US/14949/UL

US/14949/UL
Page 1 of 2
Power Supply
SL POWER ELECTRONICS CORP
6050 KING DR BLDG A
VENTURA CA 93003, USA
SL POWER ELECTRONICS CORP
6050 KING DR BLDG A
VENTURA CA 93003, USA
SL POWER ELECTRONICS XIANGHE
ANPING ECONOMIC & TECH DEVELOPING ZONE
XIANGHE HEBEI 065402, CHINA
For ratings information see second page of this certificate.
Not applicable
MENT1220VWXYZ, where V represents the generational differences which may be any letter from A
thru Z; W represents the output voltage which may be any number from 12, 15, 18 or any number from
24 thru 48; X represents the output cable and connector which may be any two alphanumeric digits; Y
represents the AC inlet connector which may be the letter F, N, or Q; F for C14 type AC inlet (Class I),
N for C8 type AC inlet (Class II), Q for C18 type AC inlet (Class II); and Z represents non-safety related
customer options which may be any two alphanumeric digits.
The CB Test Report comprises 6 enclosures.
IEC 60950-1 (2001) First Edition,
Additionally evaluated to EN60950-1 (2001) with Am. 11 (2004) to include Group
and National Differences for European countries; other National Differences also
specified in the CB Test Report.
E136791-A19-CB-1
Issued: 2010 April 19
Jolanta M. Wroblewska
Page 2 of 2
US/14949/UL
Input:
100-240 V~, 50-60 Hz, 2.5-1.2 A
Output:
48 V maximum,
15 A maximum,
220 W optional,
or see below for standard output models.
MENT1220V12XYZ: 12 V dc/15 A
MENT1220V15XYZ: 15 V dc/13 A
MENT1220V18XYZ: 18 V dc/11.7 A
MENT1220V24XYZ: 24 V dc/9.2 A
MENT1220V28XYZ: 28 V dc/7.9 A
MENT1220V32XYZ: 32 V dc/6.9 A
MENT1220V48XYZ: 48 V dc/4.6 A
Issued: 2010 April 19
Jolanta M. Wroblewska
Issue Date:
2010-04-19
Page 1 of 2
Report Reference #
E136791-A19-UL-1
COVER PAGE FOR TEST REPORT
Product Category:
Product Category CCN:
Test Procedure:
Product:
Model/Type Reference:
Rating(s):
Power Supplies for Information Technology Equipment Including Electrical
Business Equipment
QQGQ2, QQGQ8
Component Recognition
Power Supply
MENT1220VWXYZ, where V represents the generational differences which may
be any letter from A thru Z; W represents the output voltage which may be any
number from 12, 15, 18 or any number from 24 thru 48; X represents the output
cable and connector which may be any two alphanumeric digits; Y represents the
AC inlet connector which may be the letter F, N, or Q; F for C14 type AC inlet
(Class I), N for C8 type AC inlet (Class II), Q for C18 type AC inlet (Class II); and
Z represents non-safety related customer options which may be any two
alphanumeric digits.
Input: 100-240 V~, 50-60 Hz, 2.5-1.2 A
Output:
Standards:
Applicant Name and
Address:
48 V maximum,
15 A maximum,
220 W optional,
or see below for standard output models.
MENT1220V12XYZ: 12 V dc/15 A
MENT1220V15XYZ: 15 V dc/13 A
MENT1220V18XYZ: 18 V dc/11.7 A
MENT1220V24XYZ: 24 V dc/9.2 A
MENT1220V28XYZ: 28 V dc/7.9 A
MENT1220V32XYZ: 32 V dc/6.9 A
MENT1220V48XYZ: 48 V dc/4.6 A
UL 60950-1, 1st Edition, 2007-10-31 (Information Technology Equipment Safety - Part 1: General Requirements)
CSA C22.2 No. 60950-1-03, 1st Edition, 2006-07 (Information Technology
Equipment - Safety - Part 1: General Requirements)
SL POWER ELECTRONICS CORP
BLDG A
6050 KING DR
VENTURA CA 93003
UNITED STATES
This Report includes the following parts, in addition to this cover page:
1. Specific Inspection Criteria
2. Specific Technical Criteria
3. Clause Verdicts
4. Critical Components
5. Test Results
6. National Differences
7. Enclosures
Copyright © 2010
Issue Date:
2010-04-19
Page 2 of 2
Report Reference #
E136791-A19-UL-1
This is to certify that representative samples of the products covered by this Test Report have been investigated in accordance with the
above referenced Standards. The products have been found to comply with the requirements covering the category and the products are
judged to be eligible for Follow-Up Service under the indicated Test Procedure. The manufacturer is authorized to use the UL Mark on such
products which comply with this Test Report and any other applicable requirements of Underwriters Laboratories Inc. ('UL') in accordance
with the Follow-Up Service Agreement. Only those products which properly bear the UL Mark are considered as being covered by UL's
Follow-Up Service under the indicated Test Procedure.
The applicant is authorized to reproduce the referenced Test Report provided it is reproduced in its entirety.
UL authorizes the applicant to reproduce the latest pages of the referenced Test Report consisting of the first page of the Specific Technical
Criteria through to the end of the Conditions of Acceptability.
Any information and documentation involving UL Mark services are provided on behalf of Underwriters Laboratories Inc. (UL) or any
authorized licensee of UL.
Test Report By:
Reviewed By:
Tom Scheuffele
Senior Project Engineer
Underwriters Laboratories Inc.
David Feusier
Staff Engineer
Underwriters Laboratories Inc.
Copyright © 2010
Issue Date:
2010-04-19
Page 3 of 57
Report Reference #
E136791-A19-UL-1
SPECIFIC TECHNICAL CRITERIA
UL 60950-1, First Edition
Information technology equipment - SafetyPart 1: General Requirements
Report Reference No ........................: E136791-A19-UL-1
Compiled by .....................................: Tom Scheuffele
Reviewed by ....................................: David Feusier
Date of issue ....................................: 2010-04-19
Standards .........................................: UL 60950-1, 1st Edition, 2007-10-31 (Information Technology
Equipment - Safety - Part 1: General Requirements)
CSA C22.2 No. 60950-1-03, 1st Edition, 2006-07 (Information
Technology Equipment - Safety - Part 1: General Requirements)
Test procedure .................................: Component Recognition
Non-standard test method ...............: N/A
Test item description .......................: Power Supply
Trademark ........................................: None
Model and/or type reference ............: MENT1220VWXYZ, where V represents the generational differences
which may be any letter from A thru Z; W represents the output voltage
which may be any number from 12, 15, 18 or any number from 24 thru
48; X represents the output cable and connector which may be any two
alphanumeric digits; Y represents the AC inlet connector which may be
the letter F, N, or Q; F for C14 type AC inlet (Class I), N for C8 type AC
inlet (Class II), Q for C18 type AC inlet (Class II); and Z represents
non-safety related customer options which may be any two
alphanumeric digits.
Rating(s) ...........................................: Input: 100-240 V~, 50-60 Hz, 2.5-1.2 A
Output:
48 V maximum,
15 A maximum,
220 W optional,
or see below for standard output models.
MENT1220V12XYZ: 12 V dc/15 A
MENT1220V15XYZ: 15 V dc/13 A
MENT1220V18XYZ: 18 V dc/11.7 A
MENT1220V24XYZ: 24 V dc/9.2 A
MENT1220V28XYZ: 28 V dc/7.9 A
MENT1220V32XYZ: 32 V dc/6.9 A
MENT1220V48XYZ: 48 V dc/4.6 A
Underwriters Laboratories Inc.
Issue Date:
2010-04-19
Page 4 of 57
Report Reference #
E136791-A19-UL-1
Particulars: test item vs. test requirements
Equipment mobility .................................................... : transportable
Operating condition ................................................... : continuous
Mains supply tolerance (%) ....................................... : +6%, -10%
Tested for IT power systems .................................... : Yes
IT testing, phase-phase voltage (V) .......................... : 230
Class of equipment ................................................... : Class I (earthed) and Class II (double insulated)
Mass of equipment (kg) ............................................ : 1.3
Protection against ingress of water ........................... : IP X1
Possible test case verdicts:
- test case does not apply to the test object ............. : N / A
- test object does meet the requirement ................... : Pass
- test object does not meet the requirement ............. : Fail (acceptable only if a corresponding, less stringent
national requirement is "Pass")
General remarks:
- "(see Enclosure #)" refers to additional information appended to the Test Report
- "(see appended table)" refers to a table appended to the Test Report
- Throughout the Test Report a point is used as the decimal separator
Underwriters Laboratories Inc.
Issue Date:
2010-04-19
Page 5 of 57
Report Reference #
E136791-A19-UL-1
GENERAL PRODUCT INFORMATION:
CA1.0
Report Summary
CA1.1
N/A
CB1.0
Product Description
CB1.1
Switching Power Supply
CC1.0
Model Differences
CC1.1
The models differ in output ratings which requires different turns and gage in transformers T301 &
T302 and secondary circuitry component values to accommodate the rated output. Other
differences are output cable/connector, AC inlet options for Class I and Class II and non-safety
related customer options. In addition, the output + or - may be connected to ground/heatsink for
Model MENT1220VWXFZ.
CD1.0
Additional Information
CD1.1
N/A
CE1.0
Technical Considerations
CE1.3
The means of connection to the mains supply is: Detachable power cord
CE1.4
The product is intended for use on the following power systems: IT, TN and TT
CE1.5
The equipment disconnect device is considered to be: Appliance inlet
CE1.7
The product was investigated to the following additional standards: IEC 60950-1:2001, First Edition
inclusive of CENELEC Common Modifications. EN 60950-1:2001 + A11:2004 (which includes all
European national differences, including those specified in this test report). IEC 60529, (2001)
Edition 2.1.
CE1.12
The following were investigated as part of the protective earthing/bonding: Appliance inlet C14.
CE1.14
The following are available from the Applicant upon request: Installation (Safety) Instructions /
Manual, Schematic Diagrams
CF1.0
Engineering Conditions of Acceptability
CF1.1
For use only in or with complete equipment where the acceptability of the combination is
determined by Underwriters Laboratories Inc.
When installed in an end-product, consideration must be given to the following:
CF1.5
The following secondary output circuits are SELV: All
CF1.6
The following secondary output circuits are at hazardous energy levels: All
CF1.12
The maximum investigated branch circuit rating is: 20 A
CF1.13
The investigated Pollution Degree is: 2
CF1.18
The following magnetic devices (e.g. transformers or inductor) are provided with an OBJY2
Underwriters Laboratories Inc.
Issue Date:
2010-04-19
Page 6 of 57
Report Reference #
E136791-A19-UL-1
insulation system with the indicated rating greater than Class A (105°C): T301 and T302 (Class B)
CF1.20
The following components require special consideration during end-product Thermal (Heating)
tests due to the indicated maximum temperature measurements during component-level testing:
40 °C
Underwriters Laboratories Inc.
DEMKO CERTIFICATE
Certificate No.
Page
Date of Issue
150523-01
1/3
2010-04-23
Certificate Holder
SL POWER ELECTRONICS CORP
BLDG A, 6050 KING DR
VENTURA CA 93003, USA
Manufacturer
SL POWER ELECTRONICS CORP
BLDG A, 6050 KING DR
VENTURA CA 93003, USA
Production site
Certified Product
Model
Trademark
Rated Voltage / Frequency
Rated Current / Power
Insulation Class
Degree of protection (IP)
Tested acc. to
Test Report No.
Additional
Expire date
Certification Manager
Jan-Erik Storgaard
Certification Body
SL POWER ELECTRONICS XIANGHE
ANPING ECONOMIC & TECH DEVELOPING ZONE
XIANGHE, HEBEI 065402 CHINA
Power Supply
MENT1220VWXYZ
None
100-240 V~, 50-60 Hz
2.5-1.2 A
X1
EN 60950-1:2001 + A11:2004
E136791-A19-CB-1 issue date 2010-04-19
See appendix
2010-12-01
The product and production sites listed on the certificate comply with the D-mark requirements and the UL Global Service
Agreement, with reference to Terms and Conditions for the D mark. The Owner of the certificate is entitled to use the δ or for cables
<DEMKO>, for the products listed on the certificate and manufactured at the production sites listed. UL has to be informed in writing
about any changes to the product or production site in accordance with the Term and Conditions of the D mark. The validity of the
certificate is shortened if the EU legislation require re-testing and re-certification due to new standards or amendments coming into
force before the expiry date.
UL International Demko A/S, Lyskaer 8, P.O. Box 514, DK-2730
Herlev, Denmark, Tel. +45 44 85 65 65, [email protected]
www.ul-europe.com
Appendix DEMKO CERTIFICATE
Certificate No.
Page
Date of Issue
150523-01
2/3
2010-04-23
Additional :
Type kye : where V represents the generational differences which
may be any letter from A thru Z; W represents the output voltage which may be
any number from 12, 15, 18 or any number from 24 thru 48; X represents the
output cable and connector which may be any two alphanumeric digits; Y
represents the AC inlet connector which may be the letter F, N, or Q; F for C14
type AC inlet (Class I), N for C8 type AC inlet (Class II), Q for C18 type AC inlet
(Class II); and Z represents non-safety related customer options which may be
any two alphanumeric digits.
Output:
48 V maximum,
15 A maximum,
220 W optional,
or see below for standard output models.
MENT1220V12XYZ: 12 V dc/15 A
MENT1220V15XYZ: 15 V dc/13 A
MENT1220V18XYZ: 18 V dc/11.7 A
MENT1220V24XYZ: 24 V dc/9.2 A
MENT1220V28XYZ: 28 V dc/7.9 A
MENT1220V32XYZ: 32 V dc/6.9 A
MENT1220V48XYZ: 48 V dc/4.6 A
The certificate has been issued on the basis of CB certificate (CB Test certificate) No.
US/14949/UL, issued by Underwriters Laboratories Inc, dated 2010-04-19
Certification Body
UL International Demko A/S, Lyskaer 8, P.O. Box 514, DK-2730
Herlev, Denmark, Tel. +45 44 85 65 65, [email protected]
www.ul-europe.com
Appendix DEMKO Certificate
Certification Mark
Certificate No.
Page
Date of Issue
D-mark
Certification Body
UL International Demko A/S, Lyskaer 8, P.O. Box 514, DK-2730
Herlev, Denmark, Tel. +45 44 85 65 65, [email protected]
www.ul-europe.com
150523-01
3/3