G2T60 Instructions

SL POWER ELECTRONICS CORP.
6050 King Drive, Bldg. A
Ventura, CA 93003 + 805-486-4565
Internet: www.slpower.com
G2T60 SERIES
INSTALLATION INSTRUCTIONS
MODEL NUMBERS: G2T60-X-YYYG, where X = 12, 15, 18, 24 or 48 which represents the output
voltage rating –YYY is value added options not related to Safety and G represents RoHS Compliance.
RATINGS:
Input:
Output:
100-240 V ac, 1.5 A, 50/60 Hz
MODEL
G2T60-12
G2T60-15
G2T60-18
G2T60-24
G2T60-48
Notes:
1.
2.
40 °C Ambient
Convection Cooled
12 V dc 4.2 A
15 V dc 4.0 A
18 V dc 3.35 A
24 V dc 2.1 A
48 V dc 1.35 A
50 °C Ambient
Convection Cooled
12 V dc 3.35 A
15 V dc 3.7 A
18 V dc 3.1 A
24 V dc 1.9 A
48 V dc 1.25 A
50 °C Ambient
100 LFM Airflow
12 V dc 5.0 A
15 V dc 4.35 A
18 V dc 3.6 A
24 V dc 2.7 A
48 V dc 1.35 A
Maximum Operating Relative Humidity 96 %, no condensation.
Storage: -40 to +85 °C. Units should be allowed to warm-up under non-condensing conditions before application of
power.
CERTIFICATION: All models are Certified to be in compliance with the applicable requirements of
EN/IEC/UL 60601-1 and CSA 22.2 No. 601.1. In addition, all models (except G2T60-18) are Certified
to be in compliance with EN/IEC/UL/CSA 60950-1.
CLASSIFICATION: (5.1) Protection against electric shock = Class II
(In accordance with sub- (5.2) Degree of protection against electric shock = Signal output or intermediate
clause 5 of IEC 60601-1) (5.3) Protection against harmful ingress of water = Ordinary (no protection)
(5.5) Have not been evaluated for use in the presence of a flammable anaesthetic
mixture with air, oxygen, or nitrous oxide. This evaluation is to be made
on the end equipment by the OEM.
(5.6) Mode of operation = Continuous
SAFETY DECLARATION: SL Power Electronics Corp. (SLPE) declares under our sole
responsibility that all models listed above are in conformity with the applicable
requirements of EN 60950-1 following the provisions of the Low Voltage Directive
2006/95/EC.
OUTPUT: The output must not be connected to Earth ground or to metallic enclosure in the end
application. The output has not been evaluated for direct patient connection (consult factory for details).
The DC output is SELV under normal and single fault conditions.
OVERVOLTAGE PROTECTION: The output is monitored for an overvoltage condition. In some
applications where an overvoltage condition could result in a hazard as defined in applicable safety
standards, redundant or additional overvoltage protection may be required. Consult factory for details.
41-35510-0002 Rev. D 08/18/2008
Page 1 of 2
ISOLATION: The creepage distance between primary and secondary circuits is 8 mm minimum. The
required creepage and clearance distances from primary circuits to secondary circuits must be
maintained after installation to preserve the intended safety.
TEMPERATURES: The maximum operating temperatures of certain safety components, as defined in
the applicable safety standards, must not be exceeded after installation to preserve the intended safety.
The output power, ambient air temperature and the availability, amount, direction and/or restriction of
airflow influence the temperatures of these components.
OVERCURRENT PROTECTION: Fuses for both Line and Neutral are provided in the power supply.
NOTE: For use in permanently installed equipment, remove Fuse F2 and replace with a jumper wire.
WARNING! RISK OF FIRE! A blown internal fuse is an indication of catastrophic failure of circuit
component(s). Refer to fuse marking on the power supply for rating. Repair must be performed by
SLPE authorized personnel.
WARNING! SHOCK HAZARD! Dangerous voltages are present on some components, printed wiring
traces and heatsinks.
EXPLANATION OF SYMBOLS
Alternating Current
Direct Current
Attention, Consult
Accompanying Documents
Attention, Dangerous Voltages
Class II Equipment
CONNECTIONS
J1 Pin
1
3
AC Input
Line
Neutral
J2 Pin
DC Output
1
2
3
4
Output (+)
Output (+)
Return
Return
MATING CONNECTORS
J1
Amp Housing 640250-3 Contact 770476-1
J2
Amp Housing 640250-4 Contact 770476-1
SLPE will not be liable for the safety, reliability or performance of these power supplies if a) any changes, modifications or repairs are carried out by other than authorized agents of
SLPE, or b) the installation of the supply is not in accordance with these installation instructions and the applicable UL, CSA, EN, and IEC safety standards.
41-35510-0002 Rev. D 08/18/2008
Page 2 of 2