www.osram.com
OSRAM APAC
Value Flex Protect – VFP1300-G1
Technical Datasheet
Benefits
 Energy saving low-power LED flexible strip
 Easy installation with Track
 Multi cut-able with IP54 connectors
 Available in warm white and cold white
 120ºviewing angle per module
 IP66 Protection
 Dimmable
Applications
 Hospitality Lighting
 General Illumination
 Signage
 Architecture lighting
 Wall integration
Technical Operating Data
Color
No. of
LEDs
Voltage
[V DC]*
Power
[W]*
Current
VFP1300-G1-827-05
White
216
24
83.5
3.48
VFP1300-G1-830-05
White
216
24
83.5
VFP1300-G1-840-05
White
216
24
VFP1300-G1-865-05
White
216
24
Product
Wavelength
Color Temp
Lum. Flux
[lm]/meter *
Lum. Flux
[lm]/chain*
2700 K
1300
6500
3.48
3000 K
1300
6500
83.5
3.48
4000 K
1400
7000
83.5
3.48
6500 K
1400
7000
[A]*
[K]*
*) All Data are related to the entire module.
Due to the special conditions of the manufacturing processes of LED the typical data of technical parameters can only reflect statistical figures and do not
necessarily correspond to the actual parameters of each single product which could differ from the typical data.
Technical Features
 Size of printed circuit board (L x W x H):
 CRI 80
 Linear LED strip on flexible printed circuit board with
self-adhesive tape at the back allow for easy mounting
5010 mm x 11 mm x 4.8 mm
 Size of smallest unit : 138mm
 Up to 35,000 hrs lifetime @ Tc = 60 ℃.
 The LED pitch is 23.06mm
 Connection possible at the reel end or at the cut points
 24V Constant Voltage LED modules
 Colour consistency <4 SCDM
VFP1300 – G1– 20.05.2015
 Accessories:
− 3M UR connector x 4pcs
− End cap x 10pcs
− Mounting clips x 20pcs
− 2.5mm x 10mm Screws x 40pcs
Page 1 of 4
www.osram.com
OSRAM APAC
Minimum / Maximum Ratings
Operating
Temperature at
Tc-Point [°C]*
Storage Temperature
[°C]*
Voltage Range
[V dc]*
Reverse Voltage
[V dc]*
VFP1300-G1-827-05
-10 … 60
-20 … 65
23 … 25
25
VFP1300-G1-830-05
-10 … 60
-20 … 65
23 … 25
25
VFP1300-G1-840-05
-10 … 60
-20 … 65
23 … 25
25
VFP1300-G1-865-05
-10 … 60
-20 … 65
23 … 25
25
Product
*) Exceeding maximum ratings for operating and storage temperature will reduce expected life time or destroy the LED Modules.
Exceeding maximum ratings for operating voltage will cause hazardous overload and will likely destroy the LED Modules.
The temperature of the LED modules must be measured at the Tc-point according to EN60598-1 in a thermally constant status with a temperature sensor or a temperature
sensitive label.
Dimension
Safety Information
 The LED module itself and all its components must not be mechanically stressed.
 Assembly must not damage or destroy conducting paths on the circuit board.
 To avoid mechanical damage, the LED modules should be attached securely to the intended substrate. Heavy vibration
should be avoided.
The LED module incorporates no protection against short circuits, overload or overheating.
In order to drive OSRAM LED-Modules safely, it is absolutely necessary to operate them with an electronically
stabilized power supply protecting against short circuits, overload and overheating.
For dimming applications attention should be paid to specific references in “OPTOTRONIC ® Technical Guide”.
To also ease the luminaire/installation approval, electronic control gear for LED or LED modules must carry the CE mark.
In Europe the declarations of conformity must include the following standards:
CE: EN 61347-2-13, EN 55015, EN 61547 and EN 61000-3-2.
Also check for the mark of an independent authorized certification institute.
Please see the relevant application guides for more detailed information.
When using power supplies other than OPTOTRONIC ® the following basic safety features are required, in addition to any
other application specific concerns and local safety codes.
OSRAM OPTOTRONIC® electronic control gear complies to all relevant standards and guarantees safe operation.
VFP1300 – G1– 20.05.2015
Page 2 of 4
www.osram.com
OSRAM APAC
 Installation of LED modules (with power supplies) needs to be made with regard to all applicable electrical and safety
standards. Only qualified personnel should be allowed to perform installations.
 Observe correct polarity! Incorrect polarity will lead to no light emission and may cause damage of the LED module.
 Parallel connection is highly recommended as safe electrical operation mode. Serial connection is not recommended.
Unbalanced voltage drop can cause hazardous overload and damage the LED module.
 The maximum length of VFP1300-G1 is 5M with power feed at one end.
 When mounting on metallic or otherwise conductive surfaces, there needs to be a electrical isolation at soldering points
between module and the mounting surface,
 Pay attention to ESD steps when mounting the module.
 Please ensure that the power supply is of adequate power to operate the total load.
 LED modules are dimmable by means of PWM (pulse width modulation). It is recommended using the following OSRAM
control gears: OPTOTRONIC® OT DIM, OT DALI DIM, OT DALI DIM LI.
 Damage by corrosion will not be honored as a materials defect claim. It is the user’s responsibility to provide suitable
protection against corrosive agents such as moisture and condensation and other harmful elements.
 For applications involving exposure to humidity and dust the module must be protected by a fixture or housing with a
suitable protection class.
Assembly Information
 The smallest electrical unit (SEU) (138mm - 6 LEDs) can be removed by cutting at the printed marks at the side.

After cutting connect the module via IP54 CONNECTsystem. Insert module into connector and apply pressure on a hard
surface until locked.
 The mounting of the single LED coupons is facilitated by means of the double-sided adhesive on the back surface of the
module. Care must be taken to provide a clean and dry mounting surface, free of oils or silicone coatings as well as dirt
particle. The mounting substrate must have sufficient structural integrity. Take care to completely remove the adhesive
backing. Once the module is appropriately positioned, press on the module with about 20N/cm²(refer to application
techniques of Tesa adhesive transfer tapes). To support adhesion at higher temperatures, it’s necessary to use additional
mounting brackets.

The minimum bending radius is 5 cm.

When installing in environments with large variations in temperature (e.g. outdoor applications) and operating length of
more than 2 m, the use of adequate mounting surfaces is necessary . Otherwise it is advisable to use an additional thicker
adhesive tape to absorb the stress of any mismatch in expansion.
 Pay attention to avoid highly corrosive atmospheres, e.g. permanent high humidity or Hydrogen Sulfide (H2S). With current
LED technology, H2S is causing accelerated corrosion which will lead to shortened time life or premature failure. Sources
for H2S may be rubber, foamed rubber, soft-foam-tapes, sealing on rubber basis, natural sources (e.g. sulfur springs), etc.
To avoid H2S from sulfur-vulcanized rubber it is necessary to switch to silicon based materials or rubber that is Peroxidcrossl inked.
 Indication may be found in the material datasheet of the rubber supplier.
VFP1300 – G1– 20.05.2015
Page 3 of 4
www.osram.com
OSRAM APAC
SLIMCONNECT (IP54) & SLIMTRACK System
Product code
EAN 10*
S-Unit*
LF-2PIN Flex IP SC
4008321841902
10
LF-CONN Flex SC
4008321832467
25
LF-CONN Flex IP SC
4008321841926
25
LF-LTS-2100-SLIM-TRACK
4008321978981
40
Board to board connection
through combination of both!
Ordering Guide
Product code
Product name
EAN 10*
S-Unit*
VFP1300-G1-827-05
Value Flex Protect 1300lm/m G1 2700K
4052899316621
20
VFP1300-G1-830-05
Value Flex Protect 1300lm/m G1 3000K
4052899316645
20
VFP1300-G1-840-05
Value Flex Protect 1300lm/m G1 4000K
4052899316669
20
VFP1300-G1-865-05
Value Flex Protect 1300lm/m G1 6500K
4052899316683
20
* EAN 10: Ordering number per single sale unit
* S-Unit: Modules / accessory number per shipping unit
Note: Typical performance data are subject to change without any further notice, particularly as LED technology evolves.
Sales and Technical Support
OSRAM Asia Pacific
Sales and technical support is given by the
local OSRAM subsidiaries.
On our world wide homepage all OSRAM
subsidiaries are listed with complete address
and phone numbers.
5/F, Hantang Building, OCT
Shennan Ave, Nan Shan District,
518053, Shenzhen, Guangdong, P.R.
China
www.osram.com
VFP1300 – G1– 20.05.2015
Page 4 of 4