Product datasheet PTo 35/220…240 POWERTRONIC OUTDOOR PTo | ECG for HID lamps, for outdoor lighting Areas of application _ Suitable for luminaires of protection classes I and II _ Suitable for outdoor applications in luminaires with IP > 54 __ Product benefits _ Energy savings up to 30 % (compared to CCG operation) thanks to 3DIM (except PTo 35) _ High surge protection: up to 3 kV (L-N) / 4 kV (L/N-PE) _ Automatic safety shutdown of lamps in the event of a defect or at end of life (EoL) _ Excellent thermal behavior for very high limit temperatures t and t c a Product features _ 3DIM functionality (StepDIM/AstroDIM/DALI) _ Energy Efficiency Index EEI: A2 _ Lightning protection: up to 10 kV _ Line voltage: 198…264 V _ Line frequency: 50…60 Hz _ Line harmonics according to EN 61000-3-2 _ Immunity according to EN 61547 _ RI suppression: to EN 55015 (A1: 2007) up to 300 MHz _ Safety: to EN 61347-2-12 _ Luminous flux factor 1 compared with CCG operation _ Not suitable for DC operation June 4, 2016, 09:25:45 PTo 35/220…240 © 2016, OSRAM GmbH. All rights reserved. Page 1 of 6 Product datasheet Technical data Electrical data __ Lamp wattage 39 W Line current 0.20 A 1) Ignition voltage 4.5 kVp Operating frequency 0.165 kHz System wattage 43.00 W ECG efficiency 90 % 2) Input voltage AC 198…264 V Nominal voltage 220…240 V Mains frequency 50…60 Hz Power factor λ 0.95 Inrush current 35 A 4) Max. ECG no. on circuit breaker 10 A (B) 7 Max. ECG no. on circuit breaker 16 A (B) 13 5) Max. no. of ECGs on 16A MCB with EBN-OS 32 5) Protective conductor current 0.1 mA U-OUT (working voltage) 250 V Max. working voltage between LH and LL 250 V Max. working voltage betw. LL/LH & earth 250 V Max. capacitance of wire ECG/lamp 120 pF Surge capability (L-N) 3 kV Surge capability (L/N-Ground) 4 kV 3) 5) 1) At 230 V AC 2) Approximately 3) Minimum 4) t width 5) Type B = 350 µs (measured at 50 % I June 4, 2016, 09:25:45 PTo 35/220…240 ) peak © 2016, OSRAM GmbH. All rights reserved. Page 2 of 6 Product datasheet Dimensions & weight __ Length 133.0 mm Width 77.0 mm Height 48.0 mm Mounting hole spacing, length 123.0 mm Cable cross-section, input side 0.5…2.5 mm² Cable cross-section, output side 0.5…2.5 mm² Wire preparation length, input side 10…11 mm Wire preparation length, output side 10…11 mm Product weight 730.00 g Colors & materials Casing material Plastic Temperatures & operating conditions Ambient temperature range -25…+60 °C Maximum temperature at tc test point 75 °C Lifespan ECG lifetime 60000 h 1) 1) At maximum T / 10% failure rate c Additional product data Required IP rating of luminaire ≥ 54 Design / version ECG outdoor Encapsulated Yes 1) 1) PCB fully encapsulated + dust proof plastic housing June 4, 2016, 09:25:45 PTo 35/220…240 © 2016, OSRAM GmbH. All rights reserved. Page 3 of 6 Product datasheet Capabilities Max. cable length to lamp/LED module 1.5 m Overheating protection Power reduction and switch off at T > 75 °C at the tc point ECG reset time > 0.5 s Dimmable No Restriction on ignition time 20 min Suitable for fixtures with prot. class I / II Lightning stroke protection With connected equipotentiality-terminal 10 surges with 10 kV acc. to IEC 61000-4-5 Certificates & standards Approval marks – approval ENEC 10 / VDE / VDE-EMC / EAC / C-Tick Type of protection IP20 EEI – Energy Label A2 Standards Acc. to EN 61347-2-12/Acc. to EN 55015/Acc. to EN 61000-3-2/Acc. to EN 61547 Wiring Diagram __ Wiring diagram June 4, 2016, 09:25:45 PTo 35/220…240 © 2016, OSRAM GmbH. All rights reserved. Page 4 of 6 Product datasheet Safety advice Ballast losses and lamp heat radiation can lead to heat accumulation in a completely closed case. Therefore it is necessary to ensure that the temperature at the measuring point t of the ECG does not exceed the maximum value. Attention! For safety reasons disconnect the device before replacing the lamp! Additional product information _ An external relay connected in front of the SD port is necessary in StepDIM installations. The relay needs to be selected in a way that it is not switched or hold by the occurring leakage currents in the installation. Download Data File Tender documents Tender Document for POWERTRONIC EVG.eng Certificates EMC-Marks approval __ Certificates PTi - PTo - PTg VDE-ENEC-Cert Certificates EAC PT family Declarations of conformity Declaration of conformity PTo 35 Declarations of conformity VDE Declaration of conformity Installation/Operation notice Technical guide - POWERTRONIC for HID-lamps (GB) Operating instructions EAC-PTO CAD data 3-dim PTo35 CAD data 3-dim PTo35 CAD data 3-dim PTo35 Logistical Data June 4, 2016, 09:25:45 PTo 35/220…240 © 2016, OSRAM GmbH. All rights reserved. Page 5 of 6 Product datasheet Product code Product description Packaging unit (Pieces/Unit) Dimensions (length x width x height) Volume Gross weight 4008321956323 PTo 35/220…240 Shipping carton box 20 483 mm x 167 mm x 285 mm 22.99 dm³ 15471.00 g The mentioned product code describes the smallest quantity unit which can be ordered. One shipping unit can contain one or more single products. When placing an order, for the quantity please enter single or multiples of a shipping unit. Disclaimer Subject to change without notice. Errors and omission excepted. Always make sure to use the most recent release. __ June 4, 2016, 09:25:45 PTo 35/220…240 © 2016, OSRAM GmbH. All rights reserved. Page 6 of 6