GPFC125 SERIES INSTALLATION INSTRUCTIONS SL POWER ELECTRONICS CORP. 6050 King Drive, Bldg. A Ventura, CA 93003 + 805-486-4565 Internet: www.slpower.com MODEL NUMBERS: GPFC125X, where X represents the DC outputs listed in the table below. Models may or may not be followed by suffix –C, –XXX and/or G, where –C when used represents optional cover; XXX may be any number from 001 thru 999. The –XXX suffix are used for value added configurations that have no impact on safety and suffix G indicates compliance to RoHS. RATINGS: Input: 100-240 V ac, 2.5 A, 50/60 Hz Outputs: MODEL GPFC125A GPFC125B GPFC125C GPFC125D GPFC125E GPFC125F GPFC125G GPFC125H +5.0 V +5.0 V +5.0 V +5.0 V +5.0 V +5.0 V +5.0 V +3.3 V Output #1 Note 1 9A 9A 9A 9A 9A 9A 9A 9A Note 2 16 A 16 A 16 A 16 A 16 A 16 A 16 A 16 A +12.0 V +12.0 V +12.0 V +24.0 V +24.0 V +15.0 V +3.3 V +5.0 V Output #2 Note 1 4.0 A 4.0 A 4.0 A 3.0 A 3.0 A 3.5 A 7.0 A 4.0 A Note 2 7.0 A 7.0 A 7.0 A 4.5 A 4.5 A 6.0 A 10.0 A 7.0 A 12 V 12 V 15 V 12 V 15 V 15 V 12 V 12 V Output #3 Note 1 2.5 A 2.5 A 2.5 A 2.5 A 2.5 A 2.5 A 2.5 A 2.5 A Note 2 4A 4A 4A 4A 4A 4A 4A 4A -12 V -5 V -15 V -12 V -15 V -5 V -12 V -12 V Output #4 Note 1 Note 2 0.3 A 1A 0.3 A 1A 0.3 A 1A 0.3 A 1A 0.3 A 1A 0.3 A 1A 0.3 A 1A 0.3 A 1A 50 W max. total power, convection cooling. 80 W max. total power, convection cooling, unit mounted to min. 12 x 12 x 0.125 in. thick aluminum plate. 125 W max. total power with min. 200 LFM airflow over unit. 125 W max. total power with min. 250 LFM airflow over unit, with optional cover (-C suffix). Notes: 1. 2. 3. 4. 5. Maximum ratings with convection cooling. Maximum ratings with forced air cooling. Maximum ambient temperature for rated output power is 50 °C. Maximum Operating Relative Humidity 96 %, no condensation. Storage: -40 to +85 °C. Units should be allowed to warm-up under non-condensing conditions before application of power. SAFETY DECLARATION: SL Power Electronics Corp. declares under our sole responsibility that all models listed above are in conformity with the applicable requirements of EN 60950-1 following the provisions of the Low Voltage Directive 73/23/EEC. All models are Certified to be in compliance with the applicable requirements of UL 60950-1, CAN/CSA 22.2 No. 60950-1-03 (L3M1), and EN 60950-1. They are certified for Pollution Degree 2 environment and Class I TNS power systems. All DC outputs are SELV under normal and single fault conditions. TEMPERATURES: The maximum operating temperatures of components used in this supply must not be exceeded after installation. The orientation of the supply, output power, ambient temperature and the availability, amount, direction and/or restriction of natural airflow influences the temperatures of these components. GROUNDING: The Earth (Ground) terminal J1-5 and/or chassis must be bonded to Protective Earth in the end application. Using J1-5 for the end product protective earthing terminal is not recommended. A separate dedicated protective earthing point should be used. EXPLANATION OF SYM BOLS Alternating Current Direct Current SPACINGS: The required creepage and clearance distances from primary circuits to ground and secondary circuits must be maintained after installation to preserve the intended safety. Attention, Consult Accom panying Docum ents WARNING! RISK OF FIRE! A blown internal fuse is an indication of catastrophic failure of circuit component(s). Repair must be performed by SL Power Electronics Corp. authorized personnel. Attention, Dangerous Voltages Earth (Ground) WARNING! SHOCK HAZARD! Dangerous voltages are present on some components and printed wiring traces. CONNECTIONS J1 Pin Input J3 Pin Output J3 Pin 1 Output #4 (-) 10,11 Output #2 (+) 1 Power Fail Neutral 2,3,4 Output #1 (+) 12 Output #3 (+) 2 - Sense #1 Ground 5,6,7,8,9 Common 13 Output #3 (Rtn) 1 Line 3 5 Output CAUTION: Do not exceed 5 A per contact on J3. J2 Pin MATING CONNECTORS J1 Amp Housing 640250-5 Contact 770476-1 3 + Sense #1 J2 Amp MTA-100 Receptacle 4 Common J3 Amp Housing 1-640250-3 Contact 770476-1 SL Power Electronics Corp. will not be liable for the safety, reliability or performance of these power supplies if a) any changes, modifications or repairs are carried out by other than authorized agents of SL Power Electronics Corp., or b) the installation of the supply is not in accordance with these installation instructions and the applicable UL, CSA, and EN/IEC safety standards. 41-34961-0002 Rev D 09/25/06