0805USBN

Document 1304-1
Ultra Low Profile Common Mode Choke 0805
• For noise suppression in super high speed signal lines: USB 3.x,
HDMI 2.0, HDBaseT™, DisplayPort, DVI, etc.; and in high speed
differential signal lines: USB 2.0, IEEE1394, LVDS, etc.
• Up to 6.5 GHz differential mode 3 dB cutoff frequency; up to
35 dB common mode noise attenuation in GHz range
• Lowest profile 0805 common mode choke – 0.93 mm tall
Core material Ferrite
Environmental RoHS compliant
Terminations Matte tin over nickel over silver-platinum-glass frit.
Weight 9.0 – 13.0 mg
Ambient temperature –40°C to +125°C with Irms current.
­Maximum part temperature 140°C
Storage temperature Component: –40°C to +155°C.
Tape and reel packaging: –40°C to +80°C
Resistance to soldering heat Max three 40 second reflows at
+260°C, parts cooled to room temperature between cycles
Moisture Sensitivity Level (MSL) 1 (unlimited floor life at <30°C /
85% relative humidity)
Failures in Time (FIT) / Mean Time Between Failures (MTBF)
38 per billion hours / 26,315,789 hours, calculated per Telcordia SR-332
Packaging 2000/7″ reel; 7500/13″ reel; Plastic tape: 8 mm wide,
0.23 mm thick, 4 mm pocket spacing, 1.07 mm pocket depth
PCB washing Tested to MIL-STD-202 Method 215 plus an additional
aqueous wash. See Doc787_PCB_Washing.pdf.
Part number1
Common mode
impedance typ (Ohms)
10 MHz 100 MHz 500 MHz
0805USBN-121MR_ 2 12 57
0805USBN-271MR_ 3 27 125
0805USBN-481MR_ 5 48 231
0805USBN-701MR_ 7 70 342
0805USBN-941MR_10 94 493
0805USBN-132MR_ 13 130 697
0805USBN-162MR_ 17 165 955
0805USBN-222MR_ 24 225 1310
Common modeDCR
Inductance2
max3
attenuation typ (dB)
Isolation4 Irms5
10 MHz 100 MHz 500 MHz min (nH)
(Ohms)
(Vrms) (mA)
0.040.5 5.0
0.091.4 10.0
0.133.5 14.7
0.185.3 17.4
0.307.6 21.1
0.5010.0 24.4
0.7812.1 27.3
1.1414.0 30.0
1.When ordering, please specify packaging code:
0805USBN-222MLC
Packaging:C=7″ machine-ready reel. EIA-481 embossed plastic
tape (2000 parts per full reel).
B=Less than full reel. In tape, but not machine ready.
To have a leader and trailer added ($25 charge),
use code letter C instead.
D
=13″ machine-ready reel. EIA-481 embossed plastic tape (7500 parts per full reel).
2. Inductance measured at 100 MHz using an Agilent/HP 4286A
impedance analyzer and a Coilcraft SMD-A fixture.
3.DCR is specified per winding.
4.Winding to winding isolation (hipot) tested for one minute.
5.Current per winding that causes a 15°C rise from 25°C ambient.
5.Electrical specifications at 25°C.
Refer to Doc 362 “Soldering Surface Mount Components” before soldering.
14
30
53
77
105
140
182
252
0.087
max
2,2
0.11
0.14
0.22
0.235
0.27
0.32
0.37
0.63
250500
250500
250500
250500
250500
250 500
250 450
250 350
1
2
4
3
0.037
max
0,93
0.004
0,10
0.020 0.040
0,51 1,02
1
0.030
0,76
0.018
0,46
0.036
0,91
2
1
3
4
0.014
0,36
2
0.055 max
1,4
4
3
inches
Dimensions are in
mm
US +1-847-639-6400 [email protected]
UK +44-1236-730595 [email protected]
Taiwan +886-2-2264 3646 [email protected]
China +86-21-6218 8074 [email protected]
Singapore + 65-6484 8412 [email protected]
Recommended
Land Pattern
0.020
0,51
Document 1304-1 Revised 05/11/16
© Coilcraft Inc. 2016
This product may not be used in medical or high
risk applications without prior Coilcraft approval.
Specification subject to change without notice.
Please check web site for latest information.
Document 1304-2
Ultra Low Profile Common Mode Choke — 0805
Typical Differential Mode Attenuation (Ref: 50 Ohms)
0
1
Attenuation (dB)
2
3
4
-222
-162
-132
-941
-701
-481
-271
-121
5
6
7
8
1
10
100
1000
10,000
Frequency (MHz)
Typical Common Mode Attenuation (Ref: 50 Ohms)
0
5
Attenuation (dB)
10
15
20
-222
-162
-132
-941
-701
-481
-271
-121
25
30
35
1
10
100
1000
10,000
Frequency (MHz)
Typical Impedance vs Frequency
10000
-222
-162
-132
-941
-701
-481
-271
-121
Impedance (Ohms)
1000
100
10
1
0.1
1
10
100
1000
10,000
Frequency (MHz)
US +1-847-639-6400 [email protected]
UK +44-1236-730595 [email protected]
Taiwan +886-2-2264 3646 [email protected]
China +86-21-6218 8074 [email protected]
Singapore + 65-6484 8412 [email protected]
Document 1304-2 Revised 05/11/16
© Coilcraft Inc. 2016
This product may not be used in medical or high
risk applications without prior Coilcraft approval.
Specification subject to change without notice.
Please check web site for latest information.