Datasheet

For more information, please visit the product page.
date
10/15/2012
page
1 of 4
SERIES: CFM 70 │ DESCRIPTION: DC AXIAL FAN
FEATURES
•
•
•
•
70 x 70 mm frame
high fan speed for greater air flow
two ball bearing construction
auto restart protection standard on all models
RoHS
operating
voltage
rated
current
input
current
input
power
(Vdc)
(Vdc)
max
(A)
max
(A)
max
(W)
auto restart
tachometer
signal
rotation
detector
PWM control
signal
CFM-7010-13-10
12
6~13.8
0.22
0.27
3.24
x
-
-
-
CFM-7010-13-11
12
6~13.8
0.22
0.27
3.24
x
-
x
-
CFM-7010-13-20
12
6~13.8
0.22
0.27
3.24
x
x
-
-
CFM-7010-13-22
12
6~13.8
0.22
0.27
3.24
x
x
-
x
MODEL
rated
voltage
fan protection
PART NUMBER KEY
CFM-7010-13-XX-CXX
Base Number
Reserved for Custom
Configurations
Voltage Type
1 = 12 Vdc
Fan Speed
3 = high speed
cui.com
Fan Protection
10 = auto restart protection
11 = auto restart protection / rotation detector
20 = auto restart protection / tachometer signal
22 = auto restart protection / tachometer signal /
PWM control signal
For more information, please visit the product page.
CUI Inc │ SERIES: CFM 70 │ DESCRIPTION: DC AXIAL FAN
date 10/15/2012 │ page 2 of 4
SPECIFICATION
parameter
conditions/description
min
frame
depth
starting voltage
at 25°C, power on/off
rated speed
at 25°C, after 10 minutes
air flow
at 0 mm H2O, see performance curve
3,960
typ
max
mm
10
mm
6
Vdc
4,400
4,840
31.11
static pressure
at 0 CFM, see performance curve
4.17
noise
at 1 m
39.5
insulation resistance of frame
at 500 Vdc between frame and positive terminal
dielectric strength
at 500 Vac, 60 Hz, 1 minute between frame and
positive terminal
life expectancy
at 45°C, 15~65 RH
units
70
RPM
CFM
mmH2O
40.6
10
dBA
MΩ
5
mA
70,000
hours
operating temperature
-10
70
°C
humidity range
15
66
RH
RoHS
yes
0.18
(mm H2O)
(Inch H2O)
PERFORMANCE CURVE
4.50
4.00
0.14
0.11
0.07
3.50
3.00
2.50
2.00
1.50
0.04
1.00
0.50
0.00
0.00
0.00
0.00
10.00
0.23
20.00
0.45
0.68
cui.com
30.00
0.91
40.00 (CFM)
1.13 (CMM)
For more information, please visit the product page.
CUI Inc │ SERIES: CFM 70 │ DESCRIPTION: DC AXIAL FAN
date 10/15/2012 │ page 3 of 4
MECHANICAL
parameter
conditions/description
bearing system
ball bearing
min
motor protection
auto restart, polarity protection
material
UL94V-0
weight
typ
37.3
MECHANICAL DRAWING
units: mm (inches)
ōŢţŦŭ
cui.com
max
units
g
For more information, please visit the product page.
CUI Inc │ SERIES: CFM 70 │ DESCRIPTION: DC AXIAL FAN
date 10/15/2012 │ page 4 of 4
REVISION HISTORY
rev.
1.0
description
date
initial release
10/15/2012
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
[email protected]
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical
component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to
affect its safety or effectiveness.