CDP1805AC, CDP1806AC TM CMOS 8-Bit Microprocessor with On-Chip RAM† and Counter/Timer March 1997 Features Description • Instruction Time of 3.2µs, -40oC to +85oC The CDP1805AC and CDP1806AC are functional and performance enhancements of the CDP1802 CMOS 8-bit register-oriented microprocessor series and are designed for use in general-purpose applications. • 123 Instructions - Upwards Software Compatible With CDP1802 • BCD Arithmetic Instructions • Low-Power IDLE Mode • Pin Compatible With CDP1802 Except for Terminal 16 • 64K-Byte Memory Address Capability • 64 Bytes of On-Chip RAM† • 16 x 16 Matrix of On-Board Registers • On-Chip Crystal or RC Controlled Oscillator • 8-Bit Counter/Timer The CDP1805AC hardware enhancements include a 64byte RAM and an 8-bit presettable down counter. The Counter/Timer which generates an internal interrupt request, can be programmed for use in timebase, event-counting, and pulse-duration measurement applications. The Counter/Timer underflow output can also be directed to the Q output terminal. The CDP1806AC hardware enhancements are identical to the CDP1805AC, except the CDP1806AC contains no on-chip RAM. The CDP1805AC and CDP1806AC software enhancements include 32 more instructions than the CDP1802. The 32 new software instructions add subroutine call and return capability, enhanced data transfer manipulation, Counter/Timer control, improved interrupt handling, single-instruction loop counting, and BCD arithmetic. Upwards software and hardware compatibility is maintained when substituting a CDP1805AC or CDP1806AC for other CDP1800-series microprocessors. Pinout is identical except for the replacement of VCC with ME on the CDP1805AC and the replacement of VCC with VDD on the CDP1806AC. n Ordering Information CDP1805AC CDP1805ACE CDP1805ACQ CDP1805ACD CDP1805ACDX CDP1806AC TEMPERATURE RANGE PACKAGE PKG. NO. -40oC to +85oC Plastic DIP CDP1806ACQ -40oC to +85oC PLCC N44.65 CDP1806ACD -40oC to +85oC SBDIP D40.6 CDP1806ACE CDP1806ACEX E40.6 Burn-In - Burn-In † CDP1805AC Only CAUTION: These devices are sensitive to electrostatic discharge; follow proper IC Handling Procedures. 1-888-INTERSIL or 321-724-7143 | Intersil (and design) is a trademark of Intersil Americas Inc. Copyright © Intersil Americas Inc. 2002. All Rights Reserved 1 File Number 1370.2 CDP1805AC, CDP1806AC Pinouts 38 DMA IN 4 37 DMA OUT SC1 5 36 INTERRUPT SC0 6 35 MWR MRD 7 34 TPA 6 5 4 3 2 1 44 43 42 41 40 BUS 7 8 33 TPB SC0 MRD BUS 6 9 32 MA7 BUS 7 9 BUS 5 10 31 MA6 BUS 6 10 BUS 4 11 30 MA5 BUS 5 11 BUS 3 12 29 MA4 NC 12 BUS 4 13 14 15 7 8 BUS 2 13 28 MA3 BUS 1 14 27 MA2 BUS 3 BUS 2 BUS 0 15 26 MA1 BUS 1 16 † 16 25 MA0 BUS 0 17 37 36 35 TPB 34 33 32 NC TPA MA7 MA6 MA5 MA4 MA3 MA2 MA1 MA0 EF2 EF1 EF3 EF4 NC 21 EF4 VSS 22 EF3 VSS 20 N0 23 EF2 N0 19 MWR 18 19 20 21 22 23 24 25 26 27 28 N1 24 EF1 N1 18 39 38 31 30 29 † N2 N2 17 INTERRUPT 3 Q DMA - IN DMA - OUT CLEAR XTAL 39 XTAL VDD 40 VDD 2 CLOCK NC 1 WAIT WAIT CLOCK CLEAR CDP1805AC, CDP1806AC (PLCC, PACKAGE TYPE Q) TOP VIEW SC1 Q CDP1805AC, CDP1806AC (PDIP, SBDIP) TOP VIEW † ME for CDP1805AC VDD for CDP1806AC Schematic ADDRESS BUS MA0 - MA7 MRD IN CDP1851 PIO CONTROL MA0 - MA7 CDP1805AC WITH RAM, COUNTER/TIMER CDP1806AC WITH COUNTER/TIMER MRD MWR TPA BUS0 - BUS7 BUS0 - BUS7 CDP1824 32 BYTE RAM (USED WITH CDP1806AC ONLY) CDP1833 1K BYTE ROM MWR OUT MA0-MA4 TPA ME BUS0 - BUS7 CEO CS (CDP1805AC ONLY) 8-BIT DATA BUS FIGURE 1. TYPICAL CDP1805AC, CDP1806AC SMALL MICROPROCESSOR SYSTEM 2 BUS0-BUS4 BUS 0 BUS 1 BUS 2 BUS 3 BUS 4 BUS 5 BUS 6 BUS 7 CDP1805AC ONLY 3 D (8) B (8) ALU 8-BIT COUNTER/TIMER COUNTER HOLDING REGISTER (CH) 64-BYTE RAM ME FOR CDP1805AC VDD FOR CDP1806AC DF (1) CLK FIGURE 2. BLOCK DIAGRAM FOR CDP1805AC AND CDP1806AC A (16) R(E).1 R(E).0 R(F).1 R(F).0 R(9).1 R(9).0 R(A).1 R(A).0 R(0).1 R(0).0 R(1).1 R(1).0 R(2).1 R(2).0 ÷ 32 LATCH AND DECODE T (8) CONTROL I (4) TC INSTRUCTION DECODE CLEAR WAIT P (4) CONTROL AND TIMING LOGIC CLOCK LOGIC DMA OUT DMA IN INT I/O REQUESTS X (4) INTERRUPT LOGIC EF1 EF2 TPA REGISTER ARRAY R 8-BIT BIDIRECTIONAL DATA BUS INCR/ DECR MODE CONTROL EF1 EF3 EF2 EF4 MA7 MA5 MA3 MA1 MA6 MA4 MA2 MA0 MUX I/O FLAGS MEMORY ADDRESS LINES N (4) N0 N1 N2 I/O COMMANDS XTAL SCO STATE CODES SCI Q LOGIC TPA TPB SYSTEM TIMING MWR MRD CLOCK CDP1805AC, CDP1806AC CDP1805AC, CDP1806AC Absolute Maximum Ratings Thermal Information DC Supply Voltage Range, (VDD) (All Voltages Referenced to VSS Terminal). . . . . . . . . -0.5V to +7V Input Voltage Range, All Inputs . . . . . . . . . . . . . -0.5V to VDD +0.5V DC Input Current, any One Input . . . . . . . . . . . . . . . . . . . . . . . . . ±10mA Thermal Resistance (Typical, Note 2) θJA (oC/W) θJC (oC/W) PDIP Package . . . . . . . . . . . . . . . . . . . 50 N/A PLCC Package . . . . . . . . . . . . . . . . . . 46 N/A SBDIP Package. . . . . . . . . . . . . . . . . . 55 15 Device Dissipation Per Output Transistor TA = Full Package Temperature Range . . . . . . . . . . . . . . 100mW Operating Temperature Range (TA) Package Type D . . . . . . . . . . . . . . . . . . . . . . . . .-55oC to +125oC Package Type E and Q . . . . . . . . . . . . . . . . . . . . .-40oC to +85oC Storage Temperature Range (TSTG). . . . . . . . . . . .-65oC to +150oC Lead Temperature (During Soldering) At Distance 1/16 ±1/32in (1.59 ± 0.79mm) from case for 10s Max . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +265oC Printed Circuit Board Mount: 57mm x 57mm Minimum Area x 1.6mm Thick G10 Epoxy Glass, or Equivalent. CAUTION: Stresses above those listed in “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress only rating and operation of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied. Recommended Operating Conditions TA = Full-Package Temperature Range. For maximum reliability, operating conditions should be selected so that operation is always within the following ranges. CDP1805ACD, CDP1805ACE CDP1806ACD, CDP1806ACE TEST CONDITIONS VDD (V) PARAMETER MIN MAX UNITS DC Operating Voltage Range - 4 6.5 V Input Voltage Range - VSS VDD V Minimum Instruction Time (Note 1) (fCL = 5MHz) 5 3.2 - µs Maximum DMA Transfer Rate 5 - 0.625 Mbyte/s Maximum Clock Input Frequency, Load Capacitance (CL) = 50pF 5 DC 5 MHz Maximum External Counter/Timer Clock Input Frequency to EF1, EF2 5 DC 2 MHz NOTES: 1. Equals 2 machine cycles - one Fetch and one Execute operation for all instructions except Long Branch, Long Skip, NOP, and “68” family instructions, which are more than two cycles. 2. θJA is measured with the component mounted on an evaluation PC board in free air. Static Electrical Specifications at TA = -40oC to +85oC, VDD ±5%, Except as Noted CDP1805ACD, CDP1805ACE CDP1806ACD, CDP1806ACE VO (V) VIN (V) VDD (V) MIN (NOTE 3) TYP MAX UNITS - 0, 5 5 - 50 200 µA 0.4 0, 5 5 1.6 4 - mA 0.4 5 5 0.2 0.4 - mA 4.6 0, 5 5 -1.6 -4 - mA 4.6 0 5 -0.1 -0.2 - mA Output Voltage Low Level, VOL - 0, 5 5 - 0 0.1 V Output Voltage High Level, VOH - 0, 5 5 4.9 5 - V PARAMETER Quiescent Device Current, IDD Output Low Drive (Sink) Current, (Except XTAL), IOL XTAL Output, IOL Output High Drive (Source) Current (Except XTAL, IOH XTAL, IOH 4 CDP1805AC, CDP1806AC Static Electrical Specifications at TA = -40oC to +85oC, VDD ±5%, Except as Noted (Continued) CDP1805ACD, CDP1805ACE CDP1806ACD, CDP1806ACE VO (V) VIN (V) VDD (V) MIN (NOTE 3) TYP MAX UNITS Input Low Voltage (BUS0 - BUS7, ME), VIL 0.5, 4.5 - 5 - - 1.5 V Input High Voltage (BUS0 - BUS7, ME), VIH 0.5, 4.5 - 5 3.5 - - V Positive Trigger Threshold, VP 0.5, 4.5 - 5 2.2 2.9 3.6 V Negative Trigger Threshold, VN 0.5, 4.5 - 5 0.9 1.9 2.8 V Hysteresis, VH 0.5, 4.5 - 5 0.3 0.9 1.6 V - 0, 5 5 - ±0.1 ±5 µA 0, 5 0, 5 5 - ±0.2 ±5 µA Input Capacitance, CIN - - - - 5 7.5 pF Output Capacitance, COUT - - - - 10 15 pF Run - - 5 - 35 50 mW Idle “00” at M (0000) - - 5 - 12 18 mW PARAMETER Schmitt Trigger Input Voltage (Except BUS0 - BUS7, ME) Input Leakage Current, IIN Three-State Output Leakage Current, IOUT Total Power Dissipation (Note 4) Minimum Data Retention Voltage, VDR VDD = VDR - 2 2.4 V Data Retention Current, IDR VDD = 2.4 - 25 100 µA NOTES: 3. Typical values are for TA = +25oC and nominal VDD. 4. External clock: f = 5MHz, t R, t F = 10ns; C L = 50pF. Dynamic Electrical Specifications at TA = -40o to +85oC; C L = 50pF; Input t R, t F = 10ns; Input Pulse Levels = 0.1V to V DD -0.1V; V DD = 5V, ±5%. CDP1805AC CDP1806AC (NOTE 5) TYP MAX UNITS Clock to TPA, TPB, tPLH, tPHL 150 275 ns Clock-to-Memory High-Address Byte, tPLH, tPHL 325 550 ns Clock-to-Memory Low-Address Byte, tPLH, tPHL 275 450 ns Clock to MRD, tPLH, tPHL 200 325 ns Clock to MWR, tPLH, tPHL (See Note 5) 150 275 ns Clock to (CPU DATA to BUS), tPLH, tPHL 375 625 ns Clock to State Code, tPLH, tPHL 225 400 ns Clock to Q, tPLH, tPHL 250 425 ns Clock to N, tPLH, tPHL 250 425 ns Clock to Internal RAM Data to BUS, tPLH, tPHL 420 650 ns PARAMETER Propagation Delay Times 5 CDP1805AC, CDP1806AC Dynamic Electrical Specifications at TA = -40o to +85oC; C L = 50pF; Input t R, t F = 10ns; Input Pulse Levels = 0.1V to V DD -0.1V; V DD = 5V, ±5%. (Continued) CDP1805AC CDP1806AC (NOTE 5) TYP MAX UNITS Data Bus Input Set-Up, tSU -100 0 ns Data Bus Input Hold, tH 125 225 ns DMA Set-Up, tSU -75 0 ns DMA Hold, tH 100 175 ns ME Set-Up, t 125 320 ns 0 50 ns Interrupt Set-Up, tSU -100 0 ns Interrupt Hold, tH 100 175 ns WAIT Set-Up, tSU 20 50 ns EF1-4 Set-Up, tSU -125 0 ns EF1 -4 Hold, tH 175 300 ns CLEAR Pulse Width, tWL 100 175 ns CLOCK Pulse Width, tW 75 100 ns PARAMETER Minimum Set-Up And Hold Times (Note 2) SU ME Hold, tH Minimum Pulse Width Times (Note 6) NOTES: 5. Typical values are for TA = 25o C and nominal VDD. 6. Maximum limits of minimum characteristics are the values above which all devices function. Timing Specifications as a function of T (T = 1/fCLOCK) at TA = -40 to +85oC, VDD = 5V, ±15% CDP1805AC, CDP1806AC PARAMETER TYP (NOTE 7) MAX UNITS 2T-275 2T -175 ns T/2 -100 T/2 -75 ns T/2 +75 T/2 +100 ns T +180 T +240 ns T +110 T +150 ns 4.5T -440 4.5T -330 ns High-Order Memory-Address Byte Set-Up to TPA MRD to TPA Time, tSU Time, tSU High-Order Memory-Address Byte Hold after TPA Time, tH Low-Order Memory-Address Byte Hold after WR Time, tH CPU Data to Bus Hold after WR Time, tH Required Memory Access Time, tACC Address to Data NOTE: 7. Typical values are for TA = +25oC and nominal VDD. 6 CDP1805AC, CDP1806AC Timing Waveforms For Possible Operating Modes INTERNAL RAM READ CYCLE 00 10 20 30 40 50 INTERNAL RAM WRITE CYCLE 60 70 00 10 20 30 40 50 60 70 CLOCK 01 11 21 31 41 51 61 71 01 11 21 31 41 51 61 71 TPA TPB MEMORY ADDRESS HIGH BYTE LOW BYTE HIGH BYTE LOW BYTE MRD MWR †ME IN VALID DATA FROM MEMORY DATA BUS VALID DATA FROM CPU NOTE: 8. ME has a minimum setup and hold time with respect to the beginning of clock 70. For a memory read operation, RAM data will appear on the data bus during the time ME is active after clock 31. The time shown can be longer, if for instance, a DMA out operation is performed on internal RAM data, to allow data enough time to be latched into an external device. The internal RAM is automatically deselected at the end of clock 71 independent of ME. † For CDP1805AC only. FIGURE 3. INTERNAL MEMORY OPERATION TIMING WAVEFORMS EXTERNAL MEMORY READ CYCLE 00 10 20 30 40 50 EXTERNAL MEMORY WRITE CYCLE 60 70 00 10 20 30 40 50 60 70 CLOCK 01 11 21 31 41 51 61 71 01 11 21 31 41 51 TPA TPB MEMORY ADDRESS HIGH BYTE LOW BYTE HIGH BYTE LOW BYTE MRD MWR †ME IN (HIGH) DATA BUS DATA LATCHED IN CPU VALID DATA FROM CPU NOTE: † For CDP1805AC only. FIGURE 4. EXTERNAL MEMORY OPERATION TIMING WAVEFORMS 7 61 71 CDP1805AC, CDP1806AC tW CLOCK 00 0 1 01 10 2 11 20 tPLH 3 21 30 4 31 40 5 41 50 6 51 7 60 61 70 0 71 00 01 tPHL TPA MEMORY ADDRESS MRD (MEMORY READ CYCLE) tPLH tPLH, tPHL TPB tSU tPLH, tPHL tPHL tH tH LOW ORDER ADDRESS BYTE HIGH ORDER ADDRESS BYTE tSU tPLH tPHL tPHL tPLH MWR (MEMORY WRITE CYCLE) tPHL † ME (MEMORY ENABLE) tSU tSU IS ALLOWABLE INTERNAL RAM ACCESS TIME †† EMS (EXTERNAL MEMORY SELECT) tH tPLH tPHL tH tPLH, tPHL DATA FROM CPU TO BUS DATA FROM INTERNAL MEMORY TO BUS (ME = LOW) tPLH tPHL tPLH, tPLH tPLH, tPHL tPLH, tPHL STATE CODES tPLH, tPHL Q N0, N1, N2 (I/O EXECUTION CYCLE) tPHL tPLH DATA LATCHED IN CPU tSU tH DATA FROM BUS TO CPU DMA SAMPLED (S1, S2, S3) DMA REQUEST INTERRUPT SAMPLED (S1, S2) INTERRUPT REQUEST tSU tH tSU tH FLAG LINES SAMPLED END OF S0 EF1 - EF4 tSU tSU tH tSU tH WAIT tWL CLEAR NOTES: † This Timing Diagram is used to show signal relationships only, and does not represent any specific machine cycle. † All measurements are referenced to 50% point of the wave forms. † Shaded areas indicate “don’t care” or undefined state. Multiple transitions may occur during this period. † For the run (RAM only) mode only. †† For the run (RAM/ROM) mode only. FIGURE 5. TIMING WAVEFORMS 8 tH CDP1805AC, CDP1806AC Enhanced CDP1805AC and CDP1806AC Operation MRD = VDD: Input data from I/O to CPU and memory. Timing EF1 to EF4 (4 Flags) Timing for the CDP1805AC and CDP1806AC is the same as the CDP1802 microprocessor series, with the following exceptions: These inputs enable the I/O controllers to transfer status information to the processor. The levels can be tested by the conditional branch instructions. They can be used in conjunction with the INTERRUPT request line to establish interrupt priorities. The flag(s) are sampled at the end of every S0 cycle. EF1 and EF2 are also used for event counting and pulse width measurement in conjunction with the Counter/Timer. MRD = VSS: Output data from Memory to I/O. • 4.5 Clock Cycles Are Provided for Memory Access Instead of 5. • Q Changes 1/2 Clock Cycle Earlier During the SEQ and REQ Instructions. • Flag Lines (EF1-EF4) Are Sampled at the End of the S0 Cycle Instead of at the Beginning of the S1 Cycle. INTERRUPT, DMA-IN, DMA-OUT (3 I/O Requests) DMA-lN and DMA-OUT are sampled during TPB every S1, S2, and S3 cycle. INTERRUPT is sampled during TPB every S1 and S2 cycle. • Pause Can Only Occur on the Low-To-High Transition of Either TPA or TPB, Instead of any Negative Clock Transition. Interrupt Action - X and P are stored in T after executing current instruction; designator X is set to 2; designator P is set to 1; interrupt enable (MIE) is reset to 0 (inhibit); and instruction execution is resumed. The interrupt action requires one machine cycle (S3). Special Features Schmitt triggers are provided on all inputs, except ME and BUS 0-BUS 7, for maximum immunity from noise and slow signal transitions. A Schmitt Trigger in the oscillator section allows operation with an RC or crystal. DMA Action - Finish executing current instruction; R(0) points to memory area for data transfer; data is loaded into or read out of memory; and R(0) is incremented. The CDP1802 Series LOAD mode is not retained. This mode (WAIT, CLEAR = 0) is not allowed on the CDP1805AC and CDP1806AC. NOTE: In the event of concurrent DMA and INTERRUPT requests, DMA-IN has priority followed by DMA-OUT and then INTERRUPT. (The interrupt request is not internally latched and must be held true after DMA). A low power mode is provided, which is initiated via the IDLE instruction. In this mode all external signals, except the oscillator, are stopped on the low-to-high transition of TPB. All outputs remain in their previous states, MRD is set to a logic “1”, and the data bus floats. The IDLE mode is exited by a DMA or INT condition. The INT includes both external interrupts and interrupts generated by the Counter/Timer. The only restrictions are that the Timer mode, which uses the TPA ÷ 32 clock source, and the underflow condition of the Pulse Width Measurement modes are not available to exit the IDLE mode. SC0, SC1, (2 State Code Lines) These outputs indicate that the CPU is: 1) fetching an instruction, or 2) executing an instruction, or 3) processing a DMA request, or 4) acknowledging an interrupt request. The levels of state code are tabulated below. All states are valid at TPA. STATE CODE LINES STATE TYPE Signal Descriptions SC1 SC0 S0 (Fetch) L L S1 (Execute) L H S2 (DMA) H L S3 (Interrupt) H H Bus 0 to Bus 7 (Data Bus) 8-Bit bidirectional DATA BUS lines. These lines are used for transferring data between the memory, the microprocessor, and I/O devices. N0 to N2 (I/O) Lines NOTE: H = VDD, L = VSS. Activated by an I/O instruction to signal the I/O control logic of a data transfer between memory and I/O interface. These lines can be used to issue command codes or device selection codes to the I/O devices. The N-bits are low at all times except when an I/O instruction is being executed. During this time their state is the same as the corresponding bits in the N Register. The direction of data flow is defined in the I/O instruction by bit N3 (internally) and is indicated by the level of the MRD Signal: TPA, TPB (2 Timing Pulses) Positive pulses that occurrence in each machine cycle (TPB follows TPA). They are used by I/O controllers to interpret codes and to time interaction with the data bus. The trailing edge of TPA is used by the memory system to latch the highorder byte of the multiplexed 16-bit memory address. 9 CDP1805AC, CDP1806AC MA0 to MA7 (8 Memory Address Lines) ME (Memory Enable CDP1805AC Only) In each cycle, the higher-order byte of a 16-bit memory address appears on the memory address lines MA0-7 first. Those bits required by the memory system can be strobed into external address latches by timing pulse TPA. The loworder byte of the 16-bit address appears on the address lines 1/2 clock after the termination of TPA. This active low input is used to select or deselect the internal RAM. It must be active prior to clock 70 for an internal RAM access to take place. Internal RAM data will appear on the data bus during the time that ME is active (after clock 31). Thus, if this data is to be latched into an external device (i.e., during an OUTPUT instruction or DMA OUT cycle), ME should be wide enough to provide enough time for valid data to be latched. The internal RAM is automatically deselected after clock 71. ME is ineffective when MRD • MWR = 1. MWR (Write Pulse) A negative pulse appearing in a memory-write cycle, after the address lines have stabilized. The internal RAM is not internally mask-decoded. Decoding of the starting address is performed externally, and may reside in any 64-byte block of memory. MRD (Read Level) A low level on MRD indicates a memory read cycle. It can be used to control three-state outputs from the addressed memory and to indicate the direction of data transfer during an I/O instruction. VDD (CDP1806AC Only) This input replaces the ME signal of the CDP1805AC and must be connected to the positive power supply. Q VDD, VSS, (Power Levels) Single bit output from the CPU which can be set or reset, under program control. During SEQ and REQ instruction execution, Q is set or reset between the trailing edge of TPA and the leading edge of TPB. The Q line can also be controlled by the Counter/Timer underflow via the Enable Toggle Q instruction. VSS is the most negative supply voltage terminal and is normally connected to ground. VDD is the positive supply voltage terminal. All outputs swing from VSS to VDD. The recommended input voltage swing is from VSS to VDD. Architecture The Enable Toggle Q command connects the Q-line flip-flop to the output of the counter, such that each time the counter decrements from 01 to its next value, the Q line changes state. This command is cleared by a LOAD COUNTER (LDC) instruction with the Counter/Timer stopped, a CPU reset, or a BRANCH COUNTER INTERRUPT (BCl) instruction with the counter interrupt flip-flop set. Figure 2 shows a block diagram of the CDP1805AC and CDP1806AC. The principal feature of this system is a register array (R) consisting of sixteen 16-bit scratchpad registers. Individual registers in the array (R) are designated (selected) by a 4-bit binary code from one of the 4-bit registers labeled N, P, and X. The contents of any register can be directed to any one of the following paths: Clock 1. The external memory (multiplexed, higher-order byte first on to 8 memory address lines). Input for externally generated single-phase clock. The maximum clock frequency is 5MHz at VDD = 5V. The clock is counted down internally to 8 clock pulses per machine cycle. 2. The D register (either of the two bytes can be gated to D). 3. The increment/decrement circuit where it is increased or decreased by one and stored back in the selected 16-bit register. XTAL Connection to be used with clock input terminal, for an external crystal, if the on-chip oscillator is utilized. 4. To any other 16-bit scratch pad register in the array. The four paths, depending on the nature of the instruction, may operate independently or in various combinations in the same machine cycle. WAIT, CLEAR (2 Control Lines) Provide four control modes as listed in the following truth table: CLEAR WAIT MODE L L Not Allowed L H Reset H L Pause H H Run Most instructions consist of two 8-clock-pulse machine cycles. The first cycle is the fetch cycle, and the second, and more if necessary, are execute cycles. During the fetch cycle the four bits in the P designator select one of the 16 registers R(P) as the current program counter. The selected register R(P) contains the address of the memory location from which the instruction is to be fetched. When the instruction is read out from the memory, the higher order 4 bits of the instruction byte are loaded into the register and the lower order 4 bits into the N register. The content of the program counter is automatically incremented by one so that R(P) is now “pointing” to the next byte in the memory. 10 CDP1805AC, CDP1806AC Another important use of R as a data pointer supports the built-in Direct-Memory-Access (DMA) function. When a DMA-ln or DMA-Out request is received, one machine cycle is “stolen”. This operation occurs at the end of the execute machine cycle in the current instruction. Register R(0) is always used as the data pointer during the DMA operation. The data is read from (DMA-Out) or written into (DMA-ln) the memory location pointed to by the R(0) register. At the end of the transfer, R(0) is incremented by one so that the processor is ready to act upon the next DMA byte transfer request. This feature in the CDP1805AC and CDP1806AC architecture saves a substantial amount of logic when fast exchanges of blocks of data are required, such as with magnetic discs or during CRT-display-refresh cycles. The X designator selects one of the 16 registers R(X) to “point” to the memory for an operand (or data) in certain ALU or I/O operations. The N designator can perform the following five functions depending on the type of instruction fetched: 1. Designate one of the 16 registers in R to be acted upon during register operations. 2. Indicate to the I/O devices a command code or deviceselection code for peripherals. 3. Indicate the specific operation to be executed during the ALU instructions, types of tests to be performed during the Branch instructions, or the specific operation required in a class of miscellaneous instructions. Data Registers 4. Indicate the value to be loaded into P to designate a new register to be used as the program counter R(P). When registers in R are used to store bytes of data, instructions are provided which allow D to receive from or write into either the higher-order- or lower-order-byte portions of the register designated by N. By this mechanism (together with loading by data immediate) program pointer and data pointer designations are initialized. Also, this technique allows scratchpad registers in R to be used to hold general data. By employing increment or decrement instructions, such registers may be used as loop counters. The new RLDl, RLXA, RSXD, and RNX instructions also allow loading, storing, and exchanging the full 16-Bit contents of the R registers without affecting the D register. The new DBNZ instruction allows decrementing and branching-on-not-zero of any 16-Bit R register also without affecting the D register. 5. Indicate the value to be loaded into X to designate a new register to be used as data pointer R(X). The registers in R can be assigned by a programmer in three different ways as program counters, as data pointers, or as scratchpad locations (data registers) to hold two bytes of data. Program Counters Any register can be the main program counter; the address of the selected register is held in the P designator. Other registers in R can be used as subroutine program counters. By a single instruction the contents of the P register can be changed to effect a “call” to subroutine. When interrupts are being serviced, register R(1) is used as the program counter for the user's interrupt servicing routine. After reset, and during a DMA operation, R(0) is used as the program counter. At all other times the register designated as program counter is at the discretion of the user. The Q Flip-Flop An internal flip-flop, Q, can be set or reset by instruction and can be sensed by conditional branch instructions. It can also be driven by the underflow output of the counter/timer The output of Q is also available as a microprocessor output. REGISTER SUMMARY Data Pointers The registers in R may be used as data pointers to indicate a location in memory. The register designated by X (i.e., R(X)) points to memory for the following instructions (see Table 1): 1. ALU operations. 2. Output instructions. D 8 Bits Data Register (Accumulator) DF 1-Bit Data Flag (ALU Carry) B 8 Bits Auxiliary Holding Register R 16 Bits 1 of 16 Scratch and Registers P 4 Bits Designates which Register is Program Counter 3. Input instructions. X 4 Bits Designates which Register is Data Pointer 4. Register to memory transfer. N 4 Bits Holds Low-Order Instr. Digit 5. Memory to register transfer. I 4 Bits Holds High-Order Instr. Digit 6. Interrupt and subroutine handling. T 8 Bits Holds old X, P after Interrupt (X is high nibble) The register designated by N (i.e., R(N)) points to memory for the “load D from memory” instructions ON and 4N and the “Store D” instruction 5N. The register designated by P (i.e., the program counter) is used as the data pointer for ALU instructions F8-FD, FF, 7C, 7D, 7F, and the RLDl instruction 68CN. During these instruction executions, the operation is referred to as “data immediate”. 11 Q 1-Bit CNTR 8-Bits Counter/Timer Output Flip-Flop CH 8 Bits Holds Counter Jam Value MIE 1-Bit Master Interrupt Enable ClE 1-Bit Counter Interrupt Enable XlE 1-Bit External Interrupt Enable ClL 1-Bit Counter Interrupt Latch CDP1805AC, CDP1806AC Interrupt Servicing latched counter interrupt request signal will be reset when the branch is taken, when the CPU is reset, or with a LDC instruction with the Counter stopped. Note, that exiting a counter-initiated interrupt routine without resetting the counter-interrupt latch will result in immediately reentering the interrupt routine. Register R(1) is always used as the program counter whenever interrupt servicing is initialized. When an interrupt request occurs and the interrupt is allowed by the program (again, nothing takes place until the completion of the current instruction), the contents of the X and P registers are stored in the temporary Register T, and X and P are set to new values; hex digit 2 in X and hex digit 1 in P. Master Interrupt Enable is automatically deactivated to inhibit further interrupts. The user’s interrupt routine is now in control; the contents of T may be saved by means of a single SAV instruction (78) in the memory location pointed to by R(X) or the contents of T, D, and DF may be saved using a single DSAV instruction (6876). At the conclusion of the interrupt, the user's routine may restore the pre-interrupted value of X and P with either a RET instruction (70) which permits further interrupts, or a DlS instruction (71), which disables further interrupts. Counter/Timer and Controls (See Figure 7) This logic consists of a presettable 8-Bit down-counter (Modulo N type), and a conditional divide-by-32 prescaler. After counting down to (01)16the counter returns to its initial value at the next count and sets the Counter Interrupt Latch. It will continue decrementing on subsequent counts. If the counter is preset to (00)16 full 256 counts will occur. During a Load Counter instruction (LDC) if the counter was stopped with a STPC Instruction, the counter and its holding register (CH) are loaded with the value in the D Register and any previous counter interrupt is cleared. If the LDC is executed when the counter is running, the contents of the D Register are loaded into the holding register (CH) only and any previous counter interrupt is not cleared. (LDC RESETS the Counter Interrupt Latch only when the Counter is stopped). After counting down to (01)16 the next count will load the new initial value into the counter, set the Counter Interrupt Latch, and operation will continue. Interrupt Generation and Arbitration (See Figure 6) Interrupt requests can be generated from the following sources: 1. Externally through the interrupt input (request not latched). 2. Internally due to Counter/Timer response (request is latched). a. On the transition from count (01)16 to its next value (counter underflow). b. On the mode 1. transition of EF1 in pulse measurement c. On the mode 2. transition of EF2 in pulse measurement For an interrupt to be serviced by the CPU, the appropriate Interrupt Enable flip-flops must be set. Thus, the External Interrupt Enable flip-flop must be set to service an external interrupt request, and the Counter Interrupt Enable flip-flop must be set to service an internal Counter/Timer interrupt request. In addition, the Master interrupt Enable flip-flop (as used in the CDP1802) must be set to service either type of request. All 3 flip-flops are initially enabled with the application of a hardware reset, and, can be selectively enabled or disabled with software: ClE, ClD instructions for the ClE flipflop; XlE, XlD instructions for the XIE flip-flop; RET, DIS instructions for the MIE flip flop. Short branch instructions on Counter Interrupt (BCI) and External Interrupt (BXl) can be placed in the user's interrupt service routine to provide a means of identifying and prioritizing the interrupt source. Note, however, that since the External Interrupt request is not latched, it must remain active until the short branch is executed if this priority arbitration scheme is used. Interrupt requests can also be polled if automatic interrupt service is not desired (MlE = 0). With the Counter Interrupt and External Interrupt short branch instructions, the branch will be taken if an interrupt request is pending, regardless of the state of any of the 3 Interrupt Enable flip-flops. The 12 CDP1805AC, CDP1806AC RET RESET S3 MASTER Q INTERRUPT ENABLE FF R (MIE) S DIS MIE COUNTER UNDERFLOW S PULSE MODE EF1 PULSE MODE EF2 BCI CIE RESET CID S COUNTER INTERRUPT ENABLE FF R Q (CIE) R RESET LDC • COUNTER STOPPED RESET XID CI INTERRUPT XI EXTERNAL INT XIE TO BRANCH LOGIC (BCI) Q COUNTER INTERRUPT LATCH (CIL) TO BRANCH LOGIC (BXI) REQUESTS EXTERNAL Q INTERRUPT ENABLE FF R (XIE) S FIGURE 6. INTERRUPT LOGIC CONTROL DIAGRAM The Counter/Timer has the following five programmable modes: The modes can be changed without affecting the stored count. 1. Event Counter 1: Input to counter is connected to the EF1 terminal. The high-to-low transition decrements the counter. Those modes which use EF1 and EF2 terminals as inputs do not exclude testing these flags for branch instructions. 2. Event Counter 2: Input to counter is connected to the EF2 terminal. The high-to-low transition decrements the counter. The Stop Counter (STPC) instruction clears the counter mode and stops counting. The STPC instruction should be executed prior to a GEC instruction, if the counter is in the Event Counter Mode 1 or 2. 3. Timer: Input to counter is from the divide by 32 prescaler clocked by TPA. The prescaler is decremented on the low-to-high transition of TPA. The divide by 32 prescaler is reset when the counter is in a mode other than the Timer mode, system RESET, or stopped by a STPC. In addition to the five programmable modes, the Decrement Counter instruction (DTC) enables the user to count in software. In order to avoid conflict with counting done in the other modes, the instruction should be used only after the mode has been cleared by a Stop Counter instruction. 4. Pulse Duration Measurement 1: Input to counter connected to TPA. Each low-to-high transition of TPA decrements the counter if the input signal at EF1 terminal (gate input) is low. On the transition of EF1 to the positive state, the count is stopped, the mode is cleared, and the interrupt request latched. If the counter underflows while the input is low, interrupt will also be set, but counting will continue. The Enable Toggle Q instruction (ETQ) connects the Q-line flip-flop to the output of the counter, such that each time the counter decrements from 01 to its next value, the Q output changes state. This action is independent of the counter mode and the Interrupt Enable flip-flops. The Enable Toggle Q condition is cleared by an LDC with the Counter/Timer stopped, system Reset, or a BCl with Cl = 1. NOTE: SEQ and REQ instructions are independent of ETQ, they can SET or RESET Q while the Counter is running. 5. Pulse Duration Measurement 2: Operation is identical to Pulse Duration Measurement 1, except EF2 is used as the gate input. On-Board Clock (See Figure 8, Figure 9 and Figure 10) Clock circuits may use either an external crystal or an RC network. A typical crystal oscillator circuit is shown in Figure 8. The crystal is connected between terminals 1 and 39 (CLOCK and XTAL) in parallel with a resistance, RF (1mΩ typ). Frequency trimming capacitors, CIN and COUT, may be required at terminals 1 and 39. For additional information on crystal oscillators, see lCAN-6565. 13 CDP1805AC, CDP1806AC STPC STM R ÷ 32 TPA TO INTERRUPT LATCH INH OUT SPMI COUNTER UNDERFLOW Q ETQ 8-BIT DOWN COUNTER EF1 Q OUTPUT C Q FF D Q LDC LOAD SCMI READ EF2 SPM2 SCM2 DTC GEC FIGURE 7. TIMER/COUNTER DIAGRAM Because of the Schmitt Trigger input, an RC oscillator can be used as shown in Figure 9. The frequency is approximately 1/RC (see Figure 10). VDD = 5V AT 25oC 10M C RF R (Ω) C 1MΩ 1M C C CLOCK† 1 = 100K 39 XTAL † 1µ C = 0. 1µ F = 0 .0 1µ = F = 10 00 pF 10 0p F pF 10K XTAL CIN 15pF 5MHz PARALLEL RESONANT CRYSTAL COUT 27pF 1 10 100 1K 10K 100K 1M FREQUENCY (Hz) FIGURE 10. NOMINAL COMPONENT VALUES AS A FUNCTION OF FREQUENCY FOR THE RC OSCILLATOR †Pin numbers refer to 40 pin DIP. FIGURE 8. TYPICAL 5MHz CRYSTAL OSCILLATOR CONTROL MODES R CLOCK† 1 39 XTAL † C †Pin numbers refer to 40 pin DIP. FIGURE 9. RC NETWORK FOR OSCILLATOR 14 CLEAR WAIT MODE L L Not Allowed L H Reset H L Pause H H Run CDP1805AC, CDP1806AC The function of the modes are defined as follows: Power-up Reset/Run Circuit Reset Power-up Reset/Run can be realized with the circuit shown in Figure 11. VDD The levels on the CDP1805A and CDP1806A external signal lines will asynchronously be forced by RESET to the following states: Q=0 MRD = 1 TPB = 0 CDP1805AC CDP1806AC SC1, SC0 = 0,1 BUS 0-7 = 0 (EXECUTE) MA0-7 = RO.1 N0, N1, N2 = 0, 0, 0 TPA = 0 MWR = 1 RP WAIT RX CLEAR THE RC TIME CONSTANT SHOULD BE GREATER THAN THE OSCILLATOR START-UP TIME (TYPICALLY 20ms) Internal Changes Caused By RESET are: CX l, N Instruction Register is cleared to 00. XlE and CIE are set to allow interrupts following initialize. ClL is cleared (any pending counter interrupt is cleared), counter is stopped, the counter mode is cleared, and ETQ is disabled. FIGURE 11. RESET/RUN DIAGRAM Initialization Cycle Pause The first machine cycle following termination of RESET is an initialization cycle which requires 9 clock pulses. During this cycle the CPU remains in S1 and the following additional changes occur: Pause is a low power mode which stops the internal CPU timing generator and freezes the state of the processor. The CPU may be held in the Pause mode indefinitely. Hardware pause can occur at two points in a machine cycle, on the low-to-high transition of either TPA or TPB. A TPB pause can also be initiated by software with the execution of an IDLE instruction. In the pause mode, the oscillator continues to run but subsequent clock transitions are ignored. TPA and TPB remain at their previous state (see Figure 12). 1 → MlE X, P → T (The old value of X, P will be put into T. This only has meaning following an orderly Reset with power applied). X, P, RO ← 0 (X, P, and RO are cleared). Pause is entered from RUN by dropping WAIT low. Appropriate Setup and Hold times must be met. Interrupt and DMA servicing is suppressed during the initialization cycle. The next cycle is an S0 or an S2 but never an S1 or S3.The use of a 71 instruction followed by 00 at memory locations 0000 and 0001, may be used to reset MIE so as to preclude interrupts until ready for them. If Pause is entered while in the event counter mode, the appropriate Flag transition will continue to decrement the counter. Hardware-initiated pause is exited to RUN by raising the Wait line high. Pause entered with an IDLE instruction requires DMA, INTERRUPT or RESET to resume execution. Reset and Initialize Do Not Affect: D (Accumulator) DF R1, R2, R3, R4, R5, R6, R7, R8, R9, FA, RB, RC, RD, RE, RF CH (Counter Holding Register) Counter (the counter is stopped but the value is unaffected) Run May be initiated from the Pause or Reset mode functions. If initiated from Pause, the CPU resumes operation at the point it left off. If paused at TPA, it will resume on the next high-to-low clock transition, while if paused at TPB, it will resume on the next low-to-high clock transition (see Figure 12). When initiated from the Reset operation, the first machine cycle following Reset is always the initialization cycle. The initialization cycle is then followed by a DMA (S2) cycle or fetch (S0) from location 0000 in memory. Schmitt Trigger Inputs All inputs except BUS 0-BUS 7 and ME contain a Schmitt Trigger circuit, which is especially useful on the CLEAR input as a power-up RESET (see Figure 11) and the CLOCK input (see Figure 8 and Figure 9). 15 CDP1805AC, CDP1806AC State Transitions The CDP1805A and CDP1806A state transitions are shown in Figure 13. Each machine cycle requires the same period of time, 8 clock pulses, except the initialization cycle (INlT) which requires 9 clock pulses. Reset is asynchronous and can be forced at any time. ENTER RESUME PAUSE RUN ENTER RESUME PAUSE RUN PAUSE PAUSE CLOCK 70 71 00 01 10 11 20 21 50 CLOCK 30 51 60 61 70 71 00 01 10 PAUSE PAUSE tPLH tPLH TPB tPHL tPHL TPA WAIT WAIT tSU tSU tH tSU tH tSU NOTE: 9. Pause (in clock waveform) while represented here as one clock cycle in duration, could be infinitely long. FIGURE 12A. TPA PAUSE TIMING FIGURE 12B. TPB PAUSE TIMING FIGURE 12. PAUSE MODE TIMING WAVEFORMS RESET INT • DMA • RESET PAUSE IDLE • DMA • INT S1 RESET FORCE S1 DMA + INT (LONG BRANCH, LONG SKIP, NOP, RSXD, ETC) DMA • FORCE S1 S1 EXECUTE S1 INIT DMA DMA DMA • IDLE • INT • FORCE S1 DMA INT • DMA • FORCE S1 FORCE S0 PRIORITY: S2 DMA DMA SO FETCH DMA • INT S3 INT “68” FORCE S0 DMA INT • DMA FIGURE 13. STATE TRANSITION DIAGRAM 16 RESET FORCE S0, S1 DMA IN DMA OUT INT CDP1805AC, CDP1806AC Instruction Set R(W).0: Lower-order byte of R(W) The CDP1805AC and CDP1806AC instruction summary is given in Table 1. Hexadecimal notation is used to refer to the 4-bit binary codes. R(W).1: Higher-order byte of R(W) Operation Notation In all registers, bits are numbered from the least significant bit (LSB) to the most significant bit (MSB) starting with 0. M (R(N)) → D; R(N) + 1 → R(N) R(W): Register designated by W, where This notation means: The memory byte pointed to by R(N) is loaded into D, and R(N) is incremented by 1. W = N or X, or P TABLE 1. INSTRUCTION SUMMARY (SEE NOTES) NO. OF MACHINE CYCLES MNEMONIC OP CODE LOAD IMMEDIATE 2 LDI F8 REGISTER LOAD IMMEDIATE 5 RLDI 68CN (Note 10) LOAD VIA N 2 LDN 0N M(R(N)) → D; FOR N NOT 0 LOAD ADVANCE 2 LDA 4N M(R(N)) → D; R(N) + 1 → R(N) LOAD VIA X 2 LDX F0 M(R(X)) → D LOAD VIA X AND ADVANCE 2 LDXA 72 M(R(X)) → D; R(X) + 1 → R(X) REGISTER LOAD VIA X AND ADVANCE 5 RLXA 686N (Note 10) STORE VIA N 2 STR 5N D → M(RN)) STORE VIA X AND DECREMENT 2 STXD 73 D → M(R(X)); R(X) - 1 → R(X) REGISTER STORE VIA X AND DECREMENT 5 RSXD 68AN (Note 10) R(N).0 → M(R(X)); R(N).1 → M(R)(X) - 1); R(X) - 2 → R (X) INCREMENT REG N 2 INC 1N R(N) + 1 → R(N) DECREMENT REG N 2 DEC 2N R(N) - 1 → R(N) DECREMENT REG N AND LONG BRANCH IF NOT EQUAL 0 5 DBNZ 682N INCREMENT REG X 2 IRX 60 R(X) + 1 → R(X) GET LOW REG N 2 GLO 8N R(N).0 → D PUT LOW REG N 2 PLO AN D → R(N).0 GET HIGH REG N 2 GHI 9N R(N).1 → D PUT HIGH REG N 2 PHI BN D → R(N).1 REGISTER N TO REGISTER X COPY 4 RNX 68BN (Note 10) R(N) → R(X) OR 2 OR F1 M(R(X)) OR D → D OR IMMEDIATE 2 ORI F9 M(R(P)) OR D → D; R(P) + 1 → R(P) EXCLUSIVE OR 2 XOR F3 M(R(X)) XOR D → D EXCLUSIVE OR IMMEDIATE 2 XRI FB M(R(P)) XOR D → D; R(P) + 1 → R(P) AND 2 AND F2 M(R(X)) AND D → D INSTRUCTION OPERATION MEMORY REFERENCE M(R(P)) → D; R(P) + 1 → R(P) M(R(P)) → R(N).1; M(R(P)) + 1 → R(N).0; R(P) + 2 → R(P) M(R(X)) → R(N).1; M(R(X) + 1) → R(N).0; R(X)) + 2 → R(X) REGISTER OPERATIONS R(N) - 1 → R(N); IF R(N) NOT 0, M(R(P)) → R(P).1, M(R(P) + 1) → R(P).0, ELSE R(P) + 2 → R(P) LOGIC OPERATIONS (Note 19) 17 CDP1805AC, CDP1806AC TABLE 1. INSTRUCTION SUMMARY (SEE NOTES) (Continued) NO. OF MACHINE CYCLES MNEMONIC OP CODE AND IMMEDIATE 2 ANI FA M(R(P)) AND D → D; R(P) + 1 → R(P) SHIFT RIGHT 2 SHR F6 Shift D Right, LSB(D) → DF, 0 → MSB(D) SHIFT RIGHT WITH CARRY 2 SHRC 76 (Note 11) Shift D Right, LSB(D) → DF, DF → MSB(D) RING SHIFT RIGHT 2 RSHR 76 (Note 11) SHIFT D RIGHT, LSB(D) → DF, DF → MSB(D) SHIFT LEFT 2 SHL FE SHIFT LEFT WITH CARRY 2 SHLC 7E (Note 11) SHIFT D LEFT, MSB(D) → DF, DF → LSB(D) RING SHIFT LEFT 2 RSHL 7E (Note 11) SHIFT D LEFT, MSB(D) → DF, DF → LSB(D) ADD 2 ADD F4 DECIMAL ADD 4 DADD 68F4 ADD IMMEDIATE 2 ADI FC M(R(P)) + D → DF, D; R(P) + 1 → R(P) DECIMAL ADD IMMEDIATE 4 DADI 68FC M(R(P)) + D → DF, D; R(P) + 1 → R(P) DECIMAL ADJUST → DF, D ADD WITH CARRY 2 ADC 74 DECIMAL ADD WITH CARRY 4 DADC 6874 M(R(X)) + D + DF → DF, D DECIMAL ADJUST → DF, D ADD WITH CARRY, IMMEDIATE 2 ADCI 7C M(R(P)) + D + DF → DF, D; R(P) + 1 → R(P) DECIMAL ADD WITH CARRY, IMMEDIATE 4 DACI 687C M(R(P)) + D + DF → DF, D; R(P) + 1 → R(P), DECIMAL ADJUST → DF, D SUBTRACT D 2 SD F5 M(R(X)) - D → DF, D SUBTRACT D IMMEDIATE 2 SDI FD M(R(P)) - D → DF, D; R(P) + 1 → R(P) SUBTRACT D WITH BORROW 2 SDB 75 M(R(X)) - D - (NOT DF) → DF, D SUBTRACT D WITH BORROW, IMMEDIATE 2 SDBI 7D M(R(P)) - D - (NOT DF) → DF, D; R(P) + 1 → R(P) SUBTRACT MEMORY 2 SM F7 D - M(R(X)) → DF, D DECIMAL SUBTRACT MEMORY 4 DSM 68F7 SUBTRACT MEMORY IMMEDIATE 2 SMI FF DECIMAL SUBTRACT MEMORY, IMMEDIATE 4 DSMI 68FF SUBTRACT MEMORY WITH BORROW 2 SMB 77 D - M(R(X)) - (NOT DF) → DF, D DECIMAL SUBTRACT MEMORY WITH BORROW 4 DSMB 6877 D - M(R(X)) - (NOT DF) → DF, D; DECIMAL ADJUST → DF, D SUBTRACT MEMORY WITH BORROW, IMMEDIATE 2 SMBI 7F D - M(R(P)) - (NOT DF) → DF, D; R(P) + 1 → R(P) INSTRUCTION OPERATION SHIFT D LEFT, MSB(D) → DF, 0 → LSB(D) ARITHMETIC OPERATIONS (Note 3) 18 M(R(X)) + D → DF, D M(R(X)) + D → DF, D DECIMAL ADJUST → DF, D M(R(X)) + D + DF → DF, D D - M(R(X)) → DF, D; DECIMAL ADJUST → DF, D D - M(R(P)) → DF, D; R(P) + 1 → R(P) D - M(R(P)) → DF, D; R(P) + 1 → R(P), DECIMAL ADJUST → DF, D CDP1805AC, CDP1806AC TABLE 1. INSTRUCTION SUMMARY (SEE NOTES) (Continued) INSTRUCTION DECIMAL SUBTRACT MEMORY WITH BORROW, IMMEDIATE NO. OF MACHINE CYCLES MNEMONIC OP CODE 4 DSBI 687F OPERATION D - M(R(P)) - (NOT DF) → DF, D R(P) + 1 → R(P) DECIMAL ADJUST → DF, D BRANCH INSTRUCTIONS - SHORT BRANCH M(R(P)) → R(P).0 SHORT BRANCH 2 BR 30 NO SHORT BRANCH (See SKP) 2 NBR 38 (Note 11) SHORT BRANCH IF D = 0 2 BZ 32 IF D = 0, M(R(P)) → R(P).0 ELSE R(P) + 1 → R(P) SHORT BRANCH IF D NOT 0 2 BNZ 3A IF D NOT 0, M(R(P)) → R(P).0 ELSE R(P) + 1 → R(P) SHORT BRANCH IF DF = 1 2 BDF 33 (Note 11) IF DF = 1, M(R(P)) → R(P).0 ELSE R(P) + 1 → R(P) SHORT BRANCH IF POS OR ZERO 2 BPZ 33 (Note 11) IF DF = 1, M(R(P)) → R(P).0 ELSE R(P) + 1 → R(P) SHORT BRANCH IF EQUAL OR GREATER 2 BGE 33 (Note 11) IF DF = 1, M(R(P)) → R(P).0, ELSE R(P) + 1 → R(P) SHORT BRANCH IF DF = 0 2 BNF 3B (Note 11) IF D = 0, M(R(P)) → R(P).0, ELSE R(P) + 1 → R(P) SHORT BRANCH IF MINUS 2 BM 3B (Note 11) IF D = 0, M(R(P)) → R(P).0, ELSE R(P) + 1 → R(P) SHORT BRANCH IF LESS 2 BL 3B (Note 11) IF D = 0, M(R(P)) → R(P).0, ELSE R(P) + 1 → R(P) SHORT BRANCH IF Q = 1 2 BQ 31 IF Q = 1, M(R(P)) → R(P).0 ELSE R(P) + 1 → R(P) SHORT BRANCH IF Q = 0 2 BNQ 39 IF Q = 0, M(R(P)) → R(P).0 ELSE R(P) + 1 → R(P) SHORT BRANCH IF EF1 = 1 (EF1 = VSS) 2 B1 34 IF EF1 = 1, M(R(P)) → R(P).0 ELSE R(P) + 1 → R(P) SHORT BRANCH IF EF1 = 0 (EF1 = VDD) 2 BN1 3C IF EF1 = 0, M(R(P)) → R(P).0 ELSE R(P) + 1 → R(P) SHORT BRANCH IF EF2 = 1 (EF2 = VSS) 2 B2 35 IF EF2 = 1, M(R(P)) → R(P).0 ELSE R(P) + 1 → R(P) SHORT BRANCH IF EF2 = 0 (EF2 = VDD) 2 BN2 3D IF EF2 = 0, M(R(P)) → R(P).0 ELSE R(P) + 1 → R(P) SHORT BRANCH IF EF3 = 1 (EF3 = VSS) 2 B3 36 IF EF3 = 1, M(R(P)) → R(P).0 ELSE R(P) + 1 → R(P) SHORT BRANCH IF EF3 = 0 (EF3 = VDD) 2 BN3 3E IF EF3 = 0, M(R(P)) → R(P).0 ELSE R(P) + 1 → R(P) SHORT BRANCH IF EF4 = 1 (EF4 = VSS) 2 B4 37 IF EF4 = 1, M(R(P)) → R(P).0 ELSE R(P) + 1 → R(P) SHORT BRANCH IF EF4 = 0 (EF4 = VDD) 2 BN4 3F IF EF4 = 0, M(R(P)) → R(P).0 ELSE R(P) + 1 → R(P) SHORT BRANCH ON COUNTER INTERRUPT 3 BCI 683E (Note 12) SHORT BRANCH ON EXTERNAL INTERRUPT 3 BXI 683F 19 R(P) + 1 → R(P) IF CI = 1, M(R(P)) → R(P).0; 0 → CI ELSE R(P) + 1 → R(P) IF XI = 1, M(R(P)) → R(P).0 ELSE R(P) + 1 → R(P) CDP1805AC, CDP1806AC TABLE 1. INSTRUCTION SUMMARY (SEE NOTES) (Continued) INSTRUCTION NO. OF MACHINE CYCLES MNEMONIC OP CODE OPERATION BRANCH INSTRUCTIONS - LONG BRANCH M(R(P)) → R(P).1, M(R(P) + 1) → R(P).0 LONG BRANCH 3 LBR C0 NO LONG BRANCH (See LSKP) 3 NLBR C8 (Note 11) LONG BRANCH IF D = 0 3 LBZ C2 IF D = 0, M(R(P)) → R(P).1 M(R(P) + 1) → R(P).0 ELSE R(P) + 2 → R(P) LONG BRANCH IF D NOT 0 3 LBNZ CA IF D NOT 0, M(R(P)) → R(P).1 M(R(P) + 1) → R(P).0 ELSE R(P) + 2 → R(P) LONG BRANCH IF DF = 1 3 LBDF C3 IF DF = 1, M(R(P)) → R(P).1 M(R(P) + 1) → R(P).0 ELSE R(P) + 2 → R(P) LONG BRANCH IF DF = 0 3 LBNF CB IF DF = 0, M(R(P)) → R(P).1 M(R(P) + 1) → R(P).0 ELSE R(P) + 2 → R(P) LONG BRANCH IF Q = 1 3 LBQ C1 IF Q = 1, M(R(P)) → R(P).1 M(R(P) + 1) → R(P).0 ELSE R(P) + 2 → R(P) LONG BRANCH IF Q = 0 3 LBNQ C9 IF Q = 0, M(R(P)) → R(P).1 M(R(P) + 1) → R(P).0 ELSE R(P) + 2 → R(P) SHORT SKIP (See NBR) 2 SKP 38 (Note 11) R(P) + 1 → R(P) LONG SKIP (See NLBR) 3 LSKP C8 (Note 11) R(P) + 2 → R(P) LONG SKIP IF D = 0 3 LSZ CE IF D = 0, R(P) + 2 → R(P) ELSE CONTINUE LONG SKIP IF D NOT 0 3 LSNZ C6 IF D NOT 0, R(P) + 2 → R(P) ELSE CONTINUE LONG SKIP IF DF = 1 3 LSDF CF IF DF = 1, R(P) + 2 → R(P) ELSE CONTINUE LONG SKIP IF DF = 0 3 LSNF C7 IF DF = 0, R(P) + 2 → R(P) ELSE CONTINUE LONG SKIP IF Q = 1 3 LSQ CD IF Q = 1, R(P) + 2 → R(P) ELSE CONTINUE LONG SKIP IF Q = 0 3 LSNQ C5 IF Q = 0, R(P) + 2 → R(P) ELSE CONTINUE LONG SKIP IF MIE = 1 3 LSIE CC IF MIE = 1, R(P) + 2 → R(P) ELSE CONTINUE IDLE 2 IDL 00 (Note 14) NO OPERATION 3 NOP C4 CONTINUE SET P 2 SEP DN N→P SET X 2 SEX EN N→X R(P) + 2 → R(P) SKIP INSTRUCTIONS CONTROL INSTRUCTIONS 20 STOP ON TPB; WAIT FOR DMA OR INTERRUPT; BUS FLOATS CDP1805AC, CDP1806AC TABLE 1. INSTRUCTION SUMMARY (SEE NOTES) (Continued) NO. OF MACHINE CYCLES MNEMONIC OP CODE SET Q 2 SEQ 7B 1→Q RESET Q 2 REQ 7A 0→Q PUSH X, P TO STACK 2 MARK 79 (X, P) → T; (X, P) → M(R(2)), THEN P → X; R(2) → 1→ R(2) LOAD COUNTER 3 LDC 6806 (Note 15) GET COUNTER 3 GEC 6808 CNTR → D STOP COUNTER 3 STPC 6800 STOP CNTR CLOCK; 0 → ÷ 32 PRESCALER DECREMENT TIMER/COUNTER 3 DTC 6801 CNTR - 1 → CNTR SET TIMER MODE AND START 3 STM 6807 TPA ÷ 32 → CNTR SET COUNTER MODE 1 AND START 3 SCM1 6805 EF1 → CNTR CLOCK SET COUNTER MODE 2 AND START 3 SCM2 6803 EF2 → CNTR CLOCK SET PULSE WIDTH MODE 1 AND START 3 SPM1 6804 TPA.EF1 → CNTR CLOCK; STOPS COUNT EF1 SET PULSE WIDTH MODE 2 AND START 3 SPM2 6802 TPA.EF2 → CNTR CLOCK; STOPS COUNT EF2 ENABLE TOGGLE Q 3 ETQ 6809 (Note 15) EXTERNAL INTERRUPT ENABLE 3 XIE 680A 1 → XIE EXTERNAL INTERRUPT DISABLE 3 XID 680B 0 → XIE COUNTER INTERRUPT ENABLE 3 CIE 680C l → CIE COUNTER INTERRUPT DISABLE 3 CID 680D 0 → CIE RETURN 2 RET 70 M(R(X)) → X, P; R(X) + 1 → R(X); 1 → MIE DISABLE 2 DIS 71 M(R(X) → X, P; R(X) + 1 → R(X); 0 → MIE SAVE 2 SAV 78 T → M(R(X)) SAVE T, D, DF 6 DSAV 6876 (Note 10) OUTPUT 1 2 OUT 1 61 M(R(X)) → BUS; R(X) + 1 → R(X) N LINES = 1 OUTPUT 2 2 OUT 2 62 M(R(X)) → BUS; R(X) + 1 → R(X) N LINES = 2 OUTPUT 3 2 OUT 3 63 M(R(X)) → BUS; R(X) + 1 → R(X) N LINES = 3 OUTPUT 4 2 OUT 4 64 M(R(X)) → BUS; R(X) + 1 → R(X) N LINES = 4 OUTPUT 5 2 OUT 5 65 M(R(X)) → BUS; R(X) + 1 → R(X) N LINES = 5 INSTRUCTION OPERATION TIMER/COUNTER INSTRUCTIONS CNTR STOPPED: D → CH, CNTR; 0 → CI. CNTR RUNNING; D → CH IF CNTR = 01 • NEXT CNTR CLOCK INTERRUPT CONTROL R(X) - 1 → R(X), T → M(R(X)), R(X) - 1 → R(X), D → M (R(X)), R(X) - 1 → R(X), SHIFT D RIGHT WITH CARRY, D → M(R(X)) INPUT-OUTPUT BYTE TRANSFER 21 ;Q→Q CDP1805AC, CDP1806AC TABLE 1. INSTRUCTION SUMMARY (SEE NOTES) (Continued) NO. OF MACHINE CYCLES MNEMONIC OP CODE OUTPUT 6 2 OUT 6 66 M(R(X)) → BUS; R(X) + 1 → R(X) N LINES = 6 OUTPUT 7 2 OUT 7 67 M(R(X)) → BUS; R(X) + 1 → R(X) N LINES = 7 INPUT 1 2 INP 1 69 BUS → M(R(X)); BUS → D N LINES = 1 INPUT 2 2 INP 2 6A BUS → M(R(X)); BUS → D N LINES = 2 INPUT 3 2 INP 3 6B BUS → M(R(X)); BUS → D N LINES = 3 INPUT 4 2 INP 4 6C BUS → M(R(X)); BUS → D N LINES = 4 INPUT 5 2 INP 5 6D BUS → M(R(X)); BUS → D N LINES = 5 INPUT 6 2 INP 6 6E BUS → M(R(X)); BUS → D N LINES = 6 INPUT 7 2 INP 7 6F BUS → M(R(X)); BUS → D N LINES = 7 STANDARD CALL 10 SCAL 688N (Note 10) R(N).0 → M(R(X)); R(N).1 → M(R(X) - 1); R(X) - 2 → R(X); R(P) → R(N); THEN M(R(N)) → R(P).1; M(R(N) + 1) → R(P).0; R(N) + 2 → R(N) STANDARD RETURN 8 SRET 689N (Note 10) R(N) → R(P); M(R(X) + 1) → R(N).1; M(R(X) + 2) → R(N).0; R(X) + 2 → R(X) INSTRUCTION OPERATION CALL AND RETURN NOTES: 10. Previous contents of T register are destroyed during instruction execution. 11. This instruction is associated with more than one mnemonic. Each mnemonic is individually listed. 12. ETQ cleared by LDC with the Counter/Timer stopped, reset of CPU, or BCl • (Cl = 1). 13. Cl = Counter Interrupt, Xl = External Interrupt. 14. An IDLE instruction initiates an S1 cycle. All external signals, except the oscillator, are stopped on the low-to-high transition of TPB. All outputs remain in their previous states, MRD, MWR, are set to a logic ‘1’ and the data bus floats. The processor will continue to IDLE until an I/O request (INTERRUPT, DMA-IN, or DMA-OUT) is activated. When the request is acknowledged, the IDLE cycle is terminated and the I/O request is serviced, and the normal operation is resumed. (To respond to an lNTERRUPT during an IDLE, MlE and either ClE or XlE must be enabled). 15. Long-Branch, Long-Skip and No Op instructions require three cycles to complete (1 fetch + 2 execute). Long-Branch instructions are three bytes long. The first byte specifies the condition to be tested; and the second and third byte, the branching address. The long branch instruction can: a. b. c. d. e. Branch unconditionally Test for D = 0 or D ≠ 0 Test for DF = 0 or DF = 1 Test for Q = 0 or Q = 1 Effect an unconditional no branch If the tested condition is met, then branching takes place; the branching address bytes are loaded in the high-and-low-order bytes of the current program counter, respectively. This operation effects a branch to any memory location. If the tested condition is not met, the branching address bytes are skipped over, and the next instruction in sequence is fetched and executed. This operation is taken for the case of unconditional no branch (NLBR). 22 CDP1805AC, CDP1806AC 16. The short-branch instructions are two or three bytes long. The first byte specifies the condition to be tested, and the second specifies the branching address, except for the branches on interrupt. For those, the first two bytes specify the condition to be tested and the third byte specifies the branching address. The short branch instruction can: a. b. c. d. e. f. g. Branch unconditionally Test for D = 0 or D ≠ 0 Test for DF = 0 or DF = 1 Test for Q = 0 or Q = 1 Test the status (1 or 0) of the four EF flags Effect an unconditional no branch Test for counter or external interrupts (BCI, BXI) If the tested condition is met, then branching takes place; the branching address byte is loaded into the low-order byte position of the current program counter. This effects a branch within the current 256-byte page of the memory, i.e., the page which holds the branching address. If the tested condition is not met, the branching address byte is skipped over, and the next instruction in sequence is fetched and executed. This same action is taken in the case of unconditional no branch (NBR). 17. The skip instructions are one byte long. There is one Unconditional Short-Skip (SKP) and eight Long-Skip instructions. The Unconditional Short-Skip instruction takes 2 cycles to complete (1 fetch + 1 execute). Its action is to skip over the byte following it. Then the next instruction in sequence is fetched and executed. This SKP instruction is identical to the unconditional No-Branch Instruction (NBR) except that the skipped-over byte is not considered part of the program. The Long-Skip instructions take three cycles to complete (1 fetch + 2 execute). They can: a. b. c. d. e. Skip unconditionally Test for D = 0 or D ≠ 0 Test for DF = 0 or DF = 1 Test for Q = 0 or Q = 1 Test for MIE = 1 If the tested condition is met, then Long Skip takes place; the current program counter is incremented twice. Thus, two bytes are skipped over and the next instruction in sequence is fetched and executed. If the tested condition is not met, then no action is taken. Execution is continued by fetching the next instruction in sequence. 18. Instruction 6800 through 68FF take a minimum of 3 machine cycles and up to a maximum of 10 machine cycles. In all cases, the first two cycles are fetches and subsequent cycles are executes. The first byte (68) of these two-byte op codes is used to generate the second fetch, the second byte is then interpreted differently than the same code without the 68 prefix. DMA and INT requests are not serviced until the end of the last execute cycle. 19. Arithmetic Operations: The arithmetic and shift operations are the only instructions that can alter the content of DF. The syntax ‘(NOT DF)’ denotes the subtraction of the borrow. Binary Operations: After an ADD instruction DF = 1 denotes a carry has occurred. Result is greater than FF16. DF = 0 denotes a carry has not occurred. After a SUBTRACT instruction DF = 1 denotes no borrow. D is a true positive number. DF = 0 denotes a borrow. D is in two's complement form. Binary Coded Decimal Operations: After a BCD ADD instruction DF = 1 denotes a carry has occurred. Result is greater than 9910. DF = 0 denotes a carry has not occurred. After a BCD SUBTRACT instruction DF = 1 denotes no borrow. D is a true positive decimal number. Example 99 D M(R(X)) -88 11 D DF = 1 DF = 0 denotes a borrow. D is in ten's complement form. Example 88 -99 89 D M(R(X)) D DF = 0 89 is the ten's complement of 11, which is the correct answer (with a minus value denoted by DF = 0). 23 CDP1805AC, CDP1806AC TABLE 2. CONDITIONS ON DATA BUS AND MEMORY ADDRESS LINES DURING ALL MACHINE STATES STATE I N MNEMONIC OPERATION 0 → Q, I, N, COUNTER, PRESCALER, CIL; 1 → CIE, XIE S1 RESET S1 INITIALIZE, NOT PROGRAMMER ACCESSIBLE S0 FETCH X, P → T THEN 0 → X, P; 1 → MIE, 0000 → R0 MRP → I, N; RP + 1 → RP MRD MWR N LINES UNDEFINED 1 1 0 00 (Note 20) UNDEFINED 1 1 0 MRP RP 0 1 0 HIGH Z RO 1 1 0 MRN RN 0 1 0 DATA BUS MEMORY ADDRESS 00 S1 0 0 IDL STOP AT TPB WAIT FOR DMA OR INT S1 0 1-F LDN MRN → D S1 1 0-F INC RN + 1 → RN HIGH Z RN 1 1 0 S1 2 0-F DEC RN - 1 → RN HIGH Z RN 1 1 0 S1 3 0-F SHORT BRANCH TAKEN: MRP → RP.0 NOT TAKEN: RP + 1 → RP MRP RP 0 1 0 S1 4 0-F LDA MRN → D; RN + 1 → RN MRN RN 0 1 0 S1 5 0-F STR D → MRN D RN 1 0 0 S1 6 0 IRX RX + 1 → RX MRX RX 1 1 0 S1 6 1 OUT 1 MRX → BUS; RX + 1 → RX MRX RX 0 1 1 S1 6 2 OUT 2 MRX → BUS; RX + 1 → RX MRX RX 0 1 2 S1 6 3 OUT 3 MRX → BUS; RX + 1 → RX MRX RX 0 1 3 S1 6 4 OUT 4 MRX → BUS; RX + 1 → RX MRX RX 0 1 4 S1 6 5 OUT 5 MRX → BUS; RX + 1 → RX MRX RX 0 1 5 S1 6 6 OUT 6 MRX → BUS; RX + 1 → RX MRX RX 0 1 6 S1 6 7 OUT 7 MRX → BUS; RX + 1 → RX MRX RX 0 1 7 S1 6 9 INP 1 BUS → MRX, D DATA FROM I/O DEVICE RX 1 0 1 S1 6 A INP 2 BUS → MRX, D DATA FROM I/O DEVICE RX 1 0 2 S1 6 B INP 3 BUS → MRX, D DATA FROM I/O DEVICE RX 1 0 3 S1 6 C INP 4 BUS → MRX, D DATA FROM I/O DEVICE RX 1 0 4 S1 6 D INP 5 BUS → MRX, D DATA FROM I/O DEVICE RX 1 0 5 24 CDP1805AC, CDP1806AC TABLE 2. CONDITIONS ON DATA BUS AND MEMORY ADDRESS LINES DURING ALL MACHINE STATES (Continued) DATA BUS MEMORY ADDRESS MRD MWR N LINES BUS → MRX, D DATA FROM I/O DEVICE RX 1 0 6 INP 7 BUS → MRX, D DATA FROM I/O DEVICE RX 1 0 7 0 RET MRX → X, P; RX + 1 → RX 1 → MIE MRX RX 0 1 0 7 1 DIS MRX → X, P; RX + 1 → RX 0 → MIE MRX RX 0 1 0 S1 7 2 LDXA MRX → D; RX + 1 → RX MRX RX 0 1 0 S1 7 3 STXD D → MRX; RX - 1 → RX D RX 1 0 0 S1 7 4 ADC MRX + D + DF → DF, D MRX RX 0 1 0 S1 7 5 SDB MRX - D - DFN → DF, D MRX RX 0 1 0 S1 7 6 SHRC HIGH Z RX 1 1 0 S1 7 7 SMB D - MRX - DFN → DF, D MRX RX 0 1 0 S1 7 8 SAV T → MRX T RX 1 0 0 S1 7 9 MARK X, P → T, MR2; P → X R2 - 1 → R2 T R2 1 0 0 S1 7 A REQ 0→Q HIGH Z RP 1 1 0 S1 7 B SEQ 1→Q HIGH Z RP 1 1 0 S1 7 C ADCI MRP + D + DF → DF, D; RP + 1 MRP RP 0 1 0 S1 7 D SDBI MRP - D - DFN → DF, D; RP + 1 MRP RP 0 1 0 S1 7 E SHLC MSB(D) → DF; DF → LSB D HIGH Z RP 1 1 0 S1 7 F SMBI D - MRP - DFN → DF, D; RP + 1 MRP RP 0 1 0 S1 8 0-F GLO RN.0 → D RN.0 RN 1 1 0 S1 9 0-F GHI RN.1 → D RN.1 RN 1 1 0 S1 A 0-F PLO D → RN.0 D RN 1 1 0 S1 B 0-F PHI D → RN.1 D RN 1 1 0 S1#1 C 0-3, 8-B LONG BRANCH TAKEN: MRP → B; RP + 1 → RP MRP RP 0 1 0 #2 C 0-3, 8-B LONG BRANCH TAKEN: B → RP.1; MRP → RP.0 M(RP + 1) RP + 1 0 1 0 S1#1 C 0-3, 8-B LONG BRANCH NOT TAKEN RP + 1 → RP MRP RP 0 1 0 #2 C 0-3, 8-B LONG BRANCH NOT TAKEN RP + 1 → RP M(RP + 1) RP + 1 0 1 0 S1#1 C 5 LONG SKIP TAKEN: RP + 1 → RP MRP RP 0 1 0 #2 C 6 LONG SKIP TAKEN: RP + 1 → RP M(RP + 1) RP + 1 0 1 0 STATE I N MNEMONIC S1 6 E INP 6 S1 6 F S1 7 S1 OPERATION LSB(D) → DF; DF → MSB(D) 25 CDP1805AC, CDP1806AC TABLE 2. CONDITIONS ON DATA BUS AND MEMORY ADDRESS LINES DURING ALL MACHINE STATES (Continued) DATA BUS MEMORY ADDRESS MRD MWR N LINES M(RP + 1) RP + 1 0 1 0 NOT TAKEN: NO OPERATION MRP RP 0 1 0 LONG SKIP NOT TAKEN: NO OPERATION MRP RP 0 1 0 E LONG SKIP NOT TAKEN: NO OPERATION M(RP + 1) RP + 1 0 1 0 C F LONG SKIP NOT TAKEN: NO OPERATION M(RP + 1) RP + 1 0 1 0 S1#1 C 4 NOP NO OPERATION MRP RP 0 1 0 #2 C 4 NOP NO OPERATION M(RP + 1) RP + 1 0 1 0 S1 D 0-F SEP N→P NN RN 1 1 0 S1 E 0-F SEX N→X NN RN 1 1 0 S1 F 0 LDX MRX → D MRX RX 0 1 0 S1 F 1 OR MRX OR D → D MRX RX 0 1 0 S1 F 2 AND MRX AND D → D MRX RX 0 1 0 S1 F 3 XOR MRX XOR D → D MRX RX 0 1 0 S1 F 4 ADD MRX + D → DF, D MRX RX 0 1 0 S1 F 5 SD MRX - D → DF, D MRX RX 0 1 0 S1 F 7 SM D - MRX → DF; D MRX RX 0 1 0 S1 F 6 SHR LSB(D) → DF; 0 → MSB(D) HIGH Z RX 1 1 0 S1 F 8 LDI MRP → D; RP + 1 → RP MRP RP 0 1 0 S1 F 9 ORI MRP OR D → D; RP + 1 → RP MRP RP 0 1 0 S1 F A ANI MRP AND D → D; RP + 1 → RP MRP RP 0 1 0 S1 F B XRI MRP XOR D → D; RP + 1 → RP MRP RP 0 1 0 S1 F C ADI MRP + D → DF, D; RP + 1 → RP MRP RP 0 1 0 S1 F D SDI MRP - D → DF, D; RP + 1 → RP MRP RP 0 1 0 S1 F F SMI D - MRP → DF, D; RP + 1 → RP MRP RP 0 1 0 S1 F E SHL MSB(D) → DF; 0 → LSB(D) HIGH Z RP 1 1 0 S2 DMA IN DMA IN DMA IN BUS → MR0; R0 + 1 → R0 DATA FROM I/O DEVICE R0 1 0 0 S2 DMA OUT DMA OUT DMA OUT MRO → BUS; R0 + 1 → R0 MR0 R0 0 1 0 S3 INTERRUPT INTERRUPT INTERRUPT HIGH Z RN 1 1 0 STATE I N MNEMONIC OPERATION #2 C 7 LONG SKIP TAKEN: RP + 1 → RP S1#1 C C LONG SKIP S1#1 C D #2 C S1#1 X, P → T; 0 → MIE 1 → P; 2 → X THE FOLLOWING ARE ALL LINKED INSTRUCTIONS “68” PRECEEDS ALL OP CODES, SO THERE IS A DUPLICATE FETCH S1 0 0 STPC S1 0 1 DTC STOP COUNTER CLOCK; 0 → ÷ 32 PRESCALER HIGH Z R0 1 1 0 CNTR - 1 → CNTR HIGH Z R1 1 1 0 26 CDP1805AC, CDP1806AC TABLE 2. CONDITIONS ON DATA BUS AND MEMORY ADDRESS LINES DURING ALL MACHINE STATES (Continued) DATA BUS MEMORY ADDRESS MRD MWR N LINES CNTR - 1 ON EF2 AND TPA HIGH Z R2 1 1 0 SCM2 CNTR - 1 ON EF2 0 TO 1 HIGH Z R3 1 1 0 4 SPM1 CNTR - 1 ON EF1 AND TPA HIGH Z R4 1 1 0 0 5 SCM1 CNTR - 1 ON EF1 0 TO 1 HIGH Z R5 1 1 0 S1 0 6 LDC CNTR STOPPED: D → CH, CNTR; 0 → CI CNTR RUNNING: D → CH D R6 1 1 0 S1 0 7 STM CNTR - 1 ON TPA ÷ 32 HIGH Z R7 1 1 0 S1 0 8 GEC CNTR → D CNTR R8 1 1 0 S1 0 9 ETQ IF CNTR THRU 0: Q → Q HIGH Z R9 1 1 0 S1 0 A XIE 1 → XIE HIGH Z RA 1 1 0 S1 0 B XID 0 → XIE HIGH Z RB 1 1 0 S1 0 C CIE 1 → CIE HIGH Z RC 1 1 0 S1 0 D CID 0 → CIE HIGH Z RD 1 1 0 S1#1 2 0-F DBNZ RN - 1 → RN HIGH Z RN 1 1 0 #2 2 0-F DBNZ MRP → B; RP + 1 → RP MRP RP 0 1 0 #3 2 0-F DBNZ TAKEN: B → RP.1, MRP → RP.0 NOT TAKEN: RP + 1 → RP M(RP + 1) RP + 1 0 1 0 S1 3 E BCI TAKEN: MRP → RP.0; 0 → CI NOT TAKEN: RP + 1 → RP MRP RP 0 1 0 S1 3 F BXI TAKEN: MRP → RP.0 NOT TAKEN: RP + 1 → RP MRP RP 0 1 0 S1#1 6 0-F RLXA MRX → B, RX + 1 → RX MRX RX 0 1 0 #2 6 0-F RLXA B → T; MRX → B; RX + 1 → RX M(RX + 1) RX + 1 0 1 0 #3 6 0-F RLXA B, T → RN.0, RN.1 HIGH Z RN 1 1 0 S1#1 7 4 DADC MRX + D + DF → DF, D MRX RX 0 1 0 #2 7 4 DADC DECIMAL ADJUST → DF, D HIGH Z RD 1 1 1 S1#1 7 6 DSAV RX - 1 → RX HIGH Z RP 1 1 0 #2 7 6 DSAV T → MRX; RX - 1 → RX T RX - 1 1 0 0 #3 7 6 DSAV D → MRX; RX - 1 → RX SHIFT D RIGHT WITH CARRY D RX - 2 1 0 0 #4 7 6 DSAV D → MRX D RX - 3 1 0 0 S1#1 7 7 DSMB D - MRX - (NOT DF) → DF, D MRX RX 0 1 0 #2 7 7 DSMB DECIMAL ADJUST → DF, D HIGH Z RP 1 1 0 S1#1 7 C DACI MRP + D + DF → DF, D; RP + 1 → RP MRP RP 0 1 0 #2 7 C DACI DECIMAL ADJUST → DF, D HIGH Z RP + 1 1 1 0 S1#1 7 F DSBI D - MRP - (NOT DF) → DF, D; RP + 1 → RP MRP RP 0 1 0 STATE I N MNEMONIC S1 0 2 SPM2 S1 0 3 S1 0 S1 OPERATION 27 CDP1805AC, CDP1806AC TABLE 2. CONDITIONS ON DATA BUS AND MEMORY ADDRESS LINES DURING ALL MACHINE STATES (Continued) DATA BUS MEMORY ADDRESS MRD MWR N LINES DECIMAL ADJUST → DF, D HIGH Z RP + 1 1 1 0 SCAL RN.0, RN.1 → T, B HIGH Z RN 1 1 0 0-F SCAL T→ MRX RX - 1 → RX RN.0 RX 1 0 0 8 0-F SCAL B → MRX RX - 1 → RX RN.1 RX - 1 1 0 0 #4 8 0-F SCAL RP.0, RP.1 → T, B HIGH Z RP 1 1 0 #5 8 0-F SCAL B, T → RN.1, RN.0 HIGH Z RN 1 1 0 #6 8 0-F SCAL MRN → B; RN + 1 → RN MRP RP 0 1 0 #7 8 0-F SCAL B → T; MRN → B; RN + 1 → RN M(RP + 1) RP + 1 0 1 0 #8 8 0-F SCAL B, T → RP.0, RP.1 HIGH Z RP 1 1 0 S1#1 9 0-F SRET RN.0, RN.1 → T, B HIGH Z RN 1 1 0 #2 9 0-F SRET RX + 1 → RX HIGH Z RX 1 1 0 #3 9 0-F SRET B, T → RP.1, RP.0 HIGH Z RP 1 1 0 #4 9 0-F SRET MRX → B; RX + 1 → RX M(RX + 1) RX + 1 0 1 0 #5 9 0-F SRET B → T; MRX → B M(RX + 1 RX + 2 0 1 0 #6 9 0-F SRET B, T → RN.0, RN.1 HIGH Z RN 1 1 0 S1#1 A 0-F RSXD RN.0, RN.1 → T, B HIGH Z RN 1 1 0 #2 A 0-F RSXD T → MRX; RX - 1 → RX RN.0 RX 1 0 0 #3 A 0-F RSXD B → MRX; RX - 1 → RX RN.1 RX - 1 1 0 0 S1#1 B 0-F RNX RN.0, RN.1 → T, B HIGH Z RN 1 1 0 #2 B 0-F RNX B, T → RX.1, RX.0 HIGH Z RX 1 1 0 S1#1 C 0-F RLDI MRP → B; RP + 1 → RP MRP RP 0 1 0 #2 C 0-F RLDI B → T; MRP → B; RP + 1 → RP M(RP + 1) RP + 1 0 1 0 #3 C 0-F RLDI B, T → RN.0, RN.1;` RP + 1 → RP HIGH Z RN 1 1 0 S1#1 F 4 DADD MRX + D → DF; D MRX RX 0 1 0 #2 F 4 DADD DECIMAL ADJUST → DF, D HIGH Z RP 1 1 0 S1#1 F 7 DSM D - MRX → DF, D MRX RX 0 1 0 #2 F 7 DSM DECIMAL ADJUST → DF, D HIGH Z RP 1 1 0 S1#1 F C DADI MRP + D → DF, D; RP + 1 → RP MRP RP 0 1 0 #2 F C DADI DECIMAL ADJUST → DF, D HIGH Z RP + 1 1 1 0 S1#1 F F DSMI D - MRP → DF, D RP + 1 → RP MRP RP 0 1 0 #2 F F DSMI DECIMAL ADJUST → DF, D HIGH Z RP + 1 1 1 0 STATE I N MNEMONIC #2 7 F DSBI S1#1 8 0-F #2 8 #3 OPERATION NOTE: 20. Data bus floats for first 2-1/2 clocks of the nine clock initialization cycle; all zeros for remainder of cycle. 28 CDP1805AC, CDP1806AC INSTRUCTION SUMMARY N 0 0 1 2 3 4 5 6 7 IDL 8 INC 2 DEC BR BQ BZ BDF B1 B2 B3 B4 SKP 4 LDA 5 STR 6 IRX 7 RET OUT DIS LDXA STXD ADC SDB SHRC SMB SAV E F BNQ BNZ BNF BN1 BN2 BN3 BN4 SDBI SHLC SMBI LSKP LBNQ LBNZ LBNF LSIE LSQ LSZ LSDF ANI XRI ADI SDI SHL SMI ETQ XIE XID CIE CID - - - - - - - BCI BXI - - - DACI - - DSBI - - - DADI - - DSMI A PLO B PHI LBQ LBZ LBDF NOP LSNQ LSNZ LSNF D SEP E SEX OR AND XOR INP ADCI GHI LDX D SEQ 9 F C REQ GLO LBR B † 8 C A LDN 1 3 9 ADD SD SHR SM LDI MARK ORI ‘68’ LINKED OPCODES (DOUBLE FETCH) 0 STPC DTC SPM2 SCM2 SPM1 SCM1 LDC STM 2 3 DBNZ - - - - - - - - 6 7 GEC RLXA - - - - DADC - DSAV DSMB - 8 SCAL 9 SRET A RSXD B RNX C RLDI F - - - - DADD - - DSM †‘68’ is used as a linking OPCODE for the double fetch instructions. 29 - CDP1805AC, CDP1806AC Operating and Handling Considerations Handling Input Signals All inputs and outputs of Intersil CMOS devices have a network for electrostatic protection during handling. Operating To prevent damage to the input protection circuit, input signals should never be greater than VDD nor less than VSS. Input currents must not exceed 10mA even when the power supply is off. Operating Voltage Unused Inputs During operation near the maximum supply voltage limit, care should be taken to avoid or suppress power supply turn-on and turn-off transients, power supply ripple, or ground noise; any of these conditions must not cause VDD VSS to exceed the absolute maximum rating. A connection must be provided at every input terminal. All unused input terminals must be connected to either VDD or VSS, whichever is appropriate. Output Short Circuits Shorting of outputs to VDD or VSS may damage CMOS devices by exceeding the maximum device dissipation. All Intersil U.S. products are manufactured, assembled and tested utilizing ISO9000 quality systems. Intersil Corporation’s quality certifications can be viewed at www.intersil.com/design/quality Intersil products are sold by description only. Intersil Corporation reserves the right to make changes in circuit design, software and/or specifications at any time without notice. Accordingly, the reader is cautioned to verify that data sheets are current before placing orders. Information furnished by Intersil is believed to be accurate and reliable. However, no responsibility is assumed by Intersil or its subsidiaries for its use; nor for any infringements of patents or other rights of third parties which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of Intersil or its subsidiaries. For information regarding Intersil Corporation and its products, see www.intersil.com 30