information Technology Equipment Including Electrical Business Equipment QQGQ2, QQGQ8 Component Recognition Power Supply MENT1220VWXYZ, where V represents the generational differences which may be any letter from A thru Z; W represents the output voltage which may be any number from 12, 15, 18 or any number from 24 thru 48; X represents the output cable and connector which may be any two alphanumeric digits; Y represents the AC inlet connector which may be the letter F, N, or Q; F for C14 type AC inlet (Class I), N for C8 type AC inlet (Class II), Q for C18 type AC inlet (Class II); and Z represents non-safety related customer options which may be any two alphanumeric digits. Input: 100-240 V~, 50-60 Hz, 2.5-1.2 A Output: Standards: Applicant Name and Address: 48 V maximum, 15 A maximum, 220 W optional, or see below for standard output models. MENT1220V12XYZ: 12 V dc/15 A MENT1220V15XYZ: 15 V dc/13 A MENT1220V18XYZ: 18 V dc/11.7 A MENT1220V24XYZ: 24 V dc/9.2 A MENT1220V28XYZ: 28 V dc/7.9 A MENT1220V32XYZ: 32 V dc/6.9 A MENT1220V48XYZ: 48 V dc/4.6 A UL 60950-1, 1st Edition, 2007-10-31 (Information Technology Equipment Safety - Part 1: General Requirements) CSA C22.2 No. 60950-1-03, 1st Edition, 2006-07 (Information Technology Equipment - Safety - Part 1: General Requirements) SL POWER ELECTRONICS CORP BLDG A 6050 KING DR VENTURA CA 93003 UNITED STATES This Report includes the following parts, in addition to this cover page: 1. Specific Inspection Criteria 2. Specific Technical Criteria 3. Clause Verdicts 4. Critical Components 5. Test Results 6. National Differences 7. Enclosures Copyright © 2010 Issue Date: 2010-04-19 Page 2 of 2 Report Reference # E136791-A19-UL-1 This is to certify that representative samples of the products covered by this Test Report have been investigated in accordance with the above referenced Standards. The products have been found to comply with the requirements covering the category and the products are judged to be eligible for Follow-Up Service under the indicated Test Procedure. The manufacturer is authorized to use the UL Mark on such products which comply with this Test Report and any other applicable requirements of Underwriters Laboratories Inc. ('UL') in accordance with the Follow-Up Service Agreement. Only those products which properly bear the UL Mark are considered as being covered by UL's Follow-Up Service under the indicated Test Procedure. The applicant is authorized to reproduce the referenced Test Report provided it is reproduced in its entirety. UL authorizes the applicant to reproduce the latest pages of the referenced Test Report consisting of the first page of the Specific Technical Criteria through to the end of the Conditions of Acceptability. Any information and documentation involving UL Mark services are provided on behalf of Underwriters Laboratories Inc. (UL) or any authorized licensee of UL. Test Report By: Reviewed By: Tom Scheuffele Senior Project Engineer Underwriters Laboratories Inc. David Feusier Staff Engineer Underwriters Laboratories Inc. Copyright © 2010 Issue Date: 2010-04-19 Page 3 of 57 Report Reference # E136791-A19-UL-1 SPECIFIC TECHNICAL CRITERIA UL 60950-1, First Edition Information technology equipment - SafetyPart 1: General Requirements Report Reference No ........................: E136791-A19-UL-1 Compiled by .....................................: Tom Scheuffele Reviewed by ....................................: David Feusier Date of issue ....................................: 2010-04-19 Standards .........................................: UL 60950-1, 1st Edition, 2007-10-31 (Information Technology Equipment - Safety - Part 1: General Requirements) CSA C22.2 No. 60950-1-03, 1st Edition, 2006-07 (Information Technology Equipment - Safety - Part 1: General Requirements) Test procedure .................................: Component Recognition Non-standard test method ...............: N/A Test item description .......................: Power Supply Trademark ........................................: None Model and/or type reference ............: MENT1220VWXYZ, where V represents the generational differences which may be any letter from A thru Z; W represents the output voltage which may be any number from 12, 15, 18 or any number from 24 thru 48; X represents the output cable and connector which may be any two alphanumeric digits; Y represents the AC inlet connector which may be the letter F, N, or Q; F for C14 type AC inlet (Class I), N for C8 type AC inlet (Class II), Q for C18 type AC inlet (Class II); and Z represents non-safety related customer options which may be any two alphanumeric digits. Rating(s) ...........................................: Input: 100-240 V~, 50-60 Hz, 2.5-1.2 A Output: 48 V maximum, 15 A maximum, 220 W optional, or see below for standard output models. MENT1220V12XYZ: 12 V dc/15 A MENT1220V15XYZ: 15 V dc/13 A MENT1220V18XYZ: 18 V dc/11.7 A MENT1220V24XYZ: 24 V dc/9.2 A MENT1220V28XYZ: 28 V dc/7.9 A MENT1220V32XYZ: 32 V dc/6.9 A MENT1220V48XYZ: 48 V dc/4.6 A Underwriters Laboratories Inc. Issue Date: 2010-04-19 Page 4 of 57 Report Reference # E136791-A19-UL-1 Particulars: test item vs. test requirements Equipment mobility .................................................... : transportable Operating condition ................................................... : continuous Mains supply tolerance (%) ....................................... : +6%, -10% Tested for IT power systems .................................... : Yes IT testing, phase-phase voltage (V) .......................... : 230 Class of equipment ................................................... : Class I (earthed) and Class II (double insulated) Mass of equipment (kg) ............................................ : 1.3 Protection against ingress of water ........................... : IP X1 Possible test case verdicts: - test case does not apply to the test object ............. : N / A - test object does meet the requirement ................... : Pass - test object does not meet the requirement ............. : Fail (acceptable only if a corresponding, less stringent national requirement is "Pass") General remarks: - "(see Enclosure #)" refers to additional information appended to the Test Report - "(see appended table)" refers to a table appended to the Test Report - Throughout the Test Report a point is used as the decimal separator Underwriters Laboratories Inc. Issue Date: 2010-04-19 Page 5 of 57 Report Reference # E136791-A19-UL-1 GENERAL PRODUCT INFORMATION: CA1.0 Report Summary CA1.1 N/A CB1.0 Product Description CB1.1 Switching Power Supply CC1.0 Model Differences CC1.1 The models differ in output ratings which requires different turns and gage in transformers T301 & T302 and secondary circuitry component values to accommodate the rated output. Other differences are output cable/connector, AC inlet options for Class I and Class II and non-safety related customer options. In addition, the output + or - may be connected to ground/heatsink for Model MENT1220VWXFZ. CD1.0 Additional Information CD1.1 N/A CE1.0 Technical Considerations CE1.3 The means of connection to the mains supply is: Detachable power cord CE1.4 The product is intended for use on the following power systems: IT, TN and TT CE1.5 The equipment disconnect device is considered to be: Appliance inlet CE1.7 The product was investigated to the following additional standards: IEC 60950-1:2001, First Edition inclusive of CENELEC Common Modifications. EN 60950-1:2001 + A11:2004 (which includes all European national differences, including those specified in this test report). IEC 60529, (2001) Edition 2.1. CE1.12 The following were investigated as part of the protective earthing/bonding: Appliance inlet C14. CE1.14 The following are available from the Applicant upon request: Installation (Safety) Instructions / Manual, Schematic Diagrams CF1.0 Engineering Conditions of Acceptability CF1.1 For use only in or with complete equipment where the acceptability of the combination is determined by Underwriters Laboratories Inc. When installed in an end-product, consideration must be given to the following: CF1.5 The following secondary output circuits are SELV: All CF1.6 The following secondary output circuits are at hazardous energy levels: All CF1.12 The maximum investigated branch circuit rating is: 20 A CF1.13 The investigated Pollution Degree is: 2 CF1.18 The following magnetic devices (e.g. transformers or inductor) are provided with an OBJY2 Underwriters Laboratories Inc. Issue Date: 2010-04-19 Page 6 of 57 Report Reference # E136791-A19-UL-1 insulation system with the indicated rating greater than Class A (105°C): T301 and T302 (Class B) CF1.20 The following components require special consideration during end-product Thermal (Heating) tests due to the indicated maximum temperature measurements during component-level testing: 40 °C Underwriters Laboratories Inc. DEMKO CERTIFICATE Certificate No. Page Date of Issue 150523-01 1/3 2010-04-23 Certificate Holder SL POWER ELECTRONICS CORP BLDG A, 6050 KING DR VENTURA CA 93003, USA Manufacturer SL POWER ELECTRONICS CORP BLDG A, 6050 KING DR VENTURA CA 93003, USA Production site Certified Product Model Trademark Rated Voltage / Frequency Rated Current / Power Insulation Class Degree of protection (IP) Tested acc. to Test Report No. Additional Expire date Certification Manager Jan-Erik Storgaard Certification Body SL POWER ELECTRONICS XIANGHE ANPING ECONOMIC & TECH DEVELOPING ZONE XIANGHE, HEBEI 065402 CHINA Power Supply MENT1220VWXYZ None 100-240 V~, 50-60 Hz 2.5-1.2 A X1 EN 60950-1:2001 + A11:2004 E136791-A19-CB-1 issue date 2010-04-19 See appendix 2010-12-01 The product and production sites listed on the certificate comply with the D-mark requirements and the UL Global Service Agreement, with reference to Terms and Conditions for the D mark. The Owner of the certificate is entitled to use the δ or for cables <DEMKO>, for the products listed on the certificate and manufactured at the production sites listed. UL has to be informed in writing about any changes to the product or production site in accordance with the Term and Conditions of the D mark. The validity of the certificate is shortened if the EU legislation require re-testing and re-certification due to new standards or amendments coming into force before the expiry date. UL International Demko A/S, Lyskaer 8, P.O. Box 514, DK-2730 Herlev, Denmark, Tel. +45 44 85 65 65, [email protected] www.ul-europe.com Appendix DEMKO CERTIFICATE Certificate No. Page Date of Issue 150523-01 2/3 2010-04-23 Additional : Type kye : where V represents the generational differences which may be any letter from A thru Z; W represents the output voltage which may be any number from 12, 15, 18 or any number from 24 thru 48; X represents the output cable and connector which may be any two alphanumeric digits; Y represents the AC inlet connector which may be the letter F, N, or Q; F for C14 type AC inlet (Class I), N for C8 type AC inlet (Class II), Q for C18 type AC inlet (Class II); and Z represents non-safety related customer options which may be any two alphanumeric digits. Output: 48 V maximum, 15 A maximum, 220 W optional, or see below for standard output models. MENT1220V12XYZ: 12 V dc/15 A MENT1220V15XYZ: 15 V dc/13 A MENT1220V18XYZ: 18 V dc/11.7 A MENT1220V24XYZ: 24 V dc/9.2 A MENT1220V28XYZ: 28 V dc/7.9 A MENT1220V32XYZ: 32 V dc/6.9 A MENT1220V48XYZ: 48 V dc/4.6 A The certificate has been issued on the basis of CB certificate (CB Test certificate) No. US/14949/UL, issued by Underwriters Laboratories Inc, dated 2010-04-19 Certification Body UL International Demko A/S, Lyskaer 8, P.O. Box 514, DK-2730 Herlev, Denmark, Tel. +45 44 85 65 65, [email protected] www.ul-europe.com Appendix DEMKO Certificate Certification Mark Certificate No. Page Date of Issue D-mark Certification Body UL International Demko A/S, Lyskaer 8, P.O. Box 514, DK-2730 Herlev, Denmark, Tel. +45 44 85 65 65, [email protected] www.ul-europe.com 150523-01 3/3 2010-04-23