GLC65 Commercial/GLM65 Medical 65 Watt Single Output Global Performance Switchers GLOBAL PERFORMANCE SWITCHERS FEATURES: • 4.1 W/in3 • Compact (3.0” x 5.0” x 1.06”) • Ultra-high efficiency (up to 94%) using patented technology • Meets harmonic requirements of IEC1000-3-2, Class A • Conducted EMI exceeds FCC Class B and CISPR 22 Class B (Commercial models) and CISPR 11 Class B (Medical models) • 2-year warranty • Exempt from line harmonics standard EN61000-3-2 • Commercial Approved to UL1950, IEC950, EN60950, CSA22.2 No. 950 • Medical Approved to UL2601, EN60601, CSA22.2 No. 601.1 • Multiple output versions also available • RoHS models available (G suffix) • marked to LVD SPECIFICATIONS Ac Input 90-264 Vac, 47-63 Hz single phase. Input Current Maximum input current at minimum output voltage and output overload will be less than 1.7 A. Meets input current harmonic requirements of IEC1000-3-2. Output Power Normal continuous output power is 65 W, 75 W peak for 60 s. The 3.3 Vdc unit is 36.3 W and the 5 Vdc unit is 55 W continuous. Hold-Up Time 20 ms from loss of ac input at 65 W load, from 120 Vac input. Overload Protection Fully protected against short circuit and output overload. Short circuit protection is cycling type power limit. Output Noise 0.5% rms, 1% pk-pk, 20 MHz bandwidth, differential mode. Measured with scope probe directly across output terminals of the power supply with load terminated with 0.1 μF capacitor. Transient Response Main output: 500 μs typical response time for return to within 0.5% of final value for a 50% load step within the regulation limits of minimum and maximum load, ∆i/∆t<0.2 A/μs. Maximum voltage deviation is 3.5%. Startup/shutdown overshoot less than 3%. Voltage Adjustment Adjustable potentiometer capable of ±5% change from nominal setting. Efficiency 82 to 94% minimum at full rated load, nominal input voltage, depending on model. Inrush Current Inrush is limited by internal thermistor. The inrush at 240 Vac, averaged over the first ac half-cycle under cold start conditions will not exceed 37A. EMI/EMC Compliance All models include built-in EMI filtering to meet the following emissions requirements: EMI SPECIFICATIONS COMPLIANCE LEVEL Conducted Emissions GLC65 Conducted Emissions GLM65 Static Discharge RF Field Susceptibility Fast Transients/Bursts Surge Susceptibility EN55022 Class B; FCC Class B EN55011 Class B: FCC Class B EN61000-4-2, 6 kV contact, 8 kV air EN61000-4-3, 3 V/meter EN61000-4-4, 2 kV, 5 kHz EN61000-4-5, 1 kV diff., 2 kV com. Commercial Leakage Current Under normal conditions, leakage current is 425 μA with 132 Vac @ 60 Hz input. Commercial Safety All GLC models are approved to UL1950, CSA22.2 No. 950, IEC950 and EN60950. Medical Leakage Current The maximum leakage current under single-fault conditions (254 Vac @ 50 Hz) is 120 μA. Under normal conditions, leakage current is 31μA with 132 Vac @ 60 Hz input. Medical Safety All GLM models are approved to UL2601, CSA22.2 No. 601, IEC601-1 and EN60601. Consult factory for approval status. Temperature Coefficient: 0.03%°C typical on all outputs. Remote Sense Provided as standard feature on all models. Includes open sense protection. Minimum Load No minimum load required. All specifications are typical at nominal input, full load at 25OC unless otherwise stated Commercial Model Medical Model Output Current Total Regulation V1 Adjustment V1 OVP Setpoint Ripple and Noise GLC65-5 GLM65-5 5.1 V 9/11 A * 2% ±5% 6.2 ± 0.6 V 1% GLC65-12 GLM65-12 12 V 5.5 A 2% ±5% 14 ± 1.1 V 1% GLC65-15 GLM65-15 15 V 4.3 A 2% ±5% 18.5 ± 1.5 V 1% GLC65-18 GLM65-18 18 V 3.6 A 2% ±5% 21.7 ± 2.0 V 1% GLC65-20 GLM65-20 20V 3.25 A 2% ±5% 24.5 ± 2.2 V 1% GLC65-24 GLM65-24 24 V 2.7 A 2% ±5% 28 ± 2.5 V 1% GLC65-28 GLM65-28 28 V 2.3 A 2% ±5% 34 ± 2.8 V 1% GLC65-48 GLM65-48 48 V 1.35 A 2% ±5% 55 ± 4.0 V 1% • Note: * 9 A convection, 11 A with fan cooling GLC65/GLM65 - SINGLE OUTPUT - MECHANICAL SPECIFICATIONS 1.20 30.28 ENVIRONMENTAL SPECIFICATIONS OPERATING NON-OPERATING Temperature (A) 0 to 50° -40 to +85°C Humidity (A) 0 to 95% RH 0 to 95% RH Shock (B) 20 gpk 40 gpk Altitude -500 to 10,000 ft -500 to 40,000 ft Vibration (C) 1.5 g rms’ 0.003 g /Hz 5 g rms’ 0.026 g /Hz 2 A. Units should be allowed to warm up/operate under non-condensing conditions before application of power. Derate output current and total output power by 2.5% per °C above 50°C. B. Shock testing—half-sinusoidal, 10 ± 3 ms duration, ± direction, 3 orthogonal axes, total 6 shocks. 2 C. Random vibration—10 to 2000Hz, 6dB/octave roll-off from 350 to 2000Hz, 3 orthogonal axes. Tested for 10 min./axis operating and 1hr./ axis non-operating. SL Power Electronics Corp., 6050 King Drive, Bldg. A, Ventura, CA 93003, USA. Phone:(805) 486 4565 Fax:(805) 487 8911 www.slpower.com Rev. 01/07. Data Sheet © 2007 SL Power Electronics, Inc. The information and specifications contained in this data sheet are believed to be correct at time of publication. However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice.