JA4429-AL

Document 896-1
Flyback Transformer
For Linear Technology LT3799
Isolated LED Controller
• Developed for Linear Technology for use with their LT3799
Isolated LED Controller with active power factor correction
• Mounted on LT3799 Demo Board
• Universal input; 24 Watt output
• 3000 Vrms, one minute primary to secondary isolation;
500 Vrms, one minute primary to bias isolation
Core material Ferrite
Terminations RoHS compliant tin-silver over tin over copper. Other
terminations available at additional cost.
Weight 13.9 g
Ambient temperature –40°C to +85°C
Storage temperature Component: –40°C to +85°C.
Tray packaging: –40°C to +80°C
Moisture Sensitivity Level (MSL) 1 (unlimited floor life at <30°C /
85% relative humidity)
Failures in Time (FIT) / Mean Time Between Failures (MTBF)
38 per billion hours / 26,315,789 hours, calculated per Telcordia SR-332
Packaging 100 per tray
PCB washing Only pure water or alcohol recommended
Part
number
InductanceInductance
Leakage
at 0 A1
min at Ipk2
DCR max
inductance
±10% (µH)
(µH)
(Ohms) max (µH)3
JA4429-AL
400
340
0.252 (Pri)
0.126 (Sec)
0.149 (Bias)
(A)
Output4
1 : 0.24 1 : 0.24
1.3
24 V, 1.0 A
Dot indicates pin 1
0.680 max
17,30
7
Pri
0.110
min
2,79
Sec
2
Ipk2
7.5
1. Inductance measured at 100 kHz, 0.1 Vrms, 0 Adc using an Agilent/
HP 4263B impedance analyzer or equivalent.
2. Peak primary current drawn at minimum input voltage.
3. Leakage inductance is for the primary and is measured with the secondary shorted.
4. Output is for the secondary. Bias winding output is 24 V, 20 mA.
5. Electrical specifications at 25°C.
1
Turns ratio
Pri : Sec Pri : Bias
0.197
5,0
0.590
15,0
6
0.025
0,64
3
0.830
21,1
Bias
4
4
1
5
0.590
15,0
8
0.197
5,0
0.830 max
21,1
1
Dimensions are in
8
inches
mm
US +1-847-639-6400 [email protected]
UK +44-1236-730595 [email protected]
Taiwan +886-2-2264 3646 [email protected]
China +86-21-6218 8074 [email protected]
Singapore + 65-6484 8412 [email protected]
4
0.055
∅
1,4
5
Recommended
PC Board Layout
Document 896-1 Revised 11/11/10
© Coilcraft Inc. 2013
This product may not be used in medical or high
risk applications without prior Coilcraft approval.
Specification subject to change without notice.
Please check web site for latest information.