Datasheet

G3M
Solid State Relays
5A Load Switching provided for
the whole G3M product line
• Thin design for high-density PCB applications.
• DC input-AC output for a 3-A load or a 5-A load.
• The 5A type is UL, CSA, EN (EN60950) approved.
• UL and CSA compliance for 3-A Relays
(-UTU models have TÜV compliance as well).
• UL and CSA compliance for 5-A Relays
(-VD models have VDE compliance as well).
RoHS Compliant
Refer to "Solid State Relays Common Precautions".
■Model Number Legend
G 3 M -@ @ @@ @ -@ -@
———— — —
1
2
3 4
5
6
1. Rated Load Power Supply Voltage
2: Maximum operating voltage
lower than 264 V
4. Zero Cross Function
Blank: Equipped with zero cross function
L : Not equipped with zero cross function
2. Rated Load Current
03: 3 A
05: 5 A
5. Certification
Blank: UL and CSA for 3-A models
No certification for 5-A models
UTU : UL, CSA and TÜV for 3-A models
VD : UL, CSA and TÜV for 5-A models
UTU-1 : UL, CSA and TÜV for 3-A models
with reinforced insulation
VD-1 : UL, CSA and TÜV for 5-A models
with reinforced insulation
3. Terminal Type
P: PCB terminals
6. Input Terminal Pitch
Blank: 7.62 mm
4 : 5.08 mm
G
3
M
■List of Models
Isolation
Input terminal pitch
Zero cross
function
Indicator
Rated output load
Rated input
voltage
5 VDC
G3M-203P
5 VDC
3 A at 100 to 240 VAC
12 VDC
G3M-203P
12 VDC
24 VDC
G3M-203P
24 VDC
5 VDC
G3M-205P
5 VDC
12 VDC
G3M-205P
12 VDC
24 VDC
G3M-205P
24 VDC
5 VDC
G3M-203PL
5 VDC
12 VDC
G3M-203PL
12 VDC
24 VDC
G3M-203PL
24 VDC
5 VDC
G3M-205PL
5 VDC
12 VDC
G3M-205PL
12 VDC
24 VDC
G3M-205PL
24 VDC
5 VDC
G3M-203P-4
5 VDC
12 VDC
G3M-203P-4
12 VDC
24 VDC
G3M-203P-4
24 VDC
5 VDC
G3M-205P-4
5 VDC
12 VDC
G3M-205P-4
12 VDC
24 VDC
G3M-205P-4
24 VDC
5 VDC
G3M-203PL-4
5 VDC
12 VDC
G3M-203PL-4
12 VDC
24 VDC
G3M-203PL-4
24 VDC
5 VDC
G3M-205PL-4
5 VDC
12 VDC
G3M-205PL-4
12 VDC
24 VDC
G3M-205PL-4
24 VDC
Yes
5 A at 100 to 240 VAC
7.62 mm
3 A at 100 to 240 VAC
No
5 A at 100 to 240 VAC
Phototriac
No
3 A at 100 to 240 VAC
Yes
5 A at 100 to 240 VAC
5.08 mm
3 A at 100 to 240 VAC
No
5 A at 100 to 240 VAC
Minimum packing
unit
Model
100 pcs
1
G3M
Solid State Relays
■Ratings
Input (Each model has 5-VDC, 12-VDC, and 24-VDC input versions.)
Rated
voltage
Operating voltage
5 VDC
4 to 6 VDC
Impedance
Must operate
voltage level
300 Ω ±20%
4 VDC max.
12 VDC 9.6 to 14.4 VDC
800 Ω ±20%
9.6 VDC max.
24 VDC 19.2 to 28.8 VDC
1.6 kΩ ±20% 19.2 VDC max.
Output
Must release
voltage level
Item
Model
G3M-203P(L)
1 VDC min.
G3M-205P(L)
*
Rated
voltage
100 to
240 VAC
Model
Operate time
Release time
G3M-203P(L)
1/2 of load power source cycle + 1 ms max.
1.6 V (RMS) max.
Leakage current
Insulation resistance
Dielectric strength
Vibration resistance
1.5 mA max. (at 200 VAC)
1,000 MΩ min. (at 500 VDC)
2,500 VAC, 50/60 Hz for 1 min between input and output
10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
1,000 m/s2
Shock resistance
Ambient operating temperature
−30°C to 80°C (with no icing or condensation)
Ambient operating humidity
Storage temperature
G
3
M
Weight
2
G3M-205P(L)
G3M-@@@PL: 1 ms max.
G3M-@@@P: 1/2 of load power source cycle + 1 ms max.
Output ON voltage drop
45% to 85%RH
−30°C to 100°C (with no icing or condensation)
Approx. 15 g
Load voltage range Load current
Inrush current
0.1 to 3 A *
45 A
(60 Hz, 1 cycle)
0.1 to 5 A *
60 A
(60Hz, 1 cycle)
75 to 264 VAC
The load current varies depending on the ambient temperature.
Refer to Load Current vs. Ambient Temperature under Engineering Data.
■Characteristics
Item
Applicable load
Approx. 25 g
G3M
Solid State Relays
Load current (A)
Load Current vs. Ambient
Temperature
6
G3M-205P(L)
5
4
G3M-203P(L)
One Cycle Surge Current:
Non-repetitive
Non-repetitive (Reduce the current under the
dotted line of the impulse withstand current for
repetitive operation)
Inrush peak current (A)
■Engineering Data
70
60
50
G3M-205P(L)
40
G3M-203P(L)
3
30
2
20
1
10
0.5
0
-30
-20
0
20 25
40
60
80
100
Ambient temperature (°C)
10
30 50 100 200
500 1,000
5,000
Energized time (ms)
● Operating Environment
Precautions
The rated value for the ambient
operating temperature of the SSR is
determined under conditions when there
is no heat build-up. (Left graph)
Note that it is necessary to reduce the
load current as the ambient temperature
of the SSR may increase due to
operating conditions.
(Figure below is an example of the
G3M-205P(L) model)
When using the SSR, design the system
to allow heat dissipation sufficient to stay
below the Load Current vs. Ambient
Temperature characteristic curve.
<X direction>
<Y direction>
<Z direction>
Load current (A)
Load current (A)
Load current (A)
Load Current vs. Ambient
Temperature (Close Mounting)
G3M-205 Series (5-A Load)
6
5
6
5
6
5
4
4
4
3
3
3
2.5A L=20.37ੈ
2
2.0A L=20.37ੈ
G
3
M
2.5A L=20.37ੈ
2
1.8A L=12.7ੈ
2
1.8A L=12.7ੈ
1
0.8A L=7.62ੈ
1
0.8A L=7.62ੈ
1.5A L=12.7ੈ
1
0
−30
0.6A L=7.62ੈ
−20
0
20 25
40
60
80
100
Ambient temperature (°C)
0
−30
−20
0
20 25
40
60
80
100
Ambient temperature (°C)
0
−30
−20
0
20 25
40
60
80
100
Ambient temperature (°C)
L
L
L L
L L
Top
Top
Top
3 pcs.
10 pcs.
Bottom
Bottom
Bottom
10 pcs.
3 pcs.
10 pcs.
• Thirty Relays are soldered to the PCB at each given spacing.
• Continuous power.
3
G3M
Solid State Relays
■Dimensions
(Unit: mm)
PCB Dimensions (BOTTOM VIEW)
G3M-203P(L)
G3M-203P(L)
G3M-203P(L)-4
2.54
Four, 1.2 dia. holes
Terminal Arrangement
(BOTTOM VIEW)
2.54
Input voltage
9 max.
40 max.
-
Load power supply
+
Load
G3M-203P(L)-4
20 max.
2.54
-4
Four, 1.2 dia. holes
3+
2
1
LOAD
INPUT
4
4±2
7.62
(5.08)*
12.7
10.16
0.7
0.4
2.54
1.5
*Input terminal pitch for models ending in "-4" is 5.08 mm.
PCB Dimensions (BOTTOM VIEW)
G3M-205P(L)
G3M-205P(L)
G3M-205P(L)-4
2.54
Four, 1.2 dia. holes
Terminal Arrangement
(BOTTOM VIEW)
2.54
Input voltage
-
7.6±0.2
Load power supply
+
40 max.
Load
G3M-205P(L)-4
G
3
M
2.54
25 max.
2.54
4
4±2
7.62
(5.08)*
12.7
10.16
0.7
0.4
1.65
*Input terminal pitch for models ending in "-4" is 5.08 mm.
■Precautions
• Please refer to “Solid State Relays Common Precautions” for correct use.
4
-4
Four, 1.2 dia. holes
3+
INPUT
2
1
LOAD
G3M
Solid State Relays
G
3
M
• Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
• Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.
OMRON Corporation
Electronic and Mechanical Components Company
Contact: www.omron.com/ecb
Cat. No. K073-E1-07
1014(0207)(O)
5