DA2077-AL

Document 518
Flyback Transformer
For ON Semiconductor
NCP1027
The DA2077-AL flyback transformer has been specifically
developed for use with ON Semiconductor’s NCP1027
Standby Power Supply for ATX Applications and is specified in Application Note AND8241/D.
This transformer is designed for universal input, 85 –
265 Vac. It operates in continuous conduction mode
within an input voltage range of 120 Vdc to 375 Vdc and
at a 65 kHz switching frequency. Primary to secondary
isolation is 2000 Vrms tested for one minute.
Coilcraft can also custom engineer a transformer to meet
your specific requirements. For free evaluation samples,
contact Coilcraft or visit www.coilcraft.com.
Part
number
Inductance
Leakage
DCR max (Ohms) inductance2
at 0 A1
±10% (mH)
pri
sec
aux
max (µH)
Turns ratio
pri : sec pri : auxOutput
DA2077-AL
3.4
2.53
0.042 0.574
114
1 : 0.061 : 0.15
5 V, 2 A (sec)
12.5 V, 10 mA (aux)
1. Inductance is for the primary, measured at 10 kHz, 0.1 Vrms, 0 Adc
2. Leakage inductance tested at 100 kHz, 0.1 Vrms
3. Operating temperature range -40°C to +85°C.
4. Electrical specifications at 25°C.
1.100 max
27,94
0.950 max
24,13
10
5
Primary
Secondary
6
1
7
Auxiliary
9
0.620
15,75
0.150 ±0.030
3,81 ±0,76
6
5
0.150
3,81
Recommended
Board Layout
1
0.200
(7 places)
5,08
1.100 max
27,94
1
0.0346
0,879
10
Bottom View
0.620
15,75
0.060
1,52
US +1-847-639-6400 [email protected]
UK +44-1236-730595 [email protected]
Taiwan +886-2-2264 3646 [email protected]
China +86-21-6218 8074 [email protected]
Singapore + 65-6484 8412 [email protected]
Weight:
16.5 g
Terminations: Matte tin over copper
Packaged: 49 parts per tray
Document 518 Revised 12/02/08
© Coilcraft Inc. 2013
This product may not be used in medical or high
risk applications without prior Coilcraft approval.
Specification subject to change without notice.