For more information, please visit the product page. date 08/28/2012 page 1 of 5 SERIES: VUM-D400-D│ DESCRIPTION: AC-DC POWER SUPPLY FEATURES • safety approvals: UL 60950-1, CSA C22.2 No. 60950-1-03 • dual output • current monitoring and remote voltage adjustments (margin) • compact 1U size and high power density: 5.56 W/inch3 • power factor corrected to EN 61000-3-2 Class D • metal enclosed • short circuit, overload, over voltage and over temperature protections • optional IEC320 AC inlet or terminal block • optional current sharing RoHS output voltage1,2,3 output current4 ripple and noise5,6 efficiency (Vdc) max (A) max (% Vp-p) typ (%) VUM-D400-D312 3.3 12 40 25 ±1 75 VUM-D400-D324 3.3 24 40 12.5 ±1 75 VUM-D400-D512 5 12 40 25 ±1 75 VUM-D400-D524 5 24 40 12.5 ±1 75 VUM-D400-D1242 12 24 25 12.5 ±1 75 MODEL Notes: 1. 2. 3. 4. 5. 6. output is fully isolated output voltage is measured at output power connector provides peak power of 700 W within 500 μs for all models 22.95 CFM cooling 1% minimum load is required to maintain the ripple and regulation Ripple and noise is measured from 10 KHz to 20 MHz at output terminals with a 0.1 μF ceramic capacitor and a 22 μF electrolytic capacitor in parallel PART NUMBER KEY VUM-D400 - DXXX-X Base Number Preset Output Voltage cui.com Current Sharing: “blank” = N/A I = available For more information, please visit the product page. CUI Inc │ SERIES: VUM-D400-D │ DESCRIPTION: AC-DC POWER SUPPLY date 08/28/2012 │ page 2 of 5 INPUT parameter conditions/description min voltage typ 90 frequency current 47 at 90 Vac, full load inrush current at 230 Vac, full load, cold start input fuse built-in ac fuse. A blown fuse usually indicates permanent damage to the power supply serviceable by factory only. active power correction meets EN 61000-3-2 Class D max units 264 Vac 63 Hz 6.35 A 35 A max units OUTPUT parameter conditions/description min total regulation ±5 transient response output voltage returns to within 1% in less than 2.5 ms for a 50% load change, peak transient does not exceed 5% overshoot turn-on and turn-off overshoot shall not exceed 5% over nominal voltage turn-on delay at 230 Vac hold-up time at 80% load adjustment range output user adjustable 20 s ms ±5 % 30 kHz designated as RS+ and RS- on CN3. Total voltage compensation for cable losses with respect to the main output. remote on/off defined RSW on CN3, requiring a low signal to inhibit output. LED display (LED 1) green - the power supply is operating normally. orange - when any protection occurs or RSW is low. power good designated as PG on CN3. This signal goes high 100~500 ms after the output reaches regulation. It goes low at least 1 ms before loss of regulation. current sharing designated as CSH on CN3, optional single wired for forced surrent sharing function and parallel up to 4 units within 10% accuracy at full load. current monitor designated as CMN on CN3 for for current sense for 0.5~3 Vdc to represent 0~100% output current. AC fail (optional)3 designated as ACF on CN3 to monitor the input voltage when input goes under 80 ±5 Vac the signal will go low (0 V) and then go high (+5 V) once it reappears over 86 Vac. Notes: % 1 switching frequency remote sense2 typ 1. 1% minimum load is required to maintain ripple and regulation 2. Not available for current sharing models 3. Input voltage protection must be disabled when AC Fail is enabled PROTECTIONS parameter conditions/description min input under voltage protection Power supply shuts down when ac input is under 80 ±5 Vac. When ac line reappears over 86 ±5 Vac, the power supply restarts automatically. over voltage protection shutdown and latches, ac input reset required to restart over current protection auto recovery short circuit protection continuous, auto recovery upon removal of short 110 over temperature protection shutdown, auto recovery 85 cui.com typ max units 130 % 140 %Io °C For more information, please visit the product page. CUI Inc │ SERIES: VUM-D400-D │ DESCRIPTION: AC-DC POWER SUPPLY date 08/28/2012 │ page 3 of 5 SAFETY & COMPLIANCE parameter conditions/description isolation voltage primary to secondary for 3 seconds primary to transformer core for 3 seconds primary to earth ground for 3 seconds min typ max safety approvals UL 60950-1, CSA C22.2 No. 60950-1-03, TUV EN 60950-1, CE Mark (LVD) EN 61204-3/61000-3-(2,3) & IEC 61000-4 Series Regulations, CB EMI/EMC FCC Part 15, CISPR22 Class B, conducted leakage current at 264 Vac 1.5 mA grounding test allowable resistance measured when 40 A current is applied from the ground pin of the three prong plug to the farthest earthed connection point. 0.1 Ω RoHS compliant yes MTBF according to MIL-HBK-217F at 30°C 4,000 1,500 1,500 units Vac Vac Vac 100,000 hours ENVIRONMENTAL parameter conditions/description operating temperature derating linearly at 2.5% from 50~70°C min storage temperature max units 0 typ 70 °C -20 85 °C operating humidity non-condensing 5 90 %RH storage humidity non-condensing 5 95 %RH cui.com For more information, please visit the product page. CUI Inc │ SERIES: VUM-D400-D │ DESCRIPTION: AC-DC POWER SUPPLY date 08/28/2012 │ page 4 of 5 MECHANICAL parameter conditions/description dimensions 9 x 5 x 1.6 (228.6 x 127 x 40.64 mm) min typ max units inch weight 1.0 Mounting screws kg 6-32, 1/4” or shorter MECHANICAL DRAWING FAN FA units: inches (mm) tolerance: inches: x.xx = ±0.02 mm: x.xx = ±0.5 C C B B B B C C V2 L N C C B B B C INPUT CONNECTOR (CN1) DINKLE DT-35-A02W-03 (option 2) Suggested mating plug IEC320 Suggested mating connector Molex 19198-0016 or similar OUTPUT CONNECTOR (CN2) FAN Suggested mating connector JST XHP-5 or equivalent Contact: SXH-002T-P0.6 Suggested mating connector JST XHP-2 or equivalent, Contact: SXH-001T-P0.6 PIN FUNCTION 1 RTN - return 2 PG - power good signal RSW - remore on/off Suggested mating connector Molex 19198-0045 or similar Suggested mating connector Molex 09-91-1600 4 RS- - remote sense (-) 5 RS+ - remote sense (+) PIN FUNCTION +Vo 1~6 +Vo 3~5 RTN 7~13 RTN 6 -Vo 14~16 -Vo cui.com M OUN UN TING HOL OLE: B:6-32 UNC C (Zn-plated)8 PLACE ACE C:M M4X0.7 UNC U 8 PLACE 8 PL JS B2B-XH-A 3 FUNCTION V1 JS B5B-XH-A Molex 26-48-1161 or similar. (option 2) PIN V1 LOGIC CONNECTOR (CN3) Howder HD-121-6P (option 1) 1~2 RTN RT B C IEC320 or equivalent snap-in mounting type (option 1) V2 RTN RT For more information, please visit the product page. CUI Inc │ SERIES: VUM-D400-D │ DESCRIPTION: AC-DC POWER SUPPLY date 08/28/2012 │ page 5 of 5 REVISION HISTORY rev. description date 1.0 initial release 07/10/2006 1.01 new template applied, V-Infinity branding removed 08/28/2012 The revision history provided is for informational purposes only and is believed to be accurate. Headquarters 20050 SW 112th Ave. Tualatin, OR 97062 800.275.4899 Fax 503.612.2383 cui.com [email protected] CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.