GNT60 MEDICAL SERIES SINGLE OUTPUT POWER SUPPLY Low Power Medical Power Supplies 65 Watt AC/DC Universal Input Power Supply Summary: • 100 - 240 Vac nominal input range • Overvoltage and short circuit protection • Approved to UL, CSA and EN Standards • Class II input available (G2T60) DC Power Supplies • RoHS Compliant Model Available (G suffix) The GNT60 Series is a 65 W universal input AC/DC power supply in a very small footprint. With the medical approvals the GNT60 is ideal for a variety of medical device applications including small single board computers, battery charging, running small motors, pumps, and solenoids. The series, with approval to 60601-1 and 60950 standards, improves design-in time and reduces end system compliance costs. Specifications: OUPUT SPECIFICATIONS Output Power Natural Convection Total Regulation INPUT SPECIFICATIONS 60 Watts max.(65 W with airflow) See table Input Voltage range Universal input See table Input surge current Thermistor limited 37 A max. Input frequency 100-240 nom (85 - 264 max) Vac 55 Hz +/- 10 Hz Rise time At turn-on 2.0 s max. Transient response Main output 50% 0.2 A/μs 3.55% max. dev. 1 μs recovery to 0.5% Ground Leakage current 264 Vac 60 Hz 300 μA max. (400 μA single fault) Temperature Coefficient +/-0.03%/oC Input current 120 Vac 1.2 A 230 Vac 0.7 A Overvoltage protection 108% to 130% Input fuse F1,F2 3.15 A Short Circuit protection Cycling/foldback Yes EMC INFORMATION ENVIRONMENTAL SPECIFICATIONS Conducted emissions EN55011 Level B Radiated emissions EN55011 Level A Line freq. harmonics EN61000-3-2 Complies Voltage fluctuations EN61000-3-3 Complies ESD Air EN61000-4-2 8 kV contact ESD Contact EN61000-4-2 6 kV air Radiated immunity EN61000-4-3 3 V/m Fast Transients (EFT) EN61000-4-4 2 kV Line surge immunity EN61000-4-5 1 kV diff /2 kV cm Conducted immunity EN61000-4-6 3 Vrms Power freq. mag. field EN61000-4-8 3 A/m Voltage dip immunity EN61000-4-11 100 Vac 5 cycles 40 % Vnom 22% load 25 cycles 70 % Vnom 52% load 0.5 cycles <5% Vnom 88% load Thermal Performance operating ambient (see ratings chart) 0-70 oC non-operating -40 to +85 oC 0 - 50 oC Full load. See table. 50 -70 oC ambient derate to 50% Relative Humidity non-condensing 5% - 95% RH Maximum Altitude operating / non-operating 10,000 ft. / 40,000 ft. max. Vibration 5 Hz- 500 Hz 2.5 g rms Shock per MIL-STD-810E 516.4 part IV All specifications are typical at nominal input, full load at 25OC unless otherwise stated GENERAL SPECIFICATIONS Hold-up time 120 Vac, 60 Hz 16 ms at 60 Watts output Efficiency 120 Vac 60 W output >80 % Isolation voltage input to ouput input to ground 4000 Vac 1500 Vac Switching frequency fixed 60 KHz, +/- 5 KHz Safety Approvals UL/EN/IEC 60601-1 CSA22.2 No.601, UL/EN/IEC 60950-1 1st Edition, CSA22.2 No.60950-1-03 Maximum weight 140 g (0.29 lbs) MODEL NUMBER 50oC Airflow 65 W (1) 40oC Convection 50oC Convection RIPPLE REGULATION GNT60-12 12 V 5.0 A 12 V 4.2 A 12 V 3.35 A 120 mV 2% GNT60-15 15 V 4.35 A 15 V 4.0 A 15 V 3.7 A 150 mV 2% GNT60-24 24 V 2.7 A 24 V 2.1 A 24 V 1.9 A 240 mV 2% GNT60-48 48 V @ 1.35 A 48 V @ 1.25 A 48 V @ 1.35 A 480 mV 2% NOTES 1. All models 65 W with 100 lfm airflow except GNT60-12 (60 W) 2. When the input voltage is less than 90 Vac the operating temperature range is 0oC to 40oC. The ripple and regulation specs. may not be met. 3. Peak output rating is 70 Watts for 1 minute. 4. Noise 0.5% RMS, 1% Pk-Pk, 20 MHz Bandwidth, differential mode. Measured with scope probe directly across output terminals of the power supply. 5. Heatsink temperatures should not be allowed to exceed 90 oC 6. Installation data is online at www.condorpower.com 7. Add “G” suffix to model number for RoHS compliant model. 8. Convection cooling rating is 40 Watts worst case (GNT60-12 @ 50oC) Mechanical Notes INPUT J1 AMP P/N 640445-2 PIN 1 AC LINE PIN 3 AC NEUTRAL GROUND 0.187 FASTON OUTPUT J2 AMP P/N 640445-4 PIN 1 OUTPUT 1 PIN 2 OUTPUT 1 PIN 3 COMMON PIN 4 COMMON MATING CONNECTOR (TYCO/AMP) INPUT HOUSING 640250-3 CONTACT 640706-1 OUTPUT HOUSING 640250-4 CONTACT 640706-1 SL Power Electronics Corp., 6050 King Drive, Bldg. A, Ventura, CA 93003, USA. Phone:(805) 486 4565 Fax:(805) 487 8911 www.slpower.com. GNT60 Rev 4/7/10. Data Sheet © 2010 Condor DC Power Supplies Inc. The information and specifications contained in this data sheet are believed to be correct at time of publication. However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice.