For more information, please visit the product page. date 09/16/2013 page 1 of 6 SERIES: CFM 60 │ DESCRIPTION: DC AXIAL FAN FEATURES • • • • 60 x 60 mm frame high fan speed for greater air flow two ball bearing construction auto restart protection standard on all models RoHS operating voltage rated current input current input power (Vdc) (Vdc) max (A) max (A) max (W) auto restart tachometer signal rotation detector PWM control signal CFM-6010-13-10 12 6~13.8 0.20 0.26 3.12 x - - - CFM-6010-13-11 12 6~13.8 0.20 0.26 3.12 x - x - CFM-6010-13-20 12 6~13.8 0.20 0.26 3.12 x x - - CFM-6010-13-22 12 6~13.8 0.20 0.26 3.12 x x - x CFM-6015-13-10 12 6~13.8 0.17 0.22 2.64 x - - - CFM-6015-13-11 12 6~13.8 0.17 0.22 2.64 x - x - CFM-6015-13-20 12 6~13.8 0.17 0.22 2.64 x x - - CFM-6015-13-22 12 6~13.8 0.17 0.22 2.64 x x - x CFM-6025-13-10 12 6~13.8 0.32 0.4 4.8 x - - - CFM-6025-13-11 12 6~13.8 0.32 0.4 4.8 x - x - CFM-6025-13-20 12 6~13.8 0.32 0.4 4.8 x x - - CFM-6025-13-22 12 6~13.8 0.32 0.4 4.8 x x - x MODEL rated voltage fan protection PART NUMBER KEY CFM-60XX-13-XX-CXX Base Number Depth 10 = 10 mm 15 = 15 mm 25 = 25 mm Reserved for Custom Configurations Voltage Type 1 = 12 Vdc Fan Speed 3 = high speed cui.com Fan Protection 10 = auto restart protection 11 = auto restart protection / rotation detector 20 = auto restart protection / tachometer signal 22 = auto restart protection / tachometer signal / PWM control signal For more information, please visit the product page. CUI Inc │ SERIES: CFM 60 │ DESCRIPTION: DC AXIAL FAN date 09/16/2013 │ page 2 of 6 SPECIFICATION parameter conditions/description min frame CFM-6010 models CFM-6015 models CFM-6025 models depth typ max units 60 mm 10 15 25 mm mm mm 6 4 Vdc Vdc starting voltage at 25°C, power on/off CFM-6010/15 models CFM-6025 models rated speed at 25°C, after 10 minutes CFM-6010 models CFM-6015 models CFM-6025 models air flow at 0 mm H2O, see performance curves CFM-6010 models CFM-6015 models CFM-6025 models 24.18 27.50 36.25 CFM CFM CFM static pressure at 0 CFM, see performance curves CFM-6010 models CFM-6015 models CFM-6025 models 5.58 5.78 16.91 mmH2O mmH2O mmH2O noise at 1 m CFM-6010 models CFM-6015 models CFM-6025 models 40.0 37.5 48.0 insulation resistance of frame at 500 Vdc between frame and positive terminal dielectric strength at 500 Vac, 60 Hz, 1 minute between frame and positive terminal life expectancy at 45°C, 15~65 RH operating temperature humidity range RoHS yes cui.com 4,950 4,590 6,930 5,500 5,100 7,700 6,050 5,610 8,470 41.4 39.0 49.0 10 RPM RPM RPM dBA dBA dBA MΩ 5 mA 70,000 hours -10 70 °C 15 66 RH For more information, please visit the product page. CUI Inc │ SERIES: CFM 60 │ DESCRIPTION: DC AXIAL FAN date 09/16/2013 │ page 3 of 6 PERFORMANCE CURVES 0.24 0.19 0.14 0.28 6.00 5.00 0.22 0.05 0.00 0.17 0.11 2.00 0.00 0.00 5.00 10.00 15.00 20.00 25.00 30.00 (CFM) 0.17 0.34 0.51 0.68 0.85 (CMM) (mm H2O) (Inch H2O) CFM-6025 0.71 18.00 16.00 0.57 0.43 0.28 0.14 14.00 12.00 10.00 8.00 6.00 4.00 2.00 0.00 0.00 0.00 0.00 6.00 4.00 3.00 2.00 0.06 1.00 0.00 0.00 7.00 5.00 4.00 3.00 0.09 (mm H2O) (Inch H2O) CFM-6015 (mm H2O) (Inch H2O) CFM-6010 10.00 0.23 20.00 0.45 0.68 30.00 0.91 40.00 (CFM) 1.13 (CMM) cui.com 1.00 0.00 0.00 0.00 5.00 0.17 10.00 15.00 20.00 25.00 30.00 (CFM) 0.34 0.51 0.68 0.85 (CMM) For more information, please visit the product page. CUI Inc │ SERIES: CFM 60 │ DESCRIPTION: DC AXIAL FAN date 09/16/2013 │ page 4 of 6 MECHANICAL parameter conditions/description bearing system ball bearing min motor protection auto restart, polarity protection material UL94V-0 weight CFM-6010 models CFM-6015 models CFM-6025 models typ 28.0 40.2 66.9 MECHANICAL DRAWING units: mm (inches) CFM-6010 ōŢţŦŭ CFM-6015 ōŢţŦŭ cui.com max units g g g For more information, please visit the product page. CUI Inc │ SERIES: CFM 60 │ DESCRIPTION: DC AXIAL FAN date 09/16/2013 │ page 5 of 6 MECHANICAL DRAWING (CONTINUED) units: mm (inches) CFM-6025 ōŢţŦŭ cui.com For more information, please visit the product page. CUI Inc │ SERIES: CFM 60 │ DESCRIPTION: DC AXIAL FAN date 09/16/2013 │ page 6 of 6 REVISION HISTORY rev. description date 1.0 initial release 10/15/2012 1.01 corrected CFM-6010 drawing 09/16/2013 The revision history provided is for informational purposes only and is believed to be accurate. Headquarters 20050 SW 112th Ave. Tualatin, OR 97062 800.275.4899 Fax 503.612.2383 cui.com [email protected] CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.