5" FarReach Specifications

FarReach™ Drill Pipe
5” SPECIFICATIONS
Drill Pipe Dimensions and Materials
Pipe Body
New
Premium
OD (in) 5.150
4.940
Wall Thickness (in) 0.525
0.420
Wear Band Diameter (in) 5.150
Remaining Body Wall (%) 100.0%
80.0%
Reduction in OD (%) 0.00%
4.1%
ID (in) 4.100
4.100
Alloy / Temper 2014-T6
Yield Strength (ksi) 58
Modulus (msi) 10.6
Cross Sectional Area (in^2) 7.628
5.964
Tool Joint
5-1/2FH
Connection New
Premium
OD (in) 7.000
6 13/32
ID (in) 4.094
4.094
Box Tong Length, Lb (in) 11.031
Pin Tong Length, Lp (in) 6.781
Yield Strength (ksi) 120
Drill Pipe Assembly Data
Open Displacement
Shoulder to Shoulder Length (ft) 30.00
(US gal/ft) Closed Displacement
Approximate Weight (lb) 409
(US gal/ft) Adjusted Weight (lb/ft) 13.64
Capacity (US gal/ft) Drill Pipe Mechanical Performance
Pipe Body
New
Premium
Tensile Strength (lbf) 442,000
346,000
Torsional Strength (ft-lbf) 44,700
34,700
80% Torsional Strength (ft-lbf) 35,800
27,800
Collapse Pressure (psi) 10,700
8,180
Internal Yield Pressure (psi) 10,300
9,860
Tool Joint
New
Premium
Tensile Strength (lbf) 1,190,000
852,000
Torsional Strength (ft-lbf) 52,400
27,800
Recommended Make-Up Torque (ft-lbf) 31,400
16,700
Balanced OD (in) 6.83
6.83
Torsional Ratio TJ/Pipe 1.17
0.800
Class 2
4.835
0.367
70.0%
6.1%
4.100
5.158
Class 2
6 11/32
4.094
0.49
1.19
0.71
Class 2
299,000
29,900
23,900
6,740
8,820
Class 2
766,000
23,900
14,300
6.83
0.800
TheFarReach™
values used are
same
as in the
brochure This lightweight, high-strength combination allows
Alcoa
Drillthe
Pipe
delivers
theprivious
industry’s
DRAFT
highest strength-to-weight ratio, improved hydraulic
for drilling to much greater depths and distances
performance, optimized wear characteristics and a
with existing drilling equipment. Find out more
high level of corrosion resistance.
about FarReach™ and how it can help your
FarReach™ Drill Pipe enables extending the reach
of your operation in deepwater, horizontal drilling and
operation go farther, starting today.
other Extended Reach Drilling (ERD) applications.
Drill Pipe Mechanical Performance Notes:
(1) Tensile strength based on minimum yield strength.
(2) Torsional strength based on shear strength equal to 57.7% of minimum yield strength.
(3) Collapse pressure calculated per ISO/DIS 20312.
(4) Internal yield pressure calculated per API Bullentin 5C3 which includes a 12.5% knockdown for new pipe.
(5) Performance calculated with frictional factor and safety factor of 1.0.
(6) All data based on nominal dimensions and calculated per standard methods unless otherwise noted.
(7) Pipe properties base on pipe dimensions (non-upset area).
(8) These
data areon
intended
for a preliminary
of thishigh
configuration.
more
information
how Alcoa
can helpevaluation
you leverage
strength-to-weight
For
aluminum alloy technology, visit AlcoaOilandGas.com.
Report Number: 20130813-124 Revision: 0.0 Revision Date: 13-AUG-2013
© 2013 Alcoa Oil & Gas. All rights reserved.
AO1153
1013