Product data sheet

Product datasheet
PTo 100/220…240 3DIM
POWERTRONIC OUTDOOR PTo | ECG for HID lamps, for outdoor lighting
Areas of application
_ Suitable for luminaires of protection classes I and II
_ Suitable for outdoor applications in luminaires with IP >
54
__
Product benefits
_ Energy savings up to 30 % (compared to CCG operation) thanks to 3DIM (except PTo 35)
_ High surge protection: up to 3 kV (L-N) / 4 kV (L/N-PE)
_ Automatic safety shutdown of lamps in the event of a defect or at end of life (EoL)
_ Excellent thermal behavior for very high limit temperatures t and t
c
a
Product features
_ 3DIM functionality (StepDIM/AstroDIM/DALI)
_ Energy Efficiency Index EEI: A2
_ Lightning protection: up to 10 kV
_ Line voltage: 198…264 V
_ Line frequency: 50…60 Hz
_ Line harmonics according to EN 61000-3-2
_ Immunity according to EN 61547
_ RI suppression: to EN 55015 (A1: 2007) up to 300 MHz
_ Safety: to EN 61347-2-12
_ Luminous flux factor 1 compared with CCG operation
_ Not suitable for DC operation
June 4, 2016, 09:25:47
PTo 100/220…240 3DIM
© 2016, OSRAM GmbH. All rights reserved.
Page 1 of 7
Product datasheet
Technical data
Electrical data
__
Lamp wattage
97 W
Line current
0.48 A 1)
Ignition voltage
4.5 kVp
Operating frequency
0.165 kHz
System wattage
106.00 W
Power loss in stand-by mode
<0.5 W 2)
ECG efficiency
91 %
Input voltage AC
198…264 V
Nominal voltage
220…240 V
Nominal input voltage (SD port)
220…240 V 3)
Mains frequency
50…60 Hz
Power factor λ
0.95
Inrush current
60 A 5)
Max. ECG no. on circuit breaker 10 A (B)
4
6)
Max. ECG no. on circuit breaker 16 A (B)
7
6)
Max. no. of ECGs on 16A MCB with EBN-OS
17
Protective conductor current
0.1 mA
U-OUT (working voltage)
250 V
Max. working voltage between LH and LL
250 V
Max. working voltage betw. LL/LH & earth
250 V
Max. capacitance of wire ECG/lamp
120 pF
Surge capability (L-N)
3 kV
Surge capability (L/N-Ground)
4 kV
4)
6)
1) At 230 V
AC
2) Only in DALI operation mode
3) In relation to L/N / Active: input current > 14 mA
pk
4) Minimum
5) t
width
6) Type B
= 250 µs (measured at 50 % I
June 4, 2016, 09:25:47
PTo 100/220…240 3DIM
/ Inactive: input current < 2 mA
pk
)
peak
© 2016, OSRAM GmbH. All rights reserved.
Page 2 of 7
Product datasheet
Dimensions & weight
__
Length
158.0 mm
Width
94.0 mm
Height
42.5 mm
Mounting hole spacing, length
148.0 mm
Cable cross-section, input side
0.5…2.5 mm²
Cable cross-section, output side
0.5…2.5 mm²
Wire preparation length, input side
10…11 mm
Wire preparation length, output side
10…11 mm
Product weight
900.00 g
Colors & materials
Casing material
Plastic
Temperatures & operating conditions
Ambient temperature range
-25…+55 °C
Maximum temperature at tc test point
75 °C
Lifespan
ECG lifetime
60000 h 1)
1) At maximum T / 8% failure rate
c
Additional product data
Required IP rating of luminaire
≥ 54
Design / version
ECG outdoor
Encapsulated
Yes
1)
1) PCB fully encapsulated + dust proof plastic housing
June 4, 2016, 09:25:47
PTo 100/220…240 3DIM
© 2016, OSRAM GmbH. All rights reserved.
Page 3 of 7
Product datasheet
Capabilities
Dimming interface
DALI / StepDIM / AstroDIM
Dimming range
60…100 %
Max. cable length to lamp/LED module
1.5 m
Burn-in time prior to dimming operation
10 min
Overheating protection
Power reduction and switch off at T > 75 °C at the tc
point
ECG reset time
> 0.5 s
Dimmable
Yes
Restriction on ignition time
20 min
Suitable for fixtures with prot. class
I / II
Lightning stroke protection
With connected equipotentiality-terminal 10 surges
with 10 kV acc. to IEC 61000-4-5
1)
1) HQI lamps excluded from dimming
Certificates & standards
__
Approval marks – approval
ENEC 10 / VDE / VDE-EMC / EAC / C-Tick
Type of protection
IP20
EEI – Energy Label
A2
Standards
Acc. to EN 61347-2-12/Acc. to EN 55015/Acc. to EN
61000-3-2/Acc. to EN 61547/Acc. to EN 62386101/Acc. to EN 62386-102/Acc. to EN 62386-103
June 4, 2016, 09:25:47
PTo 100/220…240 3DIM
© 2016, OSRAM GmbH. All rights reserved.
Page 4 of 7
Product datasheet
Wiring Diagram
Wiring diagram
Wiring diagram
Wiring diagram
Wiring diagram
__
June 4, 2016, 09:25:47
PTo 100/220…240 3DIM
© 2016, OSRAM GmbH. All rights reserved.
Page 5 of 7
Product datasheet
Guarantee
Safety advice
Ballast losses and lamp heat radiation can lead to heat accumulation in a completely closed case. Therefore it is necessary to
ensure that the temperature at the measuring point t of the ECG does not exceed the maximum value.
Attention!
For safety reasons disconnect the device before replacing the lamp!
__
Additional product information
_ An external relay connected in front of the SD port is necessary in StepDIM installations. The relay needs to be selected in a
way that it is not switched or hold by the occurring leakage currents in the installation.
Download Data
File
Tender documents
Tender Document for POWERTRONIC EVG.eng
Brochures
LMS 3 DIM Flyer (GB)
Brochures
3DIM - controll gears - Reliable, durable and efficient (G)
Brochures
3DIM Application Guide (GB)
Certificates
EMC-Marks approval
Certificates
PTi - PTo - PTg VDE-ENEC-Cert
Certificates
EAC PT family
June 4, 2016, 09:25:47
PTo 100/220…240 3DIM
© 2016, OSRAM GmbH. All rights reserved.
Page 6 of 7
Product datasheet
Declarations of conformity
Declaration of conformity PTo 100 3DIM, PTo 150 3DIM
Declarations of conformity
VDE Declaration
Declarations of conformity
VDE Declaration of conformity
Installation/Operation notice
Technical guide - POWERTRONIC for HID-lamps (GB)
Operating instructions
EAC-PTO
CAD data 3-dim
CAD data 3-dim PTo100_150 IGS
CAD data 3-dim
CAD data 3-dim PTo100_150.STEP
Product movie
3DIM Astro, StepDIM, DALI Video
Logistical Data
__
Product code
Product description
Packaging unit (Pieces/Unit)
Dimensions (length x width x
height)
Volume
Gross weight
4008321956361
PTo 100/220…240 3DIM
Shipping carton box
10
313 mm x 193 mm x 273 mm
16.49 dm³
9756.00 g
The mentioned product code describes the smallest quantity unit which can be ordered. One shipping unit can contain one or
more single products. When placing an order, for the quantity please enter single or multiples of a shipping unit.
Disclaimer
Subject to change without notice. Errors and omission excepted. Always make sure to use the most recent release.
June 4, 2016, 09:25:47
PTo 100/220…240 3DIM
© 2016, OSRAM GmbH. All rights reserved.
Page 7 of 7