GPFC160 Instructions

GPFC160 SERIES
INSTALLATION INSTRUCTIONS
SL POWER ELECTRONICS CORP.
6050 King Drive, Bldg. A
Ventura, CA 93003 + 805-486-4565
Internet: www.slpower.com
MODEL NUMBERS: GPFC160-X, where X represents the output voltage, which may be any number from 5 thru 48. May be followed
by suffix –CF to indicate optional cover/fan and/or suffix –XXX where XXX may be any number from 001 thru 999 to indicate value
added configurations that have no impact on safety and/or suffix G to indicate compliance to RoHS.
RATINGS:
Input: 100-240 V ac, 2.5 A, 50/60 Hz
Output: Refer to table for standard output voltage models.
5 thru 11.5 V @ 25 A or 127.5 W convection cooled; 31.3 A or 160 W with 26 cfm airflow and suffix –CF
11.6 thru 48 V @ 11.7 A or 140 W convection cooled; 13.3 A or 160 W with 26 cfm airflow and suffix –CF
Notes:
1.
2.
3.
MODEL
Convection Cooled
GPFC160-5
GPFC160-12
GPFC160-15
GPFC160-24
GPFC160-28
GPFC160-48
5.1 V dc 25 A
12 V dc 11.7 A
15 V dc 9.3 A
24 V dc 5.8 A
28 V dc 5.0 A
48 V dc 2.9 A
26 CFM Airflow
or Cover/Fan option (Suffix –CF)
5.1 V dc 31.3 A
12 V dc 13.3 A
15 V dc 10.7 A
24 V dc 6.7 A
28 V dc 5.7 A
48 V dc 3.4 A
Maximum ambient temperature for rated output power is 50 °C.
Maximum Operating Relative Humidity 96 %, no condensation.
Storage: -40 to +85 °C. Units should be allowed to warm-up under non-condensing conditions before application of power.
SAFETY DECLARATION: SL Power Electronics Corp. (SLPE) declares under our sole responsibility that all
models listed above are in conformity with the applicable requirements of EN 60950-1 following the provisions of the
Low Voltage Directive 2006/95/EC. All models are Certified to be in compliance with the applicable requirements of
UL 60950-1, CAN/CSA 22.2 No. 60950-1 (L3M1), and EN 60950-1. They are certified for Pollution Degree 2
environment and Class I TN-S power systems.
TEMPERATURES: The maximum operating temperatures of components used in this supply must not be exceeded after installation.
When operating supply with or without cover/fan option, the orientation of the supply, output power, ambient temperature and the
availability, amount, direction and/or restriction of natural airflow influences the temperatures of these components. Keeping the
temperature of the core of T4 below 110 °C will usually be sufficient to meet all other temperature requirements.
GROUNDING: The Protective Earth (ground) terminal or chassis must be bonded to Protective Earth in the host equipment. Using the
Protective Earth terminal on the supply for grounding the host equipment is not recommended. A separate dedicated grounding point
should be used.
OUTPUTS: All DC outputs are SELV under normal and single fault conditions.
ISOLATION: The components providing isolation from primary to secondary are 100 % tested at 3000 V ac. The creepage distance
between primary and ground is 2.5 mm minimum; between primary and secondary circuits is 6.4 mm minimum. Secondary to ground
creepage is not defined or controlled. The required creepage and clearance distances from primary circuits to ground and secondary circuits
must be maintained after installation to preserve the intended safety.
EXPLANATION OF SYMBOLS
WARNING! RISK OF FIRE! A blown internal fuse is an indication of catastrophic failure of circuit
component(s). Repair must be performed by SLPE authorized personnel.
Alternating Current
WARNING! SHOCK HAZARD! Dangerous voltages are present on some components and printed
wiring traces.
Attention, Consult
Accompanying Documents
CONNECTIONS
J2 Signal Out
J3 DC Output
J3 DC Output
1
3
5
1
2
3
4
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Power Fail
- Sense
+ Sense
Common
CAUTION: Do not exceed
5 A per pin on J3.
Output (+)
Output (+)
Output (+)
Output (+)
Return
Return
Return
Return
Attention, Dangerous Voltages
Earth (Ground)
J1 AC Input
AC Line
AC Neutral
Earth
Direct Current
Return
Return
Return
Return
Output (+)
Output (+)
Output (+)
Output (+)
MATING CONNECTORS
J1
Amp Housing 640250-5 Contact 770476-1
J2
Amp MTA-100 Receptacle
J3
Amp Housing 1-640250-6 Contact 770476-1
Fan Amp MTA-100 Receptacle
SLPE will not be liable for the safety, reliability or performance of these power supplies if a) any changes, modifications or repairs are carried out by other than authorized agents of SLPE,
or b) the installation of the supply is not in accordance with these installation instructions and the applicable UL, CSA, EN and IEC safety standards.
41-34394-0001 Rev G 08/22/07