5/10/07 15:39 Page 106 Text Power Relay – G6C PCB Text Power Relay – G5CA PCB Precautions ■ Precautions for Correct Use Installation Make sure that sufficient space is provided between relays when installing two or more relays side by side to facilitate heat dissipation. Insufficient heat dissipation may result in the relay malfunctioning. Charged Terminals The section marked with dotted circles (indicated by arrows) in the following diagram includes the charged terminals of the relay. When the relay is mounted on a PCB, make sure that there are no metal patterns on the section of the PCB facing the portion of the relay shaded in the following diagram. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load Power Relays Omron 08 Cat 1-302 ■ ROHS compliant ■ Compact: 20 x 15 x 10 mm (L x W x H). ■ Low power consumption: 200 mW. ■ Flux protection or fully sealed construction available. ■ Unique moving loop armature reduces relay size, magnetic interference, and contact bounce. ■ Single- and double-winding latching types Quick-connect Terminal Connections • Do not pass current through the PCB of the load contactterminals (quick-connect terminals). • The terminals are compatible with Faston receptacle #187 and are suitable for positive-lock mounting. Use only Faston terminals with the specified numbers. Select leads for connecting Faston receptacles with wire diameters that are within the allowable range for the load current. Do not apply excessive force to the terminals when mounting or dismounting the Faston receptacle. Insert and remove terminals carefully one at a time. Do not insert terminals on an angle, or insert/remove multiple terminals at the same time. The following positive-lock connectors made by AMP are recommended. Contact the manufacturer directly for details on connectors including availability. Type also available Other Precautions • The G5CA is a power relay designed for applications switching power loads such as heaters in electric household appliances. Do not use the G5CA to switch micro loads less than 100 mA, such as in signal applications. • Use fully sealed models if the relays will require washing. Fluxprotection models may malfunction or the relay's performance may be otherwise adversely affected if cleaning fluid enters the relay. Type Receptacle terminals (See note.) #187 terminals (width: 4.75 mm) AMP 170330-1 (170324-1) AMP 170331-1 (170325-1) AMP 170332-1 (170326-1) Positive housing AMP AMP AMP AMP 172074-1 172074-4 172074-5 172074-6 (natural color) (yellow) (green) (blue) Ordering Information Classification Contact form Single-side stable Straight PCB SPST-NO Self-clinching PCB Flux protection Fully sealed Flux protection G6C-1117P-US G6C-1114P-US G6C-1117C-US Fully sealed G6C-1114C-US SPST-NO + SPST-NC G6C-2117P-US G6C-2114P-US G6C-2117C-US G6C-2114C-US Single-winding latching SPST-NO G6CU-1114P-US G6CU-1117C-US G6CU-1114C-US SPST-NO + SPST-NC G6CU-2117P-US G6CU-2114P-US G6CU-2117C-US G6CU-2114C-US Double-winding latching SPST-NO G6CK-1117P-US G6CK-1114P-US G6CK-1117C-US G6CK-1114C-US SPST-NO + SPST-NC G6CK-2117P-US G6CK-2114P-US G6CK-2117C-US G6CK-2114C-US G6CU-1117P-US Note: When ordering, add the rated coil voltage to the model number. Example: G6C-1117P-US 12 VDC Rated coil voltage Model Number Legend Note: The numbers shown in parentheses are for air-feeding G6C 1 2 3 4 5 VDC 6 1. Relay Function None: Single-side stable U: Single-winding latching K: Double-winding latching 2. Contact Form 11: SPST-NO 21: SPST-NO + SPST-NC 7 3. Contact Type 1: Standard 4. Enclosure Ratings 7: Flux protection 4: Fully sealed 5. Terminals P: Straight PCB C: Self-clinching PCB 6. Approved Standards US: UL/CSA certified 7. Rated Coil Voltage 3, 5, 6, 12, 24 VDC ALL DIMENSIONS SHOWN ARE IN MILLIMETRES. To convert millimetres into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. CAT. No. J151-E2-02A-X 106 107 5/10/07 15:39 Page 108 Text Power Relay – G6C PCB Text Power Relay – G6C PCB ■ Accessories (Order Separately) Double-winding Latching Type Back Connecting Sockets Applicable relay G6C(U)-1114P-US G6C(U)-1117P-US G6C(U)-2114P-US G6C(U)-2117P-US G6CK-1114P-US G6CK-1117P-US G6CK-2114P-US G6CK-2117P-US Back connecting socket* P6C-06P Removal Tool P6B-Y1 Hold-down Clips P6B-C2 3 VDC 5 VDC 6 VDC 12 VDC Set coil Rated current 93.5 mA 56.0 mA 46.7 mA 23.3 mA 11.7 mA Coil resistance 32.1 Ω 89.3 Ω 129 Ω 514 Ω 2,056 Ω Reset coil P6C-08P *Not applicable to the self-clinching type. The operating current for the socket is 5 A max Specifications ■ Rated voltage Coil Rating 24 VDC Coil inductance Armature OFF 0.03 0.07 0.10 0.37 1.56 (H) (ref. value) Armature OFF 0.02 0.06 0.08 0.32 1.18 Rated current 93.5 mA 56.0 mA 46.7 mA 23.3 mA 11.7 mA Coil resistance 32.1 Ω 89.3 Ω 129 Ω 514 Ω 2,056 Ω Coil inductance Armature OFF 0.03 0.08 0.12 0.47 1.46 (H) (ref. value) Armature OFF 0.02 0.07 0.10 0.38 1.13 Must set voltage 70% max. of rated voltage Must reset voltage 70% min. of rated voltage Max. voltage 130% of rated voltage (at 23°C) Power consumption Set coil: Approx. 280 mW Reset coil: Approx. 280 mW Power Relays Omron 08 Cat 1-302 Single-side Stable Type Rated voltage 3 VDC 5 VDC 6 VDC 12 VDC 24 VDC Rated current 67 mA 40 mA 33.3 mA 16.7 mA 8.3 mA Coil resistance 45 Ω 125 Ω 180 Ω 720 Ω 2,880 Ω Coil inductance Armature OFF 0.078 0.22 0.36 1.32 4.96 Armature OFF 0.067 0.18 0.29 1.13 4.19 (H) (ref. value) Must operate voltage 70% max. of rated voltage Must release voltage 10% min. of rated voltage Max. voltage 160% of rated voltage (at 23°C) Power consumption Approx. 200 mW Single-side Latching Type Rated voltage 3 VDC 5 VDC 6 VDC 12 VDC 24 VDC Rated current 67 mA 40 mA 33.3 mA 16.7 mA 8.3 mA Coil resistance 45 Ω 125 Ω 180 Ω 720 Ω 2,880 Ω Coil inductance Armature OFF 0.09 0.25 0.36 1.75 5.83 Armature OFF 0.06 0.20 0.24 1.17 3.84 (H) (ref. value) Must operate voltage 70% max. of rated voltage Must release voltage 70% min. of rated voltage Max. voltage 160% of rated voltage (at 23°C) Power consumption Approx. 200 mW 108 Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%. 2. Operating characteristics are measured at a coil temperature of 23°C. 3. The minimum pulse width of the set and reset voltage is 20 ms. ■ Contact Ratings Item SPST-NO SPST-NO+SPST-NC Load Resistive load (cosφ = 1) Inductive load Resistive load (cosφ = 0.4; L/R = 7 ms) (cosφ = 1) Inductive load cosφ = 0.4; L/R = 7 ms) Rated load 10 A at 250 VAC; 10A at 30 VDC 5 A at 250 VAC; 5 A at 30 VDC 3.5 A at 250 VAC; 3.5 A at 30 VDC Contact material AgNi (FD type = AgSnIn) Rated carry current 10 A Max. switching voltage 380 VAC, 125 VDC (the case of latching 250 VAC, 125 VDC) Max. switching current 10 A Max. switching power 2,500 VA, 300 W Failure rate (reference value) 10 mA at 5 VDC 8A at 250 VAC; 8A at 30 VDC; 8A 8A 1,250 VA, 220 W 2,000 VA, 240 W 875 VA, 170 W Note: P level: λ60 = 0.1 x 10-6/operation 109 5/10/07 15:39 Page 108 Text Power Relay – G6C PCB Text Power Relay – G6C PCB ■ Accessories (Order Separately) Double-winding Latching Type Back Connecting Sockets Applicable relay G6C(U)-1114P-US G6C(U)-1117P-US G6C(U)-2114P-US G6C(U)-2117P-US G6CK-1114P-US G6CK-1117P-US G6CK-2114P-US G6CK-2117P-US Back connecting socket* P6C-06P Removal Tool P6B-Y1 Hold-down Clips P6B-C2 3 VDC 5 VDC 6 VDC 12 VDC Set coil Rated current 93.5 mA 56.0 mA 46.7 mA 23.3 mA 11.7 mA Coil resistance 32.1 Ω 89.3 Ω 129 Ω 514 Ω 2,056 Ω Reset coil P6C-08P *Not applicable to the self-clinching type. The operating current for the socket is 5 A max Specifications ■ Rated voltage Coil Rating 24 VDC Coil inductance Armature OFF 0.03 0.07 0.10 0.37 1.56 (H) (ref. value) Armature OFF 0.02 0.06 0.08 0.32 1.18 Rated current 93.5 mA 56.0 mA 46.7 mA 23.3 mA 11.7 mA Coil resistance 32.1 Ω 89.3 Ω 129 Ω 514 Ω 2,056 Ω Coil inductance Armature OFF 0.03 0.08 0.12 0.47 1.46 (H) (ref. value) Armature OFF 0.02 0.07 0.10 0.38 1.13 Must set voltage 70% max. of rated voltage Must reset voltage 70% min. of rated voltage Max. voltage 130% of rated voltage (at 23°C) Power consumption Set coil: Approx. 280 mW Reset coil: Approx. 280 mW Power Relays Omron 08 Cat 1-302 Single-side Stable Type Rated voltage 3 VDC 5 VDC 6 VDC 12 VDC 24 VDC Rated current 67 mA 40 mA 33.3 mA 16.7 mA 8.3 mA Coil resistance 45 Ω 125 Ω 180 Ω 720 Ω 2,880 Ω Coil inductance Armature OFF 0.078 0.22 0.36 1.32 4.96 Armature OFF 0.067 0.18 0.29 1.13 4.19 (H) (ref. value) Must operate voltage 70% max. of rated voltage Must release voltage 10% min. of rated voltage Max. voltage 160% of rated voltage (at 23°C) Power consumption Approx. 200 mW Single-side Latching Type Rated voltage 3 VDC 5 VDC 6 VDC 12 VDC 24 VDC Rated current 67 mA 40 mA 33.3 mA 16.7 mA 8.3 mA Coil resistance 45 Ω 125 Ω 180 Ω 720 Ω 2,880 Ω Coil inductance Armature OFF 0.09 0.25 0.36 1.75 5.83 Armature OFF 0.06 0.20 0.24 1.17 3.84 (H) (ref. value) Must operate voltage 70% max. of rated voltage Must release voltage 70% min. of rated voltage Max. voltage 160% of rated voltage (at 23°C) Power consumption Approx. 200 mW 108 Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%. 2. Operating characteristics are measured at a coil temperature of 23°C. 3. The minimum pulse width of the set and reset voltage is 20 ms. ■ Contact Ratings Item SPST-NO SPST-NO+SPST-NC Load Resistive load (cosφ = 1) Inductive load Resistive load (cosφ = 0.4; L/R = 7 ms) (cosφ = 1) Inductive load cosφ = 0.4; L/R = 7 ms) Rated load 10 A at 250 VAC; 10A at 30 VDC 5 A at 250 VAC; 5 A at 30 VDC 3.5 A at 250 VAC; 3.5 A at 30 VDC Contact material AgNi (FD type = AgSnIn) Rated carry current 10 A Max. switching voltage 380 VAC, 125 VDC (the case of latching 250 VAC, 125 VDC) Max. switching current 10 A Max. switching power 2,500 VA, 300 W Failure rate (reference value) 10 mA at 5 VDC 8A at 250 VAC; 8A at 30 VDC; 8A 8A 1,250 VA, 220 W 2,000 VA, 240 W 875 VA, 170 W Note: P level: λ60 = 0.1 x 10-6/operation 109 5/10/07 15:39 Page 110 Text Power Relay – G6C PCB Text Power Relay – G6C PCB Characteristics Approved Standards (continued) CSA C22.2 No.14 (File No. LR31928) ■ Contact resistance 30 mΩ max. Operate (set) time 10 ms max. (mean value: approx. 5 ms) Release (reset) time 10 ms max. (mean value: approx. 2 ms; latching types: mean value: approx. 5 ms) Bounce Time Operate: 5 ms max. Release: 5 ms max. Min. set/reset signal width Latching type: 20 ms (at 23˚C) Max. switching frequency Mechanical: 18,000 operations/hr Electrical: 1,800 operations/hr (under rated load) Insulation resistance 1,000 MΩ min. (at 500 VDC, at 250 VDC between set coil and reset coil) Dielectric strength 2,000 VAC, 50/60 Hz for 1 min between coil and contacts 2,000 VAC, 50/60 Hz for 1 min between contacts of different polarity 1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity 250 VAC, 50/60 Hz for 1 min between set and reset coils Insulation Distance Model Contact form Coil rating Contact rating G6C-1114P-US G6C-1114C-US G6C-1117P-US G6C-1117C-US SPST-NO 3 to 60 VDC 10 A, 250 VAC (general use) 10 A, 30 VDC (resistive load) 1/6 hp, 125 VAC 1/4 hp, 125 VAC 1/4 hp, 250 VAC 1/3 hp, 250 VAC TV-5 600 W, 120 VAC (tungsten) G6C-2114P-US G6C-2114C-US G6C-2117P-US G6C-2117C-US SPST-NO + SPST-NC 3 to 60 VDC 8 A, 250 VAC (general use) 8 A, 30 VDC (resistive load) 1/6 hp, 125 VAC 1/4 hp, 125 VAC 1/4 hp, 250 VAC TV-5 600 W, 120 VAC (tungsten) Creepage (Typ) 5.5 mm Clearance (Typ) 5.5 mm VDE (Approval No. 2413) EN61810-1 175 V Impulse withstand voltage 6.000 V (1.2 x 50 µs) between coil and contacts (latching types: 4,500 V, 1.2 50 µs) Vibration resistance Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) Malfunction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) Shock resistance Destruction: 1,000 m/s2 Malfunction: 100 m/s2 Ambient temperature Operating: -25˚C to 70˚C (with no icing) Ambient humidity Operating: 5% to 85% Endurance Mechanical: 50,000,000 operations min. (at 18,000 operations/hr) Electrical: 100,000 operations min. (at 1,800 operations/hr) Weight Approx. 5.6 g Approved Standards UL508 (File No. E41643) G6C-2114P-US G6C-2114C–US G6C-2117P-US G6C-2117C-US SPST-NO + SPST-NC Contact rating Number of test operations G6C-1114P-US G6C-1114C-US G6C-1117P-US G6C-1117C-US SPST-NO 3, 12, 24VDC 10A, 250VAC (cosφ = 1) 5A, 250VAC (cosφ = 0.4) 100,000 G6C-2114P-US G6C-2114C-US G6C-2117P-US G6C-2117C-US SPST-NO+SPST-NC Single-stable: 3, 5, 12, 24VDC Latching: 5VDC G6CU-2117P-VD: 3VDC 7A, 250VAC (cosφ = 1) 3.5A, 250VAC (cosφ = 0.4) 100,000 Engineering Data Maximum Switching Power SPST-NO Coil rating 3 to 60 VDC Contact rating 10 A, 250 VAC (general use) 10 A, 30 VDC (resistive load) 1/6 hp, 125 VAC 1/4 hp, 125 VAC 1/4 hp, 250 VAC 1/3 hp, 250 VAC TV-5 600 W, 120 VAC (tungsten) 530 VA, 20 to 265 VAC, 2 A max. (pilot duty) 43.2 VA, 30 VDC (pilot duty) 12LRA, 2.2FLA, 30 VDC (30,000 cycle) 8 A, 250 VAC (general use) 8 A, 30 VDC (resistive load) 1/6 hp, 125 VAC 1/4 hp, 125 VAC 1/4 hp, 250 VAC TV-5 600 W, 120 VAC (tungsten) Endurance SPST-NO + SPST-NC AC inductive load (cosφ = 0.4) AC resistive load DC inductive load (L/R = 7 ms) DC resistive load Switching voltage (V) Switching current (A) SPST-NO Coil rating Switching current (A) G6C-1114P-US G6C-1114C-US G6C-1117P-US G6C-1117C-US Contact form Contact form ■ ■ Model Model AC inductive load (cosφ = 0.4) AC resistive load DC inductive load (L/R = 7 ms) DC resistive load Endurance (x10 3 operations) Tracking Resistance (CTI) Switching voltage (V) G6C-2114P-US 250-VAC resistive 30-VDC resistive G6C-1114P-US 250-VAC resistive 30-VDC resistive G6C-2114P-US 250-VAC induc tive (cosφ = 0.4) 30-VDC induc tive (L/R = 7 ms) G6C-1114P-US 250-VAC induc tive (cosφ = 0.4) 30-VDC inductive (L/R = 7 ms) Switching current (A) Ambient Temperature vs. Maximum Coil Voltage Maximum coil voltage (%) ■ Power Relays Omron 08 Cat 1-302 Note: The maximum coil voltage refers to the maximum value in a varying range of operating power voltage, not a continuous voltage. Ambient temperature (°C) 110 111 5/10/07 15:39 Page 110 Text Power Relay – G6C PCB Text Power Relay – G6C PCB Characteristics Approved Standards (continued) CSA C22.2 No.14 (File No. LR31928) ■ Contact resistance 30 mΩ max. Operate (set) time 10 ms max. (mean value: approx. 5 ms) Release (reset) time 10 ms max. (mean value: approx. 2 ms; latching types: mean value: approx. 5 ms) Bounce Time Operate: 5 ms max. Release: 5 ms max. Min. set/reset signal width Latching type: 20 ms (at 23˚C) Max. switching frequency Mechanical: 18,000 operations/hr Electrical: 1,800 operations/hr (under rated load) Insulation resistance 1,000 MΩ min. (at 500 VDC, at 250 VDC between set coil and reset coil) Dielectric strength 2,000 VAC, 50/60 Hz for 1 min between coil and contacts 2,000 VAC, 50/60 Hz for 1 min between contacts of different polarity 1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity 250 VAC, 50/60 Hz for 1 min between set and reset coils Insulation Distance Model Contact form Coil rating Contact rating G6C-1114P-US G6C-1114C-US G6C-1117P-US G6C-1117C-US SPST-NO 3 to 60 VDC 10 A, 250 VAC (general use) 10 A, 30 VDC (resistive load) 1/6 hp, 125 VAC 1/4 hp, 125 VAC 1/4 hp, 250 VAC 1/3 hp, 250 VAC TV-5 600 W, 120 VAC (tungsten) G6C-2114P-US G6C-2114C-US G6C-2117P-US G6C-2117C-US SPST-NO + SPST-NC 3 to 60 VDC 8 A, 250 VAC (general use) 8 A, 30 VDC (resistive load) 1/6 hp, 125 VAC 1/4 hp, 125 VAC 1/4 hp, 250 VAC TV-5 600 W, 120 VAC (tungsten) Creepage (Typ) 5.5 mm Clearance (Typ) 5.5 mm VDE (Approval No. 2413) EN61810-1 175 V Impulse withstand voltage 6.000 V (1.2 x 50 µs) between coil and contacts (latching types: 4,500 V, 1.2 50 µs) Vibration resistance Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) Malfunction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) Shock resistance Destruction: 1,000 m/s2 Malfunction: 100 m/s2 Ambient temperature Operating: -25˚C to 70˚C (with no icing) Ambient humidity Operating: 5% to 85% Endurance Mechanical: 50,000,000 operations min. (at 18,000 operations/hr) Electrical: 100,000 operations min. (at 1,800 operations/hr) Weight Approx. 5.6 g Approved Standards UL508 (File No. E41643) G6C-2114P-US G6C-2114C–US G6C-2117P-US G6C-2117C-US SPST-NO + SPST-NC Contact rating Number of test operations G6C-1114P-US G6C-1114C-US G6C-1117P-US G6C-1117C-US SPST-NO 3, 12, 24VDC 10A, 250VAC (cosφ = 1) 5A, 250VAC (cosφ = 0.4) 100,000 G6C-2114P-US G6C-2114C-US G6C-2117P-US G6C-2117C-US SPST-NO+SPST-NC Single-stable: 3, 5, 12, 24VDC Latching: 5VDC G6CU-2117P-VD: 3VDC 7A, 250VAC (cosφ = 1) 3.5A, 250VAC (cosφ = 0.4) 100,000 Engineering Data Maximum Switching Power SPST-NO Coil rating 3 to 60 VDC Contact rating 10 A, 250 VAC (general use) 10 A, 30 VDC (resistive load) 1/6 hp, 125 VAC 1/4 hp, 125 VAC 1/4 hp, 250 VAC 1/3 hp, 250 VAC TV-5 600 W, 120 VAC (tungsten) 530 VA, 20 to 265 VAC, 2 A max. (pilot duty) 43.2 VA, 30 VDC (pilot duty) 12LRA, 2.2FLA, 30 VDC (30,000 cycle) 8 A, 250 VAC (general use) 8 A, 30 VDC (resistive load) 1/6 hp, 125 VAC 1/4 hp, 125 VAC 1/4 hp, 250 VAC TV-5 600 W, 120 VAC (tungsten) Endurance SPST-NO + SPST-NC AC inductive load (cosφ = 0.4) AC resistive load DC inductive load (L/R = 7 ms) DC resistive load Switching voltage (V) Switching current (A) SPST-NO Coil rating Switching current (A) G6C-1114P-US G6C-1114C-US G6C-1117P-US G6C-1117C-US Contact form Contact form ■ ■ Model Model AC inductive load (cosφ = 0.4) AC resistive load DC inductive load (L/R = 7 ms) DC resistive load Endurance (x10 3 operations) Tracking Resistance (CTI) Switching voltage (V) G6C-2114P-US 250-VAC resistive 30-VDC resistive G6C-1114P-US 250-VAC resistive 30-VDC resistive G6C-2114P-US 250-VAC induc tive (cosφ = 0.4) 30-VDC induc tive (L/R = 7 ms) G6C-1114P-US 250-VAC induc tive (cosφ = 0.4) 30-VDC inductive (L/R = 7 ms) Switching current (A) Ambient Temperature vs. Maximum Coil Voltage Maximum coil voltage (%) ■ Power Relays Omron 08 Cat 1-302 Note: The maximum coil voltage refers to the maximum value in a varying range of operating power voltage, not a continuous voltage. Ambient temperature (°C) 110 111 Omron 08 Cat 1-302 5/10/07 15:39 Page 112 Text Power Relay – G6C PCB Text Power Relay – G6C PCB Power Relays Dimensions Note: 1. All units are in millimetres unless otherwise indicated. 2. Orientation marks are indicated as follows: 112 113 Omron 08 Cat 1-302 5/10/07 15:39 Page 112 Text Power Relay – G6C PCB Text Power Relay – G6C PCB Power Relays Dimensions Note: 1. All units are in millimetres unless otherwise indicated. 2. Orientation marks are indicated as follows: 112 113 Omron 08 Cat 1-302 5/10/07 15:39 Text Power Relay – G6C PCB Page 114 Text Power Relay – G6C PCB Back Connecting Sockets P6C-06P (2.61) 10.16 15 max. (14.9)* 3.1 7.62 Power Relays Mounting Holes (Bottom View) 23.2 max. (23)* Six, 1.1-dia holes (2.4) 10.16 10.8 max. (10.6)* 7.5 (2.61) Mounting Height of Relay with Connecting Socket 3.5 0.8 10.16 0.4 7.62 17 mm max. 10.16 *Average value P6C-08P 7.5 mm max. 23.2 max. (23)* 15 max. (14.9)* Mounting Holes (Bottom View) (2.61) 2.54 7.62 7.62 Eight, 1.1-dia holes 3.1 (2.4) 10.16 10.8 max. (10.6)* 7.5 (2.61) 3.5 0.4 0.8 2.54 7.62 7.62 10.16 *Average value Removal Tool Hold-down Clips P6B-Y1 P6B-C2 Note: Rated current of socket max. 5 A CAT. No. K018-E2-05A-X 114 115 Omron 08 Cat 1-302 5/10/07 15:39 Text Power Relay – G6C PCB Page 114 Text Power Relay – G6C PCB Back Connecting Sockets P6C-06P (2.61) 10.16 15 max. (14.9)* 3.1 7.62 Power Relays Mounting Holes (Bottom View) 23.2 max. (23)* Six, 1.1-dia holes (2.4) 10.16 10.8 max. (10.6)* 7.5 (2.61) Mounting Height of Relay with Connecting Socket 3.5 0.8 10.16 0.4 7.62 17 mm max. 10.16 *Average value P6C-08P 7.5 mm max. 23.2 max. (23)* 15 max. (14.9)* Mounting Holes (Bottom View) (2.61) 2.54 7.62 7.62 Eight, 1.1-dia holes 3.1 (2.4) 10.16 10.8 max. (10.6)* 7.5 (2.61) 3.5 0.4 0.8 2.54 7.62 7.62 10.16 *Average value Removal Tool Hold-down Clips P6B-Y1 P6B-C2 Note: Rated current of socket max. 5 A CAT. No. K018-E2-05A-X 114 115