SERIES: VPM-S500-R│ DESCRIPTION: AC-DC POWER SUPPLY
FEATURES
• current monitoring and remote voltage adjustments (margin)
• short circuit, overload, over voltage and over temperature
protections
• optional IEC320 AC inlet or terminal block
• current sharing
RoHS
MODEL
preset
voltage
VPM-S500-03R
output
voltage1,2,3
output
current
ripple
and noise4,5
output
power6
efficiency
(Vdc)
min
(Vdc)
max
(Vdc)
max
(A)
max
(% Vp-p)
max
(W)
typ
(%)
3.3
2
3.3
80
75 mV
264
70
VPM-S500-05R
5
5
6
80
75 mV
400
75
VPM-S500-12R
12
12
15
41.67
±1
500
80
VPM-S500-18R
18
16
21
31.25
±1
500
83
VPM-S500-24R
24
22
30
22.73
±1
500
83
VPM-S500-36R
36
31
41
16.13
±1
500
83
VPM-S500-48R
48
42
55
10.42
±1
500
83
Notes:
1.
2.
3.
4.
5.
6.
customer must specify output voltage
output is fully isolated
output voltage is measured at output power connector
1% minimum load is required to maintain the ripple and regulation
Ripple & noise are measured at 20 MHz BW with 0.1 µF ceramic cap and a 22 µF electrolytic capacitors on the output
provides peak power of 900 W within 500 µs for all models
PART NUMBER KEY
VPM-S500 - XX R X
Base Number Preset Output Voltage
cui.com
Current Sharing:
“blank” = N/A
I = available
For more information, please visit the product page.
CUI Inc │ SERIES: VPM-S500-R │ DESCRIPTION: AC-DC POWER SUPPLY
date 06/18/2014 │ page 2 of 5
INPUT
parameter
conditions/description
min
voltage
frequency
max
units
90
264
Vac
47
63
Hz
8
A
70
A
max
units
current
at 90-264 Vac, full load
inrush current
at 230 Vac, full load, cold start
input fuse
Built-in ac fuse. A blown fuse usually indicates permanent
damage to the power supply serviceable by factory only.
power factor correction
at 230 Vac, full load
typ
0.98
OUTPUT
parameter
conditions/description
min
total regulation
typ
±1
transient response
output voltage returns to within 1% in less than 2.5 ms for a
50% load change. Peak transient does not exceed 5%.
overshoot
turn-on and turn-off overshoot shall not exceed 5% over
nominal voltage.
start-up time
at 230 Vac
hold-up time
at 80% load
adjustment range
output user adjustable
remote sense
designated as RS+ and RS- on CN3. Total voltage
compensation for cable losses with respect to the main output.
(NOT available for current sharing models.)
remote on/off
defined RSW on CN3, requiring low signal to inhibit output.
LED display (LED 1)
green - the power supply is operating normally.
orange - when any protection occurs or RSW is low.
power good
designated as PG on CN3. This signal goes high 100~500 ms
after the output reaches regulation. It goes low at least 1 ms
before loss of regulation.
current sharing
designated as CSH on CN3, optional single wired for forced
surrent sharing function and parallel up to 4 units within 10%
accuracy at full load.
current monitor
designated as CMN on CN3 for for current sense for 0.5~3 Vdc
to represent 0~100% output current.
%
1
20
s
ms
±5
%
PROTECTIONS
parameter
conditions/description
min
input under voltage protection
Power supply shuts down when ac input is under 80 ±5 Vac.
When ac line reappears over 86 ±5 Vac, the power supply
restarts automatically.
over voltage protection
shutdown and latches, ac input reset required to restart
over current protection
auto recovery
short circuit protection
continuous auto recovery upon removal of short
110
cui.com
typ
max
units
130
%
140
%Io
For more information, please visit the product page.
CUI Inc │ SERIES: VPM-S500-R │ DESCRIPTION: AC-DC POWER SUPPLY
date 06/18/2014 │ page 3 of 5
SAFETY & COMPLIANCE
parameter
conditions/description
isolation voltage
primary to secondary at 10 mA for 3 seconds
primary to transformer core at 10 mA for 3 seconds
primary to earth ground for at 10 mA 3 seconds
min
typ
max
safety approvals
UL 60950-1
EMI/EMC
EN 55022 Class B conducted/radiated, EN 61000-3-(2,3), EN 55024, IEC 61000-4-(2,3,4,5,6,8,11)
leakage current
at 264 VAC
grounding test
allowable resistance measured when 25 A current is applied
from the ground pin of the three prong plug to the farthest
earthed connection point.
RoHS compliant
yes
MTBF
according to MIL-HBK-217F at 30°C
3,000
1,500
1,500
units
Vac
Vac
Vac
2
mA
0.1
Ω
100,000
hours
ENVIRONMENTAL
parameter
conditions/description
min
operating temperature
derating linearly at 2.5% from 50~70°C
storage temperature
typ
max
units
0
70
°C
-20
85
°C
operating humidity
non-condensing
5
90
%RH
storage humidity
non-condensing
5
95
%RH
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: VPM-S500-R │ DESCRIPTION: AC-DC POWER SUPPLY
date 06/18/2014 │ page 4 of 5
MECHANICAL
parameter
conditions/description
dimensions
9.17 x 4.25 x 2.5 (232.92 x 107.95 x 63.5 mm)
min
weight
typ
max
inch
1.45
Two sets of 8 threaded mounting holes available on the enclosure.
B: 6-32, maximum insertion depth of 0.2 inches.
C: M4, maximum insertion depth of 0.2 inches.
Mounting holes
MECHANICAL DRAWING
units: inches (mm)
tolerance: inches: x.xx = ±0.006
mm: x.xx = ±0.15
INPUT CONNECTOR (CN1)
IEC320 or equivalent
snap-in mounting type
(option 1)
DINKLE DT-35-A02W-03
(option 2)
Suggested mating plug
IEC320 powercord
Suggested mating connector
Molex 19198-0016 or similar
LOGIC CONNECTOR (CN3)
OUTPUT CONNECTOR (CN2)
PIN FUNCTION
Molex 26-48-1201 or similar.
(option 1)
Howder HD-121-8P
(option 2)
Suggested mating connector:
Molex 09-91-2000
contact:08-50-0106 or similar.
Suggested mating connector
Molex 19198-0045 or similar
PIN
FUNCTION
1
CMN - Current Monitoring
2
CSH - Current Sharing
JS B7B-XH-A
Suggested mating connector
JST XHP-7 or equivalent
Contact: SXH-001T-P0.6
3
RTN - return
FAN
PG - power good signal
JST B2B-XH-A
Suggested mating connector
JST XHP-2 or equivalent,
Contact: SXH-001T-P0.6
PIN
FUNCTION
PIN
FUNCTION
4
1~10
+Vo
1~4
+Vo
5
RSW - remote on/off
11~20
-Vo
5~8
-Vo
6
RS- - remote sense (-)
7
RS+ - remote sense (+)
cui.com
units
kg
For more information, please visit the product page.
CUI Inc │ SERIES: VPM-S500-R │ DESCRIPTION: AC-DC POWER SUPPLY
date 06/18/2014 │ page 5 of 5
REVISION HISTORY
rev.
description
date
1.0
initial release
12/12/2007
1.01
new template applied, V-Infinity branding removed
08/28/2012
1.02
TUV EN 60950-1 safety removed
06/18/2014
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
[email protected]
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical
component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to
affect its safety or effectiveness.