G3M Solid State Relays 5A Load Switching provided for the whole G3M product line • Thin design for high-density PCB applications. • DC input-AC output for a 3-A load or a 5-A load. • The 5A type is UL, CSA, EN (EN60950) approved. • UL and CSA compliance for 3-A Relays (-UTU models have TÜV compliance as well). • UL and CSA compliance for 5-A Relays (-VD models have VDE compliance as well). RoHS Compliant Refer to "Solid State Relays Common Precautions". ■Model Number Legend G 3 M -@ @ @@ @ -@ -@ ———— — — 1 2 3 4 5 6 1. Rated Load Power Supply Voltage 2: Maximum operating voltage lower than 264 V 4. Zero Cross Function Blank: Equipped with zero cross function L : Not equipped with zero cross function 2. Rated Load Current 03: 3 A 05: 5 A 5. Certification Blank: UL and CSA for 3-A models No certification for 5-A models UTU : UL, CSA and TÜV for 3-A models VD : UL, CSA and TÜV for 5-A models UTU-1 : UL, CSA and TÜV for 3-A models with reinforced insulation VD-1 : UL, CSA and TÜV for 5-A models with reinforced insulation 3. Terminal Type P: PCB terminals 6. Input Terminal Pitch Blank: 7.62 mm 4 : 5.08 mm G 3 M ■List of Models Isolation Input terminal pitch Zero cross function Indicator Rated output load Rated input voltage 5 VDC G3M-203P 5 VDC 3 A at 100 to 240 VAC 12 VDC G3M-203P 12 VDC 24 VDC G3M-203P 24 VDC 5 VDC G3M-205P 5 VDC 12 VDC G3M-205P 12 VDC 24 VDC G3M-205P 24 VDC 5 VDC G3M-203PL 5 VDC 12 VDC G3M-203PL 12 VDC 24 VDC G3M-203PL 24 VDC 5 VDC G3M-205PL 5 VDC 12 VDC G3M-205PL 12 VDC 24 VDC G3M-205PL 24 VDC 5 VDC G3M-203P-4 5 VDC 12 VDC G3M-203P-4 12 VDC 24 VDC G3M-203P-4 24 VDC 5 VDC G3M-205P-4 5 VDC 12 VDC G3M-205P-4 12 VDC 24 VDC G3M-205P-4 24 VDC 5 VDC G3M-203PL-4 5 VDC 12 VDC G3M-203PL-4 12 VDC 24 VDC G3M-203PL-4 24 VDC 5 VDC G3M-205PL-4 5 VDC 12 VDC G3M-205PL-4 12 VDC 24 VDC G3M-205PL-4 24 VDC Yes 5 A at 100 to 240 VAC 7.62 mm 3 A at 100 to 240 VAC No 5 A at 100 to 240 VAC Phototriac No 3 A at 100 to 240 VAC Yes 5 A at 100 to 240 VAC 5.08 mm 3 A at 100 to 240 VAC No 5 A at 100 to 240 VAC Minimum packing unit Model 100 pcs 1 G3M Solid State Relays ■Ratings Input (Each model has 5-VDC, 12-VDC, and 24-VDC input versions.) Rated voltage Operating voltage 5 VDC 4 to 6 VDC Impedance Must operate voltage level 300 Ω ±20% 4 VDC max. 12 VDC 9.6 to 14.4 VDC 800 Ω ±20% 9.6 VDC max. 24 VDC 19.2 to 28.8 VDC 1.6 kΩ ±20% 19.2 VDC max. Output Must release voltage level Item Model G3M-203P(L) 1 VDC min. G3M-205P(L) * Rated voltage 100 to 240 VAC Model Operate time Release time G3M-203P(L) 1/2 of load power source cycle + 1 ms max. 1.6 V (RMS) max. Leakage current Insulation resistance Dielectric strength Vibration resistance 1.5 mA max. (at 200 VAC) 1,000 MΩ min. (at 500 VDC) 2,500 VAC, 50/60 Hz for 1 min between input and output 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) 1,000 m/s2 Shock resistance Ambient operating temperature −30°C to 80°C (with no icing or condensation) Ambient operating humidity Storage temperature G 3 M Weight 2 G3M-205P(L) G3M-@@@PL: 1 ms max. G3M-@@@P: 1/2 of load power source cycle + 1 ms max. Output ON voltage drop 45% to 85%RH −30°C to 100°C (with no icing or condensation) Approx. 15 g Load voltage range Load current Inrush current 0.1 to 3 A * 45 A (60 Hz, 1 cycle) 0.1 to 5 A * 60 A (60Hz, 1 cycle) 75 to 264 VAC The load current varies depending on the ambient temperature. Refer to Load Current vs. Ambient Temperature under Engineering Data. ■Characteristics Item Applicable load Approx. 25 g G3M Solid State Relays Load current (A) Load Current vs. Ambient Temperature 6 G3M-205P(L) 5 4 G3M-203P(L) One Cycle Surge Current: Non-repetitive Non-repetitive (Reduce the current under the dotted line of the impulse withstand current for repetitive operation) Inrush peak current (A) ■Engineering Data 70 60 50 G3M-205P(L) 40 G3M-203P(L) 3 30 2 20 1 10 0.5 0 -30 -20 0 20 25 40 60 80 100 Ambient temperature (°C) 10 30 50 100 200 500 1,000 5,000 Energized time (ms) ● Operating Environment Precautions The rated value for the ambient operating temperature of the SSR is determined under conditions when there is no heat build-up. (Left graph) Note that it is necessary to reduce the load current as the ambient temperature of the SSR may increase due to operating conditions. (Figure below is an example of the G3M-205P(L) model) When using the SSR, design the system to allow heat dissipation sufficient to stay below the Load Current vs. Ambient Temperature characteristic curve. <X direction> <Y direction> <Z direction> Load current (A) Load current (A) Load current (A) Load Current vs. Ambient Temperature (Close Mounting) G3M-205 Series (5-A Load) 6 5 6 5 6 5 4 4 4 3 3 3 2.5A L=20.37ੈ 2 2.0A L=20.37ੈ G 3 M 2.5A L=20.37ੈ 2 1.8A L=12.7ੈ 2 1.8A L=12.7ੈ 1 0.8A L=7.62ੈ 1 0.8A L=7.62ੈ 1.5A L=12.7ੈ 1 0 −30 0.6A L=7.62ੈ −20 0 20 25 40 60 80 100 Ambient temperature (°C) 0 −30 −20 0 20 25 40 60 80 100 Ambient temperature (°C) 0 −30 −20 0 20 25 40 60 80 100 Ambient temperature (°C) L L L L L L Top Top Top 3 pcs. 10 pcs. Bottom Bottom Bottom 10 pcs. 3 pcs. 10 pcs. • Thirty Relays are soldered to the PCB at each given spacing. • Continuous power. 3 G3M Solid State Relays ■Dimensions (Unit: mm) PCB Dimensions (BOTTOM VIEW) G3M-203P(L) G3M-203P(L) G3M-203P(L)-4 2.54 Four, 1.2 dia. holes Terminal Arrangement (BOTTOM VIEW) 2.54 Input voltage 9 max. 40 max. - Load power supply + Load G3M-203P(L)-4 20 max. 2.54 -4 Four, 1.2 dia. holes 3+ 2 1 LOAD INPUT 4 4±2 7.62 (5.08)* 12.7 10.16 0.7 0.4 2.54 1.5 *Input terminal pitch for models ending in "-4" is 5.08 mm. PCB Dimensions (BOTTOM VIEW) G3M-205P(L) G3M-205P(L) G3M-205P(L)-4 2.54 Four, 1.2 dia. holes Terminal Arrangement (BOTTOM VIEW) 2.54 Input voltage - 7.6±0.2 Load power supply + 40 max. Load G3M-205P(L)-4 G 3 M 2.54 25 max. 2.54 4 4±2 7.62 (5.08)* 12.7 10.16 0.7 0.4 1.65 *Input terminal pitch for models ending in "-4" is 5.08 mm. ■Precautions • Please refer to “Solid State Relays Common Precautions” for correct use. 4 -4 Four, 1.2 dia. holes 3+ INPUT 2 1 LOAD G3M Solid State Relays G 3 M • Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product. • Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms. Note: Do not use this document to operate the Unit. OMRON Corporation Electronic and Mechanical Components Company Contact: www.omron.com/ecb Cat. No. K073-E1-07 1014(0207)(O) 5