For more information, please visit the product page. date 06/18/2014 page 1 of 5 SERIES: VPM-S500-R│ DESCRIPTION: AC-DC POWER SUPPLY FEATURES • current monitoring and remote voltage adjustments (margin) • short circuit, overload, over voltage and over temperature protections • optional IEC320 AC inlet or terminal block • current sharing RoHS MODEL preset voltage VPM-S500-03R output voltage1,2,3 output current ripple and noise4,5 output power6 efficiency (Vdc) min (Vdc) max (Vdc) max (A) max (% Vp-p) max (W) typ (%) 3.3 2 3.3 80 75 mV 264 70 VPM-S500-05R 5 5 6 80 75 mV 400 75 VPM-S500-12R 12 12 15 41.67 ±1 500 80 VPM-S500-18R 18 16 21 31.25 ±1 500 83 VPM-S500-24R 24 22 30 22.73 ±1 500 83 VPM-S500-36R 36 31 41 16.13 ±1 500 83 VPM-S500-48R 48 42 55 10.42 ±1 500 83 Notes: 1. 2. 3. 4. 5. 6. customer must specify output voltage output is fully isolated output voltage is measured at output power connector 1% minimum load is required to maintain the ripple and regulation Ripple & noise are measured at 20 MHz BW with 0.1 µF ceramic cap and a 22 µF electrolytic capacitors on the output provides peak power of 900 W within 500 µs for all models PART NUMBER KEY VPM-S500 - XX R X Base Number Preset Output Voltage cui.com Current Sharing: “blank” = N/A I = available For more information, please visit the product page. CUI Inc │ SERIES: VPM-S500-R │ DESCRIPTION: AC-DC POWER SUPPLY date 06/18/2014 │ page 2 of 5 INPUT parameter conditions/description min voltage frequency max units 90 264 Vac 47 63 Hz 8 A 70 A max units current at 90-264 Vac, full load inrush current at 230 Vac, full load, cold start input fuse Built-in ac fuse. A blown fuse usually indicates permanent damage to the power supply serviceable by factory only. power factor correction at 230 Vac, full load typ 0.98 OUTPUT parameter conditions/description min total regulation typ ±1 transient response output voltage returns to within 1% in less than 2.5 ms for a 50% load change. Peak transient does not exceed 5%. overshoot turn-on and turn-off overshoot shall not exceed 5% over nominal voltage. start-up time at 230 Vac hold-up time at 80% load adjustment range output user adjustable remote sense designated as RS+ and RS- on CN3. Total voltage compensation for cable losses with respect to the main output. (NOT available for current sharing models.) remote on/off defined RSW on CN3, requiring low signal to inhibit output. LED display (LED 1) green - the power supply is operating normally. orange - when any protection occurs or RSW is low. power good designated as PG on CN3. This signal goes high 100~500 ms after the output reaches regulation. It goes low at least 1 ms before loss of regulation. current sharing designated as CSH on CN3, optional single wired for forced surrent sharing function and parallel up to 4 units within 10% accuracy at full load. current monitor designated as CMN on CN3 for for current sense for 0.5~3 Vdc to represent 0~100% output current. % 1 20 s ms ±5 % PROTECTIONS parameter conditions/description min input under voltage protection Power supply shuts down when ac input is under 80 ±5 Vac. When ac line reappears over 86 ±5 Vac, the power supply restarts automatically. over voltage protection shutdown and latches, ac input reset required to restart over current protection auto recovery short circuit protection continuous auto recovery upon removal of short 110 cui.com typ max units 130 % 140 %Io For more information, please visit the product page. CUI Inc │ SERIES: VPM-S500-R │ DESCRIPTION: AC-DC POWER SUPPLY date 06/18/2014 │ page 3 of 5 SAFETY & COMPLIANCE parameter conditions/description isolation voltage primary to secondary at 10 mA for 3 seconds primary to transformer core at 10 mA for 3 seconds primary to earth ground for at 10 mA 3 seconds min typ max safety approvals UL 60950-1 EMI/EMC EN 55022 Class B conducted/radiated, EN 61000-3-(2,3), EN 55024, IEC 61000-4-(2,3,4,5,6,8,11) leakage current at 264 VAC grounding test allowable resistance measured when 25 A current is applied from the ground pin of the three prong plug to the farthest earthed connection point. RoHS compliant yes MTBF according to MIL-HBK-217F at 30°C 3,000 1,500 1,500 units Vac Vac Vac 2 mA 0.1 Ω 100,000 hours ENVIRONMENTAL parameter conditions/description min operating temperature derating linearly at 2.5% from 50~70°C storage temperature typ max units 0 70 °C -20 85 °C operating humidity non-condensing 5 90 %RH storage humidity non-condensing 5 95 %RH cui.com For more information, please visit the product page. CUI Inc │ SERIES: VPM-S500-R │ DESCRIPTION: AC-DC POWER SUPPLY date 06/18/2014 │ page 4 of 5 MECHANICAL parameter conditions/description dimensions 9.17 x 4.25 x 2.5 (232.92 x 107.95 x 63.5 mm) min weight typ max inch 1.45 Two sets of 8 threaded mounting holes available on the enclosure. B: 6-32, maximum insertion depth of 0.2 inches. C: M4, maximum insertion depth of 0.2 inches. Mounting holes MECHANICAL DRAWING units: inches (mm) tolerance: inches: x.xx = ±0.006 mm: x.xx = ±0.15 INPUT CONNECTOR (CN1) IEC320 or equivalent snap-in mounting type (option 1) DINKLE DT-35-A02W-03 (option 2) Suggested mating plug IEC320 powercord Suggested mating connector Molex 19198-0016 or similar LOGIC CONNECTOR (CN3) OUTPUT CONNECTOR (CN2) PIN FUNCTION Molex 26-48-1201 or similar. (option 1) Howder HD-121-8P (option 2) Suggested mating connector: Molex 09-91-2000 contact:08-50-0106 or similar. Suggested mating connector Molex 19198-0045 or similar PIN FUNCTION 1 CMN - Current Monitoring 2 CSH - Current Sharing JS B7B-XH-A Suggested mating connector JST XHP-7 or equivalent Contact: SXH-001T-P0.6 3 RTN - return FAN PG - power good signal JST B2B-XH-A Suggested mating connector JST XHP-2 or equivalent, Contact: SXH-001T-P0.6 PIN FUNCTION PIN FUNCTION 4 1~10 +Vo 1~4 +Vo 5 RSW - remote on/off 11~20 -Vo 5~8 -Vo 6 RS- - remote sense (-) 7 RS+ - remote sense (+) cui.com units kg For more information, please visit the product page. CUI Inc │ SERIES: VPM-S500-R │ DESCRIPTION: AC-DC POWER SUPPLY date 06/18/2014 │ page 5 of 5 REVISION HISTORY rev. description date 1.0 initial release 12/12/2007 1.01 new template applied, V-Infinity branding removed 08/28/2012 1.02 TUV EN 60950-1 safety removed 06/18/2014 The revision history provided is for informational purposes only and is believed to be accurate. Headquarters 20050 SW 112th Ave. Tualatin, OR 97062 800.275.4899 Fax 503.612.2383 cui.com [email protected] CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.