4" FarReach Specifications

FarReach™ Drill Pipe
4” SPECIFICATIONS
Drill Pipe Dimensions and Materials
Pipe Body
New
Premium
OD (in) 4.200
4.016
Wall Thickness (in) 0.460
0.368
Wear Band Diameter (in) 4.200
Remaining Body Wall (%) 100.00%
80.0%
Reduction in OD (%) 0.00%
4.4%
ID (in) 3.280
3.280
Alloy / Temper 2014-T6
Yield Strength (ksi) 58
Modulus (msi) 10.6
Cross Sectional Area (in^2) 5.405
4.217
Tool Joint
NC46
Connection New
Premium
OD (in) 5.750
5 10/32
ID (in) 3.280
3.280
Box Tong Length, Lb (in) 10.900
Pin Tong Length, Lp (in) 6.400
Yield Strength (ksi) 120
Drill Pipe Assembly Data
Open Displacement
Shoulder to Shoulder Length (ft) 30.00
(US gal/ft) Closed Displacement
Approximate Weight (lb) 285
(US gal/ft) Adjusted Weight (lb/ft) 9.49
Capacity (US gal/ft) Drill Pipe Mechanical Performance
Pipe Body
New
Premium
Tensile Strength (lbf) 313,000
245,000
Torsional Strength (ft-lbf) 25,500
19,700
80% Torsional Strength (ft-lbf) 20,400
15,700
Collapse Pressure (psi) 11,800
9,190
Internal Yield Pressure (psi) 11,100
10,600
Tool Joint
New
Premium
Tensile Strength (lbf) 883,000
663,000
Torsional Strength (ft-lbf) 32,500
15,700
Recommended Make-Up Torque (ft-lbf) 19,500
9,450
Balanced OD (in) 5.71
5.71
Torsional Ratio TJ/Pipe 1.28
0.800
Class 2
3.924
0.322
70.0%
6.6%
3.280
3.644
Class 2
5 8/32
3.280
0.34
0.79
0.45
Class 2
211,000
16,900
13,500
7,710
9,520
Class 2
604,000
13,500
8,130
5.71
0.800
Alcoa FarReach™ Drill Pipe delivers the industry’s
This lightweight, high-strength combination allows
highest strength-to-weight ratio, improved hydraulic
for drilling to much greater depths and distances
performance, optimized wear characteristics, and a
with existing drilling equipment. Find out more
high level of corrosion resistance.
about FarReach™, and how it can help your
FarReach™ Drill Pipe enables extending the reach of
operation go farther, starting today.
Tong sizes 2in longer than standard.
your operation in deepwater, horizontal drilling and
other Extended Reach Drilling (ERD) applications.
Drill Pipe Mechanical Performance Notes:
(1) Tensile strength based on minimum yield strength.
(2) Torsional strength based on shear strength equal to 57.7% of minimum yield strength.
(3) Collapse pressure calculated per ISO/DIS 20312.
(4) Internal yield pressure calculated per API Bullentin 5C3 which includes a 12.5% knockdown for new pipe.
(5) Performance calculated with frictional factor and safety factor of 1.0.
For more
information on how Alcoa can help you leverage high strength-to-weight aluminum alloy
(6) All data based on nominal dimensions and calculated per standard methods unless otherwise noted.
technology,
visit AlcoaOilandGas.com.
(7) Pipe properties base on pipe dimensions (non-upset area).
(8) These data are intended for a preliminary evaluation of this configuration.
© 2013
Alcoa Oil & Gas. All rights reserved.
AO1151 1013
Report Number: 20131009-136 Revision: 1.0 Revision Date: 20-DEC-2010