GPM140 DS

GPC140 Commercial/GPM140 Medical
140 Watt Global Performance Switchers
FEATURES:
• Wide-range ac input 85-264 Vac
• 2-year warranty
• Conducted EMI exceeds FCC Class B and CISPR 22
Class B (Commercial models) and CISPR 11 Class B
(Medical models)
• Single outputs
• Commercial Approved to UL1950, IEC950,
EN60950 and CSA22.2-234 L3
• Medical Approved to UL2601-1, IEC601-1 and
CSA22.2 No. 601
marked to LVD
•
SPECIFICATIONS:
Ac Input
85-264 Vac, 47-63 Hz single phase.
Input Current
Maximum input current at 120 Vac, 60 Hz with full rated
output load: 3.7 A
Hold-Up Time
20ms minimum from loss of ac input at full load, nominal
line (115 Vac).
Output Power
140 W convection; 160 W with air flow. Peak ratings are
for 60 s maximum duration, 10% duty cycle.
Overload Protection
Fully protected against short circuit and output overload.
Short circuit protection is cycling type power limit on
output 1. Recovery after fault is automatic.
Overvoltage Protection
Main outputs: 130% ± 15% typical.
Efficiency
70% at full rated load, nominal input voltage, depending
on model and load distribution.
Input Protection
Internal ac fuse provided. Designed to blow only if a
catastrophic failure occurs in the unit.
Inrush Current
Inrush is limited by internal thermistors. Inrush at 240 Vac,
averaged over the first ac half-cycle under cold start
conditions will not exceed 60 A.
Temperature Coefficient
0.03%/°C typical on all outputs.
Thermal Shutdown
Provided as a standard feature. Designed to protect unit
from prolonged overtemperature.
Environmental
Designed for 0 to 50°C operation at full rated output
power; derate output current and total output power by
2.5% per °C above 50°C. See Environmental and
Packaging Specifications on next page.
Power Fail
TTL- or CMOS-compatible output goes low (< 0.5 V) 5 ms
before output voltage drops more than 4% below
nominal voltage upon loss of ac power. The signal is
factory set to trip on 84 to 94 Vac brown-out depending
upon incoming line impedance and distortion. Other
settings are available to the user through adjustment of
built-in potentiometer.
56
Output Noise
0.5% rms, 1% pk-pk, 20 MHz bandwidth, differential
mode. Measured with noise probe directly across output
terminals of the power supply.
Transient Response
Main output—500 µs typical response time for return to
within 0.5% of final value for a 50% load step change. ∆i/
∆t<0.2 A/µs. Maximum voltage deviation is 3.5%. Startup/
shutdown overshoot less than 3%.
Remote Sense
Provided as a standard feature.
Voltage Adjustment
Built-in potentiometer adjusts voltage ±5%.
Overload Protection
Factory set to begin power limiting at approximately 175 W.
EMI/EMC Compliance
All models include built-in EMI filtering to meet the
following emissions requirements:
EMI SPECIFICATIONS
Conducted Emissions GPC140
Conducted Emissions GPM140
Static Discharge
RF Field Susceptibility
Fast Transients/Bursts
Surge Susceptibility
COMPLIANCE LEVEL
EN55022 Class B; FCC Class B
EN55011 Class B; FCC Class B
EN61000-4-2, 6 kV contact, 8 kV air
EN61000-4-3, 3 V/meter
EN61000-4-4, 2 kV, 5 kHz
EN61000-4-5, 1 kV diff., 2 kV com.
Commercial Leakage Current
0.95 mA 254 Vac @ 60 Hz input.
Commercial Safety
Approved to UL1950, CSA22.2 No. 234 Level 3, IEC950
and EN60950. UL file #E135803 commercial; CSA
#LR46516 all models. The output(s) are intended for
safety earthed Signal Output and Intermediate Circuits
only. All dc outputs are SELV under normal and single
fault conditions.
Medical Leakage Current
60 µA 254 Vac @ 60 Hz input.
Medical Safety
Approved to UL2601, CSA22.2 No. 601 Level 3 and
IEC601. UL file E116994; CSA #LR46516. The output(s)
are intended for safety earthed Signal Output and
Intermediate Circuits only. The output(s) are not acceptable for patient connection without additional isolation. All
dc outputs are SELV under normal and single fault
conditions.
Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033
800-235-5929 • 805-486-4565 • FAX 805-487-8911 • www.condorpower.com
GPC140 Commercial/GPM140 Medical 140 Watt Multiple Output
Commercial
Model
Medical
Model
Output
Output
Minimum
Output
Maximum (B)
Output
Maximum (C)
Peak
Noise P-P
Total Regulation (A)
GPC140-5
GPM140-5
5V
0A
26 A
30 A
32 A
50 mV
2%
GPC140-12
GPM140-12
12 V
0A
11.7 A
13.4 A
14.6 A
120 mV
2%
GPC140-15
GPM140-15
15 V
0A
9.3 A
10.7 A
11.7 A
150 mV
2%
GPC140-24
GPM140-24
24 V
0A
5.8 A
6.7 A
7.3 A
240 mV
2%
GPC140-28
GPM140-28
28 V
0A
5A
5.7 A
6.3 A
280 mV
2%
A.Total regulation is defined as the maximum deviation from the nominal voltage for all steady-state conditions of initial voltage setting, input line voltage and output load.
B. Unrestricted natural convection cooling.
C. Requires 26cfm moving air.
GPC140/GPM140 MECHANICAL SPECIFICATIONS
Environmental
Specification
Operating
Non-operating
Temperature (A)
See individual specs
-40 to +85oC
0 to 95% RH
0 to 95% RH
20 gpk
40 gpk
Humidity (A)
Shock (B)
Altitude
Vibration (C)
-500 to 10,000 ft
-500 to 40,000 ft
1.5 grms, 0.003 g2/Hz
5 grms, 0.026 g2/Hz
A. Units should be allowed to warm up/operate under non-condensing conditions
before application of power.
B. Random vibration—10 to 2000Hz, 6dB/octave roll-off from 350 to 2000Hz, 3
orthogonal axes. Tested for 10 min./axis operating and 1 hr./axis non-operating.
C. Shock testing—half-sinusoidal, 10 ± 3 ms duration, ± direction, 3 orthogonal axes,
total 6 shocks.
Condor D.C. Power Supplies, Inc., 2311 Statham Parkway, Oxnard, CA 93033
800-235-5929 • 805-486-4565 • FAX 805-487-8911 • www.condorpower.com
57