UNISONIC TECHNOLOGIES CO., LTD U74LVC125A CMOS IC QUADRUPLE BUS BUFFER GATE WITH 3-STATE OUTPUTS DESCRIPTION The U74LVC125A consists of four bus buffers with 3-state output controlled by enable input ( ΟΕ ), when ΟΕ is high, the output is disable. Inputs can be driven from either 3.3V or 5V devices, so the device can be used in a mix 3.3V/5V system. FEATURES * Operation Voltage Range: 1.65~3.6V * Low Power Dissipation * Input Accept Voltage to 5.5V ORDERING INFORMATION Ordering Number U74LVC125AG-S14-R U74LVC125AG-P14-R Package SOP-14 TSSOP-14 Packing Tape Reel Tape Reel MARKING www.unisonic.com.tw Copyright © 2015 Unisonic Technologies Co., Ltd 1 of 5 QW-R502-182.D U74LVC125A CMOS IC PIN CONFIGURATION FUNCTION TABLE (each gate) INPUT OUTPUT ΟΕ A Y L L H L H X L H Z LOGIC DIAGRAM (positive logic) UNISONIC TECHNOLOGIES CO., LTD www.unisonic.com.tw 2 of 5 QW-R502-182.D U74LVC125A CMOS IC ABSOLUTE MAXIMUM RATINGS PARAMETER SYMBOL RATINGS UNIT Supply Voltage VCC -0.5~6.5 V Input Voltage VIN -0.5~6.5 V Output Voltage(active mode) VOUT -0.5~VCC+0.5 V Input Clamp Current(ViN<0) IIK -50 mA Output Clamp Current(VO<0) IOK -50 mA Output Current IOUT ±50 mA VCC or GND Current ICC ±100 mA Power Dissipation PD 500 mW Storage Temperature TSTG -65 ~ +150 °С Note: Absolute maximum ratings are those values beyond which the device could be permanently damaged. Absolute maximum ratings are stress ratings only and functional device operation is not implied. RECOMMENDED OPERATING CONDITIONS PARAMETER SYMBOL Supply Voltage VCC Input Voltage Output Voltage Input Rise or Fall Times Operating Temperature VIN VOUT tR, tF TA CONDITIONS Operating Data retention only MIN 1.65 1.5 0 0 TYP -40 MAX 3.6 UNIT V 5.5 VCC 8 125 V V ns/V °С MAX UNIT STATIC CHARACTERISTICS (TA=25°C, unless otherwise specified) PARAMETER SYMBOL TEST CONDITIONS VCC=1.65V ~ 1.95V High-Level Input Voltage VIH VCC=2.3V ~ 2.7V VCC=2.7V ~ 3.6V MIN 0.65× VCC 1.7 2 TYP V V V 0.35×V VCC=1.65V ~ 1.95V Low-Level Input Voltage VIL High-Level Output Voltage VOH Low-Level Output Voltage Input Leakage Current Output OFF-State current Quiescent Supply Current Additional Quiescent Supply Current Input Capacitance VOL II(LEAK) IOZ IQ IQ CIN VCC=2.3V ~ 2.7V VCC=2.7V ~ 3.6V VCC=1.65V ~ 3.6V, IOH=-100μA VCC-0.2 VCC=1.65V, IOH=-4mA 1.29 VCC=2.3V, IOH=-8mA 1.9 VCC=2.7V, IOH=-12mA 2.2 VCC=3V, IOH=-12mA 2.4 VCC=3V, IOH=-24mA 2.3 VCC=1.65V ~ 3.6V, IOL=100μA VCC=1.65V, IOL=4mA VCC=2.3V, IOL=8mA VCC=2.7V, IOL=12mA VCC=3V, IOL=24mA VCC=3.6V, VIN=5.5V or GND VCC=3.6V, VOUT=VCC or GND VCC=3.6V, VIN=VCC or GND IOUT=0 VCC=2.7V~3.6V, One input at VCC0.6V, other inputs at VCC or GND VCC=3.3V, VIN=VCC or GND UNISONIC TECHNOLOGIES CO., LTD www.unisonic.com.tw CC 0.7 0.8 5 V 0.1 0.24 0.3 0.4 0.55 ±1 ±1 1 V V V V V V V V V V V V V μA μA μA 500 μA pF 3 of 5 QW-R502-182.D U74LVC125A CMOS IC DYNAMIC CHARACTERISTICS (TA=25°С, unless otherwise specified) PARAMETER SYMBOL Propagation delay from input (A) to output (Y) tPLH/tPHL Output enable time from input ( ΟΕ ) to output (Y) tPZL/tPZH Output disable time from input ( ΟΕ ) to output (Y) tPLZ/tPHZ TEST CONDITIONS VCC= 1.8V±0.15V VCC= 2.5V±0.2V VCC= 2.7V VCC= 3.3V±0.3V VCC= 1.8V±0.15V VCC= 2.5V±0.2V VCC= 2.7V VCC= 3.3V±0.3V VCC= 1.8V±0.15V VCC= 2.V5±0.2V VCC= 2.7V VCC= 3.3V±0.3V MIN 1 1 1 1 1 1 1 1 1 1 1 1 TYP 4.5 2.7 3 2.5 4.3 2.7 3.3 2.4 4.3 2.2 2.5 2.4 MAX 11.8 5.8 5.3 4.6 13.8 6.9 6.4 5.2 10.6 5.1 4.8 4.4 UNIT ns ns ns ns ns ns ns ns ns ns ns ns TYP 7.4 11.3 15 MAX UNIT pF pF pF OPERATING CHARACTERISTICS (TA=25°С, unless otherwise specified) PARAMETER SYMBOL Power Dissipation Capacitance CPD TEST CONDITIONS VCC=1.8V, f=10MHz VCC=2.5V, f=10MHz VCC=3.3V, f=10MHz UNISONIC TECHNOLOGIES CO., LTD www.unisonic.com.tw MIN 4 of 5 QW-R502-182.D U74LVC125A CMOS IC TEST CIRCUIT AND WAVEFORMS Note: CL includes probe and jig capacitance. VCC 1.8V±0.15V 2.5V±0.2V 2.7V 3.3V±0.3V VIN VCC VCC 2.7V 2.7 V tR,/tF ≤2ns ≤2ns ≤2.5ns ≤2.5ns VM VCC/2 VCC/2 1.5V 1.5V VLOAD 2* VCC 2* VCC 6V 6V CL 30pF 30pF 50pF 50pF RL 1KΩ 500Ω 500Ω 500Ω V△ 0.15V 0.15V 0.3V 0.3V UTC assumes no responsibility for equipment failures that result from using products at values that exceed, even momentarily, rated values (such as maximum ratings, operating condition ranges, or other parameters) listed in products specifications of any and all UTC products described or contained herein. UTC products are not designed for use in life support appliances, devices or systems where malfunction of these products can be reasonably expected to result in personal injury. Reproduction in whole or in part is prohibited without the prior written consent of the copyright owner. The information presented in this document does not form part of any quotation or contract, is believed to be accurate and reliable and may be changed without notice. UNISONIC TECHNOLOGIES CO., LTD www.unisonic.com.tw 5 of 5 QW-R502-182.D