GLC110 Instructions

GLC110 SERIES
INSTALLATION INSTRUCTIONS
SL POWER ELECTRONICS CORP.
6050 King Drive, Bldg. A
Ventura, CA 93003 + 805-486-4565
Internet: www.slpower.com
MODEL NUMBERS: GLC110-X, where X = 12, 15, 24, 212, 215, or 524. May be followed by suffix –L to indicate
optional chassis or –LC to indicate chassis/cover and/or suffix –XXX where XXX may be any number from 001 thru 999 to
indicate value added configurations that have no impact on safety and/or suffix G to indicate compliance to RoHS.
RATINGS:
Input: 100-240 V ac, 2.9 A, 50/60 Hz
Output:
MODEL
Output
GLC110-12
GLC110-15
GLC110-24
GLC110-212
#1
#1
#1
#1
#2
#1
#2
#1
#2
GLC110-215
GLC110-524
Notes:
Volts
12
15
24
+12
-12
+15
−15
+24
+5
0 CFM
60 Watts Max
With Cover
5.0 A
4.0 A
2.5 A
5.0 A
2.5 A
4.0 A
2.5 A
2.5 A
1.5 A
0 CFM
75 Watts Max
Without Cover
6.3 A
5.0 A
3.2 A
6.3 A
2.5 A
5.0 A
2.5 A
3.2 A
1.5 A
26 CFM
110 Watts Max
With or without cover
9.1 A
7.3 A
4.6 A
9.1 A
3.0 A
7.3 A
3.0 A
4.6 A
2.0 A
1. Wattage ratings are maximum continuous power, total of all outputs at ambient of 50 °C.
2. Maximum Operating Relative Humidity 96 %, no condensation.
3. Storage: -40 to +85 °C. Units should be allowed to warm-up under non-condensing conditions before application of power.
SAFETY DECLARATION: SL Power Electronics, Corp. (SLPE). declares under our sole responsibility that
all models listed above are in conformity with the applicable requirements of EN 60950-1 following the
provisions of the Low Voltage Directive 73/23/EEC. All models are Certified to be in compliance with the
applicable requirements of UL 60950-1, CSA 22.2 No. 60950-1 (L3M1), and EN 60950-1 for Pollution Degree 2
environment and Class I TN-S power systems. The outputs of the supplies meet the requirements for SELV and are not an
energy hazard.
Protection Class I requires that the ground terminal be bonded to Protective Earth in the end application. Using this terminal
for the primary system earthing terminal is not recommended.
Creepage and clearance distances from primary circuits to ground and secondary circuits, as defined in the applicable safety
standards, must be maintained after installation to preserve the intended safety.
The maximum operating temperatures of certain safety components, as defined in the applicable safety standards, must not be
exceeded after installation to preserve the intended safety. The output power, ambient air
EXPLANATION OF SYMBOLS
temperature and the availability, amount, direction and/or restriction of airflow influence the
Alternating Current
temperatures of these components.
Direct Current
WARNING!
RISK OF FIRE!
A blown fuse is an indication of catastrophic failure of circuit component(s). Repair must
be performed by Condor authorized personnel. Fuse F1 must be replaced with F 3.15A
250V, IEC 60127-2 type.
Attention, Consult
Accompanying Documents
Attention, Dangerous Voltages
Earth (Ground)
CONNECTIONS
J1 Pin
1
3
5
AC Input
Ground
Neutral
Line
J2 Pin
1
2
3
4
5
6
7
Single Output Models
DC Output J2 Pin
DC Output
+ Output
8
Return
+ Output
9
Return
+ Output
10
Power Fail
+ Output
11
N/C
Return
12
N/C
Return
13
N/C
Return
MATING CONNECTORS
J1
Amp/Tyco Housing 640250-5 Contact 640706-1
J2
Amp/Tyco Housing 1-640250-3 Contact 640706-1
J2 Pin
1
2
3
4
5
6
7
Multi-Output Models
DC Output
J2 Pin
DC Output
Output #1
8
Common
Output #1
9
Common
Output #1
10
Power Fail
Output #1
11
N/C
Common
12
Output #2 (-)
Common
13
Output #2 (+)
Common
CAUTION:
Do not exceed 5 A per contact.
SLPE. will not be liable for the safety, reliability or performance of these power supplies if a) any changes, modifications or repairs are carried out by other than authorized agents of
SLPE., or b) the installation of the supply is not in accordance with these installation instructions and the applicable UL, CSA, EN, and IEC safety standards.
41-34676-0001 Rev. E 6/19/07