SERIES: VIBLSD1-SIP │ DESCRIPTION: DC-DC CONVERTER
FEATURES
•
•
•
•
•
•
1 W isolated output
industry standard 4 pin SIP package
single regulated outputs
1,000 Vdc isolation
wide temperature (-40~85°C)
efficiency up to 75%
RoHS
MODEL
input
voltage
output
voltage
output
current
output
power
ripple1
noise1
efficiency
typ
(Vdc)
range
(Vdc)
(Vdc)
min
(mA)
max
(mA)
max
(W)
max
(mVp-p)
max
(mVp-p)
typ
(%)
VIBLSD1-S5-S5-SIP
5
4.75~5.25
5
20
200
1
20
75
67
VIBLSD1-S5-S9-SIP
5
4.75~5.25
9
12
111
1
20
75
70
VIBLSD1-S5-S12-SIP
5
4.75~5.25
12
9
83
1
20
75
71
VIBLSD1-S5-S15-SIP
5
4.75~5.25
15
7
67
1
20
75
73
VIBLSD1-S5-S24-SIP
5
4.75~5.25
24
5
42
1
20
75
68
VIBLSD1-S12-S5-SIP
12
11.4~12.6
5
20
200
1
20
75
67
VIBLSD1-S12-S9-SIP
12
11.4~12.6
9
12
111
1
20
75
72
VIBLSD1-S12-S12-SIP
12
11.4~12.6
12
9
83
1
20
75
70
VIBLSD1-S12-S15-SIP
12
11.4~12.6
15
7
67
1
20
75
74
VIBLSD1-S12-S24-SIP
12
11.4~12.6
24
5
42
1
20
75
68
VIBLSD1-S15-S5-SIP
15
14.25~15.75
5
20
200
1
20
75
67
VIBLSD1-S15-S9-SIP
15
14.25~15.75
9
12
111
1
20
75
71
VIBLSD1-S15-S12-SIP
15
14.25~15.75
12
9
83
1
20
75
71
VIBLSD1-S15-S15-SIP
15
14.25~15.75
15
7
67
1
20
75
72
VIBLSD1-S15-S24-SIP
15
14.25~15.75
24
5
42
1
20
75
68
VIBLSD1-S24-S5-SIP
24
22.8~25.2
5
20
200
1
20
75
68
VIBLSD1-S24-S9-SIP
24
22.8~25.2
9
12
111
1
20
75
68
VIBLSD1-S24-S12-SIP
24
22.8~25.2
12
9
83
1
20
75
73
VIBLSD1-S24-S15-SIP
24
22.8~25.2
15
7
67
1
20
75
75
VIBLSD1-S24-S24-SIP
24
22.8~25.2
24
5
42
1
20
75
68
Notes:
1. Ripple and noise are measured at 20 MHz BW by “parallel cable” method with 1 μF ceramic and 10 μF electrolytic capacitors on the output.
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: VIBLSD1-SIP │ DESCRIPTION: DC-DC CONVERTER
date 02/09/2015 │ page 2 of 5
PART NUMBER KEY
VIBLSD1 - SXX - SXX -SIP
Base Number
Input Voltage
Output Voltage
Packaging Style
INPUT
parameter
conditions/description
operating input voltage
5 Vdc models
12 Vdc models
15 Vdc models
24 Vdc models
min
typ
max
units
4.75
11.4
14.25
22.8
5
12
15
24
5.25
12.6
15.75
25.2
Vdc
Vdc
Vdc
Vdc
min
typ
max
units
±0.25
%
±2
%
±3
%
OUTPUT
parameter
conditions/description
line regulation
for Vin change of 5%
load regulation
measured from 10% load to full load
voltage accuracy
switching frequency
100% load, input voltage range
120
temperature coefficient
300
±0.03
kHz
%/°C
PROTECTIONS
parameter
conditions/description
short circuit protection
5 and 24 Vdc output models
all other models: continuous
min
typ
max
units
1
s
max
units
SAFETY AND COMPLIANCE
parameter
conditions/description
isolation voltage
for 1 minute at 1 mA max.
isolation resistance
at 500 Vdc
MTBF
as per MIL-HDBK-217F @ 25°C
RoHS
2011/65/EU
min
typ
1,000
Vdc
1,000
MΩ
3,500,000
hours
ENVIRONMENTAL
parameter
conditions/description
min
operating temperature
see derating curve
storage temperature
storage humidity
non-condensing
temperature rise
at full load
hand soldering
1.5 mm from case for 10 seconds
typ
max
units
-40
85
°C
-55
125
°C
95
%
25
°C
300
°C
15
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: VIBLSD1-SIP │ DESCRIPTION: DC-DC CONVERTER
date 02/09/2015 │ page 3 of 5
DERATING CURVES
Load (%)
100
80
60
40
20
-40
-20
0
20
40
60 71
85
100
120
Ambient Temperature (°C)
MECHANICAL
parameter
conditions/description
dimensions
19.60 x 6.00 x 10.00 (0.772 x 0.236 x 0.394 inch)
min
case material
plastic (UL94-V0)
typ
max
units
mm
weight
2.1
g
MECHANICAL DRAWING
GND
4
0V
6
+Vo
>@
>@
>@
>@
(Front View)
>@
(Bottom View)
cui.com
>@
>@
>@
>@
> @
>@
>@
2
>@
>@
+Vin
>@
FUNCTION
1
>@
>@
>@
PIN
>@
PIN CONNECTIONS
>@
units: mm [inches]
tolerance: ±0.25 [±0.010]
pin section tolerance: ±0.10 mm [±0.004]
For more information, please visit the product page.
CUI Inc │ SERIES: VIBLSD1-SIP │ DESCRIPTION: DC-DC CONVERTER
date 02/09/2015 │ page 4 of 5
APPLICATION NOTES
1. Requirement on Output Load
In order to ensure the product operates efficiently and reliably, make sure the specified range of input voltage is not exceeded and the
minimum output load is not less than 10% load. If the actual load is less than the specified minimum load, the output ripple may
increase sharply while its efficiency and reliability will reduce greatly. If the actual output power is very small, please add an
appropriate resistor as extra loading.
2. Overload Protection
Under normal operating conditions, the output circuit of these products has no protection against over-current and short-circuits. The
simplest method is to connect a self-recovery fuse in series at the input end or add a circuit breaker to the circuit.
3. Filtering
In some circuits which are sensitive to noise and ripple, a filtering capacitor may be added to the DC/DC output end and input end to
reduce the noise and ripple. However, the capacitance of the output filter capacitor must be proper. If the capacitance is too big, a
startup problem might arise. For every channel of output, provided the safe and reliable operation is ensured, the greatest
capacitance of its filter capacitor sees the external capacitor table. To get an extremely low ripple, an “LC” filtering network may be
connected to the input and output ends of the DC/DC converter, which may produce a more significant filtering effect. It should also
be noted that the inductance and the frequency of the “LC” filtering network should be staggered with the DC/DC frequency to avoid
mutual interference (Figure 1).
L
L
Figure 1
Vin
DC DC
C
GND
+Vo
C
0V
4. Output Voltage Regulation and Over-voltage Protection Circuit
The simplest device for output voltage regulation, over-voltage and over-current protection is a linear voltage regulator with overheat
protection that is connected to the input or output end in series (Figure 2).
Figure 2
Vin
REG
GND
+Vout
DC DC
0V
5. External Capacitor Table
It is not recommended to connect any external capacitor in the application field with less than 0.5 W output.
Table 1
Notes:
Vin
(Vdc)
Cin
(µF)
Vout
(Vdc)
Cout
(µF)
5
4.7
5
10
12
4.7
9
4.7
15
2.2
12
2.2
24
1
15
1
--
--
24
0.47
1. Operation under minimum load will not damage the converter; however, they may not meet all specifications listed.
2. Max. capacitive load tested at input voltage range and full load.
3. All specifications measured at: Ta=25°C, humidity<75%, nominal input voltage and rated output load, unless otherwise specified.
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: VIBLSD1-SIP │ DESCRIPTION: DC-DC CONVERTER
date 02/09/2015 │ page 5 of 5
REVISION HISTORY
rev.
description
date
1.0
initial release
12/09/2005
1.01
new template applied, V-Infinity branding removed,
0.75 watt, 15 Vdc input & 24 Vdc output models added
09/06/2012
1.02
removed UL marking from datasheet
01/10/2013
1.03
updated spec
07/11/2013
updated spec
02/09/2015
1.04
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
[email protected]
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical
component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to
affect its safety or effectiveness.