pdf

www.osram.com/flex
LINEARLIGHT FLEX ADVANCED
LF06A
TECHNICAL DATASHEET
Key Features & Benefits
‒
‒
‒
‒
‒
Linear separable LED strip on flexible printed circuit
board with self-adhesive back
High quality single PCB from continuous reel-to-reel
production for improved reliability
Current control technology for constant flux level
along the module
Fine white binning (3 steps MacAdam ellipse)
PWM Dimmable
Possible Applications
‒
‒
‒
Architectural lighting / integration
Coves, hand rails, walls, edge coupling, et.al.
Object lighting / integration
Signage application
QUICK REFERENCE
Product
Order Code
Color
K
V
W/m
lm/m
lm/W
Beam Angle (°)
Shipping Units
LF06A-W3F-824
4052899942783
white
2400
24
4.5
380
84
120
8
LF06A-W3F-827
4008321973986
white
2700
24
4.8
390
81
120
8
LF06A-W3F-830
4008321973993
white
3000
24
4.8
390
81
120
8
LF06A-W3F-840
4008321974006
white
4000
24
4.8
425
88
120
8
LF06A-W3F-850
4008321974013
white
5000
24
4.8
425
88
120
8
LF06A-W3F-865
4008321974020
white
6500
24
4.8
425
88
120
8
Due to the special conditions of manufacturing processes of LED, the typical data of technical parameters can only reflect statistical figures and do n ot
necessarily correspond to the actual parameters of each single product which could differ from the typical data.
Subject to change without notice. Errors and omissions excepted.
Version: 2016-04-07
01
LINEARLIGHT FLEX ADVANCED | LF06A | TECHNICAL DATASHEET
TECHNICAL OPERATING DATA FOR COMPLETE REEL
Product
Order Code
Power [W]
Current [A]
Luminous Flux [lm]
Module Length [m]
LF06A-W3F-824
4052899942783
45.0
1.9
3,800
10
LF06A-W3F-827
4008321973986
48.0
2.0
3,900
10
LF06A-W3F-830
4008321973993
48.0
2.0
3,900
10
LF06A-W3F-840
4008321974006
48.0
2.0
4,230
10
LF06A-W3F-850
4008321974013
48.0
2.0
4,230
10
LF06A-W3F-865
4008321974020
48.0
2.0
4,230
10
Technical Specifications
GENERAL
Dimmable
Pulse width modulation (PWM)
Binning
Fine white (3 step MacAdam ellipse)
Lifetime
50,000 h (L70B50, Tc max)
Adhesive tape on backside
3M F 9460
Complementary systems
CONNECTsystem, SLIMCONNECTsystem, SLIM TRACK, OPTOTRONIC
Certifications
CE, UL8750 recognized, UL2108 listed, ENEC, EAC, RoHS compliant
OPERATING CONDITIONS
Operating temperature at Tc-Point [°C]
-30 – 75
Storage temperature [°C]
-40 – 75
Voltage range [V dc]
23 – 25
Reverse Voltage [V dc]
25
‒
‒
‒
Exceeding maximum ratings for operating and storage temperature will reduce expected life time or destroy the LED Module.
Exceeding maximum ratings for operating voltage will cause hazardous overload and will likely destroy the LED Module.
The temperature of the LED module must be measured at the Tc-point according to EN60598-1 in a thermally constant status with a
temperature sensor or a temperature sensitive label. For exact location of the Tc -point see drawing below.
Technical Drawings
Due to the special conditions of manufacturing processes of LED, the typical data of technical parameters can only reflect st atistical figures and do not
necessarily correspond to the actual parameters of each single product which could differ from the typical data.
Subject to change without notice. Errors and omissions excepted.
Version: 2016-04-07
02
LINEARLIGHT FLEX ADVANCED | LF06A | TECHNICAL DATASHEET
Safety information
‒
‒
‒
‒
‒
‒
‒
‒
‒
‒
‒
‒
‒
The LED module itself and all its components must not be mechanically stressed.
Assembly must not damage or destroy conducting paths on the circuit board.
Installation of LED modules (with power supplies) needs to be made with regard to all app licable electrical
and safety standards. Only qualified personnel should be allowed to perform installations.
Observe correct polarity!
Depending on the product incorrect polarity will lead to emission of red or no light. The module can be
destroyed! Correct polarity immediately!
Parallel connection is highly recommended as safe electrical operation mode. Serial connection is not
recommended. Unbalanced voltage drop can cause hazardous overload and damage the LED module.
Please ensure that the power supply is of adequate power to operate the total load.
When mounting on metallic or otherwise conductive surfaces, there needs to be an electrical isolation at
soldering points between module and the mounting surface.
The maximum length of LF06A is 10m with power feed at one end.
Pay attention to standard ESD precautions when installing the module.
If the module is supposed to be cut at the earl-cutting-positions intended for the LF-2TERM respect the
correct orientation of the module: The power feed must come from the side indicated in the technical drawing
The module, as manufactured, has no conformal coating and therefore offers no inherent protection against
corrosion. The ability to customize the length of the module by cutting at specifically marked points is a key
feature of the product and hence the reason for no factory installed conformal coating. For these reasons, it
is recommended that the user complete all module modifications first (cutting wiring) and then apply a
conformal coating in the final stages of installation.
Damage by corrosion will not be honored as a materials defect claim. It is the user´s responsibility to provide
suitable protection again corrosive agents such as moisture and condensation and other harmful elements.
For applications involving exposure to humidity and dust the module must be protected by a fixture or
housing with a suitable protection class. The module can be protected against condensation water by
treatment with an appropriate circuit board grade conformal coating. The co nformal coating should have the
following features:
o
o
o
o
o
Optical transparency
UV-resistance
Thermal expansion matching the thermal expansion of the module
Low permeability of steam for all climatic conditions
Resistance against corrosive environment.
In order to drive OSRAM LED-Modules safely, it is absolutely necessary to operate them with an electronically stabilized power supply protecting against
short circuits, overload and overheating. To also ease the luminaire/installation approval, electronic control gear for LED or LED modules should carry
the CE mark and be ENEC certified. In Europe the declarations of conformity must include the following standards: CE: EC 6134 7-2-13, EN 55015, IEC
61547 and IEC 61000-3-2 - ENEC: 61347-2-13 and IEC/EN 62384. Also check for the mark of an independent authorized certification institute. Please
see the relevant brochure for more detailed information (see "Related and Further Information") OSRAM OPTOTRONIC® control gear complies with all
relevant standards and guarantees safe operation.
Assembly Information
‒
‒
‒
‒
Connection with soldering wires on unmounted module:
Do not pre-tin the solder-pads but pre-tin the wires and solder for max 4s at 300°C.
Allow solder-points to completely cool down before the next soldering.
Prevent shear- or peel forces.
Soldering of wires with the module mounted on a heatsink:
Pre-tin solder-pads and wires and solder for max 3 s at 350 °C.
Allow solder-points to completely cool down before the next soldering.
Prevent shear- or peel forces.
The smallest unit (100 mm – 6 LEDs) can be removed by cutting with scissors between the designated solder
pads.
Mounting of the module is facilitated by the double-sided adhesive tape on the back-surface of the module.
Due to the special conditions of manufacturing processes of LED, the typical data of technical parameters can only reflect st atistical figures and do not
necessarily correspond to the actual parameters of each single product which could differ from the typical data.
Subject to change without notice. Errors and omissions excepted.
Version: 2016-04-07
03
LINEARLIGHT FLEX ADVANCED | LF06A | TECHNICAL DATASHEET
‒
‒
‒
‒
‒
‒
Mounting surface must be clean and dry, free of oils or silicone coatings as well as dirt particle.
The mounting substrate must have sufficient structural integrity. Take care to completely remove the
protective backing. Once the module is appropriately positioned, pre on the module with about 20N/cm² (refer
to application techniques of 3M adhesive transfer tapes). In difficult cases the use of a prime may help.
Maximum temperature ratings must be kept. Therefore the module may have to be mounted on a metal heat
sink, depending on the individual installation.
The minimum bending radius is 2 cm. The module may be bent over a smaller radius but only in regions of
the circuit board containing electronic components and such bends should be made once and fixed in
position to avoid cyclic fatigue.
Bending is only allowed within the bending axis of the PCB. Bending outside of that leads to torsion which
may cause damage to the module and will lead to failure.
When installing in environments with large variations in temperature (e.g. outdoor applications) and operating
length of more than 2 m, the use of adequate mounting surfaces is necessary. Otherwise it is advisable to
use an additional thicker adhesive tape to absorb the stress of any mismatch in expansion.
Complementary Systems & Accessories
SLIMCONNECT SYSTEM
Description
Product name
Order Code
Shipping details
2pin Feeder
LF-2PIN Flex SC
4008321832436
10 / 250
Jumper (board-to-board)
LF-CONN Flex SC
4008321832467
25 / 250
Extension wire 30mm
LF-WIRE-30 FLEX SC
4008321875587
100 / 10,000
Extension wire 150mm
LF-WIRE-150 FLEX SC
4008321875563
50 / 5,000
Description
Product name
Order Code
2pin Feeder
LF-2PIN FLEX
4008321955326
10 / 100
Jumper (10mm extension)
LF-CONN-10 FLEX
4008321955333
10 / 200
Jumper (150mm extension)
LF-CONN-150 FLEX
4008321955340
10 / 100
Termination unit for early-cutting-marks
LF-2TERM FLEX
4008321955357
10 / 200
Description
Product name
Order Code
SLIM TRACK
LF-LTS-2100 SLIM TRACK
4008321978981
40
Mounting Bracket for SLIM TRACK
LF-LTS-MB
4008321979025
35 / 280
Clear SLIM TRACK Cover
LF-LTS COVER C
4008321790187
40
Diffuse SLIM TRACK Cover
LF-LTS-COVER-DIFFUSE
4008321979001
40
Endcap for Diffuse Cover
LF-LTS-ENDCAP
4008321979049
20 / 160
Semi-Diffuse SLIM TRACK Cover
LF-LTS COVER S
4008321790200
40
CONNECT SYSTEM
Shipping details
SLIMTRACK SYSTEM
Shipping details
Due to the special conditions of manufacturing processes of LED, the typical data of technical parameters can only reflect st atistical figures and do not
necessarily correspond to the actual parameters of each single product which could differ from the typical data.
Subject to change without notice. Errors and omissions excepted.
Version: 2016-04-07
04
LINEARLIGHT FLEX ADVANCED | LF06A | TECHNICAL DATASHEET
OPTOTRONIC
Recommended OPTOTRONIC® drivers
EAN
Non-dimmable
OPTOTRONIC OT 6/200-240/24 CE
4008321113269
OPTOTRONIC OT 8/200-240/24
4008321040169
OPTOTRONIC OT 20/220-240/24
4050300618111
OPTOTRONIC OT 20/120-240/24 S
4050300662626
OPTOTRONIC OT 75/220-240/24
4050300817477
OPTOTRONIC OT 75/220-240/24 E
4008321362476
OPTOTRONIC OT 80/220-240/24 P
4008321981684
OPTOTRONIC OT 120/220-240/24 P
4008321981707
OPTOTRONIC OT 240/220-240/24 P
Dimmable
4008321981721
OPTOTRONIC OT EASY 60 II
4008321187796
OPTOTRONIC OT EASY 80
4008321808363
OPTOTRONIC OT 65/220-240/24 3DIM E
4008321964403
OPTOTRONIC OTi DALI 75/220-240/24 1-4 CH
4008321371560
OPTOTRONIC OT 80/220-240/24 DIM P
4008321981677
OPTOTRONIC OT 120/220-240/24 DIM P
4008321981691
OPTOTRONIC OT 240/220-240/24 DIM P
4008321981714
Please consider that lengths may differ if further controls are installed.
Maximim length per OT:
lA + lB + l C + …  l max/OT
lA
Maximum length per strip:
lB
lA
lB
lC
l…
OT – 24V
lC
≤
≤
≤
≤
10,000
10,000
10,000
10,000
mm
mm
mm
mm
Global order information
EUROPE/MEA
US/CA
LF06A-W3F-824
4052899942783
LF06A-W3F-827
4008321973986
L48LFE/24V/827/ADV/G3/A
71310
LF06A-W3F-830
4008321973993
L48LFE/24V/830/ADV/G3/A
71309
LF06A-W3F-840
4008321974006
L48LFE/24V/840/ADV/G3/A
71308
LF06A-W3F-850
4008321974013
LF06A-W3F-865
4008321974020
Due to the special conditions of manufacturing processes of LED, the typical data of technical parameters can only reflect st atistical figures and do not
necessarily correspond to the actual parameters of each single product which could differ from the typical data.
Subject to change without notice. Errors and omissions excepted.
Version: 2016-04-07
05
www.osram.com/flex
LINEARLIGHT FLEX ADVANCED
LF06A
TECHNICAL DATASHEET
2016-04-07
Related and further information
‒
‒
‒
OSRAM LED Systems www.osram.com/led-systems
OSRAM: FLEXIBLE LED MODULES www.osram.com/flex
OSRAM catalogue http://catalog.osram.com
‒
General information www.osram.com
OSRAM GmbH
Head Office:
Marcel-Breuer-Strasse 6
80807 Munich, Germany
+49 89 6213-0
www.osram.com
Sales and technical support is given by the local OSRAM subsidiaries.
On the OSRAM website all subsidiaries are listed with complete address and phone
numbers.