MINT1110 Safety Certificates

Issue Date:
2009-04-10
Page 3 of 58
Report Reference #
E116994-A48-UL-1
SPECIFIC TECHNICAL CRITERIA
TEST REPORT
UL 60601-1
Medical Electrical Equipment
Part 1: General requirements for safety
Report Reference No ........................: E116994-A48-UL-1
Compiled by .....................................: Ahmad Daoudi
Reviewed by ....................................: Elizabeth Drew
Date of issue ....................................: 2009-04-10
Standards .........................................: UL 60601-1, 1st Edition, 2006-04-26 (Medical Electrical Equipment,
Part 1: General Requirements for Safety)
CAN/CSA-C22.2 No. 601.1-M90, 2005 (Medical Electrical Equipment Part 1: General Requirements for Safety)
Test procedure .................................: Component Recognition
Non-standard test method ...............: N/A
Test item description .......................: Component - Power Supply
Trademark ........................................:
Model and/or type reference ............: MINT1110AXYKZ Series
Where: MINT is Medical Internal Model,
1 is the number of outputs,
110 is the Output Wattage i.e. 110 W,
A: is any Alpha character A-Z which indicates changes not related to
Safety,
X: is a 2 digit numeric character that represents the Output Voltage.
Voltage Range is 12-24Vdc.
Y: Output Connector Options
K: Input Connector Options
Z: Configuration: 01 is Standard, 02-99 Modifications which have no
impact on Safety
Rating(s) ...........................................: Input:
100-240Vac, 50-60Hz, 1.4A
Output:
MINT1110A1208K01 Series - Rated 12Vdc, 7.5A
MINT1110A1508K01 Series - Rated 15Vdc, 6.5A
MINT1110A1808K01 Series - Rated 18Vdc, 5.8A
MINT1110A1908K01 Series - Rated 19Vdc, 5.8A
MINT1110A2408K01 Series - Rated 24Vdc, 4.6A
TRF No.: IEC60601_1C
Underwriters Laboratories Inc.
Issue Date:
2009-04-10
Page 4 of 58
Report Reference #
E116994-A48-UL-1
GENERAL INFORMATION
Test item particulars (see also clause 5):
Classification of installation and use ......................... :
For building-in
Supply connection ..................................................... :
Header type connector for internal wiring
Accessories and detachable parts included in the
evaluation .................................................................. :
None
Options included ....................................................... :
None
Possible test case verdicts:
- test case does not apply to the test object ............. :
N/A
- test object does meet the requirement ................... :
P(Pass)
- test object does not meet the requirement ............. :
F(Fail) (acceptable only if a corresponding, less
stringent national requirement is "Pass")
Abbreviations used in the report:
- normal condition ............................................ :
N.C. - single fault condition ................ :
S.F.C.
- operational insulation ..................................... :
OP
- basic insulation ........................ :
BI
- basic insulation between parts of opposite
polarity:
BOP - supplementary insulation ......... :
SI
- double insulation ............................................ :
DI
RI
- reinforced insulation ................ :
General remarks:
- "(see Enclosure #)" refers to additional information appended to the Test Report
- "(see appended table)" refers to a table appended to the Test Report
- Throughout the Test Report a point is used as the decimal separator
General Product Information:
CA1.0
Report Summary
CA1.1
N/A
CB1.0
Product Description
CB1.1
The MINT1110 Series are open-frame AC/DC power supplies, designed for building-in.
MINT 1110 A X Y K Z Series Model Number Guide
MINT: Medical Internal Model number prefix.
1: Signifies number of outputs: 1
110: Output wattage= 110 W.
A: Signifies generational differences, not evaluated by UL or related to safety, such as energy
star level changes, EMC level changes; may be any letter from A to Z.
X: Output voltage: Numeric indicator from 12 to 24; i.e. 12 = 12 Vdc
Y: Output connector options
TRF No.: IEC60601_1C
Underwriters Laboratories Inc.
Issue Date:
2009-04-10
Page 5 of 58
Report Reference #
E116994-A48-UL-1
K: Input connector options
Z: Configuration: 01 = standard, 02-99 for modifications, which has no impact on safety
CC1.0
Model Differences
CC1.1
The power supplies in the MINT1110 Series are similar to each other, and differ only in minor
component changes in the secondary circuit and the number for windings for T1 to accommodate
for the different output voltages.
Model MINT1110A1908K01 (19 Vdc Output version) is similar to the other Models, except the
transformer has an insulation system rated Class F (155C). All other models utilize a Class B
(130C) insulation system for the transformer assembly.
CD1.0
Additional Information
CD1.1
Electrical Schematics are not provided in this report, in accordance with the Applicant's request.
The electrical schematics can be obtained from the Applicant upon request.
CE1.0
Technical Considerations
CE1.1
The product was investigated to the following
additional standards:
CAN/CSA-C22.2 No. 601.1-M90 (R2005)
(includes National Differences for Canada), UL
60601-1, 1st Edition, 2006-04-26 (includes
National Differences for USA), EN 60601-1:
1990 + A1:1993 + A2:1995 + A13:1996, IEC
60601-1
CE1.2
The product was not investigated to the
following standards or clauses:
Clause 52.1, Programmable Electronic Systems
(IEC 601-1-4), Clause 48, Biocompatibility (ISO
10993-1), Clause 36, Electromagnetic
Compatibility (IEC 601-1-2)
CE1.4
The degree of protection against harmful
ingress of water is:
Ordinary
CE1.5
The following accessories were investigated for None
use with the product:
CE1.6
The mode of operation is:
Continuous
CE1.7
Software is relied upon for meeting safety
requirements related to mechanical, fire and
shock:
No
CE1.8
The product is suitable for use in the presence
of a flammable anesthetics mixture with air or
oxygen or with nitrous oxide:
No
CF1.0
Engineering Conditions of Acceptability
CF1.1
For use only in or with complete equipment where the acceptability of the combination is
determined by Underwriters Laboratories Inc.
TRF No.: IEC60601_1C
Underwriters Laboratories Inc.
Issue Date:
2009-04-10
Page 6 of 58
Report Reference #
E116994-A48-UL-1
When installed in an end-product, consideration must be given to the following:
CF2.0
This power supply has been evaluated as Class -I, continuous operation, ordinary equipment and
has not been evaluated for use in the presence
of a flammable anesthetic mixture with air,
oxygen or nitrous oxide.
CF2.1
This component has been judged on the basis -of the required spacings in the First Edition of
the Standards for Medical Equipment, Part 1:
General Requirements for Safety, UL60601-1
and CSA 22.2 No. 601.1, which covers the end
use product for which the component is
designed.
CF2.2
The component shall be installed in compliance -with the enclosure, mounting, spacings,
casualty markings and segregation
requirements of the end-use application.
CF2.3
Consideration should be given to measuring the -temperature on power electronic components
and transformer windings when the power
supply is installed in the end-use equipment.
CF2.4
The input/output connectors are not acceptable -for field connection; they are only intended for
connection to mating connectors of internal
wiring inside the end-use machine. the output
circuits have not been evaluated for direct
patient connection (Type B, BF or CF).
CF2.5
The component should be properly bonded to
the ground in the end-use equipment.
--
CF2.6
Leakage Current testing should be repeated in
the end-product application.
--
CF2.7
The Power Transformer (T1) on the 12, 15, 18
and 24 V models comply with Class B (130C)
limits.
--
CF2.8
The Power Transformer (T1) on the
MINT1110A1908K01 comply with Class F
(155C) limits.
--
TRF No.: IEC60601_1C
Underwriters Laboratories Inc.