Datasheet

G6C
PCB Power Relay
Miniature High Capacity Relays
with SPST-NO 10A and SPST-NO +
SPST-NC 8A
• SPST-NO 10A and SPST-NO + SPST-NC 8A for power switching and
output that satisfy the needs for space-saving.
• Small High-capacity Relays Compact: 20 × 15 × 10 mm (L × W × H).
• Low power consumption: 200 mW.
• Ultrasonically cleanable models is available.
• Exclusive P6C model for sockets is now available.
RoHS Compliant
■Model Number Legend
■Application Examples
G6C- @- @ @ @ @@-@-@- @-@
1
2
3 4 5
6
7
8
1. Relay Function
None: Single-side stable
U : Single-winding latching
K : Double-winding latching
2. Contact Form
11: SPST-NO (1a)
21: SPST-NO (1a) + SPST-NC (1b)
Ideal for output applications of control
equipments
9
6. Contact Material
None: Standard (Ag-alloy (Cd free))
FD : AgSnIn Contacts
(Suitable for DC inductive load
with high inrush current)
7. Approved Standards
US: UL/CSA
4. Enclosure rating
4: Fully sealed
7: Flux protection
8. Washability
None: Standard model
(not compatible with ultrasonically
cleanable models)
U : For ultrasonically cleanable
5. Terminal Shape
P: PCB terminals
Socket mounting Terminals
9. Mounting
None: Mounted directly to PCB
P6C : Mounted to Socket
3. Contact Type
1: Single
1
G
6
C
G6C
PCB Power Relay
■Ordering Information
●Standard Models (UL, CSA certified)
Relay
Function
Enclosure
rating
Single-side stable
Contact
form
SPST-NO
(1a)
Model
Rated coil
voltage
G6C-1117P-US
SPST-NO
(1a)
G
6
C
Model
3 VDC
5 VDC
5 VDC
−
G6CU-1117P-US
G6C-1114P-US
3 VDC
5 VDC
G6CK-1117P-US
6 VDC
12 VDC
12 VDC
24 VDC
24 VDC
24 VDC
3 VDC
3 VDC
3 VDC
5 VDC
G6CU-2117P-US
6 VDC
6 VDC
12 VDC
12 VDC
24 VDC
24 VDC
24 VDC
3 VDC
3 VDC
3 VDC
5 VDC
5 VDC
G6CU-1114P-US
6 VDC
5 VDC
G6CK-1114P-US
6 VDC
12 VDC
12 VDC
12 VDC
24 VDC
24 VDC
24 VDC
3 VDC
3 VDC
3 VDC
5 VDC
6 VDC
5 VDC
G6CU-2114P-US
6 VDC
100 pcs/
tray
5 VDC
G6CK-2117P-US
12 VDC
6 VDC
G6C-2114P-US
Model
Minimun
Rated coil packing unit
voltage
12 VDC
6 VDC
Fully sealed
SPST-NO
(1a) +
SPST-NC
(1b)
Rated coil
voltage
5 VDC
G6C-2117P-US
Double-winding latching
3 VDC
6 VDC
Flux protection
SPST-NO
(1a) +
SPST-NC
(1b)
Single-winding latching
100 pcs/
tray
5 VDC
G6CK-2114P-US
6 VDC
12 VDC
12 VDC
12 VDC
24 VDC
24 VDC
24 VDC
Note1.When ordering, add the rated coil voltage to the model number.
Example: G6C-1117P-US DC3
Rated coil voltage
However, the notation of the coil voltage on the product case as well as on the packing will be marked as @@ VDC.
Note2.Products with UL/CSA certification marks will be supplied for orders of standard models (-US models).
G6C-1117P
-US
CONTACT:
TV-5
10A 250VAC
24VDC
MADE IN 10A 30VDC
COIL:24VDC
JAPAN
G6C-2114P
-US
CONTACT:
TV-5
8A 250VAC
24VDC
MADE IN 8A 30VDC
COIL:24VDC
JAPAN
●Ultrasonically Cleanable Models (UL, CSA certified)
Relay
Function
Enclosure
rating
Single-side stable
Contact
form
SPST-NO
(1a)
Model
G6C-1114P-US-U
Rated coil
voltage
Double-winding latching
Rated coil
voltage
Model
−
−
5 VDC
5 VDC
5 VDC
6 VDC
−
G6CU-1114P-US
G6CK-1114P-US
12 VDC
24 VDC
−
24 VDC
−
−
−
−
−
−
G6CU-2114P-US
−
12 VDC
−
12 VDC
24 VDC
−
−
●Connecting Sockets (Sold Separately)
Applicable relays
Model
G6C-2114P-US-P6C
G6C-2117P-US-P6C
G6C-1114P-US-P6C
G6C-1117P-US-P6C
G6CU-2114P-US-P6C
G6CU-2117P-US-P6C
G6CU-1114P-US-P6C
G6CU-1117P-US-P6C
P6C-06P
G6CK-2114P-US-P6C
G6CK-2117P-US-P6C
G6CK-1114P-US-P6C
G6CK-1117P-US-P6C
P6C-08P
Removal Tool
P6B-Y1
Hold-down Clips
P6B-C2
Minimun packing unit
20 pcs/tube
1
Note 1. Use the G6C-@@@@P-US-P6C to mount to a P6C Socket.
2. When using by combining sockets, the rated current will be 5A due to its rated switching current.
100 pcs/
tray
5 VDC
G6CK-2114P-US
Note1.When ordering, add the rated coil voltage to the model number.
Example: G6C-1114P-US-U DC3
Rated coil voltage
However, the notation of the coil voltage on the product case as well as on the packing will be marked as @@ VDC.
Note2.Products with UL/CSA certification marks will be supplied for orders of standard models (-US models).
2
−
12 VDC
5 VDC
G6C-2114P-US-U
Model
Minimun
Rated coil packing unit
voltage
3 VDC
12 VDC
Fully sealed
SPST-NO
(1a) +
SPST-NC
(1b)
Single-winding latching
G6C-1117P
-US
CONTACT:
TV-5
10A 250VAC
24VDC
MADE IN 10A 30VDC
COIL:24VDC
JAPAN
G6C-2114P
-US
CONTACT:
TV-5
8A 250VAC
24VDC
MADE IN 8A 30VDC
COIL:24VDC
JAPAN
G6C
PCB Power Relay
■Ratings
Coil: 1-Pole, Single-side Stable Type (Including models for ultrasonically cleanable)
Item
Rated
current
(mA)
Rated voltage
3 VDC
Must operate Must release
voltage
voltage
(V)
(V)
Coil
resistance
(Ω)
67
Max.
voltage
(V)
Power
consumption
(mW)
% of rated voltage
45
5 VDC
40
125
6 VDC
33.3
180
12 VDC
16.7
720
24 VDC
8.3
2,880
70% max.
10% min.
160%
(at 23°C)
Approx. 200
Coil: Single-winding Latching Type (Including models for ultrasonically cleanable)
Item
Rated
current
(mA)
Rated voltage
Coil
resistance
(Ω)
3 VDC
67
45
5 VDC
40
125
6 VDC
33.3
180
12 VDC
16.7
720
24 VDC
8.3
2,880
Must set
voltage
(V)
Must reset
voltage
(V)
Max.
voltage
(V)
% of rated voltage
70% max.
70% max.
160%
(at 23°C)
Power consumption
Set coil
(mW)
Reset coil
(mW)
200
200
Coil: Double-winding Latching Type (Including models for ultrasonically cleanable)
Item
Rated current (mA)
Coil resistance (Ω)
Set coil
Reset coil
Set coil
Reset coil
3 VDC
93.5
93.5
5 VDC
56.0
56.0
6 VDC
46.7
46.7
129
129
12 VDC
23.3
23.3
514
514
24 VDC
11.7
11.7
2,056
2,056
Must set
voltage
(V)
Rated voltage
Must reset
voltage
(V)
Max.
voltage
(V)
Power consumption
% of rated voltage
32.1
Set coil
(mW)
Reset coil
(mW)
280
280
G
6
C
32.1
89.3
89.3
70% max.
70% max.
130%
(at 23°C)
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
2. The operating characteristics are measured at a coil temperature of 23°C.
3. The “Max. voltage” is the maximum voltage that can be applied to the relay coil.
Contact
Contact Form
Rated load
Item
SPST-NO (1a)
Inductive load
(cosφ = 0.4; L/R = 7 ms)
Resistive load
Inductive load
(cosφ = 0.4; L/R = 7 ms)
10 A (8 A) at 250 VAC
10 A (10 A) at 30 VDC
5 A (5 A) at 250 VAC
5 A (5 A) at 30 VDC
8 A (8 A) at 250 VAC
8 A (8 A) at 30 VDC
3.5 A (3.5 A) at 250 VAC
3.5 A (3.5 A) at 30 VDC
Contact type
Single
Contact material
Rated carry current
Ag-Alloy (Cd free)
10 A (10 A)
Max. switching voltage
Max. switching current
SPST-NO (1a) + SPST-NC (1b)
Resistive load
8 A (8 A)
380 VAC, 125 VDC
10 A (10 A)
8 A (8 A)
Note. The values shown in parentheses ( ) are for -FD models only.
3
G6C
PCB Power Relay
■Characteristics (Including models for ultrasonically cleanable)
Single-side Stable
Single-winding Latching Double-winding Latching
30 mΩ max.
10 ms max.
10 ms max.
20 ms (at 23°C)
20 ms (at 23°C)
−
−
1,000 MΩ min.
1,000 MΩ min.
1,000 MΩ min. (SPST-NO, SPST-NC)
−
−
1,000 MΩ min.
2,000 VAC 50/60Hz for 1min
1,000 VAC 50/60Hz for 1min
2,000 VAC 50/60Hz for 1min (SPST-NO, SPST-NC)
250 VAC 50/60Hz for
1min
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
1,000 m/s2
100 m/s2
50,000,000 operations min. (at 18,000 operations/hr)
100,000 operation min. (at 1,800 operations/hr under rated load)
10 mA at 5 VDC
-25°C to 70°C (with no icing or condensation)
5% to 85%
Approx. 5.6 g
−
−
Note. The given values are initial values.
*1. Measurement conditions: 5 VDC, 1 A, voltage
drop method.
*2. Testing conditions: measured with a 500 VDC
megohmmeter (at 250 VDC between set/reset
coil).
*3. This value was measured at a switching
frequency of 120 operations/min.
G6C-1114P-FD-US
G6C-1117P-FD-US
Switching current (A)
50
30
AC resistive load
10
7
5
3
DC resistive load
DC inductive load
(L/R = 7 ms)
1
0.7
0.5
AC inductive
load
(cosφ = 0.4)
50
30
AC resistive load
10
8
5
3
2
DC resistive load
1
0.7
0.5
AC inductive
load
(cosφ = 0.4)
50
30
AC resistive load
10
8
5
3
2
0.3
0.3
0.2
0.2
0.2
0.1
0.1
3
5 7 10
30 50 100
250 380 1,000
Switching voltage (V)
G6C-2114P-FD-US
G6C-2117P-FD-US
50
30
AC resistive load
10
8
5
3
2
AC inductive
load
(cosφ = 0.4)
DC resistive load
1
0.7
0.5
DC inductive load
(L/R = 7 ms)
0.3
0.2
0.1
1
3
5 7 10
30 50 100
250 380 1,000
Switching voltage (V)
DC resistive load
DC inductive load
(L/R = 7 ms)
1
0.7
0.5
DC inductive load
(L/R = 7 ms)
0.3
1
4
G6C-2114P-US
G6C-2117P-US
Switching current (A)
● Maximum Switching Capacity
G6C-1114P-US
G6C-1117P-US
Switching current (A)
■Engineering Data
Switching current (A)
G
6
C
Item
Classification
Contact resistance *1
Operate (set) time
Release (reset) time
Min. set pulse width
Min. reset pulse width
Between coil and
contacts
Between contacts of the
same polarity
Insulation
resistance *2
Between contacts of
different polarity
Between set and reset
coils
Between coil and
contacts
Between contacts of the
same polarity
Dielectric
strength
Between contacts of
different polarity
Between set and reset
coils
Destruction
Vibration
resistance
Malfunction
Destruction
Shock
resistance
Malfunction
Mechanical
Durability
Electrical
Failure rate (P level) (reference value) *3
Ambient operating temperature
Ambient operating humidity
Weight
AC inductive
load
(cosφ = 0.4)
0.1
1
3
5 7 10
30 50 100
250 380 1,000
Switching voltage (V)
1
3
5 7 10
30 50 100
250 380 1,000
Switching voltage (V)
G6C
● Durability
G6C-1114P-US, G6C-2114P-US
G6C-1117P-US, G6C-2117P-US
G6C-1114P-FD-US, G6C-2114P-FD-US
G6C-1117P-FD-US, G6C-2117P-FD-US
Durability (× 104 operations)
Durability (x 104 operations)
PCB Power Relay
500
300
G6C-2114P-US
G6C-2117P-US
250 VAC resistive
30 VDC resistive
100
50
G6C-1114P-US
G6C-1117P-US
250 VAC resistive
30 VDC resistive
30
10
300
100
G6C-2114P-FD-US
G6C-2117P-FD-US
250 VAC resistive
G6C-1114P-FD-US
30 VDC resistive
G6C-1117P-FD-US
250 VAC resistive
G6C-1114P
-FD-US
G6C-1117P
-FD-US
30 VDC resistive
50
30
10
G6C-2114P-US
5 G6C-2117P-US
250 VAC inductive
3 (cosφ = 0.4)
30 VDC inductive
(L/R = 7 ms)
1
500
0
1
2
3
4
G6C-1114P-US
G6C-1117P-US
250 VAC inductive
(cosφ = 0.4)
30 VDC inductive
(L/R = 7 ms)
5
6
7
8
9
5 G6C-2114P-FD-US
G6C-2117P-FD-US
3 250 VAC inductive
(cosφ = 0.4)
30 VDC inductive
(L/R = 7 ms)
1
0 1
2
3
4
10 11
G6C-1114P-FD-US
G6C-1117P-FD-US
250 VAC inductive
(cosφ = 0.4)
30 VDC inductive
(L/R = 7 ms)
5
6
Switching current (A)
8
9
10 11
● Ambient Temperature vs Must
Operate and Must Release voltages
Must Operate and Must Release voltages (%)
● Ambient Temperature vs.
Maximum Coil Voltage
Maximum coil voltage (%)
7
Switching current (A)
200
180
160
140
130
120
100
100
Must operate voltage
Must release voltage
max.
X
Sample:
G6C-114P-US
Number of Relays:
80 5 pcs
min.
G
6
C
60
40
max.
X
min.
20
80
60
10
20 23 30
40
50
60
70
80
0
-40
90
-20
0
20
Ambient temperature (°C)
40
60
80
Ambient temperature (°C)
Note. The maximum coil voltage refers to the
maximum value in a varying range of
operating power voltage, not a continuous
voltage.
● Shock Malfunction
Y
Magnetic Interference (between Relays)
De-energized
(b contact)
600
Z
600
200
X
600
400
400
Z
600
200
400
200
200
600
400
400
X
600
Y
200
Z'
600
200
400
200
200
200
400
Change rate on the basis of rated value (OV) (%)
Energized
(a contact)
200
500
600
X'
400
200
Z'
600
200
400
600
X'
400
400
Shock direction
600
Y'
Unit: m/s2
600
Y'
Unit: m/s2
Y
X
X'
Z
Z'
Y'
3
2
1
max.
X
min.
0
l2
Sample
-1
l1
-2
(Mounting pitch)
-3
Initial
l1=2.54a
l2=5.08a
l1=5.08a
l2=7.62a
l1=7.62a
l2=10.16a
(coil)
Sample: G6C-2114P-US DC24V
Number of Relays: 6 pcs
Test conditions: Shock is applied in ±X, ±Y, and ±Z
directions three times each with without energizing the
Relays to check the number of malfunctions.
Requirement: 100 m/s2
5
G6C
PCB Power Relay
■Dimensions
Flux Protection Model
G6C-@117P-US
Terminal
Arrangement/
Internal Connections
(Bottom View)
PCB Mounting Holes
(Bottom View)
Tolerance: ±0.1
1-pole
2.54
Four, 1.1-dia. holes
1-pole
2.54
1
20 max.
(19.9)*
(2.4)
10.16
4
0.9<1.0>
1.11
8
3
4
6
5
+
7.62
(1.1)
3.5
0.9<1.0>
10.16
7.62
* Average value
3
15 max.
(14.9)*
10 max.
0.3 (9.9)*
0.65<0.7>
−
2-pole
0.5
<0.4>
2.54
Six, 1.1-dia. holes
10.16
2-pole
2.54
1
Dimensions in pointed brackets < > are for the
Relay mounted to Socket(-P6C).
(2.4)
10.16
7.62
(1.1)
8
−
+
Note: Check carefully the coil
polarity of the Relay.
Note: Orientation mark is indicated as follows:
G
6
C Fully Sealed Model
G6C-@114P-US
PCB Mounting Holes
1-pole (Bottom View)
Tolerance: ±0.1
2.54
Terminal Arrangement/
Internal Connections
(Bottom View)
Four, 1.1-dia. holes
1-pole
2.54
1
20 max.
(19.9)*
15 max.
(14.9)*
(2.4)
10.16
10 max.
0.3 (9.9)*
8
−
3
4
3
4
6
5
+
7.62
(1.1)
2-pole
3.5
0.65<0.7>
0.9<1.0>
10.16
7.62
* Average value
0.9<1.0>
1.11
2.54
0.5
<0.4>
10.16
Six, 1.1-dia. holes
1
Dimensions in pointed brackets < > are for the
Relay mounted to Socket(-P6C).
(2.4)
10.16
7.62
(1.1)
6
2-pole
2.54
8
−
+
Note: Check carefully the coil
polarity of the Relay.
G6C
PCB Power Relay
Flux Protective
Single-winding Latching Model
G6CU-@117P-US
PCB Mounting Holes
(Bottom View)
1-pole Tolerance: ±0.1
Terminal
Arrangement/Internal
Connections
2.54
Four, 1.1-dia. holes
1-pole
2.54
1
− +
3
4
SR
20 max.
(19.9)*
15 max.
(14.9)*
(2.4)
10 max.
0.3 (9.9)*
10.16
8
+ −
S: Set coil
R: Reset coil
7.62
(1.1)
3.5
0.65<0.7>
0.9<1.0>
0.9<1.0>
10.16
7.62
* Average value
1.11
2-pole
0.5
<0.4>
2.54
10.16
Six, 1.1-dia. holes
2-pole
2.54
1
Dimensions in pointed brackets < > are for the
Relay mounted to Socket(-P6C).
− +
3
4
6
5
SR
(2.4)
10.16
7.62
(1.1)
Fully Sealed Model
Single Latching Models
G6CU-@114P-US
8
+ −
Note: Check carefully the coil
polarity of the Relay.
PCB Mounting Holes
(Bottom View)
1-pole Tolerance: ±0.1
Terminal
Arrangement/Internal
Connections
G
6
C
2.54
Four, 1.1-dia. holes
1-pole
2.54
1
− +
3
4
SR
20 max.
(19.9)*
15 max.
(14.9)*
(2.4)
10 max.
0.3 (9.9)*
10.16
8
+ −
S: Set coil
R: Reset coil
7.62
(1.1)
3.5
0.65<0.7>
0.9<1.0>
10.16
7.62
* Average value
0.9<1.0>
1.11
2-pole
0.5
<0.4>
2.54
10.16
Six, 1.1-dia. holes
2-pole
2.54
1
Dimensions in pointed brackets < > are for the
Relay mounted to Socket(-P6C).
− +
3
4
6
5
SR
(2.4)
10.16
7.62
(1.1)
8
+ −
Note: Check carefully the coil
polarity of the Relay.
Note: Orientation marks are indicated as follows:
7
G6C
PCB Power Relay
Flux Protective
Double-winding Latching Model
G6CK-@117P-US
PCB Mounting Holes
(Bottom View)
1-pole Tolerance: ±0.1
Terminal Arrangement/
Internal Connections
(Bottom View)
2.54
Six, 1.1-dia. holes
1-pole
2.54
1
−
2
S
20 max.
(19.9)*
15 max.
(14.9)*
(2.4)
2.54
10 max.
0.3 (9.9)*
0.65<0.7>
0.9
<1.0>
0.9<1.0>
10.16
7.62
* Average value
1.11
+
3
4
3
4
6
5
R
7
+
S: Set coil
R: Reset coil
7.62
(1.1)
2-pole
3.5
0.9<1.0>
7.62
8
−
0.5
<0.4>
2.54
Eight, 1.1-dia. holes
2-pole
10.16
2.54
1
Dimensions in pointed brackets < > are for the
Relay mounted to Socket(-P6C).
−
2
S
(2.4)
7.62
7.62
2.54
Fully Sealed
G Double-winding Latching Model
6 G6CK-@114P-US
C
(1.1)
8
+
−
R
7
+
Note: Check carefully the coil
polarity of the Relay.
Terminal Arrangement/
Internal Connections
(Bottom View)
PCB Mounting Holes
1-pole (Bottom View)
Tolerance: ±0.1
2.54
Six, 1.1-dia. holes
1-pole
2.54
1
−
2
S
20 max.
(19.9)*
15 max.
(14.9)*
(2.4)
10 max.
0.3 (9.9)*
0.65<0.7>
0.9
<1.0>
0.9<1.0>
10.16
7.62
* Average value
7.62
3.5
0.9<1.0>
1.11
(1.1)
4
3
4
6
5
R
7
+
2-pole
0.5
<0.4>
2.54
Eight, 1.1-dia. holes
10.16
2-pole
2.54
1
Dimensions in pointed brackets < > are for the
Relay mounted to Socket(-P6C).
−
2
S
(2.4)
7.62
2.54
8
+
3
S: Set coil
R: Reset coil
7.62
2.54
8
−
7.62
(1.1)
8
+
−
R
7
+
Note: Check carefully the coil
polarity of the Relay.
G6C
PCB Power Relay
■Connecting Sockets Dimensions
Socket for single-winding latching/single-side a table Models
P6C-06P
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
23.2max.
(23)*
15max.
(14.9)*
Six, 1.1-dia. holes
2.54
3.1
2.54
(2.4)
10.8max.
(10.6)* 7.5
3.5
0.8
10.16
* Average value
0.4
7.62
(2.61)
10.16
7.62
10.16±0.1
Socket for double-winding latching Models
P6C-08P
23.2max.
(23)*
PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
15max.
(14.9)*
3.1
G
6
C
Eight, 1.1-dia. holes
2.54
2.54
(2.4)
10.8max.
(10.6)* 7.5
3.5
0.8
* Average value
2.54
7.62
7.62
0.4
10.16±0.1
7.62
(2.61)
7.62
2.54
Note: Orientation marks are indicated as follows:
9
G6C
PCB Power Relay
■Removal Tool
■Hold-down Clips
P6B-Y1
P6B-C2
■Approved Standards
●The rated values approved by each of the safety standards may be different from the performance characteristics individually defined
in this catalog.
UL Recognized
Model
(File No. E41643)
Number of
poles
G6C ( )
2
CSA Certified
Model
G6C ( )
2
Coil ratings
Coil ratings
1
3, 5, 6, 12, 24 VDC
2
• Single-stable:
3, 5, 6, 12, 24 VDC
EN/IEC, TÜV Certified
Number of
poles
1
G6C ( )
2
10
6,000
30,000
6,000
30,000
Number of test
operations
6,000
(Certificate No. 40014439)
Number of
poles
G6C ( )
Contact ratings
10 A, 250 VAC 80°C
10 A, 30 VDC 80°C
1/6 HP 125 VAC, 1/4 HP, 125 VAC 80°C
1/3 HP 250 VAC, 1/4 HP, 250 VAC 80°C
600 W, 120 VAC, (Tungsten) 80°C
530 VA, 20~265 VAC Max 2A (Pilot Duty) 80°C
43.2 VA, 30 VDC (Pilot Duty) 80°C
3 to 24 VDC
8 A, 250 VAC 80°C
8 A, 30 VDC 80°C
1/6 HP, 125 VAC, 1/4 HP, 125 VAC 80°C
1/4 HP, 250 VAC 80°C
600 W, 120 VAC (Tungsten) 80°C
530 VA, 20~265 VAC Max 2A (Pilot Duty) 80°C
43.2 VA, 30 VDC (Pilot Duty) 80°C
EN/IEC, VDE Certified
Model
Number of test
operations
(File No. LR31928)
Number of
poles
1
Model
Contact ratings
10 A, 250 VAC 80°C
10 A, 30 VDC 80°C
1/6 HP 250 VAC, 1/4 HP, 125 VAC 80°C
1/3 HP 250 VAC, 1/4 HP, 250 VAC 80°C
600 W, 120 VAC, (Tungsten) 80°C
530 VA, 20~265 VAC Max 2A (Pilot Duty) 80°C
43.2 VA, 30 VDC (Pilot Duty) 80°C
12 LRA, 2.2 FLA 30 VDC 80°C
3 to 24 VDC
8 A, 250 VAC 80°C
8 A, 30 VDC 80°C
1/6 HP, 125 VAC, 1/4 HP, 125 VAC 80°C
1/4 HP, 250 VAC 80°C
600 W, 120 VAC (Tungsten) 80°C
530 VA, 20~265 VAC Max 2A (Pilot Duty) 80°C
43.2 VA, 30 VDC (Pilot Duty) 80°C
12 LRA, 2.2 FLA, 30 VDC 80°C
1
G
6
C
Coil ratings
Contact ratings
10 A, 250 VAC (cosφ = 1) 40°C
5 A, 250 VAC (cosφ = 0.4) 40°C
7 A, 250 VAC (cosφ = 1) 40°C
3.5 A, 250 VAC (cosφ = 0.4) 40°C
Approved
switching
operations
20,000
(Registration No. R50158249)
Coil ratings
• Single-stable:
3, 5, 6, 12, 24 VDC
• Latching:
3, 5, 6, 12, 24 VDC
Contact ratings
10 A, 250 VAC (cosφ = 1) 40°C
5 A, 250 VAC (cosφ = 0.4) 40°C
10 A, 30 VDC (L/R = 0 ms) 40°C
8 A, 250 VAC (cosφ = 1) 40°C
3.5 A, 250 VAC (cosφ = 0.4) 40°C
8 A, 30 VDC (L/R = 0 ms) 40°C
Approved
switching
operations
20,000
G6C
PCB Power Relay
■Precautions
●Please refer to “PCB Relays Common Precautions” for correct use.
Correct Use
●Mounting
• Do not reverse the polarity of the coil
(+, −).
• When mounting more than two relays
side by side, keep the gap between
Relays as shown below to ensure a
good heat dissipation. It may result in
malfunction if heat is not dissipated
smoothly from the Relay.
2.54 mm ×
3 pitch min.
between
terminals
2.54 mm × 2 pitch min. between terminals
●Sockets
17 mm max. for sockets
7.5 mm
• When mounting the Relay, make sure
to insert the Relay terminals
perpendicularly and correctly into the
socket contact pin.
• Hold-down clips (for mounting and
removal) are also available.
• The P6C model has a flux-resistant
construction. Do not wash it down with
water.
• The max. carry current of sockets is 5A.
●Double-winding Latching Circuit
• It is recommended to perform wiring of
No.1 and No.2 of the negative (-)
terminal as COM wiring, in order to
improve the operation stability for
Double-winding Latching.
●Using SPDT contact of the
SPST-NO+SPST-NC Relay
• Do not construct a circuit so that
overcurrent and burning occur if the
NO, NC and SPDT contacts are shortcircuited with the SPST-NO+SPST-NC
Relay. Arcing may generate shortcircuiting between contacts if there is
short-circuiting because of conversion
to the MBB contact caused by
asynchronous operation of the NO and
NC contacts, the interval between the
NO and NC contacts is small, or a
large current is left open.
●Other precautions
• This Relay is a Power Relay which is
suitable for power load switching. Do
not use the G6C for signal purposes
such as micro load switching under
10 mA.
(+)
+
8
−
1
+
7
−
2
S
R
COM
· Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
· Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.
OMRON Corporation
Electronic and Mechanical Components Company
Contact: www.omron.com/ecb
Cat. No. K018-E1-09
0316(0207)(O)
11
G
6
C