OMRON G6CU-2114P

5/10/07
15:39
Page 106
Text Power Relay – G6C
PCB
Text Power Relay – G5CA
PCB
Precautions
■
Precautions for Correct Use
Installation
Make sure that sufficient space is provided between relays when
installing two or more relays side by side to facilitate heat
dissipation. Insufficient heat dissipation may result in the relay
malfunctioning.
Charged Terminals
The section marked with dotted circles (indicated by arrows) in
the following diagram includes the charged terminals of the relay.
When the relay is mounted on a PCB, make sure that there are no
metal patterns on the section of the PCB facing the portion of the
relay shaded in the following diagram.
SPST-NO Type Breaks 10-A Loads;
SPST-NO + SPST-NC Type Breaks
8-A Load
Power Relays
Omron 08 Cat 1-302
■ ROHS compliant
■ Compact: 20 x 15 x 10 mm (L x W x H).
■ Low power consumption: 200 mW.
■ Flux protection or fully sealed construction
available.
■ Unique moving loop armature reduces relay
size, magnetic interference, and contact
bounce.
■ Single- and double-winding latching types
Quick-connect Terminal Connections
• Do not pass current through the PCB of the load
contactterminals (quick-connect terminals).
• The terminals are compatible with Faston receptacle #187
and are suitable for positive-lock mounting.
Use only Faston terminals with the specified numbers. Select
leads for connecting Faston receptacles with wire diameters
that are within the allowable range for the load current. Do not
apply excessive force to the terminals when mounting or
dismounting the Faston receptacle.
Insert and remove terminals carefully one at a time. Do not insert
terminals on an angle, or insert/remove multiple terminals at the
same time.
The following positive-lock connectors made by AMP are
recommended. Contact the manufacturer directly for details on
connectors including availability.
Type
also available
Other Precautions
• The G5CA is a power relay designed for applications switching
power loads such as heaters in electric household appliances.
Do not use the G5CA to switch micro loads less than 100 mA,
such as in signal applications.
• Use fully sealed models if the relays will require washing.
Fluxprotection models may malfunction or the relay's
performance may be otherwise adversely affected if cleaning
fluid enters the relay.
Type Receptacle terminals (See note.)
#187 terminals (width: 4.75 mm) AMP 170330-1 (170324-1)
AMP 170331-1 (170325-1)
AMP 170332-1 (170326-1)
Positive housing
AMP
AMP
AMP
AMP
172074-1
172074-4
172074-5
172074-6
(natural color)
(yellow)
(green)
(blue)
Ordering Information
Classification
Contact form
Single-side stable
Straight PCB
SPST-NO
Self-clinching PCB
Flux protection
Fully sealed
Flux protection
G6C-1117P-US
G6C-1114P-US
G6C-1117C-US
Fully sealed
G6C-1114C-US
SPST-NO + SPST-NC G6C-2117P-US
G6C-2114P-US
G6C-2117C-US
G6C-2114C-US
Single-winding
latching
SPST-NO
G6CU-1114P-US
G6CU-1117C-US
G6CU-1114C-US
SPST-NO + SPST-NC G6CU-2117P-US
G6CU-2114P-US
G6CU-2117C-US
G6CU-2114C-US
Double-winding
latching
SPST-NO
G6CK-1117P-US
G6CK-1114P-US
G6CK-1117C-US
G6CK-1114C-US
SPST-NO + SPST-NC G6CK-2117P-US
G6CK-2114P-US
G6CK-2117C-US
G6CK-2114C-US
G6CU-1117P-US
Note: When ordering, add the rated coil voltage to the model number.
Example: G6C-1117P-US 12 VDC
Rated coil voltage
Model Number Legend
Note: The numbers shown in parentheses are for air-feeding
G6C
1
2
3
4 5
VDC
6
1. Relay Function
None: Single-side stable
U:
Single-winding latching
K:
Double-winding latching
2. Contact Form
11:
SPST-NO
21:
SPST-NO + SPST-NC
7
3. Contact Type
1: Standard
4. Enclosure Ratings
7: Flux protection
4: Fully sealed
5. Terminals
P: Straight PCB
C: Self-clinching PCB
6. Approved Standards
US: UL/CSA certified
7. Rated Coil Voltage
3, 5, 6, 12, 24 VDC
ALL DIMENSIONS SHOWN ARE IN MILLIMETRES.
To convert millimetres into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
CAT. No. J151-E2-02A-X
106
107
5/10/07
15:39
Page 108
Text Power Relay – G6C
PCB
Text Power Relay – G6C
PCB
■
Accessories (Order Separately)
Double-winding Latching Type
Back Connecting Sockets
Applicable relay
G6C(U)-1114P-US
G6C(U)-1117P-US
G6C(U)-2114P-US
G6C(U)-2117P-US
G6CK-1114P-US
G6CK-1117P-US
G6CK-2114P-US
G6CK-2117P-US
Back connecting socket*
P6C-06P
Removal Tool
P6B-Y1
Hold-down Clips
P6B-C2
3 VDC
5 VDC
6 VDC
12 VDC
Set coil
Rated current
93.5 mA
56.0 mA
46.7 mA
23.3 mA
11.7 mA
Coil resistance
32.1 Ω
89.3 Ω
129 Ω
514 Ω
2,056 Ω
Reset coil
P6C-08P
*Not applicable to the self-clinching type.
The operating current for the socket is 5 A max
Specifications
■
Rated voltage
Coil Rating
24 VDC
Coil inductance
Armature OFF
0.03
0.07
0.10
0.37
1.56
(H) (ref. value)
Armature OFF
0.02
0.06
0.08
0.32
1.18
Rated current
93.5 mA
56.0 mA
46.7 mA
23.3 mA
11.7 mA
Coil resistance
32.1 Ω
89.3 Ω
129 Ω
514 Ω
2,056 Ω
Coil inductance
Armature OFF
0.03
0.08
0.12
0.47
1.46
(H) (ref. value)
Armature OFF
0.02
0.07
0.10
0.38
1.13
Must set voltage
70% max. of rated voltage
Must reset voltage
70% min. of rated voltage
Max. voltage
130% of rated voltage (at 23°C)
Power consumption
Set coil: Approx. 280 mW
Reset coil: Approx. 280 mW
Power Relays
Omron 08 Cat 1-302
Single-side Stable Type
Rated voltage
3 VDC
5 VDC
6 VDC
12 VDC
24 VDC
Rated current
67 mA
40 mA
33.3 mA
16.7 mA
8.3 mA
Coil resistance
45 Ω
125 Ω
180 Ω
720 Ω
2,880 Ω
Coil inductance Armature OFF 0.078
0.22
0.36
1.32
4.96
Armature OFF 0.067
0.18
0.29
1.13
4.19
(H) (ref. value)
Must operate voltage
70% max. of rated voltage
Must release voltage
10% min. of rated voltage
Max. voltage
160% of rated voltage (at 23°C)
Power consumption
Approx. 200 mW
Single-side Latching Type
Rated voltage
3 VDC
5 VDC
6 VDC
12 VDC
24 VDC
Rated current
67 mA
40 mA
33.3 mA
16.7 mA
8.3 mA
Coil resistance
45 Ω
125 Ω
180 Ω
720 Ω
2,880 Ω
Coil inductance Armature OFF 0.09
0.25
0.36
1.75
5.83
Armature OFF 0.06
0.20
0.24
1.17
3.84
(H) (ref. value)
Must operate voltage
70% max. of rated voltage
Must release voltage
70% min. of rated voltage
Max. voltage
160% of rated voltage (at 23°C)
Power consumption
Approx. 200 mW
108
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
2. Operating characteristics are measured at a coil temperature of 23°C.
3. The minimum pulse width of the set and reset voltage is 20 ms.
■
Contact Ratings
Item
SPST-NO
SPST-NO+SPST-NC
Load
Resistive load
(cosφ = 1)
Inductive load
Resistive load
(cosφ = 0.4; L/R = 7 ms) (cosφ = 1)
Inductive load
cosφ = 0.4; L/R = 7 ms)
Rated load
10 A at 250 VAC;
10A at 30 VDC
5 A at 250 VAC;
5 A at 30 VDC
3.5 A at 250 VAC;
3.5 A at 30 VDC
Contact material
AgNi (FD type = AgSnIn)
Rated carry current
10 A
Max. switching voltage
380 VAC, 125 VDC (the case of latching 250 VAC, 125 VDC)
Max. switching current
10 A
Max. switching power
2,500 VA, 300 W
Failure rate (reference value)
10 mA at 5 VDC
8A at 250 VAC;
8A at 30 VDC;
8A
8A
1,250 VA, 220 W
2,000 VA, 240 W
875 VA, 170 W
Note: P level: λ60 = 0.1 x 10-6/operation
109
5/10/07
15:39
Page 108
Text Power Relay – G6C
PCB
Text Power Relay – G6C
PCB
■
Accessories (Order Separately)
Double-winding Latching Type
Back Connecting Sockets
Applicable relay
G6C(U)-1114P-US
G6C(U)-1117P-US
G6C(U)-2114P-US
G6C(U)-2117P-US
G6CK-1114P-US
G6CK-1117P-US
G6CK-2114P-US
G6CK-2117P-US
Back connecting socket*
P6C-06P
Removal Tool
P6B-Y1
Hold-down Clips
P6B-C2
3 VDC
5 VDC
6 VDC
12 VDC
Set coil
Rated current
93.5 mA
56.0 mA
46.7 mA
23.3 mA
11.7 mA
Coil resistance
32.1 Ω
89.3 Ω
129 Ω
514 Ω
2,056 Ω
Reset coil
P6C-08P
*Not applicable to the self-clinching type.
The operating current for the socket is 5 A max
Specifications
■
Rated voltage
Coil Rating
24 VDC
Coil inductance
Armature OFF
0.03
0.07
0.10
0.37
1.56
(H) (ref. value)
Armature OFF
0.02
0.06
0.08
0.32
1.18
Rated current
93.5 mA
56.0 mA
46.7 mA
23.3 mA
11.7 mA
Coil resistance
32.1 Ω
89.3 Ω
129 Ω
514 Ω
2,056 Ω
Coil inductance
Armature OFF
0.03
0.08
0.12
0.47
1.46
(H) (ref. value)
Armature OFF
0.02
0.07
0.10
0.38
1.13
Must set voltage
70% max. of rated voltage
Must reset voltage
70% min. of rated voltage
Max. voltage
130% of rated voltage (at 23°C)
Power consumption
Set coil: Approx. 280 mW
Reset coil: Approx. 280 mW
Power Relays
Omron 08 Cat 1-302
Single-side Stable Type
Rated voltage
3 VDC
5 VDC
6 VDC
12 VDC
24 VDC
Rated current
67 mA
40 mA
33.3 mA
16.7 mA
8.3 mA
Coil resistance
45 Ω
125 Ω
180 Ω
720 Ω
2,880 Ω
Coil inductance Armature OFF 0.078
0.22
0.36
1.32
4.96
Armature OFF 0.067
0.18
0.29
1.13
4.19
(H) (ref. value)
Must operate voltage
70% max. of rated voltage
Must release voltage
10% min. of rated voltage
Max. voltage
160% of rated voltage (at 23°C)
Power consumption
Approx. 200 mW
Single-side Latching Type
Rated voltage
3 VDC
5 VDC
6 VDC
12 VDC
24 VDC
Rated current
67 mA
40 mA
33.3 mA
16.7 mA
8.3 mA
Coil resistance
45 Ω
125 Ω
180 Ω
720 Ω
2,880 Ω
Coil inductance Armature OFF 0.09
0.25
0.36
1.75
5.83
Armature OFF 0.06
0.20
0.24
1.17
3.84
(H) (ref. value)
Must operate voltage
70% max. of rated voltage
Must release voltage
70% min. of rated voltage
Max. voltage
160% of rated voltage (at 23°C)
Power consumption
Approx. 200 mW
108
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
2. Operating characteristics are measured at a coil temperature of 23°C.
3. The minimum pulse width of the set and reset voltage is 20 ms.
■
Contact Ratings
Item
SPST-NO
SPST-NO+SPST-NC
Load
Resistive load
(cosφ = 1)
Inductive load
Resistive load
(cosφ = 0.4; L/R = 7 ms) (cosφ = 1)
Inductive load
cosφ = 0.4; L/R = 7 ms)
Rated load
10 A at 250 VAC;
10A at 30 VDC
5 A at 250 VAC;
5 A at 30 VDC
3.5 A at 250 VAC;
3.5 A at 30 VDC
Contact material
AgNi (FD type = AgSnIn)
Rated carry current
10 A
Max. switching voltage
380 VAC, 125 VDC (the case of latching 250 VAC, 125 VDC)
Max. switching current
10 A
Max. switching power
2,500 VA, 300 W
Failure rate (reference value)
10 mA at 5 VDC
8A at 250 VAC;
8A at 30 VDC;
8A
8A
1,250 VA, 220 W
2,000 VA, 240 W
875 VA, 170 W
Note: P level: λ60 = 0.1 x 10-6/operation
109
5/10/07
15:39
Page 110
Text Power Relay – G6C
PCB
Text Power Relay – G6C
PCB
Characteristics
Approved Standards (continued)
CSA C22.2 No.14 (File No. LR31928)
■
Contact resistance
30 mΩ max.
Operate (set) time
10 ms max. (mean value: approx. 5 ms)
Release (reset) time
10 ms max. (mean value: approx. 2 ms; latching types: mean value: approx. 5 ms)
Bounce Time
Operate: 5 ms max.
Release: 5 ms max.
Min. set/reset signal width
Latching type: 20 ms (at 23˚C)
Max. switching frequency
Mechanical: 18,000 operations/hr
Electrical: 1,800 operations/hr (under rated load)
Insulation resistance
1,000 MΩ min. (at 500 VDC, at 250 VDC between set coil and reset coil)
Dielectric strength
2,000 VAC, 50/60 Hz for 1 min between coil and contacts
2,000 VAC, 50/60 Hz for 1 min between contacts of different polarity
1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity
250 VAC, 50/60 Hz for 1 min between set and reset coils
Insulation
Distance
Model
Contact form
Coil rating
Contact rating
G6C-1114P-US
G6C-1114C-US
G6C-1117P-US
G6C-1117C-US
SPST-NO
3 to 60 VDC
10 A, 250 VAC (general use)
10 A, 30 VDC (resistive load)
1/6 hp, 125 VAC
1/4 hp, 125 VAC
1/4 hp, 250 VAC
1/3 hp, 250 VAC
TV-5
600 W, 120 VAC (tungsten)
G6C-2114P-US
G6C-2114C-US
G6C-2117P-US
G6C-2117C-US
SPST-NO + SPST-NC
3 to 60 VDC
8 A, 250 VAC (general use)
8 A, 30 VDC (resistive load)
1/6 hp, 125 VAC
1/4 hp, 125 VAC
1/4 hp, 250 VAC
TV-5
600 W, 120 VAC (tungsten)
Creepage (Typ) 5.5 mm
Clearance (Typ) 5.5 mm
VDE (Approval No. 2413) EN61810-1
175 V
Impulse withstand voltage
6.000 V (1.2 x 50 µs) between coil and contacts (latching types: 4,500 V, 1.2 50 µs)
Vibration resistance
Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Malfunction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Shock resistance
Destruction: 1,000 m/s2
Malfunction: 100 m/s2
Ambient temperature
Operating: -25˚C to 70˚C (with no icing)
Ambient humidity
Operating: 5% to 85%
Endurance
Mechanical: 50,000,000 operations min. (at 18,000 operations/hr)
Electrical: 100,000 operations min. (at 1,800 operations/hr)
Weight
Approx. 5.6 g
Approved Standards
UL508 (File No. E41643)
G6C-2114P-US
G6C-2114C–US
G6C-2117P-US
G6C-2117C-US
SPST-NO + SPST-NC
Contact rating
Number of test
operations
G6C-1114P-US
G6C-1114C-US
G6C-1117P-US
G6C-1117C-US
SPST-NO
3, 12, 24VDC
10A, 250VAC (cosφ = 1)
5A, 250VAC (cosφ = 0.4)
100,000
G6C-2114P-US
G6C-2114C-US
G6C-2117P-US
G6C-2117C-US
SPST-NO+SPST-NC Single-stable: 3, 5,
12, 24VDC
Latching: 5VDC
G6CU-2117P-VD: 3VDC
7A, 250VAC (cosφ = 1)
3.5A, 250VAC (cosφ = 0.4)
100,000
Engineering Data
Maximum Switching Power
SPST-NO
Coil rating
3 to 60 VDC
Contact rating
10 A, 250 VAC (general use)
10 A, 30 VDC (resistive load)
1/6 hp, 125 VAC
1/4 hp, 125 VAC
1/4 hp, 250 VAC
1/3 hp, 250 VAC
TV-5
600 W, 120 VAC (tungsten)
530 VA, 20 to 265 VAC, 2 A max. (pilot duty)
43.2 VA, 30 VDC (pilot duty)
12LRA, 2.2FLA, 30 VDC (30,000 cycle)
8 A, 250 VAC (general use)
8 A, 30 VDC (resistive load)
1/6 hp, 125 VAC
1/4 hp, 125 VAC
1/4 hp, 250 VAC
TV-5
600 W, 120 VAC (tungsten)
Endurance
SPST-NO + SPST-NC
AC inductive load
(cosφ = 0.4)
AC resistive
load
DC inductive load
(L/R = 7 ms)
DC resistive
load
Switching voltage (V)
Switching current (A)
SPST-NO
Coil rating
Switching current (A)
G6C-1114P-US
G6C-1114C-US
G6C-1117P-US
G6C-1117C-US
Contact form
Contact form
■
■
Model
Model
AC inductive load
(cosφ = 0.4)
AC resistive load
DC inductive load
(L/R = 7 ms)
DC resistive
load
Endurance (x10 3 operations)
Tracking Resistance (CTI)
Switching voltage (V)
G6C-2114P-US
250-VAC resistive
30-VDC resistive
G6C-1114P-US
250-VAC resistive
30-VDC resistive
G6C-2114P-US
250-VAC induc
tive (cosφ = 0.4)
30-VDC induc
tive (L/R = 7 ms)
G6C-1114P-US
250-VAC induc
tive (cosφ = 0.4)
30-VDC inductive
(L/R = 7 ms)
Switching current (A)
Ambient Temperature vs.
Maximum Coil Voltage
Maximum coil voltage (%)
■
Power Relays
Omron 08 Cat 1-302
Note: The maximum coil voltage refers to the maximum value in a varying range of operating
power voltage, not a continuous voltage.
Ambient temperature (°C)
110
111
5/10/07
15:39
Page 110
Text Power Relay – G6C
PCB
Text Power Relay – G6C
PCB
Characteristics
Approved Standards (continued)
CSA C22.2 No.14 (File No. LR31928)
■
Contact resistance
30 mΩ max.
Operate (set) time
10 ms max. (mean value: approx. 5 ms)
Release (reset) time
10 ms max. (mean value: approx. 2 ms; latching types: mean value: approx. 5 ms)
Bounce Time
Operate: 5 ms max.
Release: 5 ms max.
Min. set/reset signal width
Latching type: 20 ms (at 23˚C)
Max. switching frequency
Mechanical: 18,000 operations/hr
Electrical: 1,800 operations/hr (under rated load)
Insulation resistance
1,000 MΩ min. (at 500 VDC, at 250 VDC between set coil and reset coil)
Dielectric strength
2,000 VAC, 50/60 Hz for 1 min between coil and contacts
2,000 VAC, 50/60 Hz for 1 min between contacts of different polarity
1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity
250 VAC, 50/60 Hz for 1 min between set and reset coils
Insulation
Distance
Model
Contact form
Coil rating
Contact rating
G6C-1114P-US
G6C-1114C-US
G6C-1117P-US
G6C-1117C-US
SPST-NO
3 to 60 VDC
10 A, 250 VAC (general use)
10 A, 30 VDC (resistive load)
1/6 hp, 125 VAC
1/4 hp, 125 VAC
1/4 hp, 250 VAC
1/3 hp, 250 VAC
TV-5
600 W, 120 VAC (tungsten)
G6C-2114P-US
G6C-2114C-US
G6C-2117P-US
G6C-2117C-US
SPST-NO + SPST-NC
3 to 60 VDC
8 A, 250 VAC (general use)
8 A, 30 VDC (resistive load)
1/6 hp, 125 VAC
1/4 hp, 125 VAC
1/4 hp, 250 VAC
TV-5
600 W, 120 VAC (tungsten)
Creepage (Typ) 5.5 mm
Clearance (Typ) 5.5 mm
VDE (Approval No. 2413) EN61810-1
175 V
Impulse withstand voltage
6.000 V (1.2 x 50 µs) between coil and contacts (latching types: 4,500 V, 1.2 50 µs)
Vibration resistance
Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Malfunction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Shock resistance
Destruction: 1,000 m/s2
Malfunction: 100 m/s2
Ambient temperature
Operating: -25˚C to 70˚C (with no icing)
Ambient humidity
Operating: 5% to 85%
Endurance
Mechanical: 50,000,000 operations min. (at 18,000 operations/hr)
Electrical: 100,000 operations min. (at 1,800 operations/hr)
Weight
Approx. 5.6 g
Approved Standards
UL508 (File No. E41643)
G6C-2114P-US
G6C-2114C–US
G6C-2117P-US
G6C-2117C-US
SPST-NO + SPST-NC
Contact rating
Number of test
operations
G6C-1114P-US
G6C-1114C-US
G6C-1117P-US
G6C-1117C-US
SPST-NO
3, 12, 24VDC
10A, 250VAC (cosφ = 1)
5A, 250VAC (cosφ = 0.4)
100,000
G6C-2114P-US
G6C-2114C-US
G6C-2117P-US
G6C-2117C-US
SPST-NO+SPST-NC Single-stable: 3, 5,
12, 24VDC
Latching: 5VDC
G6CU-2117P-VD: 3VDC
7A, 250VAC (cosφ = 1)
3.5A, 250VAC (cosφ = 0.4)
100,000
Engineering Data
Maximum Switching Power
SPST-NO
Coil rating
3 to 60 VDC
Contact rating
10 A, 250 VAC (general use)
10 A, 30 VDC (resistive load)
1/6 hp, 125 VAC
1/4 hp, 125 VAC
1/4 hp, 250 VAC
1/3 hp, 250 VAC
TV-5
600 W, 120 VAC (tungsten)
530 VA, 20 to 265 VAC, 2 A max. (pilot duty)
43.2 VA, 30 VDC (pilot duty)
12LRA, 2.2FLA, 30 VDC (30,000 cycle)
8 A, 250 VAC (general use)
8 A, 30 VDC (resistive load)
1/6 hp, 125 VAC
1/4 hp, 125 VAC
1/4 hp, 250 VAC
TV-5
600 W, 120 VAC (tungsten)
Endurance
SPST-NO + SPST-NC
AC inductive load
(cosφ = 0.4)
AC resistive
load
DC inductive load
(L/R = 7 ms)
DC resistive
load
Switching voltage (V)
Switching current (A)
SPST-NO
Coil rating
Switching current (A)
G6C-1114P-US
G6C-1114C-US
G6C-1117P-US
G6C-1117C-US
Contact form
Contact form
■
■
Model
Model
AC inductive load
(cosφ = 0.4)
AC resistive load
DC inductive load
(L/R = 7 ms)
DC resistive
load
Endurance (x10 3 operations)
Tracking Resistance (CTI)
Switching voltage (V)
G6C-2114P-US
250-VAC resistive
30-VDC resistive
G6C-1114P-US
250-VAC resistive
30-VDC resistive
G6C-2114P-US
250-VAC induc
tive (cosφ = 0.4)
30-VDC induc
tive (L/R = 7 ms)
G6C-1114P-US
250-VAC induc
tive (cosφ = 0.4)
30-VDC inductive
(L/R = 7 ms)
Switching current (A)
Ambient Temperature vs.
Maximum Coil Voltage
Maximum coil voltage (%)
■
Power Relays
Omron 08 Cat 1-302
Note: The maximum coil voltage refers to the maximum value in a varying range of operating
power voltage, not a continuous voltage.
Ambient temperature (°C)
110
111
Omron 08 Cat 1-302
5/10/07
15:39
Page 112
Text Power Relay – G6C
PCB
Text Power Relay – G6C
PCB
Power Relays
Dimensions
Note: 1. All units are in millimetres unless otherwise indicated.
2. Orientation marks are indicated as follows:
112
113
Omron 08 Cat 1-302
5/10/07
15:39
Page 112
Text Power Relay – G6C
PCB
Text Power Relay – G6C
PCB
Power Relays
Dimensions
Note: 1. All units are in millimetres unless otherwise indicated.
2. Orientation marks are indicated as follows:
112
113
Omron 08 Cat 1-302
5/10/07
15:39
Text Power Relay – G6C
PCB
Page 114
Text Power Relay – G6C
PCB
Back Connecting Sockets
P6C-06P
(2.61) 10.16
15 max.
(14.9)*
3.1
7.62
Power Relays
Mounting Holes (Bottom View)
23.2 max.
(23)*
Six, 1.1-dia holes
(2.4)
10.16
10.8 max.
(10.6)*
7.5
(2.61)
Mounting Height of Relay
with Connecting Socket
3.5
0.8
10.16
0.4
7.62
17 mm max.
10.16
*Average value
P6C-08P
7.5 mm max.
23.2 max.
(23)*
15 max.
(14.9)*
Mounting Holes (Bottom View)
(2.61) 2.54 7.62 7.62 Eight, 1.1-dia holes
3.1
(2.4)
10.16
10.8 max.
(10.6)*
7.5
(2.61)
3.5
0.4
0.8
2.54
7.62
7.62
10.16
*Average value
Removal Tool
Hold-down Clips
P6B-Y1
P6B-C2
Note: Rated current of socket max. 5 A
CAT. No. K018-E2-05A-X
114
115
Omron 08 Cat 1-302
5/10/07
15:39
Text Power Relay – G6C
PCB
Page 114
Text Power Relay – G6C
PCB
Back Connecting Sockets
P6C-06P
(2.61) 10.16
15 max.
(14.9)*
3.1
7.62
Power Relays
Mounting Holes (Bottom View)
23.2 max.
(23)*
Six, 1.1-dia holes
(2.4)
10.16
10.8 max.
(10.6)*
7.5
(2.61)
Mounting Height of Relay
with Connecting Socket
3.5
0.8
10.16
0.4
7.62
17 mm max.
10.16
*Average value
P6C-08P
7.5 mm max.
23.2 max.
(23)*
15 max.
(14.9)*
Mounting Holes (Bottom View)
(2.61) 2.54 7.62 7.62 Eight, 1.1-dia holes
3.1
(2.4)
10.16
10.8 max.
(10.6)*
7.5
(2.61)
3.5
0.4
0.8
2.54
7.62
7.62
10.16
*Average value
Removal Tool
Hold-down Clips
P6B-Y1
P6B-C2
Note: Rated current of socket max. 5 A
CAT. No. K018-E2-05A-X
114
115